948 resultados para positron emission tomography (PET)
Resumo:
Aims: To develop clinical protocols for acquiring PET images, performing CT-PET registration and tumour volume definition based on the PET image data, for radiotherapy for lung cancer patients and then to test these protocols with respect to levels of accuracy and reproducibility. Method: A phantom-based quality assurance study of the processes associated with using registered CT and PET scans for tumour volume definition was conducted to: (1) investigate image acquisition and manipulation techniques for registering and contouring CT and PET images in a radiotherapy treatment planning system, and (2) determine technology-based errors in the registration and contouring processes. The outcomes of the phantom image based quality assurance study were used to determine clinical protocols. Protocols were developed for (1) acquiring patient PET image data for incorporation into the 3DCRT process, particularly for ensuring that the patient is positioned in their treatment position; (2) CT-PET image registration techniques and (3) GTV definition using the PET image data. The developed clinical protocols were tested using retrospective clinical trials to assess levels of inter-user variability which may be attributed to the use of these protocols. A Siemens Somatom Open Sensation 20 slice CT scanner and a Philips Allegro stand-alone PET scanner were used to acquire the images for this research. The Philips Pinnacle3 treatment planning system was used to perform the image registration and contouring of the CT and PET images. Results: Both the attenuation-corrected and transmission images obtained from standard whole-body PET staging clinical scanning protocols were acquired and imported into the treatment planning system for the phantom-based quality assurance study. Protocols for manipulating the PET images in the treatment planning system, particularly for quantifying uptake in volumes of interest and window levels for accurate geometric visualisation were determined. The automatic registration algorithms were found to have sub-voxel levels of accuracy, with transmission scan-based CT-PET registration more accurate than emission scan-based registration of the phantom images. Respiration induced image artifacts were not found to influence registration accuracy while inadequate pre-registration over-lap of the CT and PET images was found to result in large registration errors. A threshold value based on a percentage of the maximum uptake within a volume of interest was found to accurately contour the different features of the phantom despite the lower spatial resolution of the PET images. Appropriate selection of the threshold value is dependant on target-to-background ratios and the presence of respiratory motion. The results from the phantom-based study were used to design, implement and test clinical CT-PET fusion protocols. The patient PET image acquisition protocols enabled patients to be successfully identified and positioned in their radiotherapy treatment position during the acquisition of their whole-body PET staging scan. While automatic registration techniques were found to reduce inter-user variation compared to manual techniques, there was no significant difference in the registration outcomes for transmission or emission scan-based registration of the patient images, using the protocol. Tumour volumes contoured on registered patient CT-PET images using the tested threshold values and viewing windows determined from the phantom study, demonstrated less inter-user variation for the primary tumour volume contours than those contoured using only the patient’s planning CT scans. Conclusions: The developed clinical protocols allow a patient’s whole-body PET staging scan to be incorporated, manipulated and quantified in the treatment planning process to improve the accuracy of gross tumour volume localisation in 3D conformal radiotherapy for lung cancer. Image registration protocols which factor in potential software-based errors combined with adequate user training are recommended to increase the accuracy and reproducibility of registration outcomes. A semi-automated adaptive threshold contouring technique incorporating a PET windowing protocol, accurately defines the geometric edge of a tumour volume using PET image data from a stand alone PET scanner, including 4D target volumes.
Resumo:
Background Over the past decade, molecular imaging has played a key role in the progression of drug delivery platforms from concept to commercialisation. Of the molecular imaging techniques commonly utilised, positron emission tomography (PET) can yield a breadth of information not easily accessible by other methodologies and when combined with other complementary imaging modalities, is a powerful tool for pre- and clinical development of therapeutics. However, very little research has focussed on the information available from complimentary imaging modalities. This paper reports on the data-rich methodologies of contrast enhanced PET/CT and PET/MRI for probing efficacy of polymer drug delivery platforms. Results The information available from an ExiTron nano 6000 contrast enhanced PET/CT and a gadolinium (Gd) enhanced PET/MRI image of a 64Cu labeled HBP in the same mouse was qualitatively compared. Conclusions Gd contrast enhanced PET/MRI offers a powerful methodology for investigating the distribution of polymer drug delivery platforms in vivo and throughout a tumour volume. Furthermore, information about depth of penetration away from primary blood vessels can be gleaned, potentially leading to development of more efficacious delivery vehicles for clinical use.
Resumo:
Context: Tumor-induced osteomalacia (TIO) is a rarely diagnosed disorder presenting with bone pain, fractures, muscle weakness, and moderate-to-severe hypophosphatemia resulting from fibroblast growth factor 23-mediated renal phosphate wasting. Tumors secreting fibroblast growth factor 23 are often small and difficult to find with conventional imaging. Objective: We studied the utility of 68Ga-DOTA-octreotate (DOTATATE) somatostatin receptor positron emission tomography (PET)/computed tomography (CT) imaging in the diagnosis of TIO. Design and Setting: A multicenter case series was conducted at tertiary referral hospitals. Patients and Methods: Six patients with TIO diagnosed between 2003 and 2012 in Australia were referred for DOTATATE PET imaging. We reviewed the clinical history, biochemistry, imaging characteristics, histopathology, and clinical outcome of each patient. Results: Each case demonstrated delayed diagnosis despite severe symptoms. DOTATATE PET/CT imaging demonstrated high uptake and localized the tumor with confidence in each case. After surgical excision, there was resolution of clinical symptoms and serum phosphate, except in one patient who demonstrated residual disease on PET/CT. All tumors demonstrated high somatostatin receptor subtype 2 cell surface receptor expression using immunohistochemistry. Conclusions: In patients with TIO, DOTATATE PET/CT can successfully localize phosphaturic mesenchymal tumors and may be a practical first step in functional imaging for this disorder. Serum phosphate should be measured routinely in patients with unexplained muscle weakness, bone pain, or stress fractures to allow earlier diagnosis of TIO. - See more at: http://press.endocrine.org/doi/abs/10.1210/jc.2012-3642#sthash.eXD0CopL.dpuf
Resumo:
O aumento exponencial dos gastos em saúde demanda estudos econômicos que subsidiem as decisões de agentes públicos ou privados quanto à incorporação de novas tecnologias aos sistemas de saúde. A tomografia de emissão de pósitrons (PET) é uma tecnologia de imagem da área de medicina nuclear, de alto custo e difusão ainda recente no país. O nível de evidência científica acumulada em relação a seu uso no câncer pulmonar de células não pequenas (CPCNP) é significativo, com a tecnologia mostrando acurácia superior às técnicas de imagem convencionais no estadiamento mediastinal e à distância. Avaliação econômica realizada em 2013 aponta para seu custo-efetividade no estadiamento do CPCNP em comparação à estratégia atual de manejo baseada no uso da tomografia computadorizada, na perspectiva do SUS. Sua incorporação ao rol de procedimentos disponibilizados pelo SUS pelo Ministério da Saúde (MS) ocorreu em abril de 2014, mas ainda se desconhecem os impactos econômico-financeiros decorrentes desta decisão. Este estudo buscou estimar o impacto orçamentário (IO) da incorporação da tecnologia PET no estadiamento do CPCNP para os anos de 2014 a 2018, a partir da perspectiva do SUS como financiador da assistência à saúde. As estimativas foram calculadas pelo método epidemiológico e usaram como base modelo de decisão do estudo de custo-efetividade previamente realizado. Foram utilizados dados nacionais de incidência; de distribuição de doença e acurácia das tecnologias procedentes da literatura e de custos, de estudo de microcustos e das bases de dados do SUS. Duas estratégias de uso da nova tecnologia foram analisadas: (a) oferta da PET-TC a todos os pacientes; e (b) oferta restrita àqueles que apresentem resultados de TC prévia negativos. Adicionalmente, foram realizadas análises de sensibilidade univariadas e por cenários extremos, para avaliar a influência nos resultados de possíveis fontes de incertezas nos parâmetros utilizados. A incorporação da PET-TC ao SUS implicaria a necessidade de recursos adicionais de R$ 158,1 (oferta restrita) a 202,7 milhões (oferta abrangente) em cinco anos, e a diferença entre as duas estratégias de oferta é de R$ 44,6 milhões no período. Em termos absolutos, o IO total seria de R$ 555 milhões (PET-TC para TC negativa) e R$ 600 milhões (PET-TC para todos) no período. O custo do procedimento PET-TC foi o parâmetro de maior influência sobre as estimativas de gastos relacionados à nova tecnologia, seguido da proporção de pacientes submetidos à mediastinoscopia. No cenário por extremos mais otimista, os IOs incrementais reduzir-se-iam para R$ 86,9 (PET-TC para TC negativa) e R$ 103,9 milhões (PET-TC para todos), enquanto no mais pessimista os mesmos aumentariam para R$ 194,0 e R$ 242,2 milhões, respectivamente. Resultados sobre IO, aliados às evidências de custo-efetividade da tecnologia, conferem maior racionalidade às decisões finais dos gestores. A incorporação da PET no estadiamento clínico do CPCNP parece ser financeiramente factível frente à magnitude do orçamento do MS, e potencial redução no número de cirurgias desnecessárias pode levar à maior eficiência na alocação dos recursos disponíveis e melhores desfechos para os pacientes com estratégias terapêuticas mais bem indicadas.
Resumo:
Purpose: Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non–small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. Methods and Materials: A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTVon the CT scan alone and then on the PET-CTscan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. Results: PET-CT improved the CI between observers when defining the GTVusing the PET-CT images compared with using CTalone for matched cases (median CI, 0.57 for CTand 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTVCT to GTVFUSED was 5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). Conclusion: PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.
Resumo:
The acquisition of radiotherapy planning scans on positron emission tomography (PET)-CT scanners requires the involvement of radiotherapy radiographers. This study assessed the radiation dose received by these radiographers during this process. Radiotherapy planning F- fluorodeoxyglucose (F-FDG) PET-CT scans were acquired for 28 non-small cell lung cancer patients. In order to minimise the radiation dose received, a two-stage process was used in which the most time-consuming part of the set-up was performed before the patient received their F-FDG injection. Throughout this process, the radiographers wore electronic personal dosemeters and recorded the doses received at different stages of the process. The mean total radiation dose received by a radiotherapy radiographer was 5.1±2.6 mSv per patient. The use of the two-stage process reduced the time spent in close proximity to the patient by approximately a factor of four. The two-stage process was effective in keeping radiation dose to a minimum. The use of a pre-injection set-up session reduces the radiation dose to the radiotherapy radiographers because of their involvement in PET-CT radiotherapy treatment planning scans by approximately a factor of three.
Resumo:
The introduction of functional data into the radiotherapy treatment planning process is currently the focus of significant commercial, technical, scientific and clinical development. The potential of such data from positron emission tomography (PET) was recognized at an early stage and was integrated into the radiotherapy treatment planning process through the use of image fusion software. The combination of PET and CT in a single system (PET/CT) to form an inherently fused anatomical and functional dataset has provided an imaging modality which could be used as the prime tool in the delineation of tumour volumes and the preparation of patient treatment plans, especially when integrated with virtual simulation. PET imaging typically using F-Fluorodeoxyglucose (F-FDG) can provide data on metabolically active tumour volumes. These functional data have the potential to modify treatment volumes and to guide treatment delivery to cells with particular metabolic characteristics. This paper reviews the current status of the integration of PET and PET/CT data into the radiotherapy treatment process. Consideration is given to the requirements of PET/CT data acquisition with reference to patient positioning aids and the limitations imposed by the PET/CT system. It also reviews the approaches being taken to the definition of functional/ tumour volumes and the mechanisms available to measure and include physiological motion into the imaging process. The use of PET data must be based upon a clear understanding of the interpretation and limitations of the functional signal. Protocols for the implementation of this development remain to be defined, and outcomes data based upon clinical trials are still awaited. © 2006 The British Institute of Radiology.
Resumo:
Objective: Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans.
Methods: 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTVCT) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice’s similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan.
Results: When the GTVCT delineated on the staging scan after both rigid registration and deformation was compared with the GTVCT on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p50.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration.
Conclusions: No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.
Resumo:
Protons of energies up to 37 MeV have been generated when ultra-intense lasers (up to 10(20) W cm(-2)) interact with hydrogen containing solid targets. These protons can be used to induce nuclear reactions in secondary targets to produce P-emitting nuclei of relevance to the nuclear medicine community, namely C-11 and N-13 via (p, n) and (p, alpha) reactions. Activities of the order of 200 kBq have been measured from a single laser pulse interacting with a thin solid target. The possibility of using ultra-intense lasers to produce commercial amounts of short-lived positron emitting sources for positron emission tomography (PET) is discussed. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014
Resumo:
Hypoxia, a condition of insufficient oxygen availability to support metabolism, occurs when the vascular supply is interrupted, as in stroke. The identification of the hypoxic and viable tissue in stroke as compared with irreversible lesions (necrosis) has relevant implications for the treatment of ischemic stroke. Traditionally, imaging by positron emission tomography (PET), using 15O-based radiotracers, allowed the measurement of perfusion and oxygen extraction in stroke, providing important insights in its pathophysiology. However, these multitracer evaluations are of limited applicability in clinical settings. More recently, specific tracers have been developed, which accumulate with an inverse relationship to oxygen concentration and thus allow visualizing the hypoxic tissue non invasively. These belong to two main groups: nitroimidazoles, and among these the 18F-Fluoroimidazole (18F-FMISO) is the most widely used, and the copper-based tracers, represented mainly by Cu-ATSM. While these tracers have been at first developed and tested in order to image hypoxia in tumors, they have also shown promising results in stroke models and preliminary clinical studies in patients with cardiovascular disorders, allowing the detection of hypoxic tissue and the prediction of the extent of subsequent ischemia and clinical outcome. These tracers have therefore the potential to select an appropriate subgroup of patients who could benefit from a hypoxia-directed treatment and provide prognosis relevant imaging. The molecular imaging of hypoxia made important progress over the last decade and has a potential for integration into the diagnostic and therapeutic workup of patients with ischemic stroke.
Resumo:
With the current limited availability of organs for transplantation, it is important to consider marginal donor candidates, including survivors of potentially curable malignancies such as lymphoma. The absence of refractory/recurrent residual disease at the time of brain death can be difficult to establish. Therefore, it is critical to have objective data to decide whether to proceed or not with organ procurement and transplantation. We report a unique situation in which (18)F-fluorodeoxyglucose positron emission tomography (PET) was used to rule out Hodgkin's lymphoma recurrence in a 33-year-old, heart-beating, brain-dead, potential donor with a past history of Hodgkin's disease and a persistent mediastinal mass. PET showed no significant uptake in the mass, allowing organ donation and transplantation to occur. We present a new means of evaluating potential brain-dead donors with a past history of some lymphoma, whereby PET may help transplant physicians by optimizing donation safety while rationalizing the inclusion of marginal donors.
Resumo:
The pathophysiology of neurodegenerative diseases (ND) such as Alzheimer's disease (AD) and Parkinson's disease (PD) has not yet been completely elucidated. However, in the past few years, there have been great knowledge advances about intra-and extracellular proteins that may display impaired function or expression in AD, PD and other ND, such as amyloid beta (AB), alpha-synuclein, tau protein and neuroinfiammatory markers. Recent developments in the imaging techniques of positron emission tomography (PET) and single photon emission computed tomography (SPECT) now allow the non-invasive tracking of such molecular targets of known relevance to ND in vivo. This article summarizes recent findings of PET and SPECT studies using these novel methods, and discusses their potential role in the field of drug development for ND as well as future clinical applications in regard to differential diagnosis of ND and monitoring of disease progression.
Resumo:
Diabetes mellitus umfasst eine heterogene Gruppe von Stoffwechselfunktionsstörungen, die durch hohe Blut-Glukose-Werte gekennzeichnet sind. Zwei Haupttypen von Diabetes mellitus wurden definiert: Typ 1- und Typ 2-Diabetes. Repaglinid ist ein neuer, schnell wirksamer, bei Typ 2-Diabetikern eingesetzter prandialer Glukose-Regulator mit einer kurzen Plasmahalbwertszeit (<1 Stunde) und der erste Vertreter der Carbamoylmethylbenzoesäure Familie, der in klinischen Studien getestet wurde. Die 18F- und 11C-markierten Repaglinid-Derivate (S)-2-(2-[18F]Fluorethoxy)-4-((3-methyl-1-(2-piperidin-1-yl-phenyl)-butylcarbamoyl)-methyl)-benzoesäure ([18F]Fluorethoxy-desethoxy-Repaglinid) und (S)-2-([11C]Methoxy)-4-([3-methyl-1-(2-piperidin-1-yl-phenyl)-butyl-carba-moyl]-benzoesäure ([11C]Methoxy-desethoxy-Repaglinid) wurden als potentielle Tracer für die nicht-invasive Quantifizierung des Sulfonylharnstoffrezeptor-Typ1-Status (SUR-1) der Insulin-sezernierenden -Zellen mittels Positronen-Emissions-Tomographie (PET) synthetisiert. [18F]Fluorethoxy-desethoxy-Repaglinide konnte in einer radiochemischen Ausbeute (RCA) von 20% nach 135 Minuten mit einer radiochemischen Reinheit >98% unter Verwendung des sekundären Markierungsvorläufers 2-[18F]Fluorethyltosylat erhalten werden. Die spezifische Aktivität lag im Bereich von 50-60 GBq/µmol. Für die radioaktive Synthese des [11C]Methoxy-desethoxy-Repaglinids wurde der sekundäre Markierungsvorläufer [11C]Methyliodid verwendet. Der 11C-Radiotracer wurde in einer RCA von 35% (bezogen auf [11C]CO2) mit einer spezifischen Aktivität von 40-70 GBq/µmol erhalten. Um die Eigenschaften des fluorierten sowie des methoxylierten Repaglinids zu charakterisieren, wurde die Affinität beider Verbindungen zum humanen SUR-1 evaluiert. [19F]Fluorethoxy-desethoxy-Repaglinid und Methoxy-desethoxy-Repaglinid induzierten Verdrängungskurven mit Hill-Koeffizienten nahe 1 und ergaben Dissotiationskonstanten (KD) von 142 nM beziehungsweise 83 nM - vergleichsweise geringe Verluste relativ zu Original-Repaglinid. Die biologische Aktivität wurde mittels Insulin-Sekretionstests an isolierten Ratten-Inselzellen gezeigt und war ebenfalls mit der des Repaglinids vergleichbar. Schließlich wurde die Biodistribution des [18F]Fluorethoxy-desethoxy-Repaglinids in gesunden Sprague-Dawley-Ratten durch Messung der Konzentration der Verbindung in verschiedenen Organen nach intravenöser Injektion untersucht. Das pankreatische Gewebe zeigte im Zeitintervall zwischen 10 und 30 Minuten nach Injektion eine stabile Akkumulation von etwa 0.12% der injizierten Dosis. 50% dieser Tracer-Akkulmulation konnten durch zusätzliche Injektion von nicht-radioaktiv-markiertem Repaglinid verdrängt werden, was auf eine mögliche Eignung des [18F]Fluorethoxy-desethoxy-Repaglinids für in vivo-Untersuchungen mittels PET schließen lässt. Eine erste humane PET-Studie zeigte zwar ebenfalls eine stabile, allerdings nur geringere Akkumulation von [18F]Fluorethoxy-desethoxy-Repaglinid im Pankreas und eine überproportional hohe Aktivitätsanreicherung in der Leber. Die Radioaktivitäts-akkumulation im Blut fiel nach wenigen Minuten unter die des Pankreas.
Resumo:
In dieser Studie wurde anhand des Modells der Ratte das Gleichgewichtssystem auf cerebro-corticaler Ebene untersucht, und das Verhalten des Gehirns nach akuten sowie chronischen Ausfällen mit funktioneller Bildgebung untersucht. rnMit der Positronen-Emissions-Tomographie (PET) kann die Metabolismusrate bestimmter Gehirnareale gemessen werden. Narkotisierte Tiere wurden unter galvanischer vestibulärer Stimulation im PET gemessen und die Ergebnisse wurden mit Kontrollstimulations-Messungen verglichen. Es konnten verschiedene Areale, die eine erhöhte Stoffwechselaktivität aufwiesen, ermittelt werden. Dazu gehören der somatosensorische und der insuläre Cortex, Teile des auditorischen Cortexes, der anteriore cinguläre sowie der entorhinale Cortex. Subcorticale Strukturen wie der Hippocampus, die Amygdala sowie die latero-dorsalen thalamischen Kerne wiesen ebenfalls erhöhten Stoffwechsel unter vestibulärer Stimulation auf. rnBei dieser PET-Studie handelt es sich um die erste funktionell-bildgebende Studie, die Verarbeitung vestibulärer Informationen bei Ratten in vivo darstellt. Die anatomische Verbindung der gefundenen Areale wurde mit anterograden und retrograden neuronalen Tracings unterstützt. rnDarüber hinaus wurde markiertes Gewebe, welches die Verbindung zwischen thalamischen und cerebro-corticalen Kernen der vestibulären Verschaltung aufweist, immunhistochemisch auf dessen Neurotransmission hin untersucht. Das katecholaminergen und dem opioidergen System wurde untersucht. Eine Beteiligung katecholaminerger Transmitter konnte nicht nachgewiesen werden. Neurone im somatosensorischen Cortex, die positiv auf einen Opioid-Rezeptor-Antikörper getestet wurden erhalten anterograd markierte Terminale aus dem thalamischen Kern LDDM, der mittels der PET als vestibulär identifiziert werden konnte. rnBasierend auf den Ergebnissen der ersten bildgebenden Studie wurde in einer zweiten funktionell-bildgebenden Studie die zentral-vestibuläre Verschaltung unterbrochen, indem relevante thalamische Kerngebiete (LDDM, LDVL) elektrolytisch zerstört wurden. Die Stoffwechselaktivität wurde anschließend bei diesen Tieren an verschiedenen Zeitpunkten nach der Läsion im PET unter vestibulärer Stimulation gemessen. Die Stoffwechselaktivität dieser Tiere wurde mit der Stoffwechselaktivität von Kontroll-Tieren verglichen. rnBei dieser Studie wurde zum ersten Mal, mittels funktioneller Bildgebung gezeigt, welche Bereiche des Gehirns nach akuter und chronischer Läsion des vestibulären Systems an Kompensationsmechanismen beteiligt sind. Alle Gehirnareale, die in verschiedenen Zeitfenstern (1, 3, 7 und 20 Tage nach Läsion) erhöhten Metabolismus aufweisen, sind Teil der vestibulären Verschaltung. Es handelt sich dabei um Areale der Okulomotorik und des räumlichen Gedächtnisses: das Postsubiculum, den Colliculus superior, das mediale Corpus geniculatum, den entorhinalen Cortex sowie die Zona incerta.rn