932 resultados para reactor operation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Agitation rate is an important parameter in the operation of Anaerobic Sequencing Biofilm Batch Reactors (ASBBRs), and a proper agitation rate guarantees good mixing, improves mass transfer, and enhances the solubility of the particulate organic matter. Dairy effluents have a high amount of particulate organic matter, and their anaerobic digestion presents inhibitory intermediates (e. g., long-chain fatty acids). The importance of studying agitation in such batch systems is clear. The present study aimed to evaluate how agitation frequency influences the anaerobic treatment of dairy effluents. The ASBBR was fed with wastewater from milk pasteurisation process and cheese manufacture with no whey segregation. The organic matter concentration, measured as chemical oxygen demand (COD), was maintained at approximately 8,000 mg/L. The reactor was operated with four agitation frequencies: 500 rpm, 350 rpm, 200 rpm, and no agitation. In terms of COD removal efficiency, similar results were observed for 500 rpm and 350 rpm (around 90%) and for 200 rpm and no agitation (around 80%). Increasing the system`s agitation thus not only improved the global efficiency of organic matter removal but also influenced volatile acid production and consumption and clearly modified this balance in each experimental condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production of xylooligosaccharides (XOS) using a packed-bed enzymatic reactor was studied at lab-scale. For this, a xylanase from Aspergillus versicolor was immobilized on different supports. The optimal derivative was xylanase immobilized on glyoxyl-agarose supports. This derivative preserved 85% of its catalytic activity; it was around 700-fold more stable than the soluble enzyme after incubation at 60. °C and was able to be reused for at least 10 1. h-cycles retaining full catalytic activity. About 18% of oligosaccharides with prebiotic interest (X2-X6) were produced by the glyoxyl derivative in batch hydrolysis. The production of xylobiose was 2.5-fold higher using the immobilized preparation than with soluble enzyme and small concentrations of xylose (<0.1%) were observed only at the end of the reaction. The derivative was employed on a packed bed reactor, and the continuous operation with no recirculation reached 56% and 70% of the end of reaction with flow rates of 60. mL/h and 12. mL/h, respectively. In continuous operation with recirculation at a flow rate of 60. mL/h, the reaction was completed after four hours. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The resistive-type superconducting fault current limiters (RSFCL) prototypes using YBCO-coated conductors have shown current limitation for medium voltage class applications for acting time up to 80 ms. By connecting an air-core reactor in parallel with the RSFCL, thus making an hybrid current limiter, one can extend the acting time for up to 1 s. In this work, we report the performance of a hybrid current limiter subjected to an AC peak fault current of 2 kA during 1 s for which within the first 80 ms the SFCL limits the current concurrently with the air-core reactor, and for the remaining 920 ms, only the air-core reactor limits the current. In order to evaluate the actual conditions for subsequent reconnection of RSFCL to the power grid, the hybrid fault current limiter was tested varying the time interval for recovery from 900 ms and 1.2 s, followed again by the concurrent operation of the hybrid limiter during 1 s (SFCL during 80 ms). From this evaluation test, the recovery time can be measured and compared using the voltage peak generated in superconducting module from the first and second fault test. The recovery time was also determined through the pulsed current method (PCM) on short-length sample test. The results showed that the fault current was limited from 1.9 kA down to 514 A after 1 cycle of 60 Hz frequency, with recovery time lower than 1.2 s for two subsequent fault current tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work studies the optimization and control of a styrene polymerization reactor. The proposed strategy deals with the case where, because of market conditions and equipment deterioration, the optimal operating point of the continuous reactor is modified significantly along the operation time and the control system has to search for this optimum point, besides keeping the reactor system stable at any possible point. The approach considered here consists of three layers: the Real Time Optimization (RTO), the Model Predictive Control (MPC) and a Target Calculation (TC) that coordinates the communication between the two other layers and guarantees the stability of the whole structure. The proposed algorithm is simulated with the phenomenological model of a styrene polymerization reactor, which has been widely used as a benchmark for process control. The complete optimization structure for the styrene process including disturbances rejection is developed. The simulation results show the robustness of the proposed strategy and the capability to deal with disturbances while the economic objective is optimized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work studies the optimization and control of a styrene polymerization reactor. The proposed strategy deals with the case where, because of market conditions and equipment deterioration, the optimal operating point of the continuous reactor is modified significantly along the operation time and the control system has to search for this optimum point, besides keeping the reactor system stable at any possible point. The approach considered here consists of three layers: the Real Time Optimization (RTO), the Model Predictive Control (MPC) and a Target Calculation (TC) that coordinates the communication between the two other layers and guarantees the stability of the whole structure. The proposed algorithm is simulated with the phenomenological model of a styrene polymerization reactor, which has been widely used as a benchmark for process control. The complete optimization structure for the styrene process including disturbances rejection is developed. The simulation results show the robustness of the proposed strategy and the capability to deal with disturbances while the economic objective is optimized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe and analyze the efficiency of a new solar-thermochemical reactor concept, which employs a moving packed bed of reactive particles produce of H2 or CO from solar energy and H2O or CO2. The packed bed reactor incorporates several features essential to achieving high efficiency: spatial separation of pressures, temperature, and reaction products in the reactor; solid–solid sensible heat recovery between reaction steps; continuous on-sun operation; and direct solar illumination of the working material. Our efficiency analysis includes material thermodynamics and a detailed accounting of energy losses, and demonstrates that vacuum pumping, made possible by the innovative pressure separation approach in our reactor, has a decisive efficiency advantage over inert gas sweeping. We show that in a fully developed system, using CeO2 as a reactive material, the conversion efficiency of solar energy into H2 and CO at the design point can exceed 30%. The reactor operational flexibility makes it suitable for a wide range of operating conditions, allowing for high efficiency on an annual average basis. The mixture of H2 and CO, known as synthesis gas, is not only usable as a fuel but is also a universal starting point for the production of synthetic fuels compatible with the existing energy infrastructure. This would make it possible to replace petroleum derivatives used in transportation in the U.S., by using less than 0.7% of the U.S. land area, a roughly two orders of magnitude improvement over mature biofuel approaches. In addition, the packed bed reactor design is flexible and can be adapted to new, better performing reactive materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe and analyze the efficiency of a new solar-thermochemical reactor concept, which employs a moving packed bed of reactive particles produce of H-2 or CO from solar energy and H2O or CO2. The packed bed reactor incorporates several features essential to achieving high efficiency: spatial separation of pressures, temperature, and reaction products in the reactor; solid-solid sensible heat recovery between reaction steps; continuous on-sun operation; and direct solar illumination of the working material. Our efficiency analysis includes material thermodynamics and a detailed accounting of energy losses, and demonstrates that vacuum pumping, made possible by the innovative pressure separation approach in our reactor, has a decisive efficiency advantage over inert gas sweeping. We show that in a fully developed system, using CeO2 as a reactive material, the conversion efficiency of solar energy into H-2 and CO at the design point can exceed 30%. The reactor operational flexibility makes it suitable for a wide range of operating conditions, allowing for high efficiency on an annual average basis. The mixture of H-2 and CO, known as synthesis gas, is not only usable as a fuel but is also a universal starting point for the production of synthetic fuels compatible with the existing energy infrastructure. This would make it possible to replace petroleum derivatives used in transportation in the U. S., by using less than 0.7% of the U. S. land area, a roughly two orders of magnitude improvement over mature biofuel approaches. In addition, the packed bed reactor design is flexible and can be adapted to new, better performing reactive materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within the frame of the HiPER reactor, we propose and study a Self Cooled Lead Lithium blanket with two different cooling arrangements of the system First Wall – Blanket for the HiPER reactor: Integrated First Wall Blanket and Separated First Wall Blanket. We compare the two arrangements in terms of power cycle efficiency, operation flexibility in out-off-normal situations and proper cooling and acceptable corrosion. The Separated First Wall Blanket arrangement is superior in all of them, and it is selected as the advantageous proposal for the HiPER reactor blanket. However, it still has to be improved from the standpoint of proper cooling and corrosion rates

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En este trabajo se llevó a cabo el tratamiento de vinazas mediante dos tecnologías anaerobias. Se dividió en cuatro estudios técnicos. El primero fue el arranque y estabilización del reactor UASB (Upflow Anaerobic Sludge Blanket), en dónde se evaluó la estabilización mediante la eficiencia de remoción de DQO y la granulación del lodo. El segundo estudio evaluó el rendimiento del reactor UASB frente a diferentes Cva. El tercer estudio evaluó el efecto del TRH sobre la eficiencia del reactor UASB, y el cuarto de ellos fue evaluar el rendimiento del RABF (Reactor Anaerobio de Biomasa Fija). El reactor UASB de 2,6 L de capacidad, fue arrancado por lotes, con seis ensayos utilizando vinaza como sustrato. Se obtuvieron eficiencias de remoción en DQO en un rango de 79-91%, en los seis lotes. Se obtuvo formación de gránulos con diámetro (Ø) de 0,85-1,15 mm y un coeficiente de esfericidad (Є) de 0,7-0,77. Se logró la granulación de lodos tras 2 meses de operación. Alcanzada la estabilización del reactor UASB, se siguió una operación en flujo continuo. Las Cva probadas de 1, 2, 4 y 6 gDQO/L.d para el reactor UASB dan una respuesta bastante favorable con respecto al rendimiento del reactor, ya que presento eficiencias de remoción de DQOs del 51 hasta el 76%, eficiencias similares a los reportados por la literatura. En el estudio de TRH se operó con Cva de 6 gDQO/L.d y los TRH fueron de 24, 12 ,5 ,3 y 1 día. El % de eliminación de DQO fue de 51, 60, 57, 60 y 63 % remoción en DQOsoluble, respectivamente. Se alcanzó una producción de biogás máximo de 5.283 ml/d, pero al reducir el TRH se observó una reducción proporcional del volumen total de biogás. El %CH4 contenido en el biogás aumento al disminuir el TRH, reflejando valores de 80 al 92 % de CH4. El RABF con un volumen de 8,2 L, utilizo tubos de plástico corrugado como medio de soporte para las bacterias. Se aplicaron las siguientes Cva; 0,5, 1, 3 y 6 gDQO/L.d. El reactor RABF presento una excelente remoción de la materia orgánica (80% DQOs), una producción de biogás estable, y un contenido en CH4 del biogás muy interesante. Sin embargo, para una Cva superior a 3 gDQO/L.d empezó un comportamiento inesperado de reducción de capacidad. Las condiciones hidrodinámicas del reactor UASB son decisivas para la formación de los gránulos, condición previa para iniciar el flujo continuo. Al operar el reactor UASB en modo continuo, se pudo evaluar las mejores condiciones de operación para este tipo de residuo (vinaza). La Cva de 6 gDQO/L.d para el reactor UASB alimentado con vinaza bruta representa el límite de su capacidad. Sin embargo, al aumentar la Cva se genera una mayor producción de biogás y metano. La eficiencia de remoción de la DQO soluble es independiente del TRH, para una Cva de 6 g DQO/L•d y las condiciones de TRH probadas (24, 12, 5, 3 y 1 días). Los valores de remoción de DQO alcanzados son un poco superior a los valores de biodegradabilidad anaerobia de la vinaza observados de 50 %. De manera general, la reducción del TRH o bien la dilución de la vinaza no presenta un efecto significativo sobre la remoción de la materia orgánica soluble, pero si lo presenta en la remoción de sulfatos reduciendo indirectamente su toxicidad. El soporte termoplástico inoculado en el RABF y alimentado con vinaza bruta, actuó como un filtro, además de obtener buenos resultados en eliminación de DQO, pero dada las dimensiones y la altura del relleno se frena la evacuación del metano. This work was carried out by treatment vinasses with two anaerobic technologies. It was divided into four technical studies. The first was the start up and stabilization Upflow Anaerobic Sludge Blanket (UASB) reactor, where the stability was evaluated by the removal efficiency of COD and sludge granulation. The second study evaluated the performance of the UASB reactor against different OLR. The third study evaluated the effect of HRT on the efficiency of the UASB reactor, and the fourth of which was evaluate the performance Fixed Biomass Anaerobic (FBA) reactor. The UASB reactor of 2,6 L capacity, was started in batch, with six assays using vinasse as substrate. Were obtained removal efficiencies of COD in the range of 79- 91% in the six batches. Forming granules were obtained with a diameter (Ø) of 0,85- 1,15 mm and sphericity coefficient (Є) of 0,7 to 0,77. Sludge granulation was achieved after 2 months of operation. Once stabilization is achieved of the UASB reactor, it was followed by a continuous flow operation. The OLR tested 1, 2, 4 and 6 gCOD/L.d for UASB reactor gives a very favorable response regarding the performance of the reactor, as presented COD5 removal efficiencies of 51 to 76%, similar efficiencies those reported in the literature The HRT study was operated with an OLR of 6 gCOD/L.d and HRT were 24, 12, 5, 3 and 1 day. The removal efficiency was 51, 60, 57, 60 and 63% in soluble COD, respectively. It reached a maximum biogas production of 5.283 ml / d, but by reducing the HRT showed a proportional reduction in the total volume of biogas. The %CH4 content in the biogas increased with decreasing TRH, reflecting values of 80 to 92% of CH4. The FBA reactor with a volume of 8,2 L, used corrugated plastic tubes as carrier for bacteria transportation. The following OLR was applied, 0,5, 1, 3 and 6 gCOD/L.d. The FBA reactor showed an excellent removal of organic matter (80% CODS), a stable biogas production, and CH4 content very interesting. However, for more than 3 gCOD/L.d OLR began with unexpected behavior of capacity reduction. The UASB reactor hydrodynamic conditions are decisive for the formation of the granules, precondition to start the continuous flow. By operating the UASB reactor in continuous mode, it was possible to evaluate the best operating conditions for this type of waste (vinasse). The OLR of 6 gCOD/L.d for the UASB reactor fed with raw vinasse represents the limit of its capacity. However, with increasing OLR creates increased biogas production and methane. The removal efficiency of soluble COD is independent of HRT for OLR of 6 gCOD/L.d and HRT conditions tested (24, 12, 5, 3 and 1 day). COD Removal values achieved are slightly higher than the values of the vinasse anaerobic biodegradability of observed at 50%. Generally, reduction of HRT or vinasse dilution does not present a significant effect on the removal of the soluble organic matter; however if it occurs in the removal of sulfate reducing indirectly its toxicity. The thermoplastic support inoculated in FBA reactor and fed with raw vinasse, acted as a filter, in addition to obtaining good results in COD removal, but given the size and height of the filling slows evacuation of methane.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within the frame of the HiPER reactor, we propose and study a Self Cooled Lead Lithium blanket with two different cooling arrangements of the system First Wall – Blanket for the HiPER reactor: Integrated First Wall Blanket and Separated First Wall Blanket. We compare the two arrangements in terms of power cycle efficiency, operation flexibility in out-off-normal situations and proper cooling and acceptable corrosion. The Separated First Wall Blanket arrangement is superior in all of them, and it is selected as the advantageous proposal for the HiPER reactor blanket. However, it still has to be improved from the standpoint of proper cooling and corrosion rates

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new reactor concepts proposed in the Generation IV International Forum (GIF) are conceived to improve the use of natural resources, reduce the amount of high-level radioactive waste and excel in their reliability and safe operation. Among these novel designs sodium fast reactors (SFRs) stand out due to their technological feasibility as demonstrated in several countries during the last decades. As part of the contribution of EURATOM to GIF the CP-ESFR is a collaborative project with the objective, among others, to perform extensive analysis on safety issues involving renewed SFR demonstrator designs. The verification of computational tools able to simulate the plant behaviour under postulated accidental conditions by code-to-code comparison was identified as a key point to ensure reactor safety. In this line, several organizations employed coupled neutronic and thermal-hydraulic system codes able to simulate complex and specific phenomena involving multi-physics studies adapted to this particular fast reactor technology. In the “Introduction” of this paper the framework of this study is discussed, the second section describes the envisaged plant design and the commonly agreed upon modelling guidelines. The third section presents a comparative analysis of the calculations performed by each organisation applying their models and codes to a common agreed transient with the objective to harmonize the models as well as validating the implementation of all relevant physical phenomena in the different system codes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La nitrificación-desnitrificación es el proceso biológico tradicional para la remoción de nitrógeno de las aguas residuales (Ruiz G. et al., 2006a), siendo fundamental ya que contribuye a controlar la eutroficación de los cuerpos receptores. Debido al deterioro que sobre la disponibilidad de los recursos han ejercido las actividades antropogénicas, es necesario orientar el tratamiento de las aguas residuales hacia tecnologías que ofrezcan el mayor grado de sustentabilidad, planteando innovaciones en el tratamiento. El presente proyecto de tesis doctoral versa sobre el estudio de la influencia de la relación C/N en la desnitrificación y metanogénesis de aguas residuales urbanas en un reactor anaeróbico de lecho fluidizado inverso (RLFI). Previamente a la realización de las pruebas experimentales de variación de la relación C/N, se llevó a cabo la etapa de arranque del RLFI la cual se inició en modo batch, favoreciendo la formación y adhesión de biopelícula al medio de soporte utilizado (Extendosphere). Después, sobrevino la operación en modo continuo desde una carga volumétrica aplicada (CVA) de 0.5 g DQOs/L⋅d hasta alcanzar 4 g DQOs/L⋅d, carga volumétrica a la cual se logró la plena estabilización del reactor, siendo la alta variabilidad de la concentración de DQOs en el agua residual urbana de alimentación, la principal problemática que ocasionó retrasos en la estabilidad del reactor. A una CVA de 4 g DQOs/L⋅d en estado estacionario, el valor mínimo de eficiencia de remoción de DQOs fue del 32.36% y el máximo de 66.99%. En estas condiciones el porcentaje de metano presente en el biogás producido tuvo un valor medio de 85.57 ± 2.93%, siendo un valor alto comparado con otros porcentajes de metano encontrados en la digestión anaerobia de aguas residuales urbanas. El YCH4 tuvo un valor medio de 0.316 ± 0.110 LCH4/g DQOrem⋅día. Los porcentajes de metanización variaron en el rango de 20.50 a 100%, registrándose un valor medio de 73.42 ± 25.63%. La considerable variabilidad en el porcentaje de metanización se debió principalmente a que se presentaron eventos de lavado de soporte colonizado, lo cual propició que las actividades metabólicas fueran orientadas hacia formación de biopelícula (anabolismo) en vez de estar dirigidas hacia producción de metano (catabolismo). En relación a los ensayos con variación de la relación C/N, se manejaron relaciones DQOs/N-NO3 en el rango de 1.65 a 21.1 g DQOs/g N-NO3. La tasa de remoción anaerobia de DQOs se incrementó con la concentración de sustrato en una relación casi lineal, ajustándose a una cinética de primer orden, lo que regularmente se presenta a concentraciones bajas de sustrato. La eficiencia del proceso de desnitrificación fue por lo regular alta, incrementándose ligeramente con la concentración de DQOs en el influente, con valores en el rango de 73.8 a 99.1%. Por otra parte, la tasa de remoción por metanogénesis se incrementó con la concentración relativa de sustrato (es decir, a mayores relaciones DQOs/N-NO3), siendo más sensitiva la metanogénesis a la concentración relativa de sustrato que la desnitrificación. Conforme aumentó la relación DQOs/N-NO3, la desnitrificación, de ser la ruta metabólica principal de utilización de la materia orgánica (comparada con la metanización), empezó a combinarse con la metanización. De manera evidente, a las relaciones DQOs/N-NO3 probadas, se manifestaron más las actividades desnitrificantes, quedando reflejadas por el alto porcentaje de utilización de la DQOs removida hacia la desnitrificación. La relación experimental DQOs/N-NO3 a la cual se pudiera haber cumplido con el requerimiento de materia orgánica (en términos de DQOs) para la desnitrificación de nitratos en las aguas residuales urbanas tratadas resultó aproximadamente ser igual a 7.1 g DQOs/g N-NO3. A una CVA de 4 g DQOs/L⋅d, se obtuvo un diámetro promedio máximo de soporte colonizado igual a 266.106 ± 69.279 μm aunque, hay que indicarlo, se presentaron fluctuaciones, las cuales se reflejaron también en el espesor de la biopelícula, el cual tuvo un valor máximo de 50.099 μm y un valor promedio de 37.294 ± 11.199 μm. Estas fluctuaciones pudieron deberse a la existencia de corrientes preferenciales dentro del reactor, las cuales no permitieron un acceso equitativo del sustrato a todo el lecho. Nitrification-denitrification is the traditional biological process for nitrogen removal from wastewaters (Ruiz G. et al., 2006a), being fundamental since it contributes to control the eutrophication of the receiving waters. Due to the deterioration that on the availability of the aquatic resources the anthropogenic activities have exerted, it is necessary to orient the treatment of wastewaters towards technologies that offer the greater degree of sustainability, raising innovations in the treatment. This work studied the influence of C/N ratio on denitrification and methanogenesis of urban wastewaters in an inverse fluidized bed reactor (IFBR). Previously to the accomplishment of the experimental tests with variation of C/N ratio, the start up of the IFBR was carried out in batch way, encouraging the formation and adhesion of biofilm to Extendosphere, which it was used as support. The operation in continuous way carried out from an organic loading rate (OLR) of 0.5 g CODs/L ∙ d to 4 g CODs/L ∙ d, when the steady-state was reached. The high variability of the CODs of the urban wastewaters caused delays in the stability of the reactor. Once stationary state was reached, the removal efficiency of CODs ranged from 32.36 to 66.99% to 4 g CODs/L ∙ d. In these conditions the percentage of methane in produced biogas had an average value of 85.57 ± 2.93%, being a high value compared with other studies treating anaerobically urban wastewaters. The YCH4 had an average value of 0.316 ± 0.110 LCH4/g CODrem ∙ d. The percentage of methanisation ranged from 20.50 to 100%, with an average value of 73.42 ± 25.63%. The considerable variability in the methanisation percentage occurred mainly due events of wash-out of colonized support, which caused that the metabolic activities were oriented towards formation of biofilm (anabolism) instead of methane production (catabolism). Concerning the tests with variation of C/N ratio, CODs/NO3-N ratios from 1.65 to 21.1 g CODs/g NO3-N were proved. The CODs anaerobic removal rate increased with the substrate concentration in an almost linear relation, adjusting to a kinetic of first order, which regularly appears to low concentrations of substrate. Efficiency of the denitrification process was regularly high, and it increased slightly with the CODs concentration in the influent, ranging from 73.8 to 99.1%. On the other hand, the CODs removal rate by methanogenesis increased with the substrate relative concentration (e.g., to greater CODs/NO3-N ratios), being more sensitive the methanogenesis to the substrate relative concentration that the denitrification. When the CODs/NO3-N ratio increased, the denitrification, of being the main metabolic route of use of the organic matter (compared with the methanogenesis), began to be combined with the methanogenesis. Definitively, to the proven CODs/NO3-N ratios the denitrification processes were more pronounced, being reflected by the high percentage of use of the removed CODs towards denitrification. The experimental CODs/NO3-N ratio to which it was possible to have been fulfilled the requirement of organic matter (in terms of CODs) for the denitrification of nitrates in urban wastewaters turned out to be approximately 7.1 g CODs/g NO3-N. It was obtained a maximum average diameter of colonized support of 266.106 ± 69.279 μm to 4 g CODs/L ∙ d, although it is necessary to indicate that appeared fluctuations in the thickness of biofilm, which had a maximum value of 50.099 μm and an average value of 37.294 ± 11.199 μm. These fluctuations could be due to the existence of preferential currents within the reactor, which did not allow an equitable access of the substrate to all the bed.