857 resultados para phraseological unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this small-scale study was to measure, analyse and compare levels of acoustic noise, in a nine-bedded general intensive care unit (ICU). Measurements were undertaken using the Norsonic 116 sound level meter recording noise levels in the internationally agreed ‘A’ weighted scale. Noise level data were obtained and recorded at 5 min over 3 consecutive days. Results of noise level analysis indicated that mean noise levels within this clinical area was 56·42 dB(A), with acute spikes reaching 80 dB(A). The quietest noise level attained was that of 50 dB(A) during sporadic intervals throughout the 24-h period. Parametric testing using analysis of variance found a positive relationship (p ≤ 0·001) between the nursing shifts and the day of the week. However, Scheffe multiple range testing showed significant differences between the morning shift, and the afternoon and night shifts combined (p ≤ 0·05). There was no statistical difference between the afternoon and night shifts (p ≥ 0·05). While the results of this study may seem self-evident in many respects, what it has highlighted is that the problem of excessive noise exposure within the ICU continues to go unabated. More concerning is that the prolonged effects of excessive noise exposure on patients and staff alike can have deleterious effect on the health and well-being of these individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This small-scale study was undertaken to assess what knowledge nursing staff from a General Intensive Care Unit held with regard to noise exposure. To assess knowledge a self-administered multiple-choice questionnaire was used. Rigorous peer-review insured content validity. This study produced poor results in terms of the knowledge nurses held with regard to noise related issues in particular the psychophysiological effects and current legislation concerning its safe exposure. Non-parametric testing, using Kruskal–Wallis found no significant difference between nursing grades, however, descriptive analysis demonstrated that the staff nurse grade (D and E) performed better overall. Whilst the results of this study may seem self-evident in some respects, it is the problems of exposure to excessive noise levels for both patients and hospital personnel, which are clearly not understood. The effects noise exposure has on individuals for example decreased wound healing; sleep deprivation and cardiovascular stimulation must be of concern especially in terms of patient care but more so for nursing staff especially the effects noise levels can have on cognitive task performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the cardiac high dependency unit it is currently a member of the surgical team who makes the decision for a patient's chest drain to be removed after cardiac surgery. This has often resulted in delays in discharging one patient and therefore in admitting the next. A pilot study was carried out using a working standard that had been developed, incorporating an algorithmic model. The results have enabled nursing staff in a cardiac high dependency unit to undertake this responsibility independently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review question/objective The review objective is to synthesise the best available evidence on experiences and perceptions of family members of intensive care unit patients on the adequacy of end-of-life care, where life-support modalities have been withheld or withdrawn. Inclusion criteria Types of participants This review will consider studies that report on the experiences and perceptions of patients’ families on EOLC in the ICU, where life-support modalities have been withheld or withdrawn. The family is defined as “those who are closest to the patient... the family may include the biological family, family by acquisition, and the family of choice and friends”. Phenomena of interest The phenomena of interest for this review are the patients’ families experiences, perceptions or views on the adequacy of EOLC delivered in the ICU, where life-support modalities were withheld or withdrawn. These experiences may refer to the following views on domains of care considered important at the end-of-life in the ICU, which have been described already in the existing literature: timely, consistent, and compassionate communication, clinician availability, clinical decision making based on patients’ preferences, goals and values, physical care implemented to maintain patient comfort, holistic interdisciplinary care and bereavement care for families of patients who died.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Paper-based nutrition screening tools can be challenging to implement in the ambulatory oncology setting. The aim of this study was to determine the validity of the Malnutrition Screening Tool (MST) and a novel, automated nutrition screening system compared to a ‘gold standard’ full nutrition assessment using the Patient-Generated Subjective Global Assessment (PG-SGA). Methods An observational, cross-sectional study was conducted in an outpatient oncology day treatment unit (ODTU) within an Australian tertiary health service. Eligibility criteria were as follows: ≥18 years, receiving outpatient anticancer treatment and English literate. Patients self-administered the MST. A dietitian assessed nutritional status using the PGSGA, blinded to the MST score. Automated screening system data were extracted from an electronic oncology prescribing system. This system used weight loss over 3 to 6 weeks prior to the most recent weight record or age-categorised body mass index (BMI) to identify nutritional risk. Sensitivity and specificity against PG-SGA (malnutrition) were calculated using contingency tables and receiver operating curves. Results There were a total of 300 oncology outpatients (51.7 % male, 58.6±13.3 years). The area under the curve (AUC) for weight loss alone was 0.69 with a cut-off value of ≥1 % weight loss yielding 63 % sensitivity and 76.7 % specificity. MST (score ≥2) resulted in 70.6 % sensitivity and 69.5 % specificity, AUC 0.77. Conclusions Both the MST and the automated method fell short of the accepted professional standard for sensitivity (~≥80 %) derived from the PG-SGA. Further investigation into other automated nutrition screening options and the most appropriate parameters available electronically is warranted to support targeted service provision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Through clinical observation nursing staff of an inpatient rehabilitation unit identified a link between incontinence and undiagnosed urinary tract infections (UTIs). Further, clinical observation and structured continence management led to the realisation that urinary incontinence often improved, or resolved completely, after treatment with antibiotics. In 2009 a small study found that 30% of admitted rehabilitation patients had an undiagnosed UTI, with the majority admitted post-orthopaedic fracture. We suspected that the frequent use of indwelling urinary catheters (IDCs) in the orthopaedic environment may have been a contributing factor. Therefore, a second, more thorough, study was commenced in 2010 and completed in 2011. Aim The aim of this study was to identify what proportion of patients were admitted to one rehabilitation unit with an undiagnosed UTI over a 12-month period. We wanted to identify and highlight the presence of known risk factors associated with UTI and determine whether urinary incontinence was associated with the presence of UTI. Methods Data were collected from every patient that was admitted over a 12-month period (n=140). The majority of patients were over the age of 65 and had an orthopaedic fracture (36.4%) or stroke (27.1%). Mid-stream urine (MSU) samples, routinely collected and sent for culture and sensitivity as part of standard admission procedure, were used by the treating medical officer to detect the presence of UTI. A data collection sheet was developed, reviewed and trialled, before official data collection commenced. Data were collected as part of usual practice and collated by a research assistant. Inferential statistics were used to analyse the data. Results This study found that 25 (17.9%) of the 140 patients admitted to rehabilitation had an undiagnosed UTI, with a statistically significant association between prior presence of an IDC and the diagnosis of UTI. Urinary incontinence improved after the completion of treatment with antibiotics. Results further demonstrated a significant association between the confirmation of a UTI on culture and sensitivity and the absence of symptoms usually associated with UTI, such as burning or stinging on urination. Overall, this study suggests careful monitoring of urinary symptoms in patients admitted to rehabilitation, especially in patients with a prior IDC, is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobacterium kansasii is a pulmonary pathogen that has been grown readily from municipal water, but rarely isolated from natural waters. A definitive link between water exposure and disease has not been demonstrated and the environmental niche for this organism is poorly understood. Strain typing of clinical isolates has revealed seven subtypes with Type 1 being highly clonal and responsible for most infections worldwide. The prevalence of other subtypes varies geographically. In this study 49 water isolates are compared with 72 patient isolates from the same geographical area (Brisbane, Australia), using automated repetitive unit PCR (Diversilab) and ITS RFLP. The clonality of the dominant clinical strain type is again demonstrated but with rep-PCR, strain variation within this group is evident comparable with other reported methods. There is significant heterogeneity of water isolates and very few are similar or related to the clinical isolates. This suggests that if water or aerosol transmission is the mode of infection, then point source contamination likely occurs from an alternative environmental source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations: i) subtraction of the best linear fit from the data (detrending), and; ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences <0.16 m.s−2). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s−2), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s−2). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution is focused on plasma-enhanced chemical vapor deposition systems and their unique features that make them particularly attractive for nanofabrication of flat panel display microemitter arrays based on ordered patterns of single-crystalline carbon nanotip structures. The fundamentals of the plasma-based nanofabrication of carbon nanotips and some other important nanofilms and nanostructures are examined. Specific features, challenges, and potential benefits of using the plasma-based systems for relevant nanofabrication processes are analyzed within the framework of the "plasma-building unit" approach that builds up on extensive experimental data on plasma diagnostics and nanofilm/nanostructure characterization, and numerical simulation of the species composition in the ionized gas phase (multicomponent fluid models), ion dynamics and interaction with ordered carbon nanotip patterns, and ab initio computations of chemical structure of single crystalline carbon nanotips. This generic approach is also applicable for nanoscale assembly of various carbon nanostructures, semiconductor quantum dot structures, and nano-crystalline bioceramics. Special attention is paid to most efficient control strategies of the main plasma-generated building units both in the ionized gas phase and on nanostructured deposition surfaces. The issues of tailoring the reactive plasma environments and development of versatile plasma nanofabrication facilities are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault identification in industrial machine is a topic of major importance under engineering point of view. In fact, the possibility to identify not only the type, but also the severity and the position of a fault occurred along a shaft-line allows quick maintenance and shorten the downtime. This is really important in the power generation industry where the units are often of several tenths of meters long and where the rotors are enclosed by heavy and pressure-sealed casings. In this paper, an industrial experimental case is presented related to the identification of the unbalance on a large size steam turbine of about 1.3 GW, belonging to a nuclear power plant. The case history is analyzed by considering the vibrations measured by the condition monitoring system of the unit. A model-based method in the frequency domain, developed by the authors, is introduced in detail and it is then used to identify the position of the fault and its severity along the shaft-line. The complete model of the unit (rotor – modeled by means of finite elements, bearings – modeled by linearized damping and stiffness coefficients and foundation – modeled by means of pedestals) is analyzed and discussed before being used for the fault identification. The assessment of the actual fault was done by inspection during a scheduled maintenance and excellent correspondence was found with the identified one by means of authors’ proposed method. Finally a complete discussion is presented about the effectiveness of the method, even in presence of a not fine tuned machine model and considering only few measuring planes for the machine vibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4-Hexylbithienopyridine has been prepared as a novel electron-accepting monomer for conjugated polymers. To test its electronic properties, alternating copolymers with fluorene and indenofluorene polymers have been prepared. The copolymers displayed reduction potentials about 0.5 V lower than for the corresponding fluorene and indenofluorene homopolymers, indicating much improved electron-accepting properties. Analysis of the microscopic morphology of thin films of the copolymers by AFM shows that they lack the extensive supramolecular order seen with the homopolymers, which is attributed to the bithienopyridine units disrupting the π-stacking. LEDs using these polymers as the emitting layer produce blue-green emission with low turn-on voltages with aluminum electrodes confirming their improved electron affinity. The indenofluorene copolymer displayed an irreversible red shift in emission at high voltages, which is attributed to oxidation of the indenofluorene units. This red shift occurred at higher potentials than for indenofluorene homopolymers in LEDs, suggesting that the heterocyclic moieties offer some protection against electrically promoted oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Delirium is a common underdiagnosed condition in advanced cancer leading to increased distress, morbidity, and mortality. Screening improves detection but there is no consensus as to the best screening tool to use with patients with advanced cancer. Objective To determine the incidence of delirium in patients with advanced cancer within 72 hours of admission to an acute inpatient hospice using clinical judgement and validated screening tools. Method One hundred consecutive patients with advanced cancer were invited to be screened for delirium within 72 hours of admission to an acute inpatient hospice unit. Two validated tools were used, the Delirium Rating Scale-Revised 98 (DRS-R-98) and the Confusion Assessment Method (CAM) shortened diagnostic algorithm. These results were compared with clinical assessment by review of medical charts. Results Of 100 consecutive admissions 51 participated and of these 22 (43.1%) screened positive for delirium with CAM and/or DRS-R-98 compared to 15 (29.4%) by clinical assessment. Eleven (21.6%) were identified as hypoactive delirium and 5 (9.8%) as subsyndromal delirium. Conclusion This study confirms that delirium is a common condition in patients with advanced cancer.While there remains a lack of consensus regarding the choice of delirium screening tool this study supports theCAMas being appropriate. Further research may determine the optimal screening tool for delirium enabling the development of best practice clinical guidelines for routinemedical practice.