998 resultados para semen analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sperm cryopreservation success depends upon the maintenance of spermatozoa fertility potential. Sperm cells must preserve both integrity and functionality of several cell structures. The stabilization phase must allow the exit of water from the sperm cells via osmosis. This study aimed to compare the effect of refrigeration in the commercial refrigerator (CR) and the transport/refrigeration box (TRB) upon the viability of frozen bull sperm diluted in three different extenders (A, B and C). Ten Nellore bulls, Bos taurus indicus maintained in Artificial Insemination Center were used and the spermatozoa samples was assessed for Plasma Membrane Integrity and CASA evaluation. The stabilization phase (5 degrees C/4 hours) was performed in the CR as well as in the TRB, and then samples were exposed to nitrogen vapor during 20 minutes and then plunged into nitrogen. The statistical analysis was done using the variance analysis and the significance level was set at 5%. In the CR the post-thawing parameters for PM and ALH were higher (p < 0.05) in the extender A (glicine egg-yolk) and extender B (glicine egg-free) when compared with extender C (TRIS egg-yolk). As for BCF, STR and LIN, the parameters were higher (p < 0.05) in extender B than in C. Samples that were stabilized in the TRB presented higher post-thawing parameters (p < 0.05) for PM and LIN in extender A and extender B when compared with C. BCF and STR parameters were higher (p < 0.05) in extemder B when compared with C. Extender B samples had higher (p < 0.05) PMI when stabilized in CR. The findings in this experiment enable us to say that both CR and TRB were effective in keeping the viability of post-thawing bull semen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simulation model implemented in the programming software Delphi XE® was applied to evaluate sex selection in bovine. The hypothesis under investigation was that a dynamic model with stochastic and deterministic elements could detect the sexed semen technique to minimize pregnancy cost and to determine the adequate number of recipients required for in vivo (ET) and in vitro embryo production (IVP) in the proposed scenarios. Sex selection was compared through semen sexed using flow cytometry (C1) and density gradient centrifugation techniques (C2) in ET and IVP. Sensibility analyses were used to identify the adequate number of recipients for each scenario. This number was reinserted into the model to determine the biological and financial values that maximized ET and IVP using sexed semen (C1M and C2M). New scenarios showed that the density gradient technique minimized pregnancy cost based on the proposed scenarios. In addition, the adequate number of recipients (ET - C1M - 115 and C2M - 105)/(IVP - C1M - 145 and C2M - 140) per donor used was determined to minimize the pregnancy cost in all scenarios.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eight reproductive boars were divided into three groups and inoculated with Toxoplasma gondii [GI (n=3) 1.5×104 oocysts strain P; GII (n=3) 1.0×106 tachyzoites strain RH; and GIII (n=2) non-inoculated control]. Clinical, hematological, parasitemia and serological tests and studies of the parasite in the semen through bioassay and PCR, and in reproductive organs (Bioassay and immunohistochemical analyses) were conducted to evaluate the toxoplasmic infection. Blood and semen were collected on day -2, -1, 1, 3, 5, 7, 9, 11, 14 and weekly up to 84 days post-inoculation (DPI). No clinical or hematimetric alteration was observed in the boars. Parasitemia was detected in one boar inoculated with oocysts at the 7th DPI and in another boar infected with tachyzoites (GII) at the 3rd and 49 th DPI. Serological tests revealed antibodies against T. gondii in animals inoculated with oocysts or tachyzoites at the 7th DPI with dilutions of 1:256 and 1:64, which reached peaks of 1:4096 at day 11 and 9, respectively. The bioassays revealed the presence of the parasite in semen samples of a boar inoculated with oocysts (GI) at 3, 49 and 56 DPI and from two boars infected with tachyzoites (GII), one animal at 5 and two animals at 49 days DPI. Mice inoculated with semen from the control group (GIII) remained serologically negative. PCR analysis showed T. gondii DNA in the semen of Boar 1 and Boar 3 inoculated with tachyzoites and oocysts, respectively. The immunohistochemical tests showed T. gondii in the reproductive organs of Boar 1 and Boar 2, inoculated with tachyzoites and oocysts, respectively. These findings suggest the possible occurrence of venereal transmission of T. gondii in swine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of the damage caused by the sperm preservation process is crucial to improving fertilization rates. The objective of this study was to evaluate the effects of refrigeration temperature (5°C and 15°C) and storage time (0, 12, 24, 48, and 72 hours) on apoptotic markers in equine semen. Membrane phosphatidylserine translocation index, caspase activation index, and DNA fragmentation index were analyzed using epifluorescence microscopy. Analysis of variance was used for statistical analysis, and Tukey test was used to compare means. The significance level was set at P < .05. The results demonstrated that for transport duration shorter than 24 hours, semen quality was maintained when stored at either 5°C or 15°C. A storage temperature of 5°C should be used when it is necessary to transport semen for longer than 24 hours. There was a significant decrease in semen quality after 48 hours of refrigeration. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, different freezing systems (Styrofoam box and Mini Digitcool ZH 400) and storage volumes (0.5- and 0.25-mL straws) were compared with regard to sperm kinetics and plasma membrane integrity of frozen and thawed semen. For that, three ejaculates from four animals were frozen in Styrofoam box and Mini Digitcool ZH 400 machine. The 0.5-mL straws were thawed at 46°C for 20 seconds, and the 0.25-mL straws were thawed at 46°C for 12 seconds. Statistical analysis was performed using program R of descriptive analysis box plot, followed by analysis of variance using PROC MIXED of SAS 9.1 package. Variances of 5% were considered as different. There was no interaction between the straw sizes and volumes; however, statistical differences were observed between the semen storage volumes. The 0.5-mL straws had higher total motility (%), progressive motility (%), average path velocity (μm/s), straight-line velocity (μm/s), curvilinear velocity (μm/s), and rapid sperm percentage (%) than the 0.25-mL straws. However, plasma membrane integrity analysis did not differ between the two straws. Thus, it is possible to conclude that equine sperm cryopreserved in 0.5-mL straws has better sperm kinetics than when stored in 0.25-mL straws. Additionally, it is possible to conclude that automated systems that enable faster freezing rates result in a seminal quality that is similar to the one obtained by the conventional system using Styrofoam boxes. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)