964 resultados para true isidium
Resumo:
The goal of this research was to investigate the changes in neural processing in mild cognitive impairment. We measured phase synchrony, amplitudes, and event-related potentials in veridical and false memory to determine whether these differed in participants with mild cognitive impairment compared with typical, age-matched controls. Empirical mode decomposition phase locking analysis was used to assess synchrony, which is the first time this analysis technique has been applied in a complex cognitive task such as memory processing. The technique allowed assessment of changes in frontal and parietal cortex connectivity over time during a memory task, without a priori selection of frequency ranges, which has been shown previously to influence synchrony detection. Phase synchrony differed significantly in its timing and degree between participant groups in the theta and alpha frequency ranges. Timing differences suggested greater dependence on gist memory in the presence of mild cognitive impairment. The group with mild cognitive impairment had significantly more frontal theta phase locking than the controls in the absence of a significant behavioural difference in the task, providing new evidence for compensatory processing in the former group. Both groups showed greater frontal phase locking during false than true memory, suggesting increased searching when no actual memory trace was found. Significant inter-group differences in frontal alpha phase locking provided support for a role for lower and upper alpha oscillations in memory processing. Finally, fronto-parietal interaction was significantly reduced in the group with mild cognitive impairment, supporting the notion that mild cognitive impairment could represent an early stage in Alzheimer’s disease, which has been described as a ‘disconnection syndrome’.
When writing the other is being true to the self: Jamaica Kincaid's 'The Autobiography of My Mother'
Resumo:
We do live in interesting times, don’t we? This is especially true of those of us who spend most of our working lives in libraries. The last ten years have been so filled with change that it’s almost become a byword: if you don’t like something, just wait a few hours and it will change. This isn’t a complaint, just an observation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The authors verified the anatomical location of the mandibular foramen, lingula and antilingula in dry mandibles, aiming to obtain information that could be used when performing mandibular osteotomies. Forty-four mandibles (88 sides) were evaluated. The distances were measured using a sliding calliper, with the mandibles fixed in a reproducible position. Results showed that the mandibular foramen is on average 5.82 mm below the lingula. Regarding the statistical comparison between the mandibular foramen entrance and the anti lingula position, there is no correlation between the position of those two structures in the studied sample. The mandibular foramen is slightly posterior in relation to the centre of the ramus. The lingula is an important anatomic landmark for ramus surgery, and for determining the distance to the mandibular foramen entrance. The use of the antilingula as a landmark for the position of the vertical ramus osteotomy is not recommended.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We investigate, through the density-matrix renormalization group and the Lanczos technique, the possibility of a two-leg Kondo ladder presenting an incommensurate orbital order. Our results indicate staggered short-range orbital order at half-filling. Away from half-filling our data are consistent with incommensurate quasi-long-range orbital order. We also observed that an interaction between the localized spins enhances the rung-rung current correlations.
Resumo:
In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. The proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. Finally, the proposed control strategy is verified through experimental results from an implemented prototype. ©2008 IEEE.