934 resultados para post-mortem interval. precocious eggs


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a case of an individual who stabbed himself through the heart with a large knife. Post mortem computed tomography (CT) and CT-angiography were used to assess the stab channel and to reconstruct the sequence of events. After penetrating injuries to the chest, both the intra-thoracic organs and the injury causing instrument may shift (e.g. from pnemothorax) and render forensic reconstructions more challenging. This case report illustrates the potentials and the pitfalls of CT for the reconstruction of penetrating injures to the chest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The questions of cause and manner of death are the most pressing ones in any forensic investigation. Traditionally, autopsy is the means to provide answers to these questions and despite the increasing use of CT and MR in the post-mortem setting, imaging has usually been an adjunct to forensic autopsy. Here we describe a case where post-mortem CT and MR were performed instead of autopsy, at the request of the responsible public prosecutor. The forensic conclusions derived from imaging, including cause and manner of death were accepted by the legal authorities, thereby setting precedence for future cases. This case represents a landmark in forensic medicine and is another step toward the full realization of minimally invasive forensic autopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. MATERIALS AND METHODS: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). RESULTS: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. CONCLUSION: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a case of exhumation, performed to investigate the circumstances and cause of death, one year after burial. Post mortem computed tomography (PMCT) revealed a mass in the pharynx. Imaging directed the subsequent forensic autopsy to careful retrieval of a foreign body. Histological analysis revealed a non-cellular composition. The detection of foreign material in the pharynx and its composition indicated accidental, rather than natural death, secondary to choking on food. This unusual case illustrates how post mortem imaging can significantly contribute to forensic investigation and stresses the importance of interdisciplinary collaboration between forensic pathologists and radiologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a case of a fatal speed flying accident in which the victim was electrocuted, burned and fell from a great height. Post-mortem imaging revealed acute appearing fractures on CT, without bone marrow oedema on MRI. Based on the known clinical imaging findings of bone marrow oedema in acute fractures, we concluded that the speed flyer died from electrocution rather than the fall and that the fractures occurred post-mortem. Radiological imaging augmented the reconstruction of the peri-mortem events. Further research is needed to assess whether bone marrow oedema in acute fractures is a reliable vital sign.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to explore the perception of the legal authorities regarding different report types and visualization techniques for post-mortem radiological findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the temperature dependency of tissue contrast on post mortem magnetic resonance (PMMR) images both objectively and subjectively; and to visually demonstrate the changes of image contrast at various temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The post-mortem use of modern imaging techniques such as multislice computed tomography (MSCT) is becoming increasingly important as an aid for conventional autopsy. This article presents a case of a 4-month-old boy who died from sudden infant death syndrome (SIDS) with intravascular gas after an intraosseus medication application documented by post-mortem MSCT. It is most likely that the gas entered the body during resuscitation. This case emphasises the advantage of post-mortem imaging as a complementary aid for the autopsy. We conclude that during emergency treatment, the medical staff should be aware of the possibility of causing a gas embolism following intraosseus medication. Resuscitation with an inserted, disconnected intraosseous needle should be avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Currently, in forensic medicine cross-sectional imaging gains recognition and a wide use as a non-invasive examination approach. Today, computed tomography (CT) or magnetic resonance imaging that are available for patients are unable to provide tissue information on the cellular level in a non-invasive manner and also diatom detection, DNA, bacteriological, chemical toxicological and other specific tissue analyses are impossible using radiology. We hypothesised that post-mortem minimally invasive tissue sampling using needle biopsies under CT guidance might significantly enhance the potential of virtual autopsy. The purpose of this study was to test the use of a clinically approved biopsy needle for minimally invasive post-mortem sampling of tissue specimens under CT guidance. MATERIAL AND METHODS: ACN III biopsy core needles 14 gauge x 160 mm with automatic pistol device were used on three bodies dedicated to research from the local anatomical institute. Tissue probes from the brain, heart, lung, liver, spleen, kidney and muscle tissue were obtained under CT fluoroscopy. RESULTS: CT fluoroscopy enabled accurate placement of the needle within the organs and tissues. The needles allowed for sampling of tissue probes with a mean width of 1.7 mm (range 1.2-2 mm) and the maximal length of 20 mm at all locations. The obtained tissue specimens were of sufficient size and adequate quality for histological analysis. CONCLUSION: Our results indicate that, similar to the clinical experience but in many more organs, the tissue specimens obtained using the clinically approved biopsy needle are of a sufficient size and adequate quality for a histological examination. We suggest that post-mortem biopsy using the ACN III needle under CT guidance may become a reliable method for targeted sampling of tissue probes of the body.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multislice-computed tomography (MSCT) and magnetic resonance imaging (MRI) are increasingly used for forensic purposes. Based on broad experience in clinical neuroimaging, post-mortem MSCT and MRI were performed in 57 forensic cases with the goal to evaluate the radiological methods concerning their usability for forensic head and brain examination. An experienced clinical radiologist evaluated the imaging data. The results were compared to the autopsy findings that served as the gold standard with regard to common forensic neurotrauma findings such as skull fractures, soft tissue lesions of the scalp, various forms of intracranial hemorrhage or signs of increased brain pressure. The sensitivity of the imaging methods ranged from 100% (e.g., heat-induced alterations, intracranial gas) to zero (e.g., mediobasal impression marks as a sign of increased brain pressure, plaques jaunes). The agreement between MRI and CT was 69%. The radiological methods prevalently failed in the detection of lesions smaller than 3mm of size, whereas they were generally satisfactory concerning the evaluation of intracranial hemorrhage. Due to its advanced 2D and 3D post-processing possibilities, CT in particular possessed certain advantages in comparison with autopsy with regard to forensic reconstruction. MRI showed forensically relevant findings not seen during autopsy in several cases. The partly limited sensitivity of imaging that was observed in this retrospective study was based on several factors: besides general technical limitations it became apparent that clinical radiologists require a sound basic forensic background in order to detect specific signs. Focused teaching sessions will be essential to improve the outcome in future examinations. On the other hand, the autopsy protocols should be further standardized to allow an exact comparison of imaging and autopsy data. In consideration of these facts, MRI and CT have the power to play an important role in future forensic neuropathological examination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiological identification is important in forensic medicine. Identification using comparison of individualising structures with ante- and post-mortem conventional radiographs has been known for a long time. New radiological procedures such as computed tomography (CT) and magnetic resonance imaging (MRI) are being increasingly used for identification. In this paper, a new comparative approach using various radiological methods is described and its application demonstrated. This new approach is the comparison of ante-mortem conventional radiographs with projected images calculated from post-mortem CT data. The identification procedure will be illustrated with reference to the frontal sinus and the pelvis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to identify the classic autopsy signs of drowning in post-mortem multislice computed tomography (MSCT). Therefore, the post-mortem pre-autopsy MSCT- findings of ten drowning cases were correlated with autopsy and statistically compared with the post-mortem MSCT of 20 non-drowning cases. Fluid in the airways was present in all drowning cases. Central aspiration in either the trachea or the main bronchi was usually observed. Consecutive bronchospasm caused emphysema aquosum. Sixty percent of drowning cases showed a mosaic pattern of the lung parenchyma due to regions of hypo- and hyperperfused lung areas of aspiration. The resorption of fresh water in the lung resulted in hypodensity of the blood representing haemodilution and possible heart failure. Swallowed water distended the stomach and duodenum; and inflow of water filled the paranasal sinuses (100%). All the typical findings of drowning, except Paltau's spots, were detected using post-mortem MSCT, and a good correlation of MSCT and autopsy was found. The advantage of MSCT was the direct detection of bronchospasm, haemodilution and water in the paranasal sinus, which is rather complicated or impossible at the classical autopsy.