978 resultados para stability, cytotoxics, monitoring, HPLC, antibody


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study on the biomarkers types to assess health status of marine ecosystems in environmental biomonitoring has an important value. Accordingly, accumulation of polycyclic aromatic hydrocarbons(PAHs) in sediment, water and tissues (liver and gill) of mudskipper(i.e. Boleophthalmus dussumieri) and some physiological responses like lysosomal membrane change performed on haemocytes, stability of red blood cell membrane and the Glutathione-S Transferase (GST) activity in the liver were measured in mudskipper. Samples were obtained from five sites along north western coast of the Persian Gulf (Khuzestan coast). Red blood cell membrane changes after different concentration of PAHs at different time was also studied to evaluate impact of PAHs compound on cell membrane. PAHs concentration was measured by HPLC method. The activity of GST enzyme was analysed by spectrophotometric method. Lysosomal membrane change was measured by NRR time method and stability of red blood cell membrane was evaluated by EOF test. Total PAH concentrations in the coastal sea water, the sediments, the liver and the gill tissues ranged between 0.80-18.34 μg/l, 113.50-3384.34 ng g-1 (dry weight), 3.99-46.64 ng g-1 dw and 3.11-17.76 ng g-1 dw, respectively. Highest PAHs pollution was found at Jafari while the lowest was detected at Bahrakan sampling sites. The lowest enzymatic activity was identified at Bahrakan (7.19 ± 1.541 nmol/mg protein/min), while the highest was recorded at Jafari (46.96 ± 7.877 nmol/mg protein/min). Comparative analysis of GST activity in the liver of mudskippers showed significant difference (p < 0.05) between the locations of Jafari and Bahrakan, and with other sites. Moreover, no significant difference was detected between the locations of Arvand, Zangi and Samayeli (p < 0.05). The mean RT was below 90 minutes in all sampling sites. Values of mean RT of the dye ranged from 34 (for the blood samples of mudskipper collected from Jafari site) to 78 minutes (for the blood samples of mudskipper collected from Bahrakan site). Spatial evaluation revealed the longest RT in fish from Bahrakan as compared with those from other sites. Preliminary results showed a significant difference (p < 0.05) among sampling sites except between Arvand and Zangi (p > 0.05). Osmotic fragility curves indicated that erythrocytes collected from mudskippers at Jafari were the most 009 fragile followed by Zangi> Arvand> Samayeli> and Bahrakan. The mean erythrocyte fragility was significantly higher at Jafari site (p < 0.05) when compared to other sites. Significant differences were found between the various sites (p < 0.05).The result indicated no significant differences between the control and treatments of mudskipper RBC exposed to field concentrations of PAHs (P>0.05). The results further indicated significant differences (P<0.05) between the control and treatments of mudskipper RBC exposed to acute. Potency Divisor concentrations. It is clear from the present result that chronic. Potency Divisor concentrations protect red cells against osmotic hemolysis. This study, however, showed that PAH concentrations in this region are not higher than the available standards. The findings showed that Lysosomal membrane destabilization, liver GST activities and fragility of red cell membrane are highly sensitive in the mudskipper, B. dussumieri. Thus, mudskipper perceived to be good sentinel organisms for PAH pollution monitoring. Sediment PAH concentrations were strongly correlated with biomarkers, indicating that PAH type pollutants were biologically available to fish. One of the possible risk assessment implications of this study is that biomarkers can be applied not only to characterize biological effects of pollution exposures, but also to determine the bioavailability of pollution in aquatic systems. The results also indicated that PAHs compound possess anti haemolytic property.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies have reported that different schemes for coupling Monte Carlo (MC) neutron transport with burnup and thermal hydraulic feedbacks may potentially be numerically unstable. This issue can be resolved by application of implicit methods, such as the stochastic implicit mid-point (SIMP) methods. In order to assure numerical stability, the new methods do require additional computational effort. The instability issue however, is problem-dependent and does not necessarily occur in all cases. Therefore, blind application of the unconditionally stable coupling schemes, and thus incurring extra computational costs, may not always be necessary. In this paper, we attempt to develop an intelligent diagnostic mechanism, which will monitor numerical stability of the calculations and, if necessary, switch from simple and fast coupling scheme to more computationally expensive but unconditionally stable one. To illustrate this diagnostic mechanism, we performed a coupled burnup and TH analysis of a single BWR fuel assembly. The results indicate that the developed algorithm can be easily implemented in any MC based code for monitoring of numerical instabilities. The proposed monitoring method has negligible impact on the calculation time even for realistic 3D multi-region full core calculations. © 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Qinghai-Tibet Railway is the longest and highest plateau railway in the world. A long term monitoring system of the stability of the subgrade in the permafrost regions should be put forward immediately to prevent damage to the railway. As it's very difficult to set up the long-distance automatic monitoring system which contains a lot of measure points along the 550 kilometers railway in the permafrost area, we present a subgrade temperature monitor system based on fiber Bragg grating (FBG). In this paper the principles of the FBG was presented, and the feasibility of the FBG sensors in the permafrost area of Qinghai-Tibet plateau was analysized. We embedded fifteen FBG temperature sensors and thermal resistance temperature sensors. A contrast experiment is made while the two kinds of sensors are arranged in the same position. The result of the experiment shows that the accuracy of the FBG temperature sensors is less than 0.1 degrees C. and the FBG sensors can do well in the measurement of pattern which the temperature varies with the depth of the permafrost soil. The result also shows the stability of the FBG sensors in the bad environmental condition of Qinghai-Tibet plateau, which proves the feasibility of the application of FBG sensors and our monitoring system on the Qinghai-Tibet railway.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Circular dichoism and UV-vis measurements were used to study the interaction between porphyrin and monoclonal antibodies ( McAbs). McAbs-porphyrin complex formation is usually accompanied by significant bathochromic shift and hyperchromicity changes of the absorption maxima in the porphyrin soret band region. Induced CD spectra in the same region (350 similar to 450 nm) were detected upon complex formation. They follow Lamb-Beer's law and exhibit isosbestic behavior. Both the UV-Vis and induced CD spectra of the antibody: porphyrin complex remain unchanged over a broad pH range ( pH 6 similar to 11), indicating remarkable stability of the complex and reflecting the dominant role of hydrophobic interaction between the hapten benzophenone and the antibody combining site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

meso-Tetra (alpha, alpha, alpha, alpha-O-phenylacetyl benzene) porphyrin was used as a complete antigen to elicit monoclonal antibody 1F2 through the immunization and cell fusion techniques. McAb 1F2 obtained was demonstrated very pure by HPLC and MALDI/TOFMS. The retention time of McAb 1F2 was 2. 63 min. The subtype of McAb 1F2 was IgG2a. The relative molecular weight was 156 678. 8. When the McAb 1F2-porphyrin was formed, the maximal absorption of the porphyrin soret region had a redshift from 408 to 416 nm and hyperchromical effect, showing that the antigen-antibody combination was rigid and intense, and the abzyme constancy was high. But compared with HRP, the activity of the abzyme was only 4. 687 5 U/mg and 1. 899 % of that of HRP. Its K-m was 20. 29 mmol/L, k(cat) 396. 82 min(-1), k(cat)/K-m. 1. 955 7 X 10(4) L . mol(-1) . min(-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A number of different interferon-gamma ELISpot protocols are in use in laboratories studying antigen-specific immune responses. It is therefore unclear how results from different assays compare, and what factors most significantly influence assay outcome. One such difference is that some laboratories use a short in vitro stimulation period of cells before they are transferred to the ELISpot plate; this is commonly done in the case of frozen cells, in order to enhance assay sensitivity. Other differences that may be significant include antibody coating of plates, the use of media with or without serum, the serum source and the number of cells added to the wells. The aim of this paper was to identify which components of the different ELISpot protocols influenced assay sensitivity and inter-laboratory variation. Four laboratories provided protocols for quantifying numbers of interferon-gamma spot forming cells in human peripheral blood mononuclear cells stimulated with Mycobacterium tuberculosis derived antigens. The differences in the protocols were compared directly. We found that several sources of variation in assay protocols can be eliminated, for example by avoiding serum supplementation and using AIM-V serum free medium. In addition, the number of cells added to ELISpot wells should also be standardised. Importantly, delays in peripheral blood mononuclear cell processing before stimulation had a marked effect on the number of detectable spot forming cells; processing delay thus should be minimised as well as standardised. Finally, a pre-stimulation culture period improved the sensitivity of the assay, however this effect may be both antigen and donor dependent. In conclusion, small differences in ELISpot protocols in routine use can affect the results obtained and care should be given to conditions selected for use in a given study. A pre-stimulation step may improve the sensitivity of the assay, particularly when cells have been previously frozen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immunoglobulin superfamily (IgSF) domains are conserved structures present in many proteins in eukaryotes and prokaryotes. These domains are well-capable of facilitating sequence variation, which is most clearly illustrated by the variable regions in immunoglobulins (Igs) and T cell receptors (TRs). We studied an antibody-deficient patient suffering from recurrent respiratory infections and with impaired antibody responses to vaccinations. Patient's B cells showed impaired Ca(2+) influx upon stimulation with anti-IgM and lacked detectable CD19 membrane expression. CD19 sequence analysis revealed a homozygous missense mutation resulting in a tryptophan to cystein (W52C) amino acid change. The affected tryptophan is CONSERVED-TRP 41 located on the C-strand of the first extracellular IgSF domain of CD19 and was found to be highly conserved, not only in mammalian CD19 proteins, but in nearly all characterized IgSF domains. Furthermore, the tryptophan is present in all variable domains in Ig and TR and was not mutated in 117 Ig class-switched transcripts of B cells from controls, despite an overall 10% amino acid change frequency. In vitro complementation studies and CD19 western blotting of patient's B cells demonstrated that the mutated protein remained immaturely glycosylated. This first missense mutation resulting in a CD19 deficiency demonstrates the crucial role of a highly conserved tryptophan in proper folding or stability of IgSF domains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of blood spot collection cards is a simple way to obtain specimens for analysis of drugs for the purpose of therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in routine clinical setting. We describe the development and validation of a microanalytical technique for the determination of metformin from dried blood spots. The method is based on reversed phase high-performance liquid chromatography with ultraviolet detection. Drug recovery in the developed method was found to be more than 84%. The limits of detection and quantification were calculated to be to be 90 and 150 ng/ml, respectively. The intraday and interday precision (measured by CV%) was always less than 9%. The accuracy (measured by relative error, %) was always less than 12%. Stability analysis showed that metformin is stable for at least 2 months when stored at -70 degrees C. The small volume of blood required (10 mu L), combined with the simplicity of the analytical technique makes this a useful procedure for monitoring metformin concentrations in routine clinical settings. The method is currently being applied to the analysis of blood spots taken from diabetic patients to assess adherence to medications and relationship between metformin level and metabolic control of diabetes. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes the development of SPE and HPLC methods for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Several extraction and HPLC methods have been described previously for the determination of each of these analytes in plasma separately. The simultaneous determination of these analytes is important for the routine monitoring of diabetic patients who take combination medications and for studying the pharmacokinetics of the combined dosage forms. In addition this developed method can serve as a standard method for the plasma determination of these analytes therefore saving time, effort and money. The recoveries of the developed methods were found to be between 76.3% and 101.9%. The limits of quantification were between 5 and 22.5 ng/ml. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error %) was always less than 12%. Stability analysis showed that all analytes are stable for at least 3 months when stored at -70degreesC. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accelerated soil erosion is an aspect of dryland degradation that is affected by repeated intense drought events and land management activities such as commercial livestock grazing. A soil stability index (SSI) that detects the erosion status and susceptibility of a landscape at the pixel level, i.e., stable, erosional, or depositional pixels, was derived from the spectral properties of an archived time series (from 1972 to 1997) of Landsat satellite data of a commercial ranch in northeastern Utah. The SSI was retrospectively validated with contemporary field measures of soil organic matter and erosion status that was surveyed by US federal land management agencies. Catastrophe theory provided the conceptual framework for retrospective assessment of the impact of commercial grazing and soil water availability on the SSI. The overall SSI trend was from an eroding landscape in the early drier 1970s towards stable conditions in the wetter mid-1980s and late 1990s. The landscape catastrophically shifted towards an extreme eroding state that was coincident with the “The Great North American Drought of 1988”. Periods of landscape stability and trajectories toward stability were coincident with extremely wet El Niño events. Commercial grazing had less correlation with soil stability than drought conditions. However, the landscape became more susceptible to erosion events under multiple droughts and grazing. Land managers now have nearly a year warning of El Niño and La Niña events and can adjust their management decisions according to predicted landscape erosion conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An HPLC method has been developed and validated for the rapid determination of mercaptopurine and four of its metabolites; thioguanine, thiouric acid, thioxanthine and methylmercaptopurine in plasma and red blood cells. The method involves a simple treatment procedure based on deproteinisation by perchloric acid followed by acid hydrolysis and heating for 45 min at 100 degrees C. The developed method was linear over the concentration range studied with a correlation coefficient >0.994 for all compounds in both plasma and erythrocytes. The lower limits of quantification were 13, 14, 3, 2, 95 pmol/8 x 101 RBCs and 2, 5, 2, 3, 20 ng/ml plasma for thioguanine, thiouric acid, mercaptopurine, thioxanthine and methylmercaptopurine, respectively. The method described is selective and sensitive enough to analyse the different metabolites in a single run under isocratic conditions. Furthermore, it has been shown to be applicable for monitoring these metabolites in paediatric patients due to the low volume requirement (200 mu l of plasma or erythrocytes) and has been successfully applied for investigating population pharmacokinetics, pharmacogenetics and non-adherence to therapy in these patients. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This study presents a measurement-based method for the early detection of power system oscillations, with consideration of mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet-based support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in frequency bands, whereas the SVDD method is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude, or that are resonant, can be alarmed to the system operator, to reduce the risk of system instability. The proposed method is exemplified using measured data from a chosen wind farm site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The incorporation of melamine into food products is banned but its misuse has been widely reported in both animal feeds and food. The development of a rapid screening immunoassay for monitoring of the substance is an urgent requirement. Two haptens of melamine were synthesized by introducing spacer arms of different lengths and structures on the triazine ring of the analyte molecular structure. 6-Aminocaproic acid and 3-mercaptopropionic acid were reacted with 2-chloro-4,6-diamino-1,3,5-triazine (CAAT) to produce hapten 1[3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylamino) hexanoic acid] and hapten 2[3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylthio) propanoic acid]. respectively. The molecular structures of the two haptens were identified by I H nuclear magnetic resonance spectrometry, mass spectrometry and infrared spectrometry. An immunogen was prepared by coupling hapten 1 to bovine serum albumin (BSA). Two plate coating antigens were prepared by coupling both haptens to egg ovalbumin (OVA). A competitive indirect enzyme-linked immunosorbent assay (ciELISA) was developed to evaluate homogeneous and heterogeneous assay formats. The results showed that polyclonal antibodies with high titers were obtained, and the heterogeneous immunoassay format demonstrated a better performance with an IC50 of 70.6 ng mL(-1), a LOD of 2.6 ng mL(-1) and a LOQ of 7.6 ng mL(-1). Except for cyromazine, no obvious cross-reactivity to common compounds was found. The data showed that the hapten synthesis was successful and the resultant antisera could be used in an immunoassay for the rapid and sensitive detection of this banned chemical. (C) 2010 Elsevier B.V. All rights reserved.