987 resultados para phase shift errors
Resumo:
Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE
Resumo:
Background: Cerebral autoregulation (CA) is a protective mechanism which maintains the steadiness of the cerebral blood flow (CBF) through a broad range of systemic blood pressure (BP). Acute hypertension has been shown to reduce the cerebrovascular adaptation to BP variations. However, it is still unknown whether CA is impaired in chronic hypertension. This study evaluated whether a strict control of BP affects the CA in patients with chronic hypertension, and compared a valsartan-based regimen to a regimen not inhibiting the renin-angiotensin-aldosterone system (non-RAAS). Methods: Eighty untreated patients with isolated systolic hypertension were randomized to valsartan 320 mg or to a non-RAAS regimen during 6 months. The medication was upgraded to obtain BP <140/90 mm Hg. Continuous recordings of arterial BP and CBF velocity (transcranial Doppler) were performed during periods of 5 minutes, at rest, and at different levels of alveolar CO(2) pressure provided by respiratory maneuvers. The dominant frequency of CBF oscillations was determined for each patient. Dynamic CA was measured as the mean phase shift between BP and CBF by cross-spectral analysis in the medium frequency and in the dominant CBF frequency. Results: Mean ambulatory 24-hour BP fell from 144/87 to 127/79 mm Hg in the valsartan group and from 144/87 to 134/81 mm Hg in the non-RAAS group (p = 0.13). Both groups had a similar reduction in the central BP and in the carotido-femoral pulse wave velocity. The average phase shift between BP fluctuations and CBF response at rest was normal at randomization (1.82 ± 0.08 s), which is considered a preserved autoregulation and increased to 1.91 ± 0.12 s at the end of study (p = 0.45). The comparison of both treatments showed no significant difference (-0.01 ± 0.17 s vs. 0.16 ± 0.16 s, p = 0.45) for valsartan versus non-RAAS groups. The plasmatic level of glycosylated hemoglobin decreased in the valsartan arm compared to the non-RAAS arm (-0.23 ± 0.06 vs. -0.08 ± 0.07%, p = 0.07). Conclusions: In elderly hypertensive men with isolated chronic systolic hypertension, CA seems efficient at baseline and is not significantly affected by 6 months of BP-lowering treatment. This suggests that the preventive effects of BP medication against stroke are not mediated through a restoration of the CA.
Resumo:
Digital holographic microscopy (DHM) is a noninvasive optical imaging technique that provides quantitative phase images of living cells. In a recent study, we showed that the quantitative monitoring of the phase signal by DHM was a simple label-free method to study the effects of glutamate on neuronal optical responses (Pavillon et al., 2010). Here, we refine these observations and show that glutamate produces the following three distinct optical responses in mouse primary cortical neurons in culture, predominantly mediated by NMDA receptors: biphasic, reversible decrease (RD) and irreversible decrease (ID) responses. The shape and amplitude of the optical signal were not associated with a particular cellular phenotype but reflected the physiopathological status of neurons linked to the degree of NMDA activity. Thus, the biphasic, RD, and ID responses indicated, respectively, a low-level, a high-level, and an "excitotoxic" level of NMDA activation. Moreover, furosemide and bumetanide, two inhibitors of sodium-coupled and/or potassium-coupled chloride movement strongly modified the phase shift, suggesting an involvement of two neuronal cotransporters, NKCC1 (Na-K-Cl) and KCC2 (K-Cl) in the genesis of the optical signal. This observation is of particular interest since it shows that DHM is the first imaging technique able to monitor dynamically and in situ the activity of these cotransporters during physiological and/or pathological neuronal conditions.
Resumo:
O constante crescimento de aplicações Internet têm vindo a contribuir para a necessidade do aumento de largura de banda na rede de acesso, o que fomenta a procura de novas soluções para redes de acesso de fibra óptica. Nesse contexto, soluções conhecidas como transmissores independentes do comprimento de onda (WIT wavelengthindependent transmitters) isto é, soluções para emissores que possam operar numa ampla gama de comprimentos de onda, poderão ser muito úteis. Sendo uma das mais promissoras o amplificador óptico semiconductor reflectivo (RSOA). Nesta dissertação foi implementado um modelo simplificado do RSOA que permite eficientemente determinar as suas características estáticas e dinâmicas. Foi também implementado um modelo de simulação, em Matlab, que permita estudar o desempenho de um sistema de comunicação por fibra óptica que utiliza RSOA e técnicas de modulação digital por desvio de fase com M estados (M-PSK M-ary Phase Shift Keying). Com o modelo de simulação foi avaliada qual a taxa de transmissão máxima atingível. A avaliação do desempenho foi feita através do cálculo da magnitude do vector erro (EVM Error Vector Magnitude), considerando os vários blocos implementados. Foi determinado o ponto óptimo de funcionamento do RSOA, sendo também avaliado do desempenho de sistema de transmissão, usando diferentes parâmetros do sinal M-PSK (M=4,16,64) com taxa de transmissão de 1Gbits/s e 10 Gbits/s considerando vários comprimentos de fibra óptica.
Resumo:
This paper presents a new method and circuit for the conversion of binary phase-shift keying (BPSK) signals into amplitude shift keying signals. The basic principles of the conversion method are the superharmonic injection and locking of oscillator circuits, and interference phenomena. The first one is used to synchronize the oscillators, while the second is used to generate an amplitude interference pattern that reproduces the original phase modulation. When combined with an envelope detector, the proposed converter circuit allows the coherent demodulation of BPSK signals without need of any explicit carrier recovery system. The time response of the converter circuit to phase changes of the input signal, as well as the conversion limits, are discussed in detail.
Resumo:
This paper demonstrates the feasibility of a new circuit for the conversion of binary phase-shift keying signals into amplitude-shift keying signals. In its simplest form, the converter circuit is composed by a power divider, a couple of second harmonic injection-locked oscillators, and a power combiner. The operation of the converter circuit relies on the frequency synchronization of both oscillators and the generation of an interference pattern by combining their outputs, which reproduces the original phase modulation. Two prototypes of the converter have been implemented. The first one is a hybrid version working in the 400-530-MHz frequency range. The second one has been implemented using multichip-module technology, and is intended to work in the 1.8-2.2-GHz frequency range.
Resumo:
In this paper, we present a model of a symmetric Brownian motor which changes the sign of its velocity when the temperature gradient is inverted. The velocity, external work, and efficiency are studied as a function of the temperatures of the baths and other relevant parameters. The motor shows a current reversal when another parameter (a phase shift) is varied. Analytical predictions and results from numerical simulations are performed and agree very well. Generic properties of this type of motor are discussed.
Resumo:
This paper deals with the goodness of the Gaussian assumption when designing second-order blind estimationmethods in the context of digital communications. The low- andhigh-signal-to-noise ratio (SNR) asymptotic performance of the maximum likelihood estimator—derived assuming Gaussiantransmitted symbols—is compared with the performance of the optimal second-order estimator, which exploits the actualdistribution of the discrete constellation. The asymptotic study concludes that the Gaussian assumption leads to the optimalsecond-order solution if the SNR is very low or if the symbols belong to a multilevel constellation such as quadrature-amplitudemodulation (QAM) or amplitude-phase-shift keying (APSK). On the other hand, the Gaussian assumption can yield importantlosses at high SNR if the transmitted symbols are drawn from a constant modulus constellation such as phase-shift keying (PSK)or continuous-phase modulations (CPM). These conclusions are illustrated for the problem of direction-of-arrival (DOA) estimation of multiple digitally-modulated signals.
Resumo:
NlmCategory="UNASSIGNED">Objects' borders are readily perceived despite absent contrast gradients, e.g. due to poor lighting or occlusion. In humans, a visual evoked potential (VEP) correlate of illusory contour (IC) sensitivity, the "IC effect", has been identified with an onset at ~90ms and generators within bilateral lateral occipital cortices (LOC). The IC effect is observed across a wide range of stimulus parameters, though until now it always involved high-contrast achromatic stimuli. Whether IC perception and its brain mechanisms differ as a function of the type of stimulus cue remains unknown. Resolving such will provide insights on whether there is a unique or multiple solutions to how the brain binds together spatially fractionated information into a cohesive perception. Here, participants discriminated IC from no-contour (NC) control stimuli that were either comprised of low-contrast achromatic stimuli or instead isoluminant chromatic contrast stimuli (presumably biasing processing to the magnocellular and parvocellular pathways, respectively) on separate blocks of trials. Behavioural analyses revealed that ICs were readily perceived independently of the stimulus cue-i.e. when defined by either chromatic or luminance contrast. VEPs were analysed within an electrical neuroimaging framework and revealed a generally similar timing of IC effects across both stimulus contrasts (i.e. at ~90ms). Additionally, an overall phase shift of the VEP on the order of ~30ms was consistently observed in response to chromatic vs. luminance contrast independently of the presence/absence of ICs. Critically, topographic differences in the IC effect were observed over the ~110-160ms period; different configurations of intracranial sources contributed to IC sensitivity as a function of stimulus contrast. Distributed source estimations localized these differences to LOC as well as V1/V2. The present data expand current models by demonstrating the existence of multiple, cue-dependent circuits in the brain for generating perceptions of illusory contours.
Resumo:
A high-frequency cyclonverter acts as a direct ac-to-ac power converter circuit that does not require a diode bidge rectifier. Bridgeless topology makes it possible to remove forward voltage drop losses that are present in a diode bridge. In addition, the on-state losses can be reduced to 1.5 times the on-state resistance of switches in half-bridge operation of the cycloconverter. A high-frequency cycloconverter is reviewed and the charging effect of the dc-capacitors in ``back-to-back'' or synchronous mode operation operation is analyzed. In addition, a control method is introduced for regulating dc-voltage of the ac-side capacitors in synchronous operation mode. The controller regulates the dc-capacitors and prevents switches from reaching overvoltage level. This can be accomplished by variating phase-shift between the upper and the lower gate signals. By adding phase-shift between the gate signal pairs, the charge stored in the energy storage capacitors can be discharged through the resonant load and substantially, the output resonant current amplitude can be improved. The above goals are analyzed and illustrated with simulation. Theory is supported with practical measurements where the proposed control method is implemented in an FPGA device and tested with a high-frequency cycloconverter using super-junction power MOSFETs as switching devices.
Resumo:
Acute cerebral hemorrhage (ACH) is an important clinical problem that is often monitored and studied with expensive devices such as computed tomography, magnetic resonance imaging, and positron emission tomography. These devices are not readily available in economically underdeveloped regions of the world, emergency departments, and emergency zones. We have developed a less expensive tool for non-contact monitoring of ACH. The system measures the magnetic induction phase shift (MIPS) between the electromagnetic signals on two coils. ACH was induced in 6 experimental rabbits and edema was induced in 4 control rabbits by stereotactic methods, and their intracranial pressure and heart rate were monitored for 1 h. Signals were continuously monitored for up to 1 h at an exciting frequency of 10.7 MHz. Autologous blood was administered to the experimental group, and saline to the control group (1 to 3 mL) by injection of 1-mL every 5 min. The results showed a significant increase in MIPS as a function of the injection volume, but the heart rate was stable. In the experimental (ACH) group, there was a statistically significant positive correlation of the intracranial pressure and MIPS. The change of MIPS was greater in the ACH group than in the control group. This high-sensitivity system could detect a 1-mL change in blood volume. The MIPS was significantly related to the intracranial pressure. This observation suggests that the method could be valuable for detecting early warning signs in emergency medicine and critical care units.
Resumo:
Le travail de nuit est associé avec plusieurs problèmes de santé. Le désalignement entre la phase circadienne et le cycle éveil-sommeil cause une désynchronie interne considérée comme la principale source de ces problèmes. L’ajustement circadien au travail de nuit est proposé comme contremesure. Normalement, l’ajustement circadien complet n’est pas recommandé puisqu’il engendre un désalignement circadien lors du retour à l’horaire de jour, causant des changements de phase répétés et la désynchronie interne. L’ajustement circadien partiel est alors proposé comme compromis afin de stabiliser les rythmes circadiens des travailleurs de nuit. Cependant, l’ampleur de l’ajustement circadien partiel nécessaire à l’amélioration du sommeil et de la vigilance demeure vague. Les ajustements partiels obtenus par délai ou avance de phase sont quantifiés non seulement par la phase du début de la sécrétion de mélatonine en lumière tamisée, mais également par le recoupement de l’épisode de sécrétion de mélatonine avec les périodes d’éveil et de sommeil. Les effets sur le sommeil et la vigilance d’un petit ajustement circadien partiel significatifs sont investigués dans une simulation de travail de nuit en laboratoire pour déterminer leurs implications cliniques. Les effets modestes suggèrent qu’un petit délai de phase peut réduire l’accumulation de la dette de sommeil, alors que l’avance de phase améliore subjectivement la vigilance et l’humeur nocturne. L’ampleur absolue du changement de phase est associée à une amélioration subjective de la vigilance et de l’humeur nocturne. Des études en milieux de travail permettraient de déterminer si ces stratégies sont applicables et bénéfiques aux travailleurs de nuit.
Resumo:
Irradiation of a Polymethyl methacrylate target using a pulsed Nd-YAG laser causes plasma formation in the vicinity of the target. The refractive index gradient due to the presence of the plasma is probed using phase-shift detection technique. The phase-shift technique is a simple but sensitive technique for the determination of laser ablation threshold of solids. The number density of laser generated plasma above the ablation threshold from Polymethyl methacrylate is calculated as a function of laser fluence. The number density varies from 2×1016 cm-3 to 2×1017 cm-3 in the fluence interval 2.8-13 J · cm-2.
Resumo:
Der Schwerpunkt dieser Arbeit liegt in der Anwendung funktionalisierter Mikrocantilever mit integrierter bimorpher Aktuation und piezo-resistiver Detektion als chemische Gassensoren für den schnellen, tragbaren und preisgünstigen Nachweis verschiedener flüchtiger Substanzen. Besondere Beachtung erfährt die Verbesserung der Cantilever-Arbeitsleistung durch den Betrieb in speziellen Modi. Weiterer Schwerpunkt liegt in der Untersuchung von spezifischen Sorptionswechselwirkungen und Anwendung von innovativen Funktionsschichten, die bedeutend auf die Sensorselektivität wirken.
Resumo:
The convective-diffusive transport of sub-micron aerosols in an oscillatory laminar flow within a 2-D single bifurcation is studied, using order-of-magnitude analysis and numerical simulation using a commercial software (FEMLAB®). Based on the similarity between momentum and mass transfer equations, various transient mass transport regimes are classified and scaled according to Strouhal and beta numbers. Results show that the mass transfer rate is highest at the carinal ridge and there is a phase-shift in diffusive transport time if the beta number is greater than one. It is also shown that diffusive mass transfer becomes independent of the oscillating outer flow if the Strouhal number is greater than one.