992 resultados para 3D Sequential Imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. METHODS: Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions <0.5 cm in minimal diameter and hemodynamic instability. IVIM imaging was performed at 3 T, using a standard spin-echo Stejskal-Tanner pulsed gradients diffusion-weighted sequence, using 16 b values from 0 to 900 s/mm(2). Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. RESULTS: IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 · 10(-6)) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 · 10(-4) vs. 7.5 ± 0.86 · 10(-4) mm(2)/s, p = 1.3 · 10(-20)). CONCLUSION: IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il y a environ 125 millions d'années, au Crétacé inférieur, la position des continents et le climat terrestre étaient bien différents de ce que l'on connait aujourd'hui. Le Sud-Est de la France, secteur de cette étude, était alors recouvert d'eau, sous un climat chaud et humide. Sur la bordure de cette étendue d'eau (appelée bassin Vocontien), qui correspond aujourd'hui aux régions de la Provence, du Vaucluse, du Gard, de l'Ardèche et du Vercors, des plateformes carbonatées, (telles que les Bahamas), se développaient. Le calcaire, formé à partir des sédiments accumulés sur ces plateformes, est appelé Urgonien. L'objectif de cette étude est de définir les facteurs qui ont influencé le développement de cette plateforme carbonatée dite « urgonienne » et dans quelle mesure. Plusieurs missions de terrain ont permis de récolter de nombreux échantillons de roche en 52 lieux répartis sur l'ensemble du Sud-Est de la France. Les observations réalisées sur le terrain ainsi que les données acquises en laboratoire (microfaune, microfacies et données géo-chimiques) ont permis, de subdiviser chacune des 52 séries urgoniennes en séquences stratigraphiques et cortèges sédimentaires. La comparaison des épaisseurs et des faciès de chaque cortège sédimentaire permet de concevoir la géométrie et l'évolution paléogéographique de la plateforme urgonienne. Les résultats de cette étude démontrent que son organisation est principalement dirigée par des failles qui ont jouées pendant le dépôt des sédiments. Sur la bordure nord du bassin Vocontien, trois failles subméridiennes contrôlent la géométrie et la répartition des environnements de dépôt. Sur sa bordure sud, ces failles synsédimentaires d'orientation N30° et N110° délimitent des blocs basculés. En tête de bloc, des séries d'épaisseurs réduites à faciès de lagon interne se sont déposées alors que les pieds de blocs sont caractérisés par des épaisseurs importantes et la présence de faciès plus externes. Ces concepts ont ensuite été testés en construisant un modèle numérique en trois dimensions de l'Urgonien du Sud-Est de la France. Sa cohérence avec les données acquises tout au long de cette étude d'une part, et sa cohérence géométrique d'autre part, valide les théories avancées. Des formations équivalentes à l'Urgonien sont réparties dans le monde entier et notamment au Moyen-Orient où elles constituent les réservoirs pétroliers les plus importants. Etre capable de caractériser les facteurs ayant influencé son architecture permet par la suite une meilleure exploitation de ses ressources énergétiques. -- Au Crétacé inférieur, l'intense activité magmatique due à la dislocation du super-continent Pangée influence fortement les conditions environnementales globales. Au Barrémien terminal et Aptien basal, période géologique dont fait l'objet cette étude, le bassin Vocontien, puis Bédoulien, recouvre le Sud-Est de la France, sous un climat chaud et humide. Sur les bordures de ces bassins, des plateformes carbonatées se mettent en place. Les sédiments qui se déposent sur ces plateformes sont à l'origine de la formation urgonienne. Afin d'étudier cette formation, une charte biostratigraphique, principalement basée sur les Orbitolinidés, et un modèle de faciès ont été développés. Les assemblages faunistiques, la succession des faciès, les observations de terrain ainsi que l'étude de signaux géochimiques ont permis le découpage séquentiel de la série urgonienne le long de 54 coupes et puis, répartis sur l'ensemble du Sud-Est de la France. Les corrélations induites par cette étude stratigraphique ont mis en évidence d'importantes variations d'épaisseur et d'environnements de dépôt au sein même de la plateforme urgonienne. Ces variations sont expliquées par le jeu de failles syn-sédimentaires qui ont compartimentées la plateforme urgonienne en blocs. Sur la bordure sud du bassin Vocontien, ces failles d'orientation N30° et N110° délimitent six blocs basculés. Au sommet du Barrémien terminal, la subsidence des blocs situés le plus au sud s'amplifie jusqu'à provoquer l'ouverture du bassin de la Bédoule au sud du secteur d'étude. Cette théorie d'évolution a ensuite été testée par l'élaboration d'un modèle numérique en trois dimensions de l'Urgonien du Sud-Est de la France. Sa cohérence avec les données acquises tout au long de cette étude d'une part, et sa cohérence géométrique d'autre part, valide les théories avancées. Des analogues de l'Urgonien sont répartis dans le monde entier et notamment au Moyen-Orient où ils représentent d'importants réservoirs pétroliers. Être capable de caractériser les facteurs ayant influencé l'architecture de l'Urgonien du Sud-Est de la France permet par la suite une meilleure exploitation de ses ressources énergétiques. -- During the Early Cretaceous epoch, intensive magmatic activity due to the dislocation of the super-continent Pangaea, highly influenced global environmental conditions, which were characterized by a warm and generally humic climate. In this context, carbonate platforms were important in tropical and subtropical shallow-water regions, and especially during the late Barremian and early Aptian, platform carbonates of so-called Urgonian affinity are widespread. In southeastern France, the Urgonian platform was part of the northern Tethyan margin and bordered the Vocontian and the Bedoulian basins. The goal of this thesis was the systematic study of the Urgonian Formation in this region, and in order to achieve this goal, a biostratigraphic chart and a facies model were developed. The faunistic assemblages, the facies succession, the field observations and the study of geochemical signals lead to a sequential subdivision of the Urgonian series along 54 sections and wells allocated in five different regions in southeastern France (Gard, Ardèche, Vercors, Vaucluse and Provence). Correlations from this stratigraphic study highlight important variations in thickness and depositional environments of the Urgonian series. These variations are explained by relative movements induced by syn-sedimentary faults, which divided the Urgonian platforms into blocks. On the southern border of the Vocontian basin, these faults, oriented N30° and N110°, delineate six tilted blocks. At the top of the upper Barremian carbonates, subsidence of the two southern blocks accelerated leading to the opening of the Bedoulian basin. The reconstruction of the sequence-stratigraphic and paleoenvironmental evolution of the Urgonian platforms was then tested by the construction of a 3D numerical model of the Urgonian formation of southeastern France. Firstly, its consistency with the data collected during this study, and secondly, its geometrical coherence validate the proposed theory. Urgonian analogs exist all over the world and particularly in Middle East where they constitute important oil reservoirs. The exact reconstruction of the major factors, which influenced the architecture of these formations, will allow for a better exploitation of these energy resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary MR imaging is a promising noninvasive technique for the combined assessment of coronary artery anatomy and function. Anomalous coronary arteries and aneurysms can reliably be assessed in clinical practice using coronary MR imaging and the presence of significant left main or proximal multivessel coronary artery disease detected. Technical challenges that need to be addressed are further improvements in motion suppression and abbreviated scanning times aimed at improving spatial resolution and patient comfort. The development of new and specific contrast agents, high-field MR imaging with improved spatial resolution, and continued progress in MR imaging methods development will undoubtedly lead to further progress toward the noninvasive and comprehensive assessment of coronary atherosclerotic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malonate, methylmalonate and propionate are potentially neurotoxic metabolites in branched-chain organic acidurias. Their effects were tested on cultured 3D rat brain cell aggregates, using dosages of 0.1, 1.0 and 10.0 mM with a short but intense (twice a day over 3 days) and a longer but less intense treatment (every 3 rdday over 9 days). CNS cell-specific immunohistochemical stainings allowed the follow-up of neurons (axons, phosphorylated medium-weight neurofilament), astrocytes (glial fibrillary acidic protein) and oligodendrocytes (myelin basic protein). Methylmalonate and malonate were quantified by tandem mass spectrometry. Tandem mass spectrometry analysis of harvested brain cell aggregates revealed clear intracellular accumulation of methylmalonate and malonate. In immunohistochemical stainings oligodendrocytes appeared the most affected brain cells. The MBP signal disappeared already at 0.1 mM treatment with each metabolite. Mature astrocytes were not affected by propionate, while immature astrocytes on intense treatment with propionate developed cell swelling. 1 mM methylmalonate induced cell swelling of both immature and mature astrocytes , while 1 mM malonate only affected mature astrocytes. Neurons were not affected by methylmalonate, but 10.0 mM malonate on less intense treatment and 0.1, 1.0 and 10.0 mM propionate on intense treatment affected axonal growth. Our study shows significant uptake and deleterious effects of these metabolites on brain cells, principally on astrocytes and oligodendrocytes. This may be explained by the absence of the pathway in glial cells, which thus are not able to degrade these metabolites. Further studies are ongoing to elucidate the underlying mechanisms of the observed neurotoxic effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CMR has recently emerged as a robust and reliable technique to assess coronary artery disease (CAD). A negative perfusion CMR test predicts low event rates of 0.3-0.5%/year. Invasive coronary angiography (CA) remains the "gold standard" for the evaluation of CAD in many countries.Objective: Assessing the costs of the two strategies in the European CMR registry for the work-up of known or suspected CAD from a health care payer perspective. Strategy 1) a CA to all patients or 2) a CA only to patients who are diagnosed positive for ischemia in a prior CMR.Method and results: Using data of the European CMR registry (20 hospitals, 11'040 consecutive patients) we calculated the proportion of patients who were diagnosed positive (20.6%), uncertain (6.5%), and negative (72.9%) after the CMR test in patients with known or suspected CAD (n=2'717). No other medical test was performed to patients who were negative for ischemia. Positive diagnosed patients had a coronary angiography. Those with uncertain diagnosis had additional tests (84.7%: stress echocardiography, 13.1%: CCT, 2.3% SPECT), these costs were added to the CMR strategy costs. Information from costs for tests in Germany and Switzerland were used. A sensibility analysis was performed for inpatient CA. For costs see figure. Results - costs.Discussion: The CMR strategy costs less than the CA strategy for the health insurance systems both, in Germany and Switzerland. While lower in costs, the CMR strategy is a non-invasive one, does not expose to radiation, and yields additional information on cardiac function, viability, valves, and great vessels. Developing the use of CMR instead of CA might imply some reduction in costs together with superior patient safety and comfort, and a better utilization of resources at the hospital level. Document introduit le : 01.12.2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la carrera del mundo de los videojuegos por alcanzar insospechables cotas de realismo con las que seguir sorprendiendo y enganchando al público, los motores de física se han convertido en la herramienta de presente y futuro. Atraídos por el auge de esta nueva tecnología, hemos lidiado con los motores referencia hoy día en el mercado, seleccionando luego uno de ellos e implementando un humilde videojuego de carreras como muestra de su potencial y de los conocimientos adquiridos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.