964 resultados para solid-phase crystallization (SPC)
Resumo:
Superconductor mixed oxides were often used as catalysts at higher temperature in gas phase oxidations, and considered not suitable for lower temperature reactions in the liquid-solid phase; here the catalysis of YBa2Cu3O7+/-x and Y2BaCuO5+/-x in the phenol hydroxylation at lower temperature with H2O2 as oxygen donor was studied, and found that the superconductor YBa2Cu3O7+/-x, has no catalytic activity for phenol hydroxylation, but Y2BaCuO5+/-x does, even has better catalytic activity and stability than most previously reported ones. With the studies of catalysis of other simple metal oxides and perovskite-like mixed oxides, a radical substitution mechanism is proposed and the experimental facts are explained clearly, and draw a conclusion that the perovskite-like mixed oxides with (AO)(ABO(3)) and (AO)2(ABO(3)) structure have better catalytic activity than the simple perovskite oxides with (ABO(3))(3) structure alone, and (AO) structure unit is the key for the mixed oxides to have the phenol hydroxylation activity. No pollution of this process is very important for its further industrial application.
Resumo:
Superconductor mixed oxides are often used as catalysts at high temperature in gas-solid phase oxidations and considered not suitable for lower temperature reactions in the liquid-solid phase; here the catalysis of La2-xSrxCuO4+/-lambda (x = 0, 0.1, 0.7, 1) mixed oxides in phenol hydroxylation at lower temperatures are studied, and we find that the value of x has a significant effect on catalytic activity: the lower its value, the higher the catalytic activity; a mechanism is proposed to explain the experimental phenomena.
Resumo:
Influence of ester group size in polymethacrylates (PMAs) , including PMMA, PEMA and PBMA, on beta phase crystallization of poly(vinylidene fluoride) (PVF2) in highly oriented films of PVF2/PMAs=80/20 blends has been investigated by FTIR and TEM. The melt-drawn films of pure PVF2 consist of highly oriented lamellae, in which the alpha phase is predominant. Adding a given amount of PMAs (20 wt%) into PVF2 results in formation of fibrillar crystals and increase of relative amount of the beta phase. The influence extent is in order of PMMA > PEMA > PBMA, regarding the ester group size in the PMAs.
Resumo:
Polyvinylidene fluoride (PVF_2) exhibits at least four crystalline phases (α, β, γ, and δ). Among them, β phase is the most important one because it is directly related to the piezoand pyro-electric activities of PVF_2. In recent years, more attention has been paid to the β
Resumo:
Urinary 8-hydroxydeoxyguanosine (80HdG) has been considered as an excellent marker of individuals at high risk of developing cancer. Until now, urinary 80HdG has largely been measured by high-performance liquid chromatography with electrochemical detection. A new method for the analysis of urinary 80HdG by high-performance capillary electrophoresis has been developed and optimized in our laboratory. A single step solid-phase extraction procedure was optimized and used for extracting 80HdG from human urine. Separations were performed in an uncoated silica capillary (50 cm x 50 tm i.d.) using a P/ACE MDQ system with UV detection. The separation of 80HdG from interfering urinary matrix components is optimized with regard to pH, applied voltage, pressure injection time and concentration of SDS in running buffer. The detection limit of this method is 0.4 mug/ml, the linear range is 0.8-500 mug/ml, the correlation coefficients levels is better than 0.999. The developed method is simple, fast and good reproducibility, furthermore, it requires a very small injection volumes and low costs of analysis, which makes it possible to provide a new noninvasive assay for an indirect measurement of oxidative DNA damage.
Resumo:
A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 muL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized. (C) 2004 American Society for Mass Spectrometry.
Resumo:
SCOPUS: ar.j
Resumo:
Anti-neutrophil cytoplasmic antibodies (ANCA) are diagnostic markers for systemic vasculitis. They are classically I detected by an indirect immunofluorescence test using normal donor neutrophils as substrate. This assay lacks antigenic specificity and is not quantitative. The 'EC/BCR Project for ANCA Assay Standardization' is an international collaboration study with the aim to develop and standardize solid phase assays for ANCA detection. In this part of the study the isolation and characterization of proteinase-3 and myeloperoxidase, the two main target molecules for ANCA, and the development and standardization of ELISAs with these antigens are described. Six laboratories successfully isolated purified proteinase-3 preparations that could be used. Three of these preparations, together with one myeloperoxidase preparation, were subsequently used for ANCA testing by ELISA. The ELISA technique was standardized in two rounds of testing in the 14 participating laboratories. The coefficient of variation of these new assays decreased from values of approx. 50% in the first round to approx. 20% in the second round. We conclude that purified proteinase-3 and myeloperoxidase can be used in standardized ELISAs for ANCA detection. Whether such procedures offer advantages over the IIF test will be determined in a prospective clinical study.
Resumo:
An integrated fire spread model is presented in this study including several sub-models representing different phenomena of gaseous and solid combustion. The integrated model comprises of the following sub-models: a gaseous combustion model, a thermal radiation model that includes the effects of soot, and a pyrolysis model for charring combustible solids. The interaction of the gaseous and solid phases are linked together through the boundary conditions of the governing equations for the flow domain and the solid region respectively. The integrated model is used to simulate a fire spread experiment conducted in a half-scale test compartment. Good qualitative and reasonable quantitative agreement is achieved between the experiment and numerical predictions.
Resumo:
Gas-solids two phase systems are widely employed within process plant in the form of pneumatic conveyors, dust extraction systems and solid fuel injection systems. The measurement of solids phase velocity therefore has wide potential application in flow monitoring and, in conjunction with density measurement instrumentation, solids mass flow rate measurement. Historically, a number of authors have detailed possible measurement techniques, and some have published limited test results. It is, however, apparent that none of these technologies have found wide application in industry. Solids phase velocity measurements were undertaken using real time cross correlation of signals from two electrostatic sensors spaced axially along a pipeline conveying pulverised coal (PF). Details of the measurement equipment, the pilot scale test rig and the test results are presented.