823 resultados para 369999 Other Policy and Political Science
Resumo:
Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.
Resumo:
One of the current trends in governance and legal development in Russia is aimed at establishing a modern, efficient and internationally harmonised system of safeguards of human rights and civil liberties. A fairly recent addition to this system has been the institution of ombudsman as a public authority specialised in promoting and protecting human rights and civil liberties. The introduction of this institution as well as its formalisation at the constitutional and legislative levels has been increasingly relevant and important, as it raises the dealings between the state and the individual to a new level. As an independent public institution resolving conflicts between citizens and government authorities, the ombudsman makes steps, within the scope of his jurisdiction, to restitute individual rights, and helps to enhance the reputation of government. The present work describes and assesses the birth, development and institutionalization process of the Ombudsman Office in the Russian Federation, at federal and regional levels, with a particular emphasis on the role of international references and cooperation for institution building. Ombudsmen have done a magnificent job in demonstrating value with the resolution of individual and systemic complaints; subsequent improvements to government; and economic savings by mitigating litigation costs.
Resumo:
Die vorliegende Dissertation besteht aus sechs Kapiteln und trägt zur Forschung in den Bereichen der Finanzmarktpolitik und der Geldpolitik bei. Das zweite Kapitel zeigt die Wechselbeziehung zwischen Geldmarktanspannungen und der Stabilität des Finanzsystems auf. Mittels der theoretischen Literatur werden verschiedene Einflussfaktoren einer aggregierten Liquiditätsnachfragefunktion präsentiert. Das dritte Kapitel untersucht den Informationsgehalt der Ergebnisse der Hauptrefinanzierungsgeschäfte für den europäischen Geldmarkt. Unsere Ergebnisse zeigen, dass sich seit der Finanzkrise der Informationsgehalt der Hauptrefinanzierungsgeschäfte in zweierlei Hinsicht verändert hat. Im vierten Kapitel untersuchen wir die Wirksamkeit der Geldpolitik während der Finanzkrise europäische Geldmarktzinssätze zu steuern. Die Ergebnisse deuten auf eine erhebliche Divergenz zwischen den Zinssätzen und den Erwartungen über die zukünftige Geldpolitik hin. Weiterhin finden wir heraus, dass die unkonventionellen Maßnahmen der EZB für einen Rückgang der Euriborsätze von bis zu 60 Basispunkten verantwortlich sind. Das fünfte Kapitel beschäftigt sich mit der Funktionsweise des besonderen geldpolitischen Instrumentariums der Schweizerischen Nationalbank.
Resumo:
Phosphatidylethanol (PEth) is a direct ethanol metabolite, and has recently attracted attention as biomarker of ethanol intake. The aims of the current study are: (1) to characterize the normalization time of PEth in larger samples than previously conducted; (2) to elucidate potential gender differences; and (3) to report the correlation of PEth with other biomarkers and self-reported alcohol consumption. Fifty-seven alcohol-dependent patients (ICD 10 F 10.25; 9 females, 48 males) entering medical detoxification at three study sites were enrolled. The study sample was comprised of 48 males and 9 females, with mean age 43.5. Mean gamma glutamyl transpeptidase (GGT) was 209.61 U/l, average mean corpuscular volume (MCV) was 97.35 fl, mean carbohydrate deficient transferrin (%CDT) was 8.68, and mean total ethanol intake in the last 7 days was 1653 g. PEth was measured in heparinized whole blood with a high-pressure liquid chromatography method, while GGT, MCV and %CDT were measured using routine methods. PEth levels at day 1 of detoxification ranged between 0.63 and 26.95 micromol/l (6.22 mean, 4.70 median, SD 4.97). There were no false negatives at day 1. Sensitivities for the other biomarkers were 40.4% for MCV, 73.1% for GGT and 69.2% for %CDT, respectively. No gender differences were found for PEth levels at any time point. Our data suggest that PEth is (1) a suitable intermediate term marker of ethanol intake in both sexes; and (2) sensitivity is extraordinary high in alcohol dependent patients. The results add further evidence to the data that suggest that PEth has potential as a candidate for a sensitive and specific biomarker, which reflects longer-lasting intake of higher amounts of alcohol and seemingly has the above mentioned certain advantages over traditional biomarkers.