584 resultados para soft contact lens
Resumo:
Purpose: The aim of this study was to investigate the extent and pattern of use of grading scales for contact lens complications (‘grading scales’) in optometric practice. Methods: An anonymous postal survey was sent to all 756 members of the Queensland Division of Optometrists Association Australia. Information was elicited relating to level of experience, practice type and location, and mode of usage of grading scales. Results: Survey forms were returned by 237 optometrists, representing a 31 per cent response rate. The majority of respondents (61 per cent) reported using grading scales frequently in practice, while 65 per cent of these preferred to use the Efron Grading Scales for Contact Lens Complications. Seventy-six per cent of optometrists use a method of incremental grading rather than simply grading with whole numbers. Grading scales are more likely to be used by optometrists who have recently graduated (p < 0.001), have a postgraduate certificate in ocular therapeutics (p = 0.018), see more contact lens patients (p = 0.027) and use other forms of grading scales (p < 0.001). The most frequently graded ocular conditions were corneal staining, papillary conjunctivitis and conjunctival redness. The main reasons for not using grading scales included a preference for sketches, photographs or descriptions (87 per cent) and unavailability of scales (29 per cent). Conclusion: Grading scales for contact lens complications are used extensively in optometric practice for a variety of purposes. This tool can now be considered as an expected norm in contact lens practice. We advocate the incorporation of such grading scales into professional guidelines and standards for good optometric clinical practice.
Resumo:
PURPOSE: To examine the relationship between contact lens (CL) case contamination and various potential predictive factors. METHODS: 74 subjects were fitted with lotrafilcon B (CIBA Vision) CLs on a daily wear basis for 1 month. Subjects were randomly assigned one of two polyhexamethylene biguanide (PHMB) preserved disinfecting solutions with the corresponding regular lens case. Clinical evaluations were conducted at lens delivery and after 1 month, when cases were collected for microbial culture. A CL care non-compliance score was determined through administration of a questionnaire and the volume of solution used was calculated for each subject. Data was examined using backward stepwise binary logistic regression. RESULTS: 68% of cases were contaminated. 35% were moderately or heavily contaminated and 36% contained gram-negative bacteria. Case contamination was significantly associated with subjective dryness symptoms (OR 4.22, CI 1.37–13.01) (P<0.05). There was no association between contamination and subject age, ethnicity, gender, average wearing time, amount of solution used, non-compliance score, CL power and subjective redness (P>0.05). The effect of lens care system on case contamination approached significance (P=0.07). Failure to rinse the case with disinfecting solution following CL insertion (OR 2.51, CI 0.52–12.09) and not air drying the case (OR 2.31, CI 0.39–13.35) were positively correlated with contamination; however, did not reach statistical significance. CONCLUSIONS: Our results suggest that case contamination may influence subjective comfort. It is difficult to predict the development of case contamination from a variety of clinical factors. The efficacy of CL solutions, bacterial resistance to disinfection and biofilm formation are likely to play a role. Further evaluation of these factors will improve our understanding of the development of case contamination and its clinical impact.
Resumo:
Purpose. To devise and validate artist-rendered grading scales for contact lens complications Methods. Each of eight tissue complications of contact lens wear (listed under 'Results') was painted by a skilled ophthalmic artist (Terry R. Tarrant) in five grades of severity: 0 (normal), 1 (trace), 2 (mild), 3 (moderate) and 4 (severe). A representative slit lamp photograph of a tissue response of each of the eight complications was shown to 404 contact lens practitioners who had never before used clinical grading scales. The practitioners were asked to grade each tissue response to the nearest 0.1 grade unit by interpolation. Results. The standard deviation (± s.d.) of the 404 responses for each tissue complication is tabulated below:_ing_ 0.5 Endothelial pplymegethisjij-4 0.7 Epithelial microcysts 0.5 Endothelial blebs_ 0.4 Stromal edema_onjunctiva! hyperemia 0.4 Stromal neovascularization 0.4 Papillary conjunctivitis 0.5 The frequency distributions and best-fit normal curves were also plotted. The precision of grading (s.d. x 2) ranged from 0.8 to 1.4, with a mean precision of 1.0. Conclusions. Grading scales afford contact lens practitioners with a method of quantifying the severity of adverse tissue responses to contact lens wear. It is noteworthy that the statistically verified precision of grading (1.0 scale unit) concurs precisely with the essential design feature of the grading scales that each grading step of 1.0 corresponds to clinically significant difference in severity. Thus, as a general rule, a difference or change in grade of > 1.0 can be taken to be both clinically and statistically significant when using these grading scales. Trained observers are likely to achieve even greater grading precision. Supported by Hydron Limited.
Resumo:
Objective: To establish risk factors for moderate and severe microbial keratitis among daily contact lens (CL) wearers in Australia. Design: A prospective, 12-month, population-based, case-control study. Participants: New cases of moderate and severe microbial keratitis in daily wear CL users presenting in Australia over a 12-month period were identified through surveillance of all ophthalmic practitioners. Case detection was augmented by record audits at major ophthalmic centers. Controls were users of daily wear CLs in the community identified using a national telephone survey. Testing: Cases and controls were interviewed by telephone to determine subject demographics and CL wear history. Multiple binary logistic regression was used to determine independent risk factors and univariate population attributable risk percentage (PAR%) was estimated for each risk factor.; Main Outcome Measures: Independent risk factors, relative risk (with 95% confidence intervals [CIs]), and PAR%. Results: There were 90 eligible moderate and severe cases related to daily wear of CLs reported during the study period. We identified 1090 community controls using daily wear CLs. Independent risk factors for moderate and severe keratitis while adjusting for age, gender, and lens material type included poor storage case hygiene 6.4× (95% CI, 1.9-21.8; PAR, 49%), infrequent storage case replacement 5.4× (95% CI, 1.5-18.9; PAR, 27%), solution type 7.2× (95% CI, 2.3-22.5; PAR, 35%), occasional overnight lens use (<1 night per week) 6.5× (95% CI, 1.3-31.7; PAR, 23%), high socioeconomic status 4.1× (95% CI, 1.2-14.4; PAR, 31%), and smoking 3.7× (95% CI, 1.1-12.8; PAR, 31%). Conclusions: Moderate and severe microbial keratitis associated with daily use of CLs was independently associated with factors likely to cause contamination of CL storage cases (frequency of storage case replacement, hygiene, and solution type). Other factors included occasional overnight use of CLs, smoking, and socioeconomic class. Disease load may be considerably reduced by attention to modifiable risk factors related to CL storage case practice.
Resumo:
Moderator Opening The early focus of contact lens wear and ocular health was on oxygen delivery. However, as we learn more about how the eye works, and investigate how the contact lens interacts with the cornea, the role of the tear film has risen in prominence. A healthy tear film is critical for normal ocular homeostasis, and abnormalities of the tear film are the primary cause of dry eye. In order to improve patient eye health and comfort during lens wear, we need to further elucidate the relationship among contact lenses, contact lens solutions, the tear film, and the corneal epithelium, and find ways to maintain homeostasis of the ocular surface. In this section, we review the latest data and opinions on this complex relationship between contact lenses and lens care solutions
Resumo:
Eye care practitioners (ECPs) would tend to agree that wearing contact lenses increases the risk for infection, but millions of patients are still fitted with lenses every year because ECPs feel that the risk is manageable and that their patients' eye health can be protected. The Fusarium and Acanthamoeba keratitis outbreaks of years past were a wake-up call to manufacturers, ECPs, and regulatory agencies that risk cannot be managed without diligence, and that the complex relationship between contact lens materials, contact lens solutions, and compliance needs to be better understood in order to optimize the efficacy of contact lens care and improve care guidelines.
Resumo:
The report of this subcommittee concerns the impact of contact lenses (CLs) on the ocular surface, with a particular emphasis on CL discomfort (CLD). We define the ocular surface, its regional anatomy, and the physiological responses of each region to CL wear.
Resumo:
In this, the 10th anniversary of the introduction of silicone hydrogel contact lenses onto the market, it is perhaps timely to attempt to reconcile the apparently disparate results from different authors in relation to the incidence of keratitis with silicone hydrogel lenses and indeed, with contact lenses in general. In attempting to understand the findings of these various studies, we propose that consideration be given to the competing effects of an improved physiological response due to increased corneal oxygenation with these lenses versus their mechanical impact...