161 resultados para retrofit
Resumo:
Summary of Actions Towards Sustainable Outcomes Environmental Issues / Principal Impacts The increased growth of cities is intensifying its impact on people and the environment through: • increased use of energy for the heating and cooling of more buildings, leading to urban heat islands and more greenhouse gas emissions • increased amount of hard surfaces contributing to higher temperatures in cities and more stormwater runoff • degraded air quality and noise impact • reduced urban biodiversity • compromised health and general well-being of people Basic Strategies In many design situations boundaries and constraints limit the application of cutting EDGe actions. In these circumstances designers should at least consider the following: • Consider green roofs early in the design process in consultation with all stakeholders to enable maximised integration with building systems and to mitigate building cost (avoid constructing as a retrofit). • Design of the green roof as part of a building’s structural, mechanical and hydraulic systems could lead to structural efficiency, the ability to optimise cooling benefits and better integrated water recycling systems. • Inform the selection of the type of green roof by considering its function, for example designing for social activity, required maintenance/access regime, recycling of water or habitat regeneration or a combination of uses. • Evaluate existing surroundings to determine possible links to the natural environment and choice of vegetation for the green roof with availability of local plant supply and expertise. Cutting EDGe Strategies • Create green roofs to contribute positively to the environment through reduced urban heat island effect and building temperatures, to improved stormwater quality, increased natural habitats, provision of social spaces and opportunity for increased local food supply. • Maximise solar panel efficiency by incorporating with design of green roof. • Integrate multiple functions for a single green roof such as grey water recycling, food production, more bio-diverse plantings, air quality improvement and provision of delightful spaces for social interaction. Synergies & references • BEDP Environment Design Guide DES 53: Roof and Facade Gardens GEN 4: Positive Development – designing for Net Positive Impacts TEC 26: Living Walls - a way to green the built environment • Green Roofs Australia: www.greenroofs.wordpress.com • International Green Roof Association: www.igra-world.com • Green Roofs for Healthy Cities (USA): www.greenroofs.org • Centre for Urban Greenery and Ecology (Singapore): http://research.cuge.com.sg
Resumo:
Human activity-induced vibrations in slender structural sys tems become apparent in many different excitation modes and consequent action effects that cause discomfort to occupants, crowd panic and damage to public infrastructure. Resulting loss of public confidence in safety of structures, economic losses, cost of retrofit and repairs can be significant. Advanced computational and visualisation techniques enable engineers and architects to evolve bold and innovative structural forms, very often without precedence. New composite and hybrid materials that are making their presence in structural systems lack historical evidence of satisfactory performance over anticipated design life. These structural systems are susceptible to multi-modal and coupled excitation that are very complex and have inadequate design guidance in the present codes and good practice guides. Many incidents of amplified resonant response have been reported in buildings, footbridges, stadia a nd other crowded structures with adverse consequences. As a result, attenuation of human-induced vibration of innovative and slender structural systems very ofte n requires special studies during the design process. Dynamic activities possess variable characteristics and thereby induce complex responses in structures that are sensitive to parametric variations. Rigorous analytical techniques are available for investigation of such complex actions and responses to produce acceptable performance in structural systems. This paper presents an overview and a critique of existing code provisions for human-induced vibration followed by studies on the performance of three contrasting structural systems that exhibit complex vibration. The dynamic responses of these systems under human-induced vibrations have been carried out using experimentally validated computer simulation techniques. The outcomes of these studies will have engineering applications for safe and sustainable structures and a basis for developing design guidance.
Resumo:
Green building is building that the focus is to maximize the energy efficiency and resources used. While, retrofitting is the process of renovate or refurnish the existing building. Therefore by retrofit existing buildings that comply with green building requirement, it improves the environmental attributes of the buildings. In Malaysia, existing buildings and its communities contribute over 40% of green house gases to the environment. This paper describes a study that explores the potential to retrofit existing campus buildings that response to sustainable green building standard. A validation survey was carried out and the data collected was analysed using SPSS in order to confirm the significance of retrofitting Universiti Teknologi Malaysia (UTM) buildings toward green building initiative. The results show that all the twenty eight identified green elements recorded average index of higher than 3.5 which means that there is significant needs to retrofit the existing buildings to green buildings. This study concludes that it is urgently need for the campus to response to green building requirements in order to achieve higher energy effeciency and this can be done through effective etrofitting of existing buildings.
Resumo:
This paper reports outcomes of a pilot study to develop a conceptual framework to allow people to retrofit a building-layer to gain better control of their own built- environments. The study was initiated by the realisation that discussions surrounding the improvement of building performances tend to be about top-down technological solutions rather than to help and encourage bottom-up involvement of building-users. While users are the ultimate beneficiaries and their feedback is always appreciated, their direct involvements in managing buildings would often be regarded as obstruction or distraction. This is largely because casual interventions by uninformed building-users tend to disrupt the system. Some earlier researches showed however that direct and active participation of users could improve the building performance if appropriate training and/or systems were introduced. We also speculate this in long run would also make the built environment more sustainable. With this in mind, we looked for opportunities to retrofit our own office with an interactive layer to study how we could introduce ad-hoc systems for building-users. The aim of this paper is to describe our vision and initial attempts followed by discussion.
Resumo:
Powerlink Queensland has undertaken an aggressive program of research, development and implementation of IEC 61850-based system solutions. The intent is to move towards an IEC 61850 process bus using a two-step approach.
Resumo:
Climate change is leading to an increased frequency and severity of heat waves. Spells of several consecutive days of unusually high temperatures have led to increased mortality rates for the more vulnerable in the community. The problem is compounded by the escalating energy costs and increasing peak electrical demand as people become more reliant on air conditioning. Domestic air conditioning is the primary determinant of peak power demand which has been a major driver of higher electricity costs. This report presents the findings of multidisciplinary research which develops a national framework to evaluate the potential impacts of heat waves. It presents a technical, social and economic approach to adapt Australian residential buildings to ameliorate the impact of heat waves in the community and reduce the risk of its adverse outcomes. Through the development of a methodology for estimating the impact of global warming on key weather parameters in 2030 and 2050, it is possible to re-evaluate the size and anticipated energy consumption of air conditioners in future years for various climate zones in Australia. Over the coming decades it is likely that mainland Australia will require more cooling than heating. While in some parts the total electricity usage for heating and cooling may remain unchanged, there is an overall significant increase in peak electricity demand, likely to further drive electricity prices. Through monitoring groups of households in South Australia, New South Wales and Queensland, the impact of heat waves on both thermal comfort sensation and energy consumption for air conditioning has been evaluated. The results show that households are likely to be able to tolerate slightly increased temperature levels indoors during periods of high outside temperatures. The research identified that household electricity costs are likely to rise above what is currently projected due to the impact of climate change. Through a number of regulatory changes to both household design and air conditioners, this impact can be minimised. A number of proposed retrofit and design measures are provided, which can readily reduce electricity usage for cooling at minimal cost to the household. Using a number of social research instruments, it is evident that households are willing to change behaviour rather than to spend money. Those on lower income and elderly individuals are the least able to afford the use of air conditioning and should be a priority for interventions and assistance. Increasing community awareness of cost effective strategies to manage comfort and health during heat waves is a high priority recommended action. Overall, the research showed that a combined approach including behaviour change, dwelling modification and improved air conditioner selection can readily adapt Australian households to the impact of heat waves, reducing the risk of heat related deaths and household energy costs.
Resumo:
This paper describes an investigation into the effectiveness of using spray-on nano-particle reinforced polymer and aluminium foam as new types of retrofit material to prevent the breaching and collapse of unreinforced concrete masonry walls subjected to blast over a whole range of dynamic and impulsive regimes. Material models from the LSDYNA material library were used to model the behaviors of each of the materials and its interface for retrofitted and unretrofitted masonry walls. Available test data were used to validate the numerical models. Using the validated LS-DYNA numerical models, the pressure-impulse diagrams for retrofitted concrete masonry walls were constructed. The efficiency of using these retrofits to strengthen the unreinforced concrete masonry unit (CMU) walls under various pressures and impulses was investigated using pressure-impulse diagrams. Comparisons were made to find the most efficient retrofits for masonry walls against blasts.
Resumo:
Advanced composite materials offer remarkable potential in the upgrade of civil engineering structures. The evolution of CFRP (carbon fibre reinforced polymer) technologies and their versatility for applications in civil constructions require comprehensive and reliable codes of practice. Guidelines are available on the rehabilitation and retrofit of concrete structures with advanced composite materials. However, there is a need to develop appropriate design guidelines for CFRP strengthened steel structures. It is important to understand the bond characteristics between CFRP and steel plates. This paper describes a series of double strap shear tests loaded in tension to investigate the bond between CFRP sheets and steel plates. Both normal modulus (240 GPa) and high modulus (640 GPa) CFRPs were used in the test program. Strain gauges were mounted to capture the strain distribution along the CFRP length. Different failure modes were observed for joints with normal modulus CFRP and those with high modulus CFRP. The strain distribution along the CFRP length is similar for the two cases. A shorter effective bond length was obtained for joints with high modulus CFRP whereas larger ultimate load carrying capacity can be achieved for joints with normal modulus CFRP when the bond length is long enough.
Resumo:
A significant reduction in global greenhouse gas (GHG) emissions is a priority, and the preservation of existing building stock presents a significant opportunity to reduce the carbon footprint of our built environment. Within this ‘wicked’ problem context, and moving beyond the ad hoc and incremental performance improvements that have been made to date, collaborative and multidisciplinary efforts are required to find rapid and transformational solutions. Design has emerged as a strategic and redirective practice, and lessons can therefore be learned about transformation and potentially applied in the built environment. The purpose of this paper is to discuss a pragmatic and novel research approach for undertaking such applied design driven research. This paper begins with a discussion of key contributions from design science (rational) and action research (reflective) philosophies in creating an emerging methodological ‘hybrid design approach’. This research approach is then discussed in relation to its application to specific research exploring the processes, methods and lessons from design in heritage building retrofit projects. Drawing on both industry and academic knowledge to ensure relevance and rigour, it is anticipated that the hybrid design approach will be useful for others tackling such complex wicked problems that require context-specific solutions.
Resumo:
Integrated design and delivery solutions (IDDS) is a priority theme of the International Council for Research and Innovation in Building and Construction (CIB), which will be used to drive the global research agenda forward. IDDS will use collaborative work processes and enhanced skills together with integrated data, information and knowledge management to minimize structural and process inefficiencies and to enhance the value delivered during design, build, operation, and across projects. IDDS build on building information modelling (BIM), incorporating advances in the training and employment of people, together with supporting new technologies. The successful use of IDDS involves changes in each of the project phases from conceptual planning and business case formulation to all stages of the supply chain: design, construction, commissioning, operation, retrofit and decommissioning. For each of these phases, key changes in the structure and culture of the project team across the different collaborating firms create a favourable context for IDDS. Special for IDDS thinking is the idea of adding project and whole-life value in all phases, for all stakeholders...
Resumo:
CIB is developing a priority theme, now termed Improving Construction and Use through Integrated Design & Delivery Solutions (IDDS). The IDDS working group for this theme adopted the following definition: Integrated Design and Delivery Solutions use collaborative work processes and enhanced skills, with integrated data, information, and knowledge management to minimize structural and process inefficiencies and to enhance the value delivered during design, build, and operation, and across projects. The design, construction, and commissioning sectors have been repeatedly analysed as inefficient and may or may not be quite as bad as portrayed; however, there is unquestionably significant scope for IDDS to improve the delivery of value to clients, stakeholders (including occupants), and society in general, simultaneously driving down cost and time to deliver operational constructed facilities. Although various initiatives developed from computer‐aided design and manufacturing technologies, lean construction, modularization, prefabrication and integrated project delivery are currently being adopted by some sectors and specialisations in construction; IDDS provides the vision for a more holistic future transformation. Successful use of IDDS requires improvements in work processes, technology, and people’s capabilities to span the entire construction lifecycle from conception through design, construction, commissioning, operation, refurbishment/ retrofit and recycling, and considering the building’s interaction with its environment. This vision extends beyond new buildings to encompass modifications and upgrades, particularly those aimed at improved local and area sustainability goals. IDDS will facilitate greater flexibility of design options, work packaging strategies and collaboration with suppliers and trades, which will be essential to meet evolving sustainability targets. As knowledge capture and reuse become prevalent, IDDS best practice should become the norm, rather than the exception.
Resumo:
Post-earthquake fire (PEF) is considered one of the most high risk and complicated problems affecting buildings in urban areas and can cause even more damage than the earthquake itself. However, most standards and codes ignore the implications of PEF and so buildings are not normally designed with PEF in mind. What is needed is for PEF factors to be routinely scrutinized and codified as part of the design process. A systematic application is presented as a means of mitigating the risk of PEF in urban buildings. This covers both existing buildings, in terms of retrofit solutions, and those yet to be designed, where a PEF factor is proposed. To ensure the mitigation strategy meets the defined criteria, a minimum time is defined – the safety guaranteed time target – where the safety of the inhabitants in a building is guaranteed.
Resumo:
The results of the pilot demonstrated that a pharmacist delivered vaccinations services is feasible in community pharmacy and is safe and effective. The accessibility of the pharmacist across the influenza season provided the opportunity for more people to be vaccinated, particularly those who had never received an influenza vaccine before. Patient satisfaction was extremely high with nearly all patients happy to recommend the service and to return again next year. Factors critical to the success of the service were: 1. Appropriate facilities 2. Competent pharmacists 3. Practice and decision support tools 4. In-‐store implementation support We demonstrated in the pilot that vaccination recipients preferred a private consultation area. As the level of privacy afforded to the patients increased (private room vs. booth), so did the numbers of patients vaccinated. We would therefore recommend that the minimum standard of a private consultation room or closed-‐in booth, with adequate space for multiple chairs and a work / consultation table be considered for provision of any vaccination services. The booth or consultation room should be used exclusively for delivering patient services and should not contain other general office equipment, nor be used as storage for stock. The pilot also demonstrated that a pharmacist-‐specific training program produced competent and confident vaccinators and that this program can be used to retrofit the profession with these skills. As vaccination is within the scope of pharmacist practice as defined by the Pharmacy Board of Australia, there is potential for the universities to train their undergraduates with this skill and provide a pharmacist vaccination workforce in the near future. It is therefore essential to explore appropriate changes to the legislation to facilitate pharmacists’ practice in this area. Given the level of pharmacology and medicines knowledge of pharmacists, combined with their new competency of providing vaccinations through administering injections, it is reasonable to explore additional vaccines that pharmacists could administer in the community setting. At the time of writing, QPIP has already expanded into Phase 2, to explore pharmacists vaccinating for whooping cough and measles. Looking at the international experience of pharmacist delivered vaccination, we would recommend considering expansion to other vaccinations in the future including travel vaccinations, HPV and selected vaccinations to those under the age of 18 years. Overall the results of the QPIP implementation have demonstrated that an appropriately trained pharmacist can deliver safely and effectively influenza vaccinations to adult patients in the community. The QPIP showed the value that the accessibility of pharmacists brings to public health outcomes through improved access to vaccinations and the ability to increase immunisation rates in the general population. Over time with the expansion of pharmacist vaccination services this will help to achieve more effective herd immunity for some of the many diseases which currently have suboptimal immunisation rates.
Resumo:
Cool roof coatings have a beneficial impact on reducing the heat load of a range of building types, resulting in reduced cooling energy loads. This study seeks to understand the extent to which cool roof coatings could be used as a residential demand side management (DSM) strategy for retrofitting existing housing in a constrained network area in tropical Australia where peak electrical demand is heavily influenced by residential cooling loads. In particular this study seeks to determine whether simulation software used for building regulation purposes can provide networks with the ‘impact certainty’ required by their DSM principles. The building simulation method is supported by a field experiment. Both numerical and experimental data confirm reductions in total consumption (kWh) and energy demand (kW). The nature of the regulated simulation software, combined with the diverse nature of residential buildings and their patterns of occupancy, however, mean that simulated results cannot be extrapolated to quantify benefits to a broader distribution network. The study suggests that building data gained from regulatory simulations could be a useful guide for potential impacts of widespread application of cool roof coatings in this region. The practical realization of these positive impacts, however, would require changes to the current business model for the evaluation of DSM strategies. The study provides seven key recommendations that encourage distribution networks to think beyond their infrastructure boundaries, recognising that the broader energy system also includes buildings, appliances and people.
Resumo:
Retrofit activities, such as improving hydrology and incorporating more advanced treatment methods into systems where feasible, may improve phosphorus (P) removal performance of current Best Management Practices (BMPs). In the recent past, chemical treatment systems such as chemical dosing and the use of adsorptive media have become more prevalent for treating stormwater and hold promise for improving the P removal performance of stormwater treatment BMPs (Bachand et al., 2005; Patel et al., 2005). Our primary objective for this project has been to investigate whether adsorptive media hold any promise for improving P removal performance of stormwater basins and treatment wetlands at Lake Tahoe.... (PDF contains 99 pages)