988 resultados para right pulmonary artery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of physical preconditioning in the responsiveness of rat pulmonary rings submitted to lung ischemia/reperfusion (IR). Wistar rats were divided into three groups: Sedentary sham-operated (SD/SHAM); sedentary submitted to ischemia/reperfusion (SD/IR) and trained submitted to ischemia/reperfusion (TR/IR) animals. Exercise training consisted in sessions of 60 min/day running sessions, 5 days/week for 8 weeks. Left pulmonary IR was performed by occluding for 90 min and reperfusing for 120 min. After that, pulmonary arteries were isolated and concentration-response curves to acetylcholine (ACh), histamine (HIST), sodium nitroprusside (SNP), phenylephrine and U46619 were obtained. Neither potency (- log EC50) nor maximal responses (Emax) were modified for ACh and HIST in all groups. On the other hand, the potency for SNP was significantly increased in TR/IR group (8.23 ± 0.06) compared to SD/IR group (7.85 ± 0.04). Contractile responses mediated by a-adrenergic receptor were markedly decreased in IR groups (SD/IR: 6.75 ± 0.06 and TR/IR: 6.62 ± 0.04) compared to SD/SHAM (7.33 ± 0.05). No changes were seen for the U46619 in all groups. In conclusion, the present study shows that exercise training has no protective actions in the local blood vessel where the IR process takes place. © 2006 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary artery sarcomas (PAS) are rare and probably incurable tumours. The clinical manifestations are non-specific and very similar to that of patients with thromboembolic disease, resulting in delay of the correct diagnosis and proper treatment. We report the case of a 66-year-old woman with PAS diagnosed by computed tomography guided biopsy. Chemotherapy treatment was initiated but the patient died 11 months after diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical evidence has identified the pulmonary circulation as an important target of air pollution. It was previously demonstrated that in vitro exposure to fine particulate matter (aerodynamic diameter <= 2.5 mu m, PM2.5) induces endothelial dysfunction in isolated pulmonary arteries. We aimed to investigate the effects of in vivo exposure to urban concentrated PM2.5 on rat pulmonary artery reactivity and the mechanisms involved. For this, adult Wistar rats were exposed to 2 weeks of concentrated Sao Paulo city air PM2.5 at an accumulated daily dose of approximately 600 mu g/m(3). Pulmonary arteries isolated from PM2.5-exposed animals exhibited impaired endothelium-dependent relaxation to acetylcholine without significant changes in nitric oxide donor response compared to control rats. PM2.5 caused vascular oxidative stress and enhanced protein expression of Cu/Zn- and Mn-superoxide dismutase in the pulmonary artery. Protein expression of endothelial nitric oxide synthase (eNOS) was reduced, while tumor necrosis factor (TNF)-alpha was enhanced by PM2.5 inhalation in pulmonary artery. There was a significant positive correlation between eNOS expression and maximal relaxation response (E-max) to acetylcholine. A negative correlation was found between vascular TNF-alpha expression and E-max to acetylcholine. Plasma cytokine levels, blood cells count and coagulation parameters were similar between control and PM2.5-exposed rats. The present findings showed that in vivo daily exposure to concentrated urban PM2.5 could decrease endothelium-dependent relaxation and eNOS expression on pulmonary arteries associated with local high TNF-alpha level but not systemic pro-inflammatory factors. Taken together, the present results elucidate the mechanisms underlying the trigger of cardiopulmonary diseases induced by urban ambient levels of PM2.5. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aberrant origin of a pulmonary artery from the ascending aorta is an uncommon congenital vascular malformation with poor survival without surgery. In this case report, we describe the unusual late diagnosis of this congenital malformation in an otherwise asymptomatic young man presenting with mild hemoptysis. We review the natural and modified history of this defect and the relevant aspects of follow-up in adult life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Right axillary artery (RAA) cannulation is increasingly used in cardiac surgery. Little is known about resulting flow patterns in the aorta. Therefore, flow was visualized and analyzed. A mock circulatory circuit was assembled based on a compliant transparent anatomical silicon aortic model. A RAA cannula was connected to a continuous flow rotary blood pump (RBP), pulsatile heart action was provided by a pneumatic ventricular assist device (PVAD). Peripheral vascular resistance, regional flow and vascular compliance were adjusted to obtain physiological flow and pressure waveforms. Colorants were injected automatically for flow visualization. Five flow distributions with a total flow of 4 l/min were tested (%PVAD:%RBP): 100:0, 75:25, 50:50, 25:75, 0:100. Colorant distribution was assessed using quantitative 2D image processing. Continuous flow from the RAA divided in a retrograde and an antegrade portion. Retro- to antegrade flow ratio increased with increasing RAA-flow. At full RBP support flow was stagnant in the ascending aorta. There were distinct flow patterns between the right- and left-sided supra-aortic branches. At full RBP support retrograde flow was demonstrated in the right carotid and right vertebral arteries. Further studies are needed to confirm and evaluate the described flow patterns.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infarct size (IS) increases with vascular occlusion time, area at risk for infarction, lack of collateral supply, absence of preconditioning, and myocardial demand for O2 supply. ECG S-T segment elevation is used as a measure of severity of ischemia and a surrogate for IS. This study in 50 patients with coronary artery disease undergoing a first 120-s balloon occlusion of a stenosis sought to determine whether S-T segment elevation, corrected for the above-mentioned variables, in the left coronary artery (LCA group, n = 36) is different from that in the right coronary artery (RCA group, n = 14) territory. After consideration of all known determinants of IS, particularly mass at risk and collateral supply, the LCA territory is more sensitive than the RCA region to a 2-min period of myocardial ischemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determining whether hypoplasia of a coronary artery has caused or contributed to death is often complicated by an absence of histologic evidence of myocardial ischemia in the area of the heart supplied by the affected artery and also by the lack of data for assessing coronary artery size at autopsy. A 45-year-old woman is reported who collapsed and died and who was found at autopsy to have a dominant, small-caliber, right coronary artery, with acute and chronic ischemic changes in the posterior interventricular septum supplied by the diminutive vessel. This case provides evidence that small-caliber coronary arteries may be associated with a lethal outcome. Given the difficulties that may occur in determining whether there is a causal link between small coronary artery caliber and death, it is possible that this may be an underdiagnosed cause of sudden cardiac death, rather than a coincidental finding of minimal significance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Implantation of stents into the bronchial walls is a newly developed method to treat lung emphysema, which is now being tested clinically. During this procedure, a bronchoscope carrying a Doppler ultrasonography head is placed into a segmental bronchus and the blood vessels running in parallel to the bronchus are localized. Once a safe location without blood vessels is found, the bronchial wall is perforated and a stent is placed within the wall to improve the expiratory volume of these "bypasses" to the adjacent lung parenchyma. We observed a fatal complication with this method in a 60-year-old man. The bronchial wall and the pulmonary artery were perforated by one of the stents inducing massive bleeding, which could not be stopped. The patient died due to aspiration of blood in combination with massive loss of blood. The general risk to perforate the pulmonary artery during this procedure cannot be estimated from this single observation but should be considered regarding the legal and clinical aspects.