932 resultados para tensor reconstruction
Resumo:
Pectus excavatum is the most common congenital deformity of the anterior thoracic wall. The surgical correction of such deformity, using Nuss procedure, consists in the placement of a personalized convex prosthesis into sub-sternal position to correct the deformity. The aim of this work is the CT-scan substitution by ultrasound imaging for the pre-operative diagnosis and pre-modeling of the prosthesis, in order to avoid patient radiation exposure. To accomplish this, ultrasound images are acquired along an axial plane, followed by a rigid registration method to obtain the spatial transformation between subsequent images. These images are overlapped to reconstruct an axial plane equivalent to a CT-slice. A phantom was used to conduct preliminary experiments and the achieved results were compared with the corresponding CT-data, showing that the proposed methodology can be capable to create a valid approximation of the anterior thoracic wall, which can be used to model/bend the prosthesis
Resumo:
Background: An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). Methods: A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. Conclusions: The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde.
Resumo:
Fluorescence confocal microscopy (FCM) is now one of the most important tools in biomedicine research. In fact, it makes it possible to accurately study the dynamic processes occurring inside the cell and its nucleus by following the motion of fluorescent molecules over time. Due to the small amount of acquired radiation and the huge optical and electronics amplification, the FCM images are usually corrupted by a severe type of Poisson noise. This noise may be even more damaging when very low intensity incident radiation is used to avoid phototoxicity. In this paper, a Bayesian algorithm is proposed to remove the Poisson intensity dependent noise corrupting the FCM image sequences. The observations are organized in a 3-D tensor where each plane is one of the images acquired along the time of a cell nucleus using the fluorescence loss in photobleaching (FLIP) technique. The method removes simultaneously the noise by considering different spatial and temporal correlations. This is accomplished by using an anisotropic 3-D filter that may be separately tuned in space and in time dimensions. Tests using synthetic and real data are described and presented to illustrate the application of the algorithm. A comparison with several state-of-the-art algorithms is also presented.
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.
Resumo:
Brain dopamine transporters imaging by Single Photon Emission Tomography (SPECT) with 123I-FP-CIT has become an important tool in the diagnosis and evaluation of parkinsonian syndromes, since this radiopharmaceutical exhibits high affinity for membrane transporters responsible for cellular reabsorption of dopamine on the striatum. However, Ordered Subset Expectation Maximization (OSEM) is the method recommended in the literature for imaging reconstruction. Filtered Back Projection (FBP) is still used due to its fast processing, even if it presents some disadvantages. The aim of this work is to investigate the influence of reconstruction parameters for FBP in semiquantification of Brain Studies with 123I-FPCIT compared with those obtained with OSEM recommended reconstruction.
Resumo:
The main goal of the present work is the use of mineralogical data corresponding to sediment fine fractions (silt and clay) of Quaternary littoral deposits for the definition of a more detailed vertical zonography and to discriminate the most significant morphoclimatic changes concerned with sediment source areas and sediment deposition areas. The analysis of the available mineralogical data reveals a vertical evolution of the mineral composition. The following aspects deserve particular reference: 1) fine fractions (<38 nm) are composed of quartz and phyllosilicates associated to feldspars, prevailing over other minerals; however in certain sections iron hydroxides and evaporitic minerals occur in significant amounts; 2) clay fractions (<2 nm) show a general prevalence of illite associated with kaolinite and oscillations, in relative terms, of kaolinite and illite contents. Qualitative and quantitative lateral and vertical variations of clay and non clay minerals allow the discrimination of sedimentary sequences and the establishment of the ritmicity and periodicity of the morphoclimatic Quaternary episodes that occurred in the Cortegaça and Maceda beaches. To each one of the sedimentary sequences corresponds, in a first stage, a littoral environment that increasingly became more continental. Climate would be mild to cold, sometimes with humidity - aridity oscillations. Warmer and moister episodes alternated with cooler and dryer ones.
Resumo:
Upper eyelid tumours, particularly basal cell carcinomas, are relatively frequent. Surgical ablation of these lesions creates defects of variable complexity. Although several options are available for lower eyelid reconstruction, fewer surgical alternatives exist for upper eyelid reconstruction. Large defects of this region are usually reconstructed with two-step procedures. In 1997, Okada et al. described a horizontal V-Y myotarsocutaneous advancement flap for reconstruction of a large upper eyelid defect in a single operative time. However, no further studies were published regarding the use of this particular flap in upper eyelid reconstruction. In addition, this flap is not described in most plastic surgery textbooks. The authors report here their experience of 16 cases of horizontal V-Y myotarsocutaneous advancement flaps used to reconstruct full-thickness defects of the upper eyelid after tumour excision. The tumour histological types were as follows: 12 basal cell carcinomas, 2 cases of squamous cell carcinomas, 1 case of sebaceous cell carcinoma and 1 of malignant melanoma. This technique allowed closure of defects of up to 60% of the eyelid width. None of the flaps suffered necrosis. The mean operative time was 30 min. No additional procedures were necessary as good functional and cosmetic results were achieved in all cases. No recurrences were noted. In this series, the horizontal V-Y myotarsocutaneous advancement flap proved to be a technically simple, reliable and expeditious option for reconstruction of full-thickness upper eyelid defects (as wide as 60% of the eyelid width) in a single operative procedure. In the future this technique may become the preferential option for such defects.
Resumo:
In cases of extensive damage to the foot, with significant bone loss, it is generally accepted that reconstruction must include bone flaps or grafts either in the emergency setting or subsequently. In this report, we describe the case of an 18-year-old student with an avulsion injury of the dorsum of his right foot. Consequently, he lost most of the soft tissue over the dorsum of the foot and the cuboid, navicular, and cuneiform bones. A latissimus dorsi free flap was used to reconstruct the defect. A functional pseudoarthrosis developed between the remaining bones of the foot, and the patient experienced satisfactory foot function after rehabilitation. For this reason, no additional reconstructive procedure was undertaken. This case suggests that it might be adequate to use the latissimus dorsi muscle flap more liberally than previously reported in the reconstruction of extensive defects of the dorsum of the foot, including cases with significant bone loss. This option could avoid the morbidity and inconvenience of a second surgery and the need to harvest a bone flap or graft.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Breast cancer is the most common cancer among women, being a major public health problem. Worldwide, X-ray mammography is the current gold-standard for medical imaging of breast cancer. However, it has associated some well-known limitations. The false-negative rates, up to 66% in symptomatic women, and the false-positive rates, up to 60%, are a continued source of concern and debate. These drawbacks prompt the development of other imaging techniques for breast cancer detection, in which Digital Breast Tomosynthesis (DBT) is included. DBT is a 3D radiographic technique that reduces the obscuring effect of tissue overlap and appears to address both issues of false-negative and false-positive rates. The 3D images in DBT are only achieved through image reconstruction methods. These methods play an important role in a clinical setting since there is a need to implement a reconstruction process that is both accurate and fast. This dissertation deals with the optimization of iterative algorithms, with parallel computing through an implementation on Graphics Processing Units (GPUs) to make the 3D reconstruction faster using Compute Unified Device Architecture (CUDA). Iterative algorithms have shown to produce the highest quality DBT images, but since they are computationally intensive, their clinical use is currently rejected. These algorithms have the potential to reduce patient dose in DBT scans. A method of integrating CUDA in Interactive Data Language (IDL) is proposed in order to accelerate the DBT image reconstructions. This method has never been attempted before for DBT. In this work the system matrix calculation, the most computationally expensive part of iterative algorithms, is accelerated. A speedup of 1.6 is achieved proving the fact that GPUs can accelerate the IDL implementation.
Resumo:
A simulação dinâmica de reservatórios de petróleo requer a alocação de permeabilidades equivalentes para todos os blocos. A determinação da permeabilidade equivalente em reservatórios fraturados é uma questão complexa e crítica no fluxograma de modelação, porque é totalmente dependente da geometria 3D sistema de fraturas, e respetivas aberturas, que muitas vezes são mal conhecidos. Para avaliar a permeabilidade equivalente de blocos fraturados, o método do tensor ou de Oda é um dos mais utilizados. É expedito e eficiente mesmo para a sistemas com vários milhões de fraturas. Todavia, na literatura são apontadas algumas críticas, por exemplo, sobrestima a permeabilidade em blocos pouco fraturados e subestima-a em blocos muito fraturados. Este trabalho tem como objetivos, revisitar a problemática da caracterização da permeabilidade equivalente em blocos de reservatórios fraturados. Recorreu-se a um pacote de programas informáticos FROM3D-K (fractures object model – permeability evaluation) desenvolvidos e/ ou adaptados no contexto deste trabalho e que permitem as funcionalidades: (1) simulação estocástica 3D de fraturas; (2) determinação da permeabilidade equivalente pelo método do tensor; (3) determinação da permeabilidade equivalente pelo método de upscaling de microblocos. Estas funções permitem que a mesma rede de fraturas seja avaliada pelos dois métodos. Para a demonstração de resultados mostram-se dois exemplos, o primeiro onde são simuladas fraturas condicionadas a estatísticas sintéticas de orientação, intensidade e abertura e o segundo onde se utilizam dados FMI de poço de um reservatório fraturado.