973 resultados para posicionamento GPS
Resumo:
This work presents the development of low cost microprocessor-based equipment for generation of differential GPS correction signal, in real time, and configuration and supervision of the GPS base. The developed equipment contains a dedicated microcontroller connected to the GPS receiver, alphanumeric display and multifunction keyboard for configuration and operation of the system and communication interfaces. The electronic circuit has the function of receiving the information from GPS base; interpret them, converting the sentence in the RTCM SC-104 protocol. The microcontroller software makes the conversion of the signal received by the GPS base from the specific format to RTCM SC-104 protocol. The processing main board has two serials RS-232C standard interfaces. One of them is used for configuration and receiving the information generated by the GPS base. The other operates as output, sending the differential correction signal for the transmission system. The development of microprocessor-based equipment showed that it is possible the construction of a low cost private station for real time generation of differential GPS correction signal.
Resumo:
This work is part of a research under construction since 2000, in which the main objective is to measure small dynamic displacements by using L1 GPS receivers. A very sensible way to detect millimetric periodic displacements is based on the Phase Residual Method (PRM). This method is based on the frequency domain analysis of the phase residuals resulted from the L1 double difference static data processing of two satellites in almost orthogonal elevation angle. In this article, it is proposed to obtain the phase residuals directly from the raw phase observable collected in a short baseline during a limited time span, in lieu of obtaining the residual data file from regular GPS processing programs which not always allow the choice of the aimed satellites. In order to improve the ability to detect millimetric oscillations, two filtering techniques are introduced. One is auto-correlation which reduces the phase noise with random time behavior. The other is the running mean to separate low frequency from the high frequency phase sources. Two trials have been carried out to verify the proposed method and filtering techniques. One simulates a 2.5 millimeter vertical antenna displacement and the second uses the GPS data collected during a bridge load test. The results have shown a good consistency to detect millimetric oscillations.
Resumo:
Highly redundant or statically undetermined structures, such as a cable-stayed bridge, have been of particular concern to the engineering community nowadays because of the complex parameters that must be taken into account for healthy monitoring. The purpose of this study was to verify the reliability and practicability of using GPS to characterize dynamic oscillations of small span bridges. The test was carried out on a cable-stayed wood footbridge at Escola de Engenharia de Sao Carlos-Universidade de Sao Paulo, Brazil. Initially a static load trial was carried out to get an idea of the deck amplitude and oscillation frequency. After that, a calibration trial was carried out by applying a well known oscillation on the rover antenna to check the environment detectable limits for the method used. Finally, a dynamic load trial was carried out by using GPS and a displacement transducer to measure the deck oscillation. The displacement transducer was used just to confirm the results obtained by the GPS. The results have shown that the frequencies and amplitude displacements obtained by the GPS are in good agreement with the displacement transducer responses. GPS can be used as a reliable tool to characterize the dynamic behavior of large structures such as cable-stayed footbridges undergoing dynamic loads.
Resumo:
The most recent National Health Survey reports that more than 80% of women initiate breastfeeding, while recent studies describe initiation rates of more than 90%. Yet fewer than 50% of women continue to breastfeed for 6 months or longer. This is at odds with National Health and Medical Research Council recommendations that 80% of infants be exclusively breastfed for the first 6 months of life. Women are more likely to initiate and continue to breastfeed if their doctor supports and encourages them to do so. Conversely, women perceive a neutral attitude by doctors toward breastfeeding to be similar to a negative attitude. Therefore, while doctors may not perceive their support or encouragement to be a determining factor in a woman’s breastfeeding decisions, women often place great emphasis on their GP's attitude to breastfeeding and are much more likely to think that information provided by a doctor is important. No previous research in Australia has addressed the issue of how GPs perceive their roles and responsibilities regarding breastfeeding. As part of a larger research project investigating the breastfeeding skills and knowledge of general practice registrars, this article reports the results of qualitative interviews with eight general practice registrars and their views and beliefs about GPs’ responsibilities to breastfeeding women.
Resumo:
An investigation was undertaken to test the effectiveness of two procedures for recording boundaries and plot positions for scientific studies on farms on Leyte Island, the Philippines. The accuracy of a Garmin 76 Global Positioning System (GPS) unit and a compass and chain was checked under the same conditions. Tree canopies interfered with the ability of the satellite signal to reach the GPS and therefore the GPS survey was less accurate than the compass and chain survey. Where a high degree of accuracy is required, a compass and chain survey remains the most effective method of surveying land underneath tree canopies, providing operator error is minimised. For a large number of surveys and thus large amounts of data, a GPS is more appropriate than a compass and chain survey because data are easily up-loaded into a Geographic Information System (GIS). However, under dense canopies where satellite signals cannot reach the GPS, it may be necessary to revert to a compass survey or a combination of both methods.
Resumo:
Application of geographic information system (GIS) and global positioning system (GPS) technology in the Hlabisa community-based tuberculosis treatment programme documents the increase in accessibility to treatment after the expansion of the service from health facilities to include community workers and volunteers.
Resumo:
Background. The importance of general practice involvement in the care of attention-deficit/hyperactivity disorder (ADHD) is increasing due to the rising numbers of patients who present with the disorder. It has been suggested by consensus bodies that GPs should be identifying and referring patients at the severe end of the ADHD spectrum and managing those with less severe symptoms. However, GPs' views of their role in ADHD care are unknown. Objective. Our aim was to explore the attitudes and practices of Australian GPs towards the diagnosis and management of ADHD. Methods. We conducted a series of focus groups to explore GPs' beliefs regarding the causes of ADHD, their perceived role in ADHD diagnosis and management and their views on the role of behaviour therapies and pharmacotherapies in ADHD management. The subjects were 28 GPs in six focus groups. Results. GPs in this study did not want to be the primary providers of care for patients with ADHD. Participants indicated a preference to refer the patient to medical specialists for diagnosis and treatment of ADHD, and expressed low levels of interest in becoming highly involved in ADHD care. Concerns about overdiagnosis and misdiagnosis of the disorder, diagnostic complexity, time constraints, insufficient education and training about the disorder, and concerns regarding misuse and diversion of stimulant medications were the reasons cited for their lack of willingness. Conclusions. The Australian GPs in this study identify a role for themselves in ADHD care which is largely supportive in nature, and involves close liaison with specialist services.
Resumo:
Pesquisas apontam que a audiometria tonal de altas freqüências é um instrumento de diagnóstico precoce de alterações auditivas provenientes de agentes etiológicos. OBJETIVO: Verificar possíveis diferenças na avaliação audiométrica de altas freqüências de indivíduos com audição normal em função da pessoa que posiciona o fone de ouvido. CASUÍSTICA E MÉTODO: Estudo clínico e experimental na qual participaram 55 graduandos de uma Universidade do interior paulista, com audição normal. Para cada participante, foram realizadas duas testagens: na primeira o avaliador posicionou o fone no participante e na segunda, o próprio participante o fez. Utilizou-se um audiômetro AC40 calibrado para emitir tom puro nas freqüências de 10, 12.5 e 16 khz. RESULTADOS: A análise estatística por meio do coeficiente kappa (k) verificou a concordância entre as duas formas de posicionamento do fone, tendo como critério o valor de kappa>"0,70. Os resultados obtidos para ambas as orelhas ficaram abaixo desse valor, com média de k=0,50. DISCUSSÃO: Os resultados indicaram existência de risco de comprometimento da fidedignidade da avaliação em função da pessoa que ajusta o fone ao ouvido do examinado. CONCLUSÃO: Ao realizar audiometria deve-se levar em consideração a interferência dessa variável, para obtenção de resultados fidedignos.
Resumo:
Este estudo analisa estratégias de posicionamento da indústria calçadista da região de Franca (SP) com relação ao mercado interno. O trabalho apresenta um panorama da indústria calçadista nacional; em seguida, são apresentados os resultados de uma pesquisa empírica empreendida com empresas da região. Uma análise de conglomerados permitiu identificar quatro diferentes grupos de empresas com base em cinco variáveis (preços praticados, custos de produção, qualidade dos produtos, tecnologia de produção e capacidade de inovação), utilizando três diferentes estratégias: foco no segmento de calçados masculinos para um público de renda baixa (grupo 1), baixo custo (grupos 2 e 3), e diferenciação por meio de produtos de melhor qualidade e preços mais altos (grupo 4). Ao final, foram sugeridas alternativas estratégicas para as empresas consideradas em posição desfavorável em comparação às concorrentes.
Resumo:
Barreiras para a precisão em radioterapia: delimitação de volumes, erros de posicionamento, movimento dos órgãos. Revolução imagiológica na monitorização do tratamento: radiografia, EPID, CONE-BEAM CT. Objectivo do estudo: quantificar desvios de posicionamento em doentes com patologias de cabeça e pescoço e próstata nos tratamentos de Radioterapia.