965 resultados para recording
Resumo:
Fe:BiOx films are fabricated on K9 glass substrates by rf-magnetron sputtering of a BiFeO target under argon atmosphere with increasing sputtering power from 80 to 200 W at room temperature. It is found that the thin films grown at the sputtering power of 160W can be formed at an appropriate deposition rate and have an improved surface morphology. The XPS result reveals that the films investigated are comprised of Bi, Fe and O elements. A typical XRD pattern shows that no phase transition occurs in the films up to 400 degrees C. The results of the blue laser recording test demonstrate that the Fe:BiOx films have good writing sensitivity for blue laser beam (406.7 nm) and good stability after reading 10000 times. The recording marks of 200nm or less are obtained. These results indicate that the introduction of Fe into BiOx films can reduce the mark size and improve the stability of the films.
Resumo:
Three kinds of rare earth complexes derived from dibenzoylmethane (DBM) ligand were synthesized by reacting free ligand and different rare earth ions(La (3+), Sm3+ and Gd3+). Their contents and structures were postulated based on elemental analysis, LDI-TOF-MS, FT-IR spectra and UV-Vis spectra. Smooth films on K9 glass substrates were prepared using the spin-coating method. Their solubility in organic solvents, absorption and reflection properties of thin film and thermal stability of these complexes were evaluated. These complexes would be a promising recording material for high-density digital versatile disc-recordable (HD-DVD-R) system. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
We describe the application of two types of stereo camera systems in fisheries research, including the design, calibration, analysis techniques, and precision of the data obtained with these systems. The first is a stereo video system deployed by using a quick-responding winch with a live feed to provide species- and size- composition data adequate to produce acoustically based biomass estimates of rockfish. This system was tested on the eastern Bering Sea slope where rockfish were measured. Rockfish sizes were similar to those sampled with a bottom trawl and the relative error in multiple measurements of the same rockfish in multiple still-frame images was small. Measurement errors of up to 5.5% were found on a calibration target of known size. The second system consisted of a pair of still-image digital cameras mounted inside a midwater trawl. Processing of the stereo images allowed fish length, fish orientation in relation to the camera platform, and relative distance of the fish to the trawl netting to be determined. The video system was useful for surveying fish in Alaska, but it could also be used broadly in other situations where it is difficult to obtain species-composition or size-composition information. Likewise, the still-image system could be used for fisheries research to obtain data on size, position, and orientation of fish.
Resumo:
Introduction Hypoxia-ischemia (HI) is a major perinatal problem that results in severe damage to the brain impairing the normal development of the auditory system. The purpose of the present study is to study the effect of perinatal asphyxia on the auditory pathway by recording auditory brain responses in a novel animal experimentation model in newborn piglets. Method Hypoxia-ischemia was induced to 1.3 day-old piglets by clamping 30 minutes both carotid arteries by vascular occluders and lowering the fraction of inspired oxygen. We compared the Auditory Brain Responses (ABRs) of newborn piglets exposed to acute hypoxia/ischemia (n = 6) and a control group with no such exposure (n = 10). ABRs were recorded for both ears before the start of the experiment (baseline), after 30 minutes of HI injury, and every 30 minutes during 6 h after the HI injury. Results Auditory brain responses were altered during the hypoxic-ischemic insult but recovered 30-60 minutes later. Hypoxia/ischemia seemed to induce auditory functional damage by increasing I-V latencies and decreasing wave I, III and V amplitudes, although differences were not significant. Conclusion The described experimental model of hypoxia-ischemia in newborn piglets may be useful for studying the effect of perinatal asphyxia on the impairment of the auditory pathway.
Resumo:
EXTRACT (SEE PDF FOR FULL ABSTRACT): High-resolution proxy records of climate, such as varves, ice cores, and tree-rings, provide the opportunity for reconstructing climate on a year-by-year basis. In order to do so it is necessary to approximate the complex nonlinear response function of the natural recording system using linear statistical models. Three problems with this approach were discussed, and possible solutions were suggested. Examples were given from a reconstruction of Santa Barbara precipitation based on tree-ring records from Santa Barbara County.
Resumo:
The goal of this work is to examine the properties of recording mechanisms which are common to continuously recording high-resolution natural systems in which climatic signals are imprinted and preserved as proxy records. These systems produce seasonal structures as an indirect response to climatic variability over the annual cycle. We compare the proxy records from four different high-resolution systems: the Quelccaya ice cap of the Peruvian Andes; composite tree ring growth from southern California and the southwestern United States; and the marine varve sedimentation systems in the Santa Barbara basin (off California, United States) and in the Gulf of California, Mexico. An important focus of this work is to indicate how the interannual climatic signal is recorded in a variety of different natural systems with vastly different recording mechanisms and widely separated in space. These high-resolution records are the products of natural processes which should be comparable, to some degree, to human-engineered systems developed to transmit and record physical quantities. We therefore present a simple analogy of a data recording system as a heuristic model to provide some unifying concepts with which we may better understand the formation of the records. This analogy assumes special significance when we consider that natural proxy records are the principal means to extend our knowledge of climatic variability into the past, beyond the limits of instrumentally recorded data.
Resumo:
Simultaneous recording from multiple single neurones presents many technical difficulties. However, obtaining such data has many advantages, which make it highly worthwhile to overcome the technical problems. This report describes methods which we have developed to permit recordings in awake behaving monkeys using the 'Eckhorn' 16 electrode microdrive. Structural magnetic resonance images are collected to guide electrode placement. Head fixation is achieved using a specially designed headpiece, modified for the multiple electrode approach, and access to the cortex is provided via a novel recording chamber. Growth of scar tissue over the exposed dura mater is reduced using an anti-mitotic compound. Control of the microdrive is achieved by a computerised system which permits several experimenters to move different electrodes simultaneously, considerably reducing the load on an individual operator. Neurones are identified as pyramidal tract neurones by antidromic stimulation through chronically implanted electrodes; stimulus control is integrated into the computerised system. Finally, analysis of multiple single unit recordings requires accurate methods to correct for non-stationarity in unit firing. A novel technique for such correction is discussed.
Resumo:
An electrode drive is described for recordings of neurons in freely moving and chaired monkeys during the performance of behavioural tasks. The electrode drives are implanted for periods of up to 6 months, and can advance up to 42 electrodes using 14 independent drive mechanisms. The drive samples 288 points within a 12 mm x 12 min region, with 15 min of electrode travel. Major advantages are that recordings are made in freely moving monkeys, and these recordings can be compared with those in chaired experiments; waveforms of single neurons are stable, enabling prolonged recordings of the same neurons across periods of days; recordings can be made throughout the brain, including the dorsolateral prefrontal cortex and hippocampus; the drive accommodates both sharp microelectrodes and fine wire assemblies such as tetrodes. (C) 2003 Elsevier Science B.V; All rights reserved.
Resumo:
Activities of the project included: preparation of awareness materials on data reporting; organizing stakeholder awareness programmes; setting and maintaining an electronic database; inputs from participants and recommendations