980 resultados para very low food secure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The investigation of vortex-induced vibration on very short cylinders with two degrees of freedom has drawn the attention of a large number of researchers. Some investigations on such a problem are carried out in order to have a better understanding of the physics involved in vortex-induced motions of floating bodies such as offshore platforms. In this paper, experiments were carried out in a recirculating water channel over the range of Reynolds number 6000very low aspect ratios (0.3≤L/D≤2.0) were shown and the results were discussed in depth. Conversely to what would be expected for cylinders with very low aspect ratio, the results showed large motions in the transverse direction with maximum amplitudes around 1.5 diameters for cylinders with L/D=2.0, despite being smaller when the aspect ratio is reduced. Moreover, the response amplitudes presented high values around 0.4 diameters in the in-line direction. In fact, the large transverse motions were related to a strong coupling with the in-line responses, visibly identified in the plots of nondimensional frequency, as well as by the trajectories in the XY-plane, Lissajous figures, particularly in the case of m⁎=1.00 and L/D=2.0, when 8-shape trajectories were clearly observed. The case of m⁎=1.00 deserves more attention because of its smaller amplitude compared to the cases with the same aspect ratio and a larger mass ratio. This counter-intuitive behavior seems to be related to the energy transferring process from the steady stream to the oscillatory hydroelastic system. Finally, it is noteworthy that the characteristic of the “Strouhal-like” number decreases when the aspect ratio decreases, as also observed in previous works available in the literature, most of them for stationary cylinders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The investigation of vortex-induced vibration on very short cylinders with two degrees of freedom has drawn the attention of a large number of researchers. Some investigations on such a problem are carried out in order to have a better understanding of the physics involved in vortex-induced motions of floating bodies such as offshore platforms. In this paper, experiments were carried out in a recirculating water channel over the range of Reynolds number 6000very low aspect ratios (0.3≤L/D≤2.0) were shown and the results were discussed in depth. Conversely to what would be expected for cylinders with very low aspect ratio, the results showed large motions in the transverse direction with maximum amplitudes around 1.5 diameters for cylinders with L/D=2.0, despite being smaller when the aspect ratio is reduced. Moreover, the response amplitudes presented high values around 0.4 diameters in the in-line direction. In fact, the large transverse motions were related to a strong coupling with the in-line responses, visibly identified in the plots of nondimensional frequency, as well as by the trajectories in the XY-plane, Lissajous figures, particularly in the case of m⁎=1.00 and L/D=2.0, when 8-shape trajectories were clearly observed. The case of m⁎=1.00 deserves more attention because of its smaller amplitude compared to the cases with the same aspect ratio and a larger mass ratio. This counter-intuitive behavior seems to be related to the energy transferring process from the steady stream to the oscillatory hydroelastic system. Finally, it is noteworthy that the characteristic of the “Strouhal-like” number decreases when the aspect ratio decreases, as also observed in previous works available in the literature, most of them for stationary cylinders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurodevelopment of preterm children has become an outcome of major interest since the improvement in survival due to advances in neonatal care. Many studies focused on the relationships among prenatal characteristics and neurodevelopmental outcome in order to identify the higher risk preterms’ subgroups. The aim of this study is to analyze and put in relation growth and development trajectories to investigate their association. 346 children born at the S.Orsola Hospital in Bologna from 01/01/2005 to 30/06/2011 with a birth weight of <1500 grams were followed up in a longitudinal study at different intervals from 3 to 24 months of corrected age. During follow-up visits, preterms’ main biometrical characteristics were measured and the Griffiths Mental Development Scale was administered to assess neurodevelopment. Latent Curve Models were developed to estimate the trajectories of length and of neurodevelopment, both separately and combined in a single model, and to assess the influence of clinical and socio-economic variables. Neurodevelopment trajectory was stepwise declining over time and length trajectory showed a steep increase until 12 months and was flat afterwards. Higher initial values of length were correlated with higher initial values of neurodevelopment and predicted a more declining neurodevelopment. SGA preterms and those from families with higher status had a less declining neurodevelopment slope, while being born from a migrant mother proved negative on neurodevelopment through the mediating effect of a being taller at 3 months. A longer stay in NICU used as a proxy of preterms’ morbidity) was predictive of lower initial neurodevelopment levels. At 24 months, neurodevelopment is more similar among preterms and is more accurately evaluated. The association among preterms’ neurodevelopment and physiological growth may provide further insights on the determinants of preterms’ outcomes. Sound statistical methods, exploiting all the information collected in a longitudinal study, may be more appropriate to the analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surveys from the USA, Australia and Spain have shown significant inter-institutional variation in delivery room (DR) management of very low birth weight infants (VLBWI, <1500g) at birth, despite regularly updated international guidelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low somatic cell count (SCC) is a reliable indicator of high-quality milk free of pathogenic microorganisms. Thus, an important goal in dairy practice is to produce milk with low SCC. Selection for cows with low SCC can sometimes lead to extremely low SCC in single quarters. The cells in milk are, however, predominantly immune cells with important immune functions. To investigate the mammary immune competence of quarters with very low SCC, healthy udder quarters of cows with normal SCC of (40-100) x 10(3) cells/ml and very low SCC of < 20 x 10(3) cells/ml were challenged with lipopolysaccharide (LPS) from Escherichia coli. In the first experiment, SCC and cell viability after a challenge with 50 ng of LPS/quarter was investigated. In the second experiment, tumour necrosis factor alpha (TNF-alpha) concentration and lactate dehydrogenase (LDH) activity in milk, and mRNA expression of various innate immune factors in milk cells were measured after a challenge with 100 mug LPS/quarter. LPS challenge induced an increase of SCC. SCC levels reached were higher in quarters with normal SCC and maximum SCC was reached 1 h earlier than in very low SCC quarters. The increase of TNF-alpha concentrations in milk in response to LPS challenge was lower in quarters with very low SCC than in quarters with normal SCC. The viability of cells and the LDH activity in milk increased in response to LPS challenge, however, without a difference between the groups. The mRNA expression of IL-1beta and IL-8 was increased in milk cells at 12 h after LPS challenge, whereas that of TNF-alpha and lactoferrin was not increased at the measured time points (12, 24 and 36 h after LPS challenge). No differences of mRNA expression of measured immune factors between normal and very low SCC samples were detected. The study showed that udder quarters with very low SCC responded with a less marked increase of SCC compared with quarters with normal SCC. This difference corresponded with simultaneously lower TNF-alpha concentrations in milk. However, the immune competence of the cells themselves based on mRNA expression of TNF-alpha, IL-8, IL-1beta, and lactoferrin, did not differ. The results may indicate that very low SCC can impair the immune competence of udder quarters, because the immune response in udder quarters with lower SCC is less efficient as fewer cells contribute to the production of immunoregulators.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with adult GH deficiency are often dyslipidemic and may have an increased risk of cardiovascular disease. The secretion and clearance of very low density lipoprotein apolipoprotein B 100 (VLDL apoB) are important determinants of plasma lipid concentrations. This study examined the effect of GH replacement therapy on VLDL apoB metabolism using a stable isotope turnover technique. VLDL apoB kinetics were determined in 14 adult patients with GH deficiency before and after 3 months GH or placebo treatment in a randomized double blind, placebo-controlled study using a primed constant [1-(13)C]leucine infusion. VLDL apoB enrichment was determined by gas chromatography-mass spectrometry. GH replacement therapy increased plasma insulin-like growth factor I concentrations 2.9 +/- 0.5-fold (P < 0.001), fasting insulin concentrations 1.8 +/- 0.6-fold (P < 0.04), and hemoglobin A1C from 5.0 +/- 0.2% to 5.3 +/- 0.2% (mean +/- SEM; P < 0.001). It decreased fat mass by 3.4 +/- 1.3 kg (P < 0.05) and increased lean body mass by 3.5 +/- 0.8 kg (P < 0.01). The total cholesterol concentration (P < 0.02), the low density lipoprotein cholesterol concentration (P < 0.02), and the VLDL cholesterol/VLDL apoB ratio (P < 0.005) decreased. GH therapy did not significantly change the VLDL apoB pool size, but increased the VLDL apoB secretion rate from 9.2 +/- 2.0 to 25.9 +/- 10.3 mg/kg x day (P < 0.01) and the MCR from 11.5 +/- 2.7 to 20.3 +/- 3.2 mL/min (P < 0.03). No significant changes were observed in the placebo group. This study suggests that GH replacement therapy improves lipid profile by increasing the removal of VLDL apoB. Although GH therapy stimulates VLDL apoB secretion, this is offset by the increase in the VLDL apoB clearance rate, which we postulate is due to its effects in up-regulating low density lipoprotein receptors and modifying VLDL composition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increased cardiovascular mortality in adult growth hormone deficiency (GHD) may be, in part, explained by the dyslipidaemia associated with this condition. It is possible that abnormalities of very low density lipoprotein apolipoprotein B-100 (VLDL apoB) metabolism contribute to this dyslipidaemia. To test this hypothesis, we measured VLDL apoB kinetics in adult GH deficient patients (4 females, 3 males; age 50.1 +/- 4.7 yr (mean +/- SEM); BMI 28.2 +/- 1.1 kg/m2; total cholesterol (TC) 6.6 +/- 0.3 mmol/l; triglyceride (TG) 2.8 +/- 0.6 mmol/l; HDL cholesterol 1.1 +/- 0.1 mmol/l) and in control subjects (4 females, 3 male; age 47.0 +/- 4.7 yr; BMI 27.0 +/- 2.6 kg/m2; TC 5.0 +/- 0.4 mmol/l; TG 0.9 +/- 0.2 mmol/l; HDL cholesterol 1.4 +/- 0.1 mmol/l). [1-(13)C] leucine was administered by a primed (1 mg/kg), constant intravenous infusion (1 mg/kg/hr) and VLDL apoB enrichment with 13C leucine was determined using gas-chromatography mass-spectrometry. The GHD patients had a significantly higher hepatic secretion rate of VLDL apoB (15.5 +/- 1.8 mg/kg/day vs 9.4 +/- 0.6 mg/kg/day p = 0.007) and reduced catabolism ofVLDL apoB (metabolic clearance rate; 12.3 +/- 1.7 ml/min vs 24.3 +/- 4.8 ml/min p < 0.05) compared with control subjects. These findings suggest that GH is integrally involved in the regulation of VLDL apoB metabolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: There is a continuous debate regarding the best bottle nipple to be used to enhance the bottle-feeding performance of a preterm infant. Aim: To verify that feeding performance can be improved by using the bottle nipple with the physical characteristics that enhance infants' sucking skills. METHODS: Ten "healthy" VLBW infants (941+/-273 g) were recruited. Feeding performance was monitored at two time periods, when taking 1-2 and 6-8 oral feedings/d. At each time and within 24 h, performance was monitored using three different bottle nipples offered in a randomized order. Rate of milk transfer (ml/min) was the primary outcome measure. The sucking skills monitored comprised stage of sucking, suction amplitude, and duration of the generated negative intraoral suction pressure. RESULTS: At both times, infants demonstrated a similar rate of milk transfer among all three nipples. However, the stage of sucking, suction amplitude, and duration of the generated suction were significantly different between nipples at 1-2, but not 6-8 oral feedings/d.CONCLUSION: We did not identify a particular bottle nipple that enhanced bottle feeding in healthy VLBW infants. Based on the notion that afferent sensory feedback may allow infants to adapt to changing conditions, we speculate that infants can modify their sucking skills in order to maintain a rate of milk transfer that is appropriate with the level of suck-swallow-breathe coordination achieved at a particular time. Therefore, it is proposed that caretakers should be more concerned over monitoring the coordination of suck-swallow-breathe than over the selection of bottle nipples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: (1) To compare maternal characteristics and psychological stress profile among African-American, Caucasian and Hispanic mothers who delivered very low birthweight infants. (2) To investigate associations between psychosocial factors, frequency of milk expression, skin-to-skin holding (STS), and lactation performance, defined as maternal drive to express milk and milk volume. STUDY DESIGN: Self-reported psychological questionnaires were given every 2 weeks after delivery over 10 weeks. Milk expression frequency, STS, and socioeconomic variables were collected. RESULT: Infant birthweight, education, and milk expression frequency differed between groups. Trait anxiety, depression and parental stress in a neonatal intensive care unit (PSS:NICU) were similar. African-American and Caucasian mothers reported the lowest scores in state anxiety and social desirability, respectively. Maternal drive to express milk, measured by maintenance of milk expression, correlated negatively with parental role alteration (subset of PSS:NICU) and positively with infant birthweight and STS. Milk volume correlated negatively with depression and positively with milk expression frequency and STS. CONCLUSION: Differences between groups were observed for certain psychosocial factors. The response bias to self-reported questionnaires between groups may not provide an accurate profile of maternal psychosocial profile. With different factors correlating with maintenance of milk expression and milk volume, lactation performance can be best enhanced with a multi-faceted intervention program, incorporating parental involvement in infant care, close awareness and management of maternal mental health, and encouragement for frequent milk expression and STS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The main objective was to assess the credibility of the evidence using Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) in oral health systematic reviews on the Cochrane Database of Systematic Reviews (CDSR) and elsewhere. STUDY DESIGN AND SETTING Systematic Reviews or meta-analyses (January 2008-December 2013) from 14 high impact general dental and specialty dental journals and the Cochrane Database of Systematic Reviews were screened for meta-analyses. Data was collected at the systematic review, meta-analysis and trial level. Two reviewers applied and agreed on the GRADE rating for the selected meta-analyses. RESULTS From the 510 systematic reviews initially identified 91 reviews (41 Cochrane and 50 non-Cochrane) were eligible for inclusion. The quality of evidence was high in 2% and moderate in 18% of the included meta-analyses with no difference between Cochrane and non-Cochrane reviews, journal impact factor or year of publication. The most common domains prompting downgrading of the evidence were study limitations (risk of bias) and imprecision (risk of play of chance). CONCLUSION The quality of the evidence in oral health assessed using GRADE is predominantly low or very low suggesting a pressing need for more randomised clinical trials and other studies of higher quality in order to inform clinical decisions thereby reducing the risk of instituting potentially ineffective and/or harmful therapies.