894 resultados para quantitative ultrasound
Resumo:
Objective: To assess reproducibility and feasibility of amusculoskeletal ultrasound (US) score for rheumatoid arthritis amongrheumatologist with diverse expertise in US, working in private orhospital practice.Methods: The Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a semi-quantitative score for RA usingOMERACT criteria for synovitis and erosion. The score was taught torheumatologists trained in US through two workshops. Subsequently,they were encouraged to practice in their office. For the study, we used6 US machines of different quality, each with a different patient.19 readers randomly selected among rheumatologists who haveattended both workshops, were asked to score anonymously at leastone patient. To assess whether some factors influence the score, weasked each reader to answer questionnaire describing his experiencewith US.Results: 19 rheumatologists have performed 29 scans, each patienthaving been evaluated by 4 to 6 readers. Median time for examcompletion was 20 minutes (range 15 to 60 mn). 53% ofrheumatologists work in private practice. Graph 1 show the global greyscale score for each patient. Weighted kappa was calculated for eachpair of reader using stata11. Almost all kappa of poor agreement wereobtained with a low quality device or by an assessor who havepreviously performed less than 5 scores himself.Conclusions: This is the first study to show an US score for RAfeasible by rheumatologists with diverse expertise in US both in privateand hospital practice. Reproducibility seemed to be influenced by thequality of device and previous experience with the score.
Resumo:
A group of experts on schistosomiasis and ultrasonography discussed the experiences and results obtained with the Niamey-Belo Horizonte Protocol on Ultrasonography in Schistosomiasis. A series of recomendations about qualitative and quantitative data obtained by ultrasound in studies performed in Africa and Brazil are presented. Imunological, genetic and epidemiological studies must rely on ultrasound for the identification of patients with periportal thickening/fibrosis.
Resumo:
Dietary acid load from Western diets may be a risk factor for osteoporosis. It can be estimated by net endogenous acid production (NEAP). No data currently exists for NEAP estimates and bone indices in the very elderly (i.e. > or = 75 y). The aim of this study was to determine the association between NEAP estimates by using the potential renal acid load (PRAL) equation and quantitative bone ultrasound (QUS) measurements at the heel [broadband ultrasound attenuation (BUA)] in Caucasian women. We assessed NEAP and QUS in 401 very elderly Swiss ambulatory women. We evaluated dietary intake and NEAP estimates with a validated FFQ. QUS was measured using Achilles (Lunar). We identified 2 subgroups: 256 women (80.6 y +/- 3; BUA, 96.8 dB/MHz) with a fracture history and the remaining 145 (79.9 y SD 2.9; BUA, 101.7 dB/MHz) without. Women who reported having suffered a fracture had lower BUA (P < 0.001) than nonfractured women but did not differ in nutrient intakes and NEAP. Lower NEAP (P = 0.023) and higher potassium intake (P = 0.033) were correlated with higher BUA, which remained significant even after adjustment for age, BMI, and osteoporosis treatment. BUA was positively correlated with calcium (P = 0.016) and BMI (P < 0.001). Women who reported no fractures had no significant correlations between nutrient intake, NEAP, and BUA. Low nutritional acid load was correlated with higher BUA in very elderly women with a fracture history. Although relatively weak compared with age and BMI, this association was significant and may be an important additional risk factor that might be particularly relevant in frail patients with an already high fracture risk.
Resumo:
Osteoporosis is well recognized as a public health problem in industrialized countries. Because of the efficiency of new treatments to decrease fracture risk, it is of a major interest to detect the patients who should benefit from such treatments. A diagnosis of osteoporosis is necessary before to start a specific treatment. This diagnosis is based on the measurement of the skeleton (hip and spine) with dual X-ray absorptiometry, using diagnostic criteria established by the World Health Organisation (WHO). In Switzerland, indications for bone densitometry are limited to precise situations. This technique cannot be applied for screening. For this purpose, peripheral measurements and particularly quantitative ultrasounds of bone seem to be promising. Indeed, several prospective studies clearly showed their predictive power for hip fracture risk in women aged more than 65 years. In order to facilitate the clinical use of bone ultrasounds, thresholds of risk of fracture and osteoporosis of the hip will be shortly published. This will integrate bone ultrasound in a global concept including bone densitometry and its indications, but also other risk factors for osteoporosis recognized by the Swiss association against osteoporosis (ASCO).
Resumo:
OBJECTIVE: The primary aim of the study was to evaluate whether rheumatoid arthritis (RA) patients considered to be in remission according to clinical criteria sets still had persisting ultrasound (US) synovitis. We further intended to evaluate the capacity of our US score to discriminate between the patients with a clinically active disease versus those in remission. METHODS: This is an observational study nested within the Swiss Clinical Quality Management in Rheumatic Diseases (SCQM) rheumatoid arthritis cohort. A validated US score (SONAR score) based on a semi-quantitative B-mode and Doppler (PwD) score as part of the regular clinical workup by rheumatologists in different clinical settings was used. To define clinically relevant synovitis, the same score was applied to 38 healthy controls and the 90st percentile was used as cut-off for 'relevant' synovitis. RESULTS: Three hundred and seven patients had at least one US examination and concomitant clinical information on disease activity. More than a third of patients in both DAS28 and ACR/EULAR remission showed significant gray scale synovitis (P=0.01 and 0.0002, respectively) and PwD activity (P=0.005 and 0.0005, respectively) when compared to controls. The capacity of US to discriminate between the two clinical remission groups and patients with active disease was only moderate. CONCLUSION: This observational study confirms that many patients considered to be in clinical remission according the DAS and the ACR/EULAR definitions still have residual synovitis on US. The prognostic significance of US synovitis and the exact place of US in patients reaching clinical remission need to be further evaluated.
Resumo:
Background/Purpose: Since the end of 2009, an ultrasound scoring call SONAR has been implemented for RA patients as a routine tool in the SCQM registry (Swiss Clinical Quality Management registry for rheumatic diseases). A cross-sectional evaluation of patients with active disease and clinical remission according to the DAS28ESR and the novel ACR/EULAR remission criteria from 2010 clearly indicated a good correlational external validity of synovial pathologies with clinical disease activity in RA (2012 EULAR meeting. Objective: of this study was to evaluate the sensitivity to change of B-mode and Power-Doppler scores in a longitudinal perspective along with the changes in DAS28ESR in two consecutive visits among the patients included in the SCQM registry Methods: All patients who had at least two SONAR scores and simultaneous DAS28ESR evaluations between December 2009 and June 2012 were included in this study. The data came from 20 different operators working mostly in hospitals but also in private practices, who had received a previous teaching over 3 days in a reference center. The SONAR score includes a semi-quantitative B mode and Power-Doppler evaluation of 22 joints from 0 to 3, maximum 66 points for each score. The selection of these 22 joints was done in analogy to a 28 joint count and further restricted to joint regions with published standard ultrasound images. Both elbows and wrist joints were dynamically scanned from the dorsal and the knee joints from a longitudinal suprapatellar view in flexion and in joint extension. The bilateral evaluation of the second to fifth metacarpophalangeal and proximal interphalangeal joints was done from a palmar view in full extension, and the Power-Doppler scoring from a dorsal view with hand and finger position in best relaxation. Results: From the 657 RA patients with at least one score performed, 128 RA patients with 2 or more consultations of DAS28ESR, and a complete SONAR data set could be included. The mean (SD) time between the two evaluations was 9.6 months (54). The mean (SD) DAS28ESR was: 3.5 (1.3) at the first visit and was significantly lower (mean 3.0, SD.2.0, p:_0.0001) at the second visit. The mean (SD) of the total B mode was 12 (9.5) at baseline and 9.6 (7.6) at follow-up (p_0.0004). The Power-Doppler score at entry was 2.9 (5.7) and 1.9 (3.6), at the second visit, p _0.0001. The Pearson r correlation between change in DAS28ESR and the B mode was 0.44 (95% CI: 0.29, 0.57, p_ 0.0001),and 0.35 (95% CI: 0.16, 0.50, p _ 0.0002) for the Power-Doppler score,. Clinical relevant change in DAS (_1.1) was associated with a change of total B mode score _3 in 23/32 patients and a change a Doppler score _0.5 in 19/26. Conclusion: This study confirms that the SONAR score is sensitive to change and provides a complementary method of assessing RA disease activity to the DAS that could be very useful in daily practice.
Resumo:
The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.
Resumo:
This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.
Resumo:
OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care. METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers. RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion). CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.
Resumo:
Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3). The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men) were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021), as follows: 119 grade 1 (51.0%); 94 grade 2 (40.4%); and 20 grade 3 (8.6%). The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.
Resumo:
A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.
Resumo:
In the present study, we evaluated 42 wrists using the semi-quantitative scales power Doppler ultrasound (PDUS) and gray scale ultrasound (GSUS) with scores ranging from 0 to 3 and correlated the results with clinical, laboratory and radiographic data. Twenty-one patients (17 women and 4 men) with rheumatoid arthritis according to criteria of the American College of Rheumatology were enrolled in the study from September 2008 to July 2009 at Universidade Estadual de Campinas (UNICAMP). The average disease duration was 14 months. The patients were 66.6% Caucasians and 33.3% non-Caucasians, with a mean age of 42 and 41 years, respectively. A dorsal longitudinal scan was performed by ultrasound on the radiocarpal and midcarpal joints using GE LOGIQ XP-linear ultrasound and a high frequency (8-10 MHz) transducer. All patients were X-rayed, and the Larsen score was determined for the joints, with grades ranging from 0 to V. This study showed significant correlations between clinical, sonographic and laboratory data: GSUS and swollen right wrist (r = 0.546), GSUS of right wrist and swelling of left wrist (r = 0.511), PDUS of right wrist and pain in left wrist (r = 0.436), PDUS of right wrist and C-reactive protein (r = 0.466). Ultrasound can be considered a useful tool in the diagnosis of synovitis in early rheumatoid arthritis mainly when the anti-cyclic citrullinated peptide and rheumatoid factor are negative, and can lead to an early change in the therapeutic decision.
Resumo:
Introduction : Puisque le VEGF promeut l’inflammation et la néovascularisation des plaques athérosclérotiques, il pourrait contribuer à l’athérogénèse. Cependant, les données cliniques tentant de lier le VEGF à la maladie cardiaque athérosclérotique (MCAS) sont controversées. Nous avons investigué l’association entre les niveaux de VEGF et la sévérité de la MCAS. Méthode : Nous avons effectué une étude rétrospective transversale : 56 patients présentant une MCAS stable et 112 patients avec un syndrome coronarien aigue (SCA) ont été étudiés. Nous avons investigué la relation entre la charge athérosclérotique et les niveaux sériques de VEGF en utilisant la coronarographie par analyse quantitative (QCA) et avons évalué la morphologie des plaques athérosclérotiques en utilisant l’imagerie intravasculaire ultrasonore (IVUS). Résultats : Les niveaux de VEGF étaient plus bas chez les patients avec SCA que chez ceux avec MCAS stable. On observe une corrélation positive entre les niveaux de VEGF et le fardeau de la MCAS stable mesurée par le QCA Cumulative Coronary Stenosis Score - CCSS (Pearson r= 0,423 et p = 0,001). En analyse multivariée, les niveaux sériques de VEGF demeuraient prédicteurs du CCSS (p=0,003) des patients avec une MCAS stable. Nous avons observé une corrélation positive entre les niveaux de VEGF et le volume de plaque (Spearman r = 0.381, p = 0.035) ainsi que le pourcentage de volume d’athérome (Spearman r = 0.466, p = 0.008) mesurés par IVUS. Conclusions : Notre étude suggère un usage potentiel des niveaux sérique de VEGF comme biomarqueur de MCAS.
Resumo:
Speckle noise formed as a result of the coherent nature of ultrasound imaging affects the lesion detectability. We have proposed a new weighted linear filtering approach using Local Binary Patterns (LBP) for reducing the speckle noise in ultrasound images. The new filter achieves good results in reducing the noise without affecting the image content. The performance of the proposed filter has been compared with some of the commonly used denoising filters. The proposed filter outperforms the existing filters in terms of quantitative analysis and in edge preservation. The experimental analysis is done using various ultrasound images
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)