974 resultados para speed reduction
Resumo:
As a part of the Managing Uncertainty in Complex Models (MUCM) project, research at Aston University will develop methods for dimensionality reduction of the input and/or output spaces of models, as seen within the emulator framework. Towards this end this report describes a framework for generating toy datasets, whose underlying structure is understood, to facilitate early investigations of dimensionality reduction methods and to gain a deeper understanding of the algorithms employed, both in terms of how effective they are for given types of models / situations, and also their speed in applications and how this scales with various factors. The framework, which allows the evaluation of both screening and projection approaches to dimensionality reduction, is described. We also describe the screening and projection methods currently under consideration and present some preliminary results. The aim of this draft of the report is to solicit feedback from the project team on the dataset generation framework, the methods we propose to use, and suggestions for extensions that should be considered.
Resumo:
We show experimentally and numerically that in high-speed strongly dispersion-managed standard fiber soliton systems nonlinear interactions limit the propagation distance. We present results that show that the effect of these interactions can be significantly reduced by appropriate location of the amplifier within the dispersion map. Using this technique, we have been able to extend the propagation distance of 10-Gbit/s 231–1pseudorandom binary sequence soliton data to 16, 500km over standard fiber by use of dispersion compensation. To our knowledge this distance is the farthest transmission over standard fiber without active control ever reported, and it was achieved with the amplifier placed after the dispersion-compensating fiber in a recirculating loop.
Resumo:
The research, which was given the terms of reference, "To cut the lead time for getting new products into volume production", was sponsored by a company which develops and manufactures telecommunications equipment. The research described was based on studies made of the development of two processors which were designed to control telephone exchanges in the public network. It was shown that for each of these products, which were large electronic systems containing both hardware and software, most of their lead time was taken up with development. About half of this time was consumed by activities associated with redesign resulting from changes found to be necessary after the original design had been built. Analysing the causes of design changes showed the most significant to be Design Faults. The reasons why these predominated were investigated by seeking the collective opinion from design staff and their management using a questionnaire. Using the results from these studies to build upon the works of other authors, a model of the development process of large hierarchical systems is derived. An important feature of this model is its representation of iterative loops due to design changes. In order to reduce the development time, two closely related philosophies are proposed: By spending more time at the early stages of development (detecting and remedying faults in the design) even greater savings can be made later on, The collective performance of the development organisation would be improved by increasing the amount and speed of feedback about that performance. A trial was performed to test these philosophies using readily available techniques for design verification. It showed that about an 11 per cent saving would be made on the development time and that the philosophies might be equally successfully applied to other products and techniques.
Resumo:
We report the performance of a group of adult dyslexics and matched controls in an array-matching task where two strings of either consonants or symbols are presented side by side and have to be judged to be the same or different. The arrays may differ either in the order or identity of two adjacent characters. This task does not require naming – which has been argued to be the cause of dyslexics’ difficulty in processing visual arrays – but, instead, has a strong serial component as demonstrated by the fact that, in both groups, Reaction times (RTs) increase monotonically with position of a mismatch. The dyslexics are clearly impaired in all conditions and performance in the identity conditions predicts performance across orthographic tasks even after age, performance IQ and phonology are partialled out. Moreover, the shapes of serial position curves are revealing of the underlying impairment. In the dyslexics, RTs increase with position at the same rate as in the controls (lines are parallel) ruling out reduced processing speed or difficulties in shifting attention. Instead, error rates show a catastrophic increase for positions which are either searched later or more subject to interference. These results are consistent with a reduction in the attentional capacity needed in a serial task to bind together identity and positional information. This capacity is best seen as a reduction in the number of spotlights into which attention can be split to process information at different locations rather than as a more generic reduction of resources which would also affect processing the details of single objects.
Resumo:
We show experimentally and numerically that in high-speed strongly dispersion-managed standard fiber soliton systems nonlinear interactions limit the propagation distance. We present results that show that the effect of these interactions can be significantly reduced by appropriate location of the amplifier within the dispersion map. Using this technique, we have been able to extend the propagation distance of 10-Gbit/s 231–1pseudorandom binary sequence soliton data to 16, 500km over standard fiber by use of dispersion compensation. To our knowledge this distance is the farthest transmission over standard fiber without active control ever reported, and it was achieved with the amplifier placed after the dispersion-compensating fiber in a recirculating loop.
Resumo:
Switched reluctance motors (SRMs) are gaining in popularity because of their robustness, low cost, and excellent high-speed characteristics. However, they are known to cause vibration and noise primarily due to the radial pulsating force resulting from their double-saliency structure. This paper investigates the effect of skewing the stator and/or rotor on the vibration reduction of the three-phase SRMs by developing four 12/8-pole SRMs, including a conventional SRM, a skewed rotor-SRM (SR-SRM), a skewed stator-SRM (SS-SRM), and a skewed stator and rotor-SRM (SSR-SRM). The radial force distributed on the stator yoke under different skewing angles is extensively studied by the finite-element method and experimental tests on the four prototypes. The inductance and torque characteristics of the four motors are also compared, and a control strategy by modulating the turn-ON and turn-OFF angles for the SR-SRM and the SS-SRM are also presented. Furthermore, experimental results validate the numerical models and the effectiveness of the skewing in reducing the motor vibration. Test results also suggest that skewing the stator is more effective than skewing the rotor in the SRMs.
Resumo:
Prior work of our research group, that quantified the alarming levels of radiation dose to patients with Crohn’s disease from medical imaging and the notable shift towards CT imaging making these patients an at risk group, provided context for this work. CT delivers some of the highest doses of ionising radiation in diagnostic radiology. Once a medical imaging examination is deemed justified, there is an onus on the imaging team to endeavour to produce diagnostic quality CT images at the lowest possible radiation dose to that patient. The fundamental limitation with conventional CT raw data reconstruction was the inherent coupling of administered radiation dose with observed image noise – the lower the radiation dose, the noisier the image. The renaissance, rediscovery and refinement of iterative reconstruction removes this limitation allowing either an improvement in image quality without increasing radiation dose or maintenance of image quality at a lower radiation dose compared with traditional image reconstruction. This thesis is fundamentally an exercise in optimisation in clinical CT practice with the objectives of assessment of iterative reconstruction as a method for improvement of image quality in CT, exploration of the associated potential for radiation dose reduction, and development of a new split dose CT protocol with the aim of achieving and validating diagnostic quality submillisiever t CT imaging in patients with Crohn’s disease. In this study, we investigated the interplay of user-selected parameters on radiation dose and image quality in phantoms and cadavers, comparing traditional filtered back projection (FBP) with iterative reconstruction algorithms. This resulted in the development of an optimised, refined and appropriate split dose protocol for CT of the abdomen and pelvis in clinical patients with Crohn’s disease allowing contemporaneous acquisition of both modified and conventional dose CT studies. This novel algorithm was then applied to 50 patients with a suspected acute complication of known Crohn’s disease and the raw data reconstructed with FBP, adaptive statistical iterative reconstruction (ASiR) and model based iterative reconstruction (MBIR). Conventional dose CT images with FBP reconstruction were used as the reference standard with which the modified dose CT images were compared in terms of radiation dose, diagnostic findings and image quality indices. As there are multiple possible user-selected strengths of ASiR available, these were compared in terms of image quality to determine the optimal strength for this modified dose CT protocol. Modified dose CT images with MBIR were also compared with contemporaneous abdominal radiograph, where performed, in terms of diagnostic yield and radiation dose. Finally, attenuation measurements in organs, tissues, etc. with each reconstruction algorithm were compared to assess for preservation of tissue characterisation capabilities. In the phantom and cadaveric models, both forms of iterative reconstruction examined (ASiR and MBIR) were superior to FBP across a wide variety of imaging protocols, with MBIR superior to ASiR in all areas other than reconstruction speed. We established that ASiR appears to work to a target percentage noise reduction whilst MBIR works to a target residual level of absolute noise in the image. Modified dose CT images reconstructed with both ASiR and MBIR were non-inferior to conventional dose CT with FBP in terms of diagnostic findings, despite reduced subjective and objective indices of image quality. Mean dose reductions of 72.9-73.5% were achieved with the modified dose protocol with a mean effective dose of 1.26mSv. MBIR was again demonstrated superior to ASiR in terms of image quality. The overall optimal ASiR strength for the modified dose protocol used in this work is ASiR 80%, as this provides the most favourable balance of peak subjective image quality indices with less objective image noise than the corresponding conventional dose CT images reconstructed with FBP. Despite guidelines to the contrary, abdominal radiographs are still often used in the initial imaging of patients with a suspected complication of Crohn’s disease. We confirmed the superiority of modified dose CT with MBIR over abdominal radiographs at comparable doses in detection of Crohn’s disease and non-Crohn’s disease related findings. Finally, we demonstrated (in phantoms, cadavers and in vivo) that attenuation values do not change significantly across reconstruction algorithms meaning preserved tissue characterisation capabilities with iterative reconstruction. Both adaptive statistical and model based iterative reconstruction algorithms represent feasible methods of facilitating acquisition diagnostic quality CT images of the abdomen and pelvis in patients with Crohn’s disease at markedly reduced radiation doses. Our modified dose CT protocol allows dose savings of up to 73.5% compared with conventional dose CT, meaning submillisievert imaging is possible in many of these patients.