995 resultados para vertical electrical sounding


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study presented here was carried out to obtain the actual solids flow rate by the combination of electrical resistance tomography and electromagnetic flow meter. A new in-situ measurement method based on measurements of the Electromagnetic Flow Meters (EFM) and Electrical Resistance Tomography (ERT) to study the flow rates of individual phases in a vertical flow was proposed. The study was based on laboratory experiments that were carried out with a 50 mm vertical flow rig for a number of sand concentrations and different mixture velocities. A range of sand slurries with median particle size from 212 mu m to 355 mu m was tested. The solid concentration by volume covered was 5% and 15%, and the corresponding density of 5% was 1078 kg/m(3) and of 15% was 1238 kg/m(3). The flow velocity was between 1.5 m/s and 3.0 m/s. A total of 6 experimental tests were conducted. The equivalent liquid model was adopted to validate in-situ volumetric solids fraction and calculate the slip velocity. The results show that the ERT technique can be used in conjunction with an electromagnetic flow meter as a way of measurement of slurry flow rate in a vertical pipe flow. However it should be emphasized that the EFM results must be treated with reservation when the flow pattern at the EFM mounting position is a non-homogenous flow. The flow rate obtained by the EFM should be corrected considering the slip velocity and the flow pattern.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The deployment of OECBs (opto-electrical circuit boards) is expected to make a significant impact in the telecomm switches arena within the next five years. This will create optical backplanes with high speed point-to-point optical interconnects. The crucial aspect in the manufacturing process of the optical backplane is the successful coupling between VCSEL (vertical cavity surface emitting laser) device and embedded waveguide in the OECB. The results from a thermo-mechanical analysis are being used in a purely optical model, which solves optical energy and attenuation from the VCSEL aperture into, and then through, the waveguide. Results from the modelling are being investigated using DOE analysis to identify packaging parameters that minimise misalignment. This is achieved via a specialist optimisation software package. Results from the thermomechanical and optical models are discussed as are experimental results from the DOE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two mechanisms of conduction were identified from temperature dependent (120 K-340 K) DC electrical resistivity measurements of composites of poly(c-caprolactone) (PCL) and multi-walled carbon nanotubes (MWCNTs). Activation of variable range hopping (VRH) occurred at lower temperatures than that for temperature fluctuation induced tunneling (TFIT). Experimental data was in good agreement with the VRH model in contrast to the TFIT model, where broadening of tunnel junctions and increasing electrical resistivity at T > T-g is a consequence of a large difference in the coefficients of thermal expansion of PCL and MWCNTs. A numerical model was developed to explain this behavior accounting for a thermal expansion effect by supposing the large increase in electrical resistivity corresponds to the larger relative deformation due to thermal expansion associated with disintegration of the conductive MWCNT network. MWCNTs had a significant nucleating effect on PCL resulting in increased PCL crystallinity and an electrically insulating layer between MWCNTs. The onset of rheological percolation at similar to 0.18 vol% MWCNTs was clearly evident as storage modulus, G' and complex viscosity, vertical bar eta*vertical bar increased by several orders of magnitude. From Cole-Cole and Van Gurp-Palmen plots, and extraction of crossover points (G(c)) from overlaying plots of G' and G '' as a function of frequency, the onset of rheological percolation at 0.18 vol% MWCNTs was confirmed, a similar MWCNT loading to that determined for electrical percolation. 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The global atmospheric electrical circuit sustains a vertical current density between the ionosphere and the Earth's surface, the existence of which is well-established from measurements made in fair-weather conditions. In overcast, but non-thunderstorm, non-precipitating conditions, the current travels through the cloud present, despite cloud layers having low electrical conductivity. For extensive layer clouds, this leads to space charge at the upper and lower cloud boundaries. Using a combination of atmospheric electricity and solar radiation measurements at three UK sites, vertical current measurements have been categorised into clear, broken, and overcast cloud conditions. This approach shows that the vertical “fair weather” current is maintained despite the presence of cloud. In fully overcast conditions with thick cloud, the vertical current is reduced compared to thin cloud overcast conditions, associated with the cloud's resistance contributions. Contribution of cloud to the columnar resistance depends both on cloud thickness, and the cloud's height.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A vertical conduction current flows in the atmosphere as a result of the global atmospheric electric circuit. The current at the surface consists of the conduction current and a locally generated displacement current, which are often approximately equal in magnitude. A method of separating the two currents using two collectors of different geometry is investigated. The picoammeters connected to the collectors have a RC time constant of approximately 3 s, permitting the investigation of higher frequency air-earth current changes than previously achieved. The displacement current component of the air-earth current derived from the instrument agrees with calculations using simultaneous data from a co-located fast response electric field mill. The mean value of the nondisplacement current measured over 9 h was 1.76 +/- 0.002 pA m(-2). (c) 2006 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evidence is emerging for physical links among clouds, global temperatures, the global atmospheric electrical circuit and cosmic ray ionisation. The global circuit extends throughout the atmosphere from the planetary surface to the lower layers of the ionosphere. Cosmic rays are the principal source of atmospheric ions away from the continental boundary layer: the ions formed permit a vertical conduction current to flow in the fair weather part of the global circuit. Through the (inverse) solar modulation of cosmic rays, the resulting columnar ionisation changes may allow the global circuit to convey a solar influence to meteorological phenomena of the lower atmosphere. Electrical effects on non-thunderstorm clouds have been proposed to occur via the ion-assisted formation of ultra-fine aerosol, which can grow to sizes able to act as cloud condensation nuclei, or through the increased ice nucleation capability of charged aerosols. Even small atmospheric electrical modulations on the aerosol size distribution can affect cloud properties and modify the radiative balance of the atmosphere, through changes communicated globally by the atmospheric electrical circuit. Despite a long history of work in related areas of geophysics, the direct and inverse relationships between the global circuit and global climate remain largely quantitatively unexplored. From reviewing atmospheric electrical measurements made over two centuries and possible paleoclimate proxies, global atmospheric electrical circuit variability should be expected on many timescales

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a new satellite mission to deliver high quality measurements of upper air water vapour. The concept centres around a LiDAR in limb sounding by occultation geometry, designed to operate as a very long path system for differential absorption measurements. We present a preliminary performance analysis with a system sized to send 75 mJ pulses at 25 Hz at four wavelengths close to 935 nm, to up to 5 microsatellites in a counter-rotating orbit, carrying retroreflectors characterized by a reflected beam divergence of roughly twice the emitted laser beam divergence of 15 µrad. This provides water vapour profiles with a vertical sampling of 110 m; preliminary calculations suggest that the system could detect concentrations of less than 5 ppm. A secondary payload of a fairly conventional medium resolution multispectral radiometer allows wide-swath cloud and aerosol imaging. The total weight and power of the system are estimated at 3 tons and 2,700 W respectively. This novel concept presents significant challenges, including the performance of the lasers in space, the tracking between the main spacecraft and the retroreflectors, the refractive effects of turbulence, and the design of the telescopes to achieve a high signal-to-noise ratio for the high precision measurements. The mission concept was conceived at the Alpbach Summer School 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Considerable efforts are currently invested into the setup of a Global Climate Observing System (GCOS) for monitoring climate change over the coming decades, which is of high relevance given concerns on increasing human influences. A promising potential contribution to the GCOS is a suite of spaceborne Global Navigation Satellite System (GNSS) occultation sensors for global long-term monitoring of atmospheric change in temperature and other variables with high vertical resolution and accuracy. Besides the great importance with respect to climate change, the provision of high quality data is essential for the improvement of numerical weather prediction and for reanalysis efforts. We review the significance of GNSS radio occultation sounding in the climate observations context. In order to investigate the climate change detection capability of GNSS occultation sensors, we are currently performing an end-to-end GNSS occultation observing system simulation experiment over the 25-year period 2001 to 2025. We report on this integrated analysis, which involves in a realistic manner all aspects from modeling the atmosphere via generating a significant set of stimulated measurements to an objective statistical analysis and assessment of 2001–2025 temporal trends.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is proposed for merging different nadir-sounding climate data records using measurements from high-resolution limb sounders to provide a transfer function between the different nadir measurements. The two nadir-sounding records need not be overlapping so long as the limb-sounding record bridges between them. The method is applied to global-mean stratospheric temperatures from the NOAA Climate Data Records based on the Stratospheric Sounding Unit (SSU) and the Advanced Microwave Sounding Unit-A (AMSU), extending the SSU record forward in time to yield a continuous data set from 1979 to present, and providing a simple framework for extending the SSU record into the future using AMSU. SSU and AMSU are bridged using temperature measurements from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS), which is of high enough vertical resolution to accurately represent the weighting functions of both SSU and AMSU. For this application, a purely statistical approach is not viable since the different nadir channels are not sufficiently linearly independent, statistically speaking. The near-global-mean linear temperature trends for extended SSU for 1980–2012 are −0.63 ± 0.13, −0.71 ± 0.15 and −0.80 ± 0.17 K decade−1 (95 % confidence) for channels 1, 2 and 3, respectively. The extended SSU temperature changes are in good agreement with those from the Microwave Limb Sounder (MLS) on the Aura satellite, with both exhibiting a cooling trend of ~ 0.6 ± 0.3 K decade−1 in the upper stratosphere from 2004 to 2012. The extended SSU record is found to be in agreement with high-top coupled atmosphere–ocean models over the 1980–2012 period, including the continued cooling over the first decade of the 21st century.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into quasi-modes a, b and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Foi desenvolvido um estudo da subsuperfície rasa para investigar a possibilidade de contaminação do subsolo por líquidos usados no tratamento de couros em área industrial. O estudo foi realizado na área da indústria Couro do Norte, Bairro de Maracacuera, no Distrito Industrial de Icoaraci (município de Belém-Pará). Durante o estudo foram feitas medidas para a determinação do fluxo de água do primeiro aqüífero e aplicada metodologia geofísica com a finalidade de detectar a possível contaminação do subsolo por poluentes liberados pelo curtume. As metodologias geofísicas utilizadas foram: eletrorresistividade (na forma de imageamento e través de sondagens verticais), potencial espontâneo, eletromagnético (Slingram) e radar de penetração no solo (GPR). A interpretação dos dados eletromagnéticos permitiu identificar a presença de zonas mais condutivas (provável pluma de contaminação) e zonas mais resistivas (blocos lateríticos). A distribuição dos potenciais medidos através do Método do Potencial Espontâneo indicou o sentido do fluxo subterrâneo local. Com as Sondagens Elétricas Verticais determinaram-se os valores de resistividade em subsuperfície para os diferentes horizontes correlacionando-os sempre com as informações obtidas no Caminhamento Elétrico. Através dos dados de GPR identificou-se a presença de blocos lateríticos, tubulações de metal e zonas com elevada atenuação (zona de sombra) que indicam a presença de contaminação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A partir de 1974, quando da implantação do Núcleo de Ciências Geofísicas e Geológicas da UFPa., começou a ser desenvolvido um estudo de água subterrânea na Ilha do Marajó, sob o titulo de Projeto Marajó, financiado pela FINEP, que visava definir e delinear aquíferos em algumas áreas piloto da ilha. Este trabalho, realizado em uma dessas áreas piloto, no município de Salvaterra, Marajó, busca determinar áreas favoráveis para exploração de água subterrânea, através do uso do método geofísico de eletroresistividade. A área, de 200 Km2, foi prospectada através de 65 sondagens elétricas verticais e 6 perfilagens horizontais, tendo sido utilizado o dispositivo Schlumberger nas sondagens e o dispositivo Wenner nas perfilagens. Os dados foram inicialmente interpretados através do método do Ponto Auxiliar, quando se obteve uma visão geral do comportamento resistivo dos terrenos sondados, sendo depois reinterpretados usando técnica computacional, indicando existir na área camadas com resistividades que variam desde 5 até 43000 ohms-metro. Observou-se a existência de um pacote formado por uma sucessão de camadas que apresentaram resistividades com valores de 500 a 4000 ohms-metro, interpretado como constituído de sedimentos arenosos com água doce (aquífero), tendo uma espessura que chegou a atingir mais de 60 metros em algumas áreas. Na área pesquisada, foram delimitadas três sub-áreas cobrindo cerca de 40% da área total e, nestas, as espessuras do aquífero vão de 20 a 80 metros. As profundidades do topo desse aquífero nas três sub-áreas variam de 1,3 a 6,6 metros. A interpretação geofísica foi comprovada através de quatro furos de sondagem até 20 metros. Dois destes furos, realizados nas áreas interpretadas como bons aquíferos, mostraram terrenos mais arenosos, e os outros dois, alotados fora daquelas áreas, apresentaram uma parcela considerável de sedimentos argilosos com algum material orgânico. Informações obtidas quando do levantamento dos poços escavados na região e das análises de amostras das águas destes poços, mostram que, em termos gerais, não existem problemas quanto à qualidade das águas desses aquíferos mais superficiais, com exceção de dois poços escavados muito próximos da borda da Baía do Marajó, nas localidades de Joanes e Monsarás, que apresentam um aumento na salinidade quando no pico da estação de estio. Pelo que foi visto, o método utilizado neste trabalho é uma técnica eficiente para localizar bons aquíferos em ambientes geológicos semelhantes ao da área pesquisada.