926 resultados para standard vector control scheme


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the topology selection, design steps, simulation studies, design verification, system fabrication and performance evaluation on an induction motor based dynamometer system. The control algorithm used the application is well known field oriented control or vector control. Position sensorless scheme is adopted to eliminate the encoder requirement. The dynamometer is rated for 3.7kW. It can be used to determine the speed–torque characteristics of any rotating system. The rotating system is to be coupled with the vector controlled drive and the required torque command is given from the latter. The experimental verification is carried out for an open loop v/f drive as a test rotating system and important test results are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the method of field orientation of the stator current vector with respect to the stator, mutual, and rotor flux vectors, for the control of an induction motor fed from a current source inverter (CSI). A control scheme using this principle is described for orienting the stator current with respect to the rotor flux, as this gives natural decoupling between the current coordinates. A dedicated micro-computer system developed for implementing this scheme has been described. The experimental results are also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A torque control scheme, based on a direct torque control (DTC) algorithm using a 12-sided polygonal voltage space vector, is proposed for a variable speed control of an open-end induction motor drive. The conventional DTC scheme uses a stator flux vector for the sector identification and then the switching vector to control stator flux and torque. However, the proposed DTC scheme selects switching vectors based on the sector information of the estimated fundamental stator voltage vector and its relative position with respect to the stator flux vector. The fundamental stator voltage estimation is based on the steady-state model of IM and the synchronous frequency of operation is derived from the computed stator flux using a low-pass filter technique. The proposed DTC scheme utilizes the exact positions of the fundamental stator voltage vector and stator flux vector to select the optimal switching vector for fast control of torque with small variation of stator flux within the hysteresis band. The present DTC scheme allows full load torque control with fast transient response to very low speeds of operation, with reduced switching frequency variation. Extensive experimental results are presented to show the fast torque control for speed of operation from zero to rated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a multilevel flying capacitor inverter topology suitable for generating multilevel dodecagonal space vectors for an induction motor drive, is proposed. Because of the dodecagonal space vectors, it has increased modulation range with the absence of all 6n +/- 1, (n=odd) harmonics in the phase voltage and currents. The topology, realized by flying capacitor three level inverters feeding an open-end winding induction motor, does not suffer the neutral point voltage imbalance issues seen in NPC inverters and the capacitors have inherent charge-balancing capability with PWM control using switching state redundancies. Furthermore, the proposed technique uses lesser number of power supplies compared to cascaded H-bridge or NPC based dodecagonal schemes and has better ride-through capability. Finally, the voltage control is obtained through a simple carrier-based space vector PWM scheme implemented on a DSP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a multilevel dodecagonal voltage space vector structure with nineteen concentric dodecagons is proposed for the first time. This space vector structure is achieved by cascading two sets of asymmetric three-level inverters with isolated H-bridges on either side of an open-end winding induction motor. The dodecagonal structure is made possible by proper selection of dc link voltages and switching states of the inverters. The proposed scheme retains all the advantages of multilevel topologies as well as the advantages of dodecagonal voltage space vector structure. In addition to that, a generic and simple method for calculation of pulsewidth modulation timings using only sampled reference values (v(alpha) and v(beta)) is proposed. This enables the scheme to be used for any closed-loop application such as vector control. In addition, a new method of switching technique is proposed, which ensures minimum switching while eliminating the fifth-and seventh-order harmonics and suppressing the eleventh and thirteenth harmonics, eliminating the need for bulky filters. The motor phase voltage is a 24-stepped wave-form for the entire modulation range thereby reducing the number of switchings of the individual inverter modules. Experimental results for steady-state operation, transient operation, including start-up have been presented and the results of fast Fourier transform analysis is also presented for validating the proposed concept.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The efficiency of the wind power conversions systems can be greatly improved using an appropriate control algorithm. In this work, a sliding mode control for variable speed wind turbine that incorporates a doubly fed induction generator is described. The electrical system incorporates a wound rotor induction machine with back-to-back three phase power converter bridges between its rotor and the grid. In the presented design the so-called vector control theory is applied, in order to simplify the electrical equations. The proposed control scheme uses stator flux-oriented vector control for the rotor side converter bridge control and grid voltage vector control for the grid side converter bridge control. The stability analysis of the proposed sliding mode controller under disturbances and parameter uncertainties is provided using the Lyapunov stability theory. Finally simulated results show, on the one hand, that the proposed controller provides high-performance dynamic characteristics, and on the other hand, that this scheme is robust with respect to the uncertainties that usually appear in the real systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presentado en el 13th WSEAS International Conference on Automatic Control, Modelling and Simulation, ACMOS'11

Relevância:

100.00% 100.00%

Publicador:

Resumo:

EFTA 2009

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a real time sliding mode control scheme for a variable speed wind turbine that incorporates a doubly feed induction generator is described. In this design, the so-called vector control theory is applied, in order to simplify the system electrical equations. The proposed control scheme involves a low computational cost and therefore can be implemented in real-time applications using a low cost Digital Signal Processor (DSP). The stability analysis of the proposed sliding mode controller under disturbances and parameter uncertainties is provided using the Lyapunov stability theory. A new experimental platform has been designed and constructed in order to analyze the real-time performance of the proposed controller in a real system. Finally, the experimental validation carried out in the experimental platform shows; on the one hand that the proposed controller provides high-performance dynamic characteristics, and on the other hand that this scheme is robust with respect to the uncertainties that usually appear in the real systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Operation of induction machines in the high-speed and/or high-torque range requires field-weakening to comply with voltage and current physical limitations. This paper presents an anti-windup approach to this problem: rather than developing an ad-hoc field weakening strategy in the high-speed region, we equip an unconstrained vector-control design with an anti-windup module that automatically adjusts the current and flux set-points so that voltage and current constraints are satisfied at every operating point. The anti-windup module includes a feedforward modification of the set point aimed at maximizing the available torque in steady-state and a feedback modification of the controller based on an internal model-based antiwindup scheme. This paper includes a complete stability analysis of the proposed solution and presents encouraging experimental results on an industrial drive. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Integrated vector management (IVM) is increasingly being recommended as an option for sustainable malaria control. However, many malaria-endemic countries lack a policy framework to guide and promote the approach. The objective of the study was to assess knowledge and perceptions in relation to current malaria vector control policy and IVM in Uganda, and to make recommendations for consideration during future development of a specific IVM policy. METHODS: The study used a structured questionnaire to interview 34 individuals working at technical or policy-making levels in health, environment, agriculture and fisheries sectors. Specific questions on IVM focused on the following key elements of the approach: integration of chemical and non-chemical interventions of vector control; evidence-based decision making; inter-sectoral collaboration; capacity building; legislation; advocacy and community mobilization. RESULTS: All participants were familiar with the term IVM and knew various conventional malaria vector control (MVC) methods. Only 75% thought that Uganda had a MVC policy. Eighty percent (80%) felt there was inter-sectoral collaboration towards IVM, but that it was poor due to financial constraints, difficulties in involving all possible sectors and political differences. The health, environment and agricultural sectors were cited as key areas requiring cooperation in order for IVM to succeed. Sixty-seven percent (67%) of participants responded that communities were actively being involved in MVC, while 48% felt that the use of research results for evidence-based decision making was inadequate or poor. A majority of the participants felt that malaria research in Uganda was rarely used to facilitate policy changes. Suggestions by participants for formulation of specific and effective IVM policy included: revising the MVC policy and IVM-related policies in other sectors into a single, unified IVM policy and, using legislation to enforce IVM in development projects. CONCLUSION: Integrated management of malaria vectors in Uganda remains an underdeveloped component of malaria control policy. Cooperation between the health and other sectors needs strengthening and funding for MVC increased in order to develop and effectively implement an appropriate IVM policy. Continuous engagement of communities by government as well as monitoring and evaluation of vector control programmes will be crucial for sustaining IVM in the country.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Uganda, control of vector-borne diseases is mainly in form of vector control, and chemotherapy. There have been reports that acaricides are being misused in the pastoralist systems in Uganda. This is because of the belief by scientists that intensive application of acaricide is uneconomical and unsustainable particularly in the indigenous cattle. The objective of this study was to investigate the strategies, rationale and effectiveness of vector-borne disease control by pastoralists. To systematically carry out these investigations, a combination of qualitative and quantitative research methods was used, in both the collection and the analysis of data. Cattle keepers were found to control tick-borne diseases (TBDs) mainly through spraying, in contrast with the control of trypanosomosis for which the main method of control was by chemotherapy. The majority of herders applied acaricides weekly and used an acaricide of lower strength than recommended by the manufacturers. They used very little acaricide wash, and spraying was preferred to dipping. Furthermore, pastoralists either treated sick animals themselves or did nothing at all, rather than using veterinary personnel. Oxytetracycline (OTC) was the drug commonly used in the treatment of TBDs. Nevertheless, although pastoralists may not have been following recommended practices in their control of ticks and tick-borne diseases, they were neither wasteful nor uneconomical and their methods appeared to be effective. Trypanosomosis was not a problem either in Sembabule or Mbarara district. Those who used trypanocides were found to use more drugs than were necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a controller design scheme for a priori unknown non-linear dynamical processes that are identified via an operating point neurofuzzy system from process data. Based on a neurofuzzy design and model construction algorithm (NeuDec) for a non-linear dynamical process, a neurofuzzy state-space model of controllable form is initially constructed. The control scheme based on closed-loop pole assignment is then utilized to ensure the time invariance and linearization of the state equations so that the system stability can be guaranteed under some mild assumptions, even in the presence of modelling error. The proposed approach requires a known state vector for the application of pole assignment state feedback. For this purpose, a generalized Kalman filtering algorithm with coloured noise is developed on the basis of the neurofuzzy state-space model to obtain an optimal state vector estimation. The derived controller is applied in typical output tracking problems by minimizing the tracking error. Simulation examples are included to demonstrate the operation and effectiveness of the new approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS¡APPC). In the VS¡APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system