953 resultados para wind turbine generator


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a comparison between proportional integral control approaches for variable speed wind turbines. Integer and fractional-order controllers are designed using linearized wind turbine model whilst fuzzy controller also takes into account system nonlinearities. These controllers operate in the full load region and the main objective is to extract maximum power from the wind turbine while ensuring the performance and reliability required to be integrated into an electric grid. The main contribution focuses on the use of fractional-order proportional integral (FOPI) controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. A comparison between proposed control approaches for the variable speed wind turbines is presented using a wind turbine benchmark model in the Matlab/Simulink environment. Results show that FOPI has improved system performance when compared with classical PI and fuzzy PI controller outperforms the integer and fractional-order control due to its capability to deal with system nonlinearities and uncertainties. © 2014 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Für große Windenergieanlagen werden neue Pitchregler wie Einzelblattregler oder Turmdämpfungsregler entwickelt. Während diese neuen Pitchregler die Elemente der Windenergieanlagen entlasten, wird das Pitchantriebssystem stärker belastet. Die Pitchantriebe müssen weitaus häufiger bei höherer Amplitude arbeiten. Um die neuen Pitchregler nutzen zu können, muss zunächst das Problem der Materialermüdung der Pitchantriebssysteme gelöst werden. Das Getriebespiel in Getrieben und zwischen Ritzeln und dem Zahnkranz erhöht die Materialermüdung in den Pitchantriebssystemen. In dieser Studie werden als Lösung zwei Pitchantriebe pro Blatt vorgeschlagen. Die beiden Pitchantriebe erzeugen eine Spannung auf dem Pitchantriebssystem und kompensieren das Getriebespiel. Drehmomentspitzen, die eine Materialermüdung verursachen, treten bei diesem System mit zwei Pitchmotoren nicht mehr auf. Ein Reglerausgang wird via Drehmomentverteiler auf die beiden Pitchantriebe übertragen. Es werden mehrere Methoden verglichen und der leistungsfähigste Drehmomentverteiler ausgewählt. Während die Pitchantriebe in Bewegung sind, ändert sich die Spannung auf den Getrieben. Die neuen Pitchregler verstellen den Pitchwinkel in einer sinusförmigen Welle. Der Profilgenerator, der derzeit als Pitchwinkelregler verwendet wird, kann eine Phasenverzögerung im sinusförmigen Pitchwinkel verursachen. Zusätzlich erzeugen große Windenergieanlagen eine hohe Last, die sich störend auf die Pitchbewegung auswirkt. Änderungen der viskosen Reibung und Nichtlinearität der Gleitreibung bzw. Coulombsche Reibung des Pitchregelsystems erschweren zudem die Entwicklung eines Pitchwinkelreglers. Es werden zwei robuste Regler (H∞ und μ–synthesis ) vorgestellt und mit zwei herkömmlichen Reglern (PD und Kaskadenregler) verglichen. Zur Erprobung des Pitchantriebssystems und des Pitchwinkelreglers wird eine Prüfanordnung verwendet. Da der Kranz nicht mit einem Positionssensor ausgestattet ist, wird ein Überwachungselement entwickelt, das die Kranzposition meldet. Neben den beiden Pitchantrieben sind zwei Lastmotoren mit dem Kranz verbunden. Über die beiden Lastmotoren wird das Drehmoment um die Pitchachse einer Windenergieanlage simuliert. Das Drehmoment um die Pitchachse setzt sich zusammen aus Schwerkraft, aerodynamischer Kraft, zentrifugaler Belastung, Reibung aufgrund des Kippmoments und der Beschleunigung bzw. Verzögerung des Rotorblatts. Das Blatt wird als Zweimassenschwinger modelliert. Große Windenergieanlagen und neue Pitchregler für die Anlagen erfordern ein neues Pitchantriebssystem. Als Hardware-Lösung bieten sich zwei Pitchantriebe an mit einem robusten Regler als Software.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present invention provides an improvement for a wind turbine (20) having at least one blade (21) mounted on a hub (22) for controlled rotation about a blade axis (yb-yb) to vary the pitch of the blade relative to an airstream. The hub is mounted on a nacelle (23) for rotation about a hub axis (xh-xh). The wind turbine includes a main pitch control system for selectively controlling the pitch of the blade, and/or a safety pitch control system for overriding the main blade pitch control system and for causing the blade to move toward a feathered position in the event of an overspeed or fault condition. The improvement includes: an energy storage device (26) mounted on the nacelle and associated with the blade; a pitch-axis controller (25) mounted on the nacelle and associated with the blade and with the energy storage device; an electro-mechanical actuator (28) mounted on the hub and associated with the blade; and at least one slip ring (29) operatively arranged to transmit power and/or data signals between the pitch-axis controller and the electro-mechanical actuator; whereby the mass on the rotating hub may be reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The last few years have proved that Vertical Axis Wind Turbines (VAWTs) are more suitable for urban areas than Horizontal Axis Wind Turbines (HAWTs). To date, very little has been published in this area to assess good performance and lifetime of VAWTs either in open or urban areas. At low tip speed ratios (TSRs<5), VAWTs are subjected to a phenomenon called 'dynamic stall'. This can really affect the fatigue life of a VAWT if it is not well understood. The purpose of this paper is to investigate how CFD is able to simulate the dynamic stall for 2-D flow around VAWT blades. During the numerical simulations different turbulence models were used and compared with the data available on the subject. In this numerical analysis the Shear Stress Transport (SST) turbulence model seems to predict the dynamic stall better than the other turbulence models available. The limitations of the study are that the simulations are based on a 2-D case with constant wind and rotational speeds instead of considering a 3-D case with variable wind speeds. This approach was necessary for having a numerical analysis at low computational cost and time. Consequently, in the future it is strongly suggested to develop a more sophisticated model that is a more realistic simulation of a dynamic stall in a three-dimensional VAWT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the integration of vertical axis wind turbines in the built environment is a promising alternative to horizontal axis wind turbines, a 2D computational investigation of an augmented wind turbine is proposed and analysed. In the initial CFD analysis, three parameters are carefully investigated: mesh resolution; turbulence model; and time step size. It appears that the mesh resolution and the turbulence model affect result accuracy; while the time step size examined, for the unsteady nature of the flow, has small impact on the numerical results. In the CFD validation of the open rotor with secondary data, the numerical results are in good agreement in terms of shape. It is, however, observed a discrepancy factor of 2 between numerical and experimental data. Successively, the introduction of an omnidirectional stator around the wind turbine increases the power and torque coefficients by around 30–35% when compared to the open case; but attention needs to be given to the orientation of the stator blades for optimum performance. It is found that the power and torque coefficients of the augmented wind turbine are independent of the incident wind speed considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

http://digitalcommons.colby.edu/atlasofmaine2009/1029/thumbnail.jpg

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project was designed to demonstrate the visibility of potential future wind turbines built on the Colby campus. We conducted viewshed analyses in ArcGIS on three different potential turbine sites to determine the visibility of the turbines within a 10km radius. We found that the Runnals hill turbine would be visible to the largest area and the largest number of residents.