840 resultados para operational reliability
Resumo:
Market-based transmission expansion planning gives information to investors on where is the most cost efficient place to invest and brings benefits to those who invest in this grid. However, both market issue and power system adequacy problems are system planers’ concern. In this paper, a hybrid probabilistic criterion of Expected Economical Loss (EEL) is proposed as an index to evaluate the systems’ overall expected economical losses during system operation in a competitive market. It stands on both investors’ and planner’s point of view and will further improves the traditional reliability cost. By applying EEL, it is possible for system planners to obtain a clear idea regarding the transmission network’s bottleneck and the amount of losses arises from this weak point. Sequentially, it enables planners to assess the worth of providing reliable services. Also, the EEL will contain valuable information for moneymen to undertake their investment. This index could truly reflect the random behaviors of power systems and uncertainties from electricity market. The performance of the EEL index is enhanced by applying Normalized Coefficient of Probability (NCP), so it can be utilized in large real power systems. A numerical example is carried out on IEEE Reliability Test System (RTS), which will show how the EEL can predict the current system bottleneck under future operational conditions and how to use EEL as one of planning objectives to determine future optimal plans. A well-known simulation method, Monte Carlo simulation, is employed to achieve the probabilistic characteristic of electricity market and Genetic Algorithms (GAs) is used as a multi-objective optimization tool.
Resumo:
A large number of models have been derived from the two-parameter Weibull distribution and are referred to as Weibull models. They exhibit a wide range of shapes for the density and hazard functions, which makes them suitable for modelling complex failure data sets. The WPP and IWPP plot allows one to determine in a systematic manner if one or more of these models are suitable for modelling a given data set. This paper deals with this topic.
Resumo:
The present investigation assessed the reliability and validity of the scores of a subjective measure of desired aspirations and a behavioral measure of enacted aspirations. A sample of 5,655 employees was randomly split into two halves. Principal components analysis on Sample 1, followed by confirmatory factor analysis on Sample 2, confirmed the desired and enacted scales as distinct but related measures of managerial aspirations. The desired and enacted scales had satisfactory levels of internal consistency and temporal stability over a 1-year period. Relationships between the measures of desired and enacted managerial aspirations and both attitudinal and behavioral criteria, measured concurrently and 1 year later, provided preliminary support for convergent and discriminant validity for our sample. Desired aspirations demonstrated stronger validity than enacted aspirations. Although further examination of the psychometric properties of the scales is warranted, the present findings provide promising support for their validity and reliability for our sample.
The Las Campanas/AAT rich cluster survey - I. Precision and reliability of the photometric catalogue
Resumo:
The Las Campanas Observatory and Anglo-Australian Telescope Rich Cluster Survey (LARCS) is a panoramic imaging and spectroscopic survey of an X-ray luminosity-selected sample of 21 clusters of galaxies at 0.07 < z < 0.16. Charge-coupled device (CCD) imaging was obtained in B and R of typically 2 degrees wide regions centred on the 21 clusters, and the galaxy sample selected from the imaging is being used for an on-going spectroscopic survey of the clusters with the 2dF spectrograph on the Anglo-Australian Telescope. This paper presents the reduction of the imaging data and the photometric analysis used in the survey. Based on an overlapping area of 12.3 deg(2) we compare the CCD-based LARCS catalogue with the photographic-based galaxy catalogue used for the input to the 2dF Galaxy Redshift Survey (2dFGRS) from the APM, to the completeness of the GRS/APM catalogue, b(J) = 19.45. This comparison confirms the reliability of the photometry across our mosaics and between the clusters in our survey. This comparison also provides useful information concerning the properties of the GRS/APM. The stellar contamination in the GRS/APM galaxy catalogue is confirmed as around 5-10 per cent, as originally estimated. However, using the superior sensitivity and spatial resolution in the LARCS survey evidence is found for four distinct populations of galaxies that are systematically omitted from the GRS/APM catalogue. The characteristics of the 'missing' galaxy populations are described, reasons for their absence examined and the impact they will have on the conclusions drawn from the 2dF Galaxy Redshift Survey are discussed.
Resumo:
The artificial chaperone method for protein refolding developed by Rozema et al. (Rozema, D.; Gellman, S. H. J. Am. Chem. Soc. 1995, 117 (8), 2373-2374) involves the sequential dilution of denatured protein into a buffer containing detergent (cetyltrimethylammonium bromide, CTAB) and then into a refolding buffer containing cyclodextrin WD). In this paper a simplified one-step artificial chaperone method is reported, whereby CTAB is added directly to the denatured solution, which is then diluted directly into a refolding buffer containing P-cyclodextrin (P-CD). This new method can be applied at high protein concentrations, resulting in smaller processing volumes and a more concentrated protein solution following refolding. The increase in achievable protein concentration results from the enhanced solubility of CTAB at elevated temperatures in concentrated denaturant. The refolding yields obtained for the new method were significantly higher than for control experiments lacking additives and were comparable to the yields obtained with the classical two-step approach. A study of the effect of beta-CD and CTAB concentrations on refolding yield suggested two operational regimes: slow stripping ( beta-CDXTABsimilar to1), most suited for higher protein concentrations, and fast stripping (beta-CD/CTABsimilar to2.7), best suited for lower protein concentrations. An increased chaotrope concentration resulted in higher refolding yields and an enlarged operational regime.
Resumo:
Objective To assess the validity and the reliability of the Portuguese version of the Delirium Rating Scale-Revised-98 (DRS-R-98). Methods The scale was translated into Portuguese and back-translated into English. After assessing its face validity, five diagnostic groups (n = 64; delirium, depression, dementia, schizophrenia and others) were evaluated by two independent researchers blinded to the diagnosis. Diagnosis and severity of delirium as measured by the DRS-R-98 were compared to clinical diagnosis, Mini-Mental State Exam, Confusion Assessment Method, and Clinical Global Impressions scale (CGI). Results Mean and rnedian DRS-R-98 total scores significantly distinguished delirium from the other groups (p < 0.001). Inter-rater reliability (ICC between 0.9 and 1) and internal consistency (alpha = 0.91) were very high. DRS-R-98 severity scores correlated highly with the CGI. Mean DRS-R-98 severity scores during delirium differed significantly (p < 0.01) from the post-treatment values. The area under the curve established by ROC analysis was 0.99 and using the cut-off Value of 20 the scale showed sensitivity and specificity of 92.6% and 94.6%, respectively. Conclusion The Portuguese version of the DRS-R-98 is a valid and reliable measure of delirium that distinguishes delirium from other disorders and is sensitive to change in delirium severity, which may be of great value for longitudinal studies. Copyright (c) 2007 John Wiley & Sons, Ltd.
Resumo:
The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.
Resumo:
Research on outcomes from psychiatric disorders has highlighted the importance of expressed emotion (EE), but its cost-effective measurement remains a challenge. This article describes development of the Family Attitude Scale (FAS), a 30-item instrument that can be completed by any informant. Its psychometric characteristics are reported in parents of undergraduate students and in 70 families with a schizophrenic member. The total FAS had high internal consistency in all samples, and reports of angry behaviour in FAS items showed acceptable inter-rater agreement. The FAS was associated with the reported anger, anger expression and anxiety of respondents. Substantial associations between the parents' FAS and the anger and anger expression of students was also observed. Parents of schizophrenic patients had higher FAS scores than parents of students, and the FAS was higher if disorder duration was longer or patient functioning was poorer. Hostility, high criticism and low warmth on the Camberwell Family Interview (CFI) were associated with a more negative FAS. The highest FAS in the family was a good predictor of a highly critical environment on the CFI. The FAS is a reliable and valid indicator of relationship stress and expressed anger that has wide applicability. (C) 1997 Elsevier Science Ireland Ltd.
Resumo:
Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.
Resumo:
The objective was to determine the reliability of isokinetic strength and endurance testing in the ankle joints of patients with intermittent claudication. Twenty-three patients with peripheral artery disease (PAD) and symptoms of intermittent claudication participated in the study. Isokinetic strength and endurance testing of the ankle joint were performed in symptomatic and asymptomatic legs on 3 separate days. Intraclass coefficient correlation of peak torque (PT) and total work (TW) ranged from 0.77 to 0.92 and 0.89 to 0.96, respectively. PT and TW increased significantly and similarly in both legs from day 1 to day 2 (PT: +42 +/- 84% in the symptomatic leg and +33 +/- 51% in the asymptomatic leg, p < 0.05;TW: +38 +/- 26% in the symptomatic leg and +26 +/- 50% in the asymptomatic leg, p < 0.05). In conclusion, isokinetic strength and endurance testing in the ankle joints of patients with PAD presents reliability coefficients ranging from 0.77 to 0.96. However, strength and endurance increased between the first and the other test sessions performed on separate days, suggesting that two test sessions are necessary for the accurate evaluation of strength and endurance in patients with PAD.
Resumo:
The objective of this prospective study was to perform a cross-cultural adaptation of the Functional Assessment Measure (FAM) into Brazilian Portuguese, and to assess the test-retest reliability. The instrument was translated, back-translated, pretested, and reviewed by a committee. The Brazilian version was assessed in 61 brain-injury patients. Intrarater and interrater reliability was verified by a test-retest procedure (intraclass correlation). Intrarater reliability was moderate-to-excellent; interrater reliability was moderate-to-excellent, with the exception of one item. The Brazilian version of the FAM has acceptable test-retest reliability. Results suggest the use of the Brazilian version of the FAM in the Brazilian population, for disability evaluation and outcome assessment. Further research is required to evaluate the psychometric properties of the scale. International Journal of Rehabilitation Research 34:89-91 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.