974 resultados para ventilation radiator
Resumo:
Purpose: To evaluate the use of high frequency jet ventilation (HFJV) in patients undergoing percutanous thermal ablation procedures.Materials: From may to september 2011 patients with lung, liver or kidney tumors suitable for percutanous thermal ablation were prospectively enrolled to be treated under general anesthesia using HFJV instead of conventional positive pressure ventilation (PPV). Our primary endpoint was feasability of HFJV during percutanous ablation, our secondary endpoints were assessment of breathing related movements by image fusion (CT/US), precision and ease of needle placement by number of CT aquisition/needle reposition and procedure related complications.Results: Twenty-nine patients (21 males, 8 females mean age 66.2 years) with 30 liver tumors, 1 kidney tumors and 6 lung tumors were included. Tumor ablation was performed by radiofrequency (RFA) in 26 cases, microwaves ( MWA) in 2 and cryoablation (CRA) in 1. The ablation procedure could be completed under HFJV in 22 patients. In 2 patients HFVJ had to be stopped in favor of PPV because the tumor was better seen under PPV. HFJV was not performed in 5. Breathing related movements of the target lesion in the cranio-caudal direction as estimated by image fusion were always inferior to 5mm compared to 20mm when patients are under PPV. Needle placement was straightforward under CT as well as US. No patient needed needle repositionning before ablation. We did not observe any HFJV related complications.Conclusions: HFJV significantly reduces breathing movements of target lesion during percutaneous ablation procedures. It does not seem to cause any particular complication. However in some cases such as tumors located at the base of the lungs or in the dome of the liver, the target may be best seen under PPV.
Resumo:
Introduction Because it decreases intubation rate and mortality, NIV has become first-line treatment in case of hypercapnic acute respiratory failure (HARF). Whether this approach is equally successful for all categories of HARF patients is however debated. We assessed if any clinical characteristics of HARF patients were associated with NIV intensity, success, and outcome, in order to identify prognostic factors. Methods Retrospective analysis of the clinical database (clinical information system and MDSi) of patients consecutively admitted to our medico-surgical ICU, presenting with HARF (defined as PaCO2 > 50 mmHg), and receiving NIV between May 2008 and December 2010. Demographic data, medical diagnoses (including documented chronic lung disease), reason for ICU hospitalization, recent surgical interventions, SAPS II and McCabe scores were extracted from the database. Total duration of NIV and the need for tracheal intubation during the 5 days following the first hypercapnia documentation, as well as ICU, hospital and one year mortality were recorded. Results are reported as median [IQR]. Comparisons were carried out with Chi2 or Kruskal-Wallis tests, p<0.05 (*). Results Two hundred and twenty patients were included. NIV successful patients received 16 [9-31] hours of NIV for up to 5 days. Fifty patients (22.7%) were intubated 11 [2-34] hours after HARF occurence, after having receiving 10 [5-21] hours of NIV. Intubation was correlated with increased ICU (18% vs. 6%, p<0.05) and hospital (42% vs. 31%, p>0.05) mortality. SAPS II score was related to increasing ICU (51 [29-74] vs. 23 [12-41]%, p<0.05), hospital (37% [20-59] vs 20% [12-37], p<0.05) and one year mortality (35% vs 20%, p<0.05). Surgical patients were less frequent among hospital fatalities (28.8% vs. 46.3%, p<0.05, RR 0.8 [0-6-0.9]). Nineteen patients (8.6%) died in the ICU, 73 (33.2%) during their hospital stay and 108 (49.1%) were dead one year after HARF. Conclusion The practice to start NIV in all suitable patients suffering from HARF is appropriate. NIV can safely and appropriately be used in patients suffering from HARF from an origin different from COPD exacerbation. Beside usual predictors of severity such as severity score (SAPS II) appear to be associated with increased mortality. Although ICU mortality was low in our patients, hospital and one year mortality were substantial. Surgical patients, although undergoing a similar ICU course, had a better hospital and one year outcome.
Resumo:
BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.
Resumo:
Mechanical ventilation (MV) is life-saving but potentially harmful for lungs of premature infants. So far, animal models dealt with the acute impact of MV on immature lungs, but less with its delayed effects. We used a newborn rodent model including non-surgical and therefore reversible intubation with moderate ventilation and hypothesized that there might be distinct gene expression patterns after a ventilation-free recovery period compared to acute effects directly after MV. Newborn rat pups were subjected to 8 hr of MV with 60% oxygen (O(2) ), 24 hr after injection of lipopolysaccharide (LPS), intended to create a low inflammatory background as often recognized in preterm infants. Animals were separated in controls (CTRL), LPS injection (LPS), or full intervention with LPS and MV with 60% O(2) (LPS + MV + O(2) ). Lungs were recovered either directly following (T:0 hr) or 48 hr after MV (T:48 hr). Histologically, signs of ventilator-induced lung injury (VILI) were observed in LPS + MV + O(2) lungs at T:0 hr, while changes appeared similar to those known from patients with chronic lung disease (CLD) with fewer albeit larger gas exchange units, at T:48 hr. At T:0 hr, LPS + MV + O(2) increased gene expression of pro-inflammatory MIP-2. In parallel anti-inflammatory IL-1Ra gene expression was increased in LPS and LPS + MV + O(2) groups. At T:48 hr, pro- and anti-inflammatory genes had returned to their basal expression. MMP-2 gene expression was decreased in LPS and LPS + MV + O(2) groups at T:0 hr, but no longer at T:48 hr. MMP-9 gene expression levels were unchanged directly after MV. However, at T:48 hr, gene and protein expression increased in LPS + MV + O(2) group. In conclusion, this study demonstrates the feasibility of delayed outcome measurements after a ventilation-free period in newborn rats and may help to further understand the time-course of molecular changes following MV. The differences obtained from the two time points could be interpreted as an initial transitory increase of inflammation and a delayed impact of the intervention on structure-related genes. Pediatr Pulmonol. 2012; 47:1204-1214. © 2012 Wiley Periodicals, Inc.
Resumo:
RESUME : L'application d'une ventilation non-invasive (VNI) à pression positive chez des patients avec une insuffisance respiratoire aiguë hypoxémique non liée à une broncho-pneumopathie chronique obstructive (BPCO), reste controversée malgré les résultats encourageants apparus dans de récentes études. Ce travail de thèse est composé d'une introduction qui comprend un historique de la VNI et une revue de ces applications principales dans l'insuffisance respiratoire aiguë avec, en particulier, une analyse des études cliniques principales concernant son utilisation dans l'exacerbation de la BPCO, dans l'asthme aigu sévère, dans les syndromes restrictifs et dans l'insuffisance respiratoire aiguë hypoxémique. La première partie aborde également les aspects pratiques de l'utilisation de la VNI, avec une description de l'équipement et des techniques utilisées. Ce travail de thèse a ensuite pour but d'analyser dans une étude personnelle l'application d'une VNI à pression positive chez des patients avec une insuffisance respiratoire aiguë hypoxémique non liée à une BPCO. Il s'agit d'une étude prospective et observationnelle, dans laquelle nous avons voulu analyser l'efficacité de la VNI chez un groupe de patients sélectionnés et coopérants, stables du point de vue hémodynamique, présentant un syndrome de détresse respiratoire aiguë (SDRA) primaire (atteinte pulmonaire directe). Les échanges gazeux, le taux d'intubation, la mortalité et la durée de séjour dans l'unité de soins intensifs ont été enregistrés. Dans notre travail, la VNI a été appliquée de manière prospective à 12 patients, stables du point de vue hémodynamique, présentant les critères diagnostiques pour un SDRA primaire (SDRAP) et une indication pour une ventilation mécanique classique. Leur évolution a été comparée avec celle d'un groupe contrôle de 12 patients avec SDRAP. et précédemment traités dans la même unité de soins intensifs, ayant des caractéristiques similaires à l'admission : âge, score SAPS II, rapport Pa02/Fi02 et valeurs de pH . Un échec de la VNI fut observé chez 4 patients (33%), tous bactériémiques et nécessitant une intubation endotrachéale. Un facteur prédictif négatif. Les patients traités avec succès ont présenté un temps cumulatif de ventilation (p=0.001) et une durée de séjour aux soins intensifs (p=0.004) inférieure à ceux du groupe contrôle. Pendant la première période d'observation de la ventilation, l'oxygénation après 60 minutes s'est améliorée de manière plus importante dans le groupe VNI par rapport au groupe contrôle (PaO2/FiO2 : 146 +/- 52 mmHg vs. 109 +/- 34 mmHg ; p=0.05). Le taux de mortalité globale aux soins intensifs ne fut pas différent entre le groupe VNI et le groupe de patients intubés. Le taux de complications graves fut plus élevé chez les patients du groupe contrôle. Nos résultats suggèrent que chez des patients stables et coopérants, avec une pneumonie étendue, sans bactériémie à l'admission et remplissant les critères diagnostiques d'un SDRAp, la VNI représente une alternative valable à l'intubation endotrachéale.
Resumo:
INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.
Resumo:
BACKGROUND: Observational studies on mechanical ventilation (MV) show practice variations across ICUs. We sought to determine, with a case-vignette study, the heterogeneity of processes of care in ICUs focusing on mechanical ventilation procedures, and whether organizational patterns or physician characteristics influence practice variations. METHODS: We conducted a cross-sectional multicenter study using the case-vignette methodology. Descriptive analyses were calculated for each organizational pattern and respondent characteristics. An Index of Qualitative Variation (IQV, from 0, no heterogeneity, to a maximum of 1) was calculated. RESULTS: Forty ICUs from France (N = 33) and Switzerland (N = 7) participated; 396 physicians answered our case-vignettes. There was major heterogeneity of management processes related to MV within and across centers (mean IQV per center 0.51, SD 0.09). We observed the lowest variability (mean IQV per question < 0.4) for questions related to intubation procedure, ventilation of acute respiratory distress syndrome and the use of the semirecumbent position. We observed a high variability (mean IQV per question > 0.6) for questions related to management of endotracheal tube or suctioning, management of sedation and analgesia, and respect of autonomy. Heterogeneity was independent of respondent characteristics and of the presence of written procedures. There was a correlation between the processes associated with the highest variability (mean IQV per question > 0.6) and the annual volume of ICU admission (r = 0.32 (0.01 to 0.58)) and MV (r = 0.38 (0.07 to 0.63)). Within ICUs there was a large heterogeneity regarding knowledge of a local written procedure. CONCLUSIONS: Large clinical practice variations were found among ICUs. High volume centers were more likely to have heterogeneous practices. The presence of a local written procedure or respondent characteristics did not influence practice variation.
Resumo:
OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.
Resumo:
OBJECTIVE: To evaluate the influence of nursing on the duration of weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease. DESIGN: Data were collected prospectively over a 1-yr period (study year) and compared with previously collected prospective data recorded in our chronic obstructive pulmonary disease database during a 5-yr period. SETTING: The medical intensive care unit (ICU) of a university hospital. PATIENTS: Eighty-seven patients with chronic obstructive pulmonary disease. Fifteen patients had chronic obstructive pulmonary disease that required mechanical ventilation for acute exacerbation of their disease (study year), and 72 were patients with chronic obstructive pulmonary disease from the previously collected data. INTERVENTIONS: The ICU course (duration of mechanical ventilation, mortality) was recorded, as well as several respiratory parameters (pulmonary function tests and arterial blood gases in stable conditions, and nutritional status), and they were compared with an "index of nursing." MEASUREMENTS AND MAIN RESULTS: We developed an "index of nursing", comparing the effective workforce of the nurses (number and qualifications) with the ideal workforce required by the number of patients and the severity of their diseases. A value of 1.0 represented a perfect match between the needed and the effectively present nurses, whereas a lesser value signified a diminished available workforce. This index was compared with the complications and duration of weaning from mechanical ventilation. During the first 5 yrs, the duration of mechanical ventilation increased progressively from 7.3 +/- 8.0 to 38.2 +/- 25.8 days (p = .006). A significant inverse correlation between the duration of mechanical ventilation and the nursing index (p = .025) was found. In the sixth comparative year, the number of nurses increased (nursing index = 1.05) and the duration of mechanical ventilation decreased to 9.9 +/- 13 days (p < .001, yr 5 vs. yr 6). CONCLUSIONS: The quality of nursing appears to be a measurable and critical factor in the weaning from mechanical ventilation of patients with chronic obstructive pulmonary disease. Below a threshold in the available workforce of ICU nurses, the weaning duration of patients with chronic obstructive pulmonary disease increases dramatically. Therefore, very close attention should be given to the education and number of ICU nurses.
Resumo:
Introduction: Because it decreases intubation rate and mortality, NIV has become first-line treatment in case of hypercapnic respiratory failure (HRF). Whether this approach is equally successful for all categories of HRF patients is however debated. We assessed if any clinical characteristics of HRF patients were associated with NIV intensity, success, and outcome, in order to identify prognostic factors. Methods: Retrospective analysis of the clinical database (clinical information system and MDSi) of patients consecutively admitted to our medico-surgical ICU, presenting with HRF (defined as PaCO2 >50 mm Hg), and receiving NIV between January 2009 and December 2010. Demographic data, medical diagnoses (including documented chronic lung disease), reason for ICU hospitalization, recent surgical interventions, SAPS II and McCabe scores were extracted from the database. Total duration of NIV and the need for tracheal intubation during the 5 days following the first hypercapnia documentation, as well as ICU and hospital mortality were recorded. Results are reported as median [IQR]. Comparisons with Chi2 or Kruskal-Wallis tests, p <0.05 (*). Results: 164 patients were included, 45 (27.4%) of whom were intubated after 10 [2-34] hours, after having received 7 [2-19] hours of NIV. NIV successful patients received 15 [5-22] hours of NIV for up to 5 days. Intubation was correlated with increased ICU (20% vs. 3%, p <0.001) and hospital (46.7% vs. 30.2, p >0.05) mortality. Conclusions: A majority of patients requiring NIV for hypercapnic respiratory failure in our ICU have no diagnosed chronic pulmonary disease. These patients tend to have increased ICUand hospital mortality. The majority of patients were non-surgical, a feature correlated with increased hospital mortality. Beside usual predictors of severity such as age and SAPS II, absence of diagnosed chronic pulmonary disease and non-operative state appear to be associated with increased mortality. Further studies should explore whether these patients are indeed more prone to an adverse outcome and which therapeutic strategies might contribute to alter this course.