993 resultados para right-angle prism


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the enhancement of sensitivity of variable incidence angle LSPR biosensor by monitoring biomolecular interactions of biotin-streptavidin with gold thin film. The investigation is carried out by means of introducing an additional layer of graphene sheet on top of gold layer (graphene biosensor) and using different coupling configuration of laser beam. The sensitivity, which is indicated by the shift of plasmon resonance angle, increases with graphene deposited onto the gold layers and is linearly related with the number of graphene layers. In addition, an investigation of the shift of plasmon dip is carried out for two different analyte interfaces: air and water. It is found that graphene biosensor has better sensitivity for triangular prism, higher prism angle, and water interface. The evaluation approach involves a plot of a reflectivity curve as a function of the angle of incidence while the operating wavelength is kept fixed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights.Methods: Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography.Results: In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values.Conclusion: Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a measurement of the fraction f(+) of right-handed W bosons produced in top quark decays, based on a candidate sample of t (t) over bar events in the lepton+jets decay mode. These data correspond to an integrated luminosity of 230 pb(-1), collected by the D0 detector at the Fermilab Tevatron p (p) over bar Collider at root s=1.96 TeV. We use a constrained fit to reconstruct the kinematics of the t (t) over bar and decay products, which allows for the measurement of the leptonic decay angle theta(*) for each event. By comparing the cos theta(*) distribution from the data with those for the expected background and signal for various values of f(+), we find f(+)=0.00 +/- 0.13(stat)+/- 0.07(syst). This measurement is consistent with the standard model prediction of f(+)=3.6 x 10(-4).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider, in the electroweak standard model context, several left-right asymmetries in μe elastic scattering at fixed target and collider experiments. For the former case, we show that the muon mass effects are important in a wide energy range. We also show that these asymmetries are sensitive to the electroweak mixing angle θW. The effect of an extra Z' neutral vector boson appearing in a 3-3-1 model is also considered. The capabilities of these asymmetries in the search of this extra Z' are addressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Epidermoid cysts of the cerebellopontine angle (CPA) can be a surgical challenge for the pediatric neurosurgeon. Ideally, total removal must be achieved; however, occasional adhesions of these tumors to vital neurovascular structures and extension far beyond the midline may preclude their total removal. The aims of this article are to present an alternative surgical approach to these lesions and to provide the rationale for this technique. Material and methods A 16-year-old boy was admitted to our pediatric neurosurgery department with a 1-year history of nonspecific headaches. His neurological examination showed right-sided dysmetria and gait ataxia. Magnetic resonance scans showed a space-occupying lesion on the right CPA with low intensity on T-1-weighted images and high intensity on T-2-weighted images. Results Craniotomy for tumor excision via pre- and subtemporal transtentorial approach was performed disclosing a 3.5 x 3 x 2.8-cm(3) well-encapsulated tumor, which was confirmed to be an epidermoid cyst. The postoperative course was uneventful. Conclusions A combined pre- and subtemporal approach utilizes a wide opening of the tentorium and the option of supratentorial retraction of the cerebellum to provide an excellent angle of approach to CPA lesions involving the anterolateral aspect of the brain stem in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Dyslexia is the most common developmental reading disorder that affects language skills. Latent strabismus (heterophoria) has been suspected to be causally involved. Even though phoria correction in dyslexic children is commonly applied, the evidence in support of a benefit is poor. In order to provide experimental evidence on this issue, we simulated phoria in healthy readers by modifying the vergence tone required to maintain binocular alignment. METHODS Vergence tone was altered with prisms that were placed in front of one eye in 16 healthy subjects to induce exophoria, esophoria, or vertical phoria. Subjects were to read one paragraph for each condition, from which reading speed was determined. Text comprehension was tested with a forced multiple choice test. Eye movements were recorded during reading and subsequently analyzed for saccadic amplitudes, saccades per 10 letters, percentage of regressive (backward) saccades, average fixation duration, first fixation duration on a word, and gaze duration. RESULTS Acute change of horizontal and vertical vergence tone does neither significantly affect reading performance nor reading associated eye movements. CONCLUSION Prisms in healthy subjects fail to induce a significant change of reading performance. This finding is not compatible with a role of phoria in dyslexia. Our results contrast the proposal for correcting small angle heterophorias in dyslexic children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid crystal devices are being used in many non-display applications in order to construct small devices controlled by low voltage electronics without mechanical components. In this work, we present a novel liquid crystal device for laser beam steering. In this device the orientation of the liquid crystal molecules can be controlled. A change in the liquid crystal orientation results in a change of the refractive index. When a laser beam passes through the device, the beam will be deviated (Fig.1) and the device works a prism. The main difference between this device and a prism is that in the device the orientation profile of the liquid crystal molecules can be modified so that the laser beam can be deviated a required angle: the device is tuneable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: A análise de Bolton, análise que quantifica o tamanho dentário, é uma referência importante para profissionais que buscam finalizações ortodônticas adequadas. Objetivo: O objetivo deste trabalho é verificar se há discrepância entre os indivíduos com oclusão normal natural e maloclusões de Classe I e de Classe II divisão 1 de Angle pertencentes a amostra selecionada, em relação aos valores encontrados por Bolton, bem como verificar também se há dimorfismo sexual. Metodologia: 3 grupos contendo 35 pares e modelos em gesso cada, separados pelo tipo de oclusão, pertencentes ao acervo do programa de pós-graduação em Ortodontia da Universidade Metodista de São Paulo foram medidos com paquímetro digital em sua maior distância mésiodistal desde 1º molar direito a 1º molar esquerdo, dos arcos superiores e inferiores, com dentição permanente. Os valores foram tabulados e a proporção de Bolton foi aplicada. Resultados: Respectivamente para os grupos 1, 2 e 3, a proporção total encontrada foi de 90,36 (DP±1,70), 91,17 (DP±2,58) e 90,76 (DP±2,45), e a proporção anterior foi de 77,73 (DP±2,39), 78,01 (DP±2,66) e 77,30 (DP±2,65). Conclusão: não houve dimorfismo sexual nem diferença estatisticamente significante comparando os valores aos sugeridos por Bolton.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To assess systemic and ocular vascular reactivity in response to warm and cold provocation in untreated patients with primary open-angle glaucoma and normal control subjects. METHODS. Twenty-four patients with primary open-angle glaucoma and 22 normal control subjects were subjected to a modified cold pressor test involving immersion of the right hand in 40°C warm water followed by 4°C cold water exposure, and finger and ocular blood flow were assessed by means of peripheral laser Doppler flowmetry and retinal flowmetry, respectively. Finger and body temperature as well as intraocular pressure, systemic blood pressure, systemic pulse pressure, heart rate, and ocular perfusion pressure were also monitored. RESULTS. The patients with glaucoma demonstrated an increase in diastolic blood pressure (P = 0.023), heart rate (P = 0.010), and mean ocular perfusion pressure (P = 0.039) during immersion of the tested hand in 40°C water. During cold provocation, the patients demonstrated a significant decrease in finger (P = 0.0003) and ocular blood flow (the parameter velocity measured at the temporal neuroretinal rim area; P = 0.021). Normal subjects did not demonstrate any blood flow or finger temperature changes during immersion of the tested hand in 40°C water (P > 0.05); however, they exhibited increases in systolic blood pressure (P = 0.034) and pulse pressure (P = 0.0009) and a decrease in finger blood flow (P = 0.0001) during cold provocation. In normal subjects, the ocular blood flow was unchanged during high- and low-temperature challenge. CONCLUSIONS. Cold provocation elicits a different blood pressure, and ocular blood flow response in patients with primary open-angle glaucoma compared with control subjects. These findings suggest a systemic autonomic failure and ocular vascular dysregulation in POAG patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To determine the visual outcome following initiation of brimonidine therapy in glaucoma. Methods: 16 newly diagnosed previously untreated glaucoma patients were randomly assigned to either timalal 0.5% or brimanidine 0.2%. Visual acuity, contrast sensitivity (CS), visual fields, intraocular pressure (IOP), blaad pressure, and heart rate were evaluated at baseline and after 3 months. Results: IOP reduction was similar far both groups (p<0.05). Brimanidine improved CS; in the right eye at 6 and 12 cpd (p = 0.043, p = 0.017); in the left eye at 3 and 12 cpd (p = 0.044, p = 0.046). Timolol reduced CS at 18 cpd in the right eye (p = 0.041). There was no change in any other measured parameters. Conclusion: Glaucoma patients exhibit improved CS an initiation of brimanidine therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The principal theme of this thesis is the effect of yoked prisms on body posture and egocentric perception. Yoked prisms have been clinically used in the management of a variety of visual and neuro-motor dysfunctions. Most studies have been conducted in pathological populations by studying the effects of prismatic adaptation, without distinguishing short and long term effects. In this study, postural and perceptual prismatic effects have been studied by preventing prism adaptation. A healthy population was selected in order to investigate the immediate prismatic effects, when there is no obvious benefit from their use for the individual. Posturography was used to assess changes in weight distribution and shifts in centre of pressure (barycentre). In addition, photographic analyses were used to assess effects on posture on the x and z axis. Experiments with space board and visual midline shift were used for the evaluation of spatial perception and egocentric localisation. One pair of 8 Δ yoked prisms base left (BL) and one pair of 8 Δ yoked prisms base up (BU) were applied randomly and compared to a pair of plano lenses. Results suggest that immediate prismatic effects take place on a perceptual level and are reflected on an altered body posture respectively without significant changes in weight distribution. Yoked prisms BL showed a rightward rotational effect on spatial perception by expanding space on the z axis when viewing through the base of the prism and constricting space through the apex of the prism. Body posture responded respectively to what was visually perceived by altering posture. A rightward shift and tilt of the head was recorded along with the hips shift and shoulders tilt in the dame direction. Additionally, right shoulder shifted backwards and an angular midline shift to the right was recorded. The egocentric localisation was affected by shifting the midline perception to the left. Yoked prisms BU resulted on a head shift forward and a reduction of the head-neck angle by bringing the chin closer to the chest. The egocentric localisation was altered on the vertical axis providing subjects the perception that their eye level was higher during the experiment. In conclusion, yoked prisms seemed to induce changes in body posture, mainly in the upper body and head, without any significant changes in weight distribution. These changes are partially reflected in spatial perception tests and egocentric localisation before any prismatic adaptation takes place.