981 resultados para nose obstruction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the regulation of connexin expression by fluid pressure, we have studied the effects of elevated transmural urine pressure on Connexin43 (Cx43) and Cx26. We chose to focus on these two proteins out of the five connexins (Cx26, 43, 40, 37, and 45) which we found by RT-PCR to be expressed in the rat bladder, since in situ hybridization and immunofluorescence showed that Cx43 is the predominant connexin expressed by smooth muscle cells (SMC), whereas Cx26 is abundantly expressed only in the latter cell type. To evaluate whether these connexins are affected by changes in transmural urine pressure, we used a rat model of bladder outlet obstruction, in which a ligature is placed around the urethra. Under conditions of increased fluid pressure due to urine retention, we observed that the expression of both Cx43 and Cx26 increased at both transcript and protein levels, reaching a maximum 7-9 h after the ligature. Further analysis revealed that these changes were accounted for by a fourfold increase in Cx43 mRNA of SMC but not urothelial cell and by a fivefold increase in Cx26 mRNA of urothelium. Scrape-loading of propidium iodide showed that the latter change was paralleled by a twofold increase in coupling between urothelial cells. The data show that Cx43 and Cx26 are differentially regulated during bladder outlet obstruction and contribute to the response of the bladder wall to increased voiding pressure, possibly to control its elasticity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To refine the classic definition of, and provide a working definition for, congenital high airway obstruction syndrome (CHAOS) and to discuss the various aspects of long-term airway reconstruction, including the range of laryngeal anomalies and the various techniques for reconstruction. DESIGN: Retrospective chart review. PATIENTS: Four children (age range, 2-8 years) with CHAOS who presented to a single tertiary care children's hospital for pediatric airway reconstruction between 1995 and 2000. CONCLUSIONS: To date, CHAOS remains poorly described in the otolaryngologic literature. We propose the following working definition for pediatric cases of CHAOS: any neonate who needs a surgical airway within 1 hour of birth owing to high upper airway (ie, glottic, subglottic, or upper tracheal) obstruction and who cannot be tracheally intubated other than through a persistent tracheoesophageal fistula. Therefore, CHAOS has 3 possible presentations: (1) complete laryngeal atresia without an esophageal fistula, (2) complete laryngeal atresia with a tracheoesophageal fistula, and (3) near-complete high upper airway obstruction. Management of the airway, particularly in regard to long-term reconstruction, in children with CHAOS is complex and challenging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nose-horned viper (Vipera ammodytes) occurs in a large part of the south-eastern Europe and Asia Minor. Phylogenetic relationships were reconstructed for a total of 59 specimens using sequences from three mitochondrial regions (16S and cytochrome b genes, and control region, totalling 2308 bp). A considerable number of clades were observed within this species, showing a large genetic diversity within the Balkan peninsula. Splitting of the basal clades was evaluated to about 4 million years ago. Genetic results are in contradiction with presently accepted taxonomy based on morphological characters: V. a. gregorwallneri and V. a. ruffoi do not display any genetic difference compared with the nominotypic subspecies (V. a. ammodytes), involving that these subspecies can be regarded as synonyms. High genetic divergence in the central part of the Balkan peninsula is not concordant with low morphological differentiation. Finally, the extensive genetic diversity within the Balkan peninsula and the colonisation routes are discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility, efficacy, and tolerance of self-expanding metallic stent insertion under fluoroscopic guidance for palliation of symptoms related to malignant gastroduodenal obstruction. MATERIALS AND METHODS: Seventy-two patients (38 men, 34 women) aged 25-98 years (mean, 62 years) with duodenal (n = 43), antropyloric (n = 13), surgical gastrojejunostomy (n = 10), or pyloroduodenal (n = 6) malignant obstruction were referred for insertion of self-expanding metallic stents over a 6-year period. Stent insertion was performed with use of a peroral or transgastric approach when necessary (n = 11). RESULTS: Stents were successfully inserted in 70 of the 72 patients (97%) and provided symptom relief in 65 patients (90%). Inserted stents were mainly uncovered vascular (n = 55) or enteral (n = 10) Wallstents. One hundred eight stents were initially inserted: one, two, three, or four stents were indicated in 43, 17, nine, and one patient, respectively. Mean follow-up was 119 days (range, 4-513 days). Mean stent patency was 113 days (range, 4-513 days). Mean survival of patients was 120 days. During follow-up, stent obstruction occurred in seven patients as a result of tumoral overgrowth (n = 5) or ingrowth (n = 2). Complications occurred in 12 of the 72 patients (17%), including stent migration (n = 8), stent fracture (n = 1), duodenal perforation (n = 1), and death related to general anesthesia (n = 1). CONCLUSION: Despite a significant complication rate, self-expanding metallic stent insertion under fluoroscopic guidance appears to be a feasible and useful technique in the palliative management of malignant gastroduodenal obstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study aims to assess the predictive value of residual venous obstruction (RVO) for recurrent venous thrombo-embolism (VTE) in a study using D-dimer to predict outcome. DESIGN: This is a multicentre randomised open-label study. METHODS: Patients with a first episode of idiopathic VTE were enrolled on the day of anticoagulation discontinuation when RVO was determined by compression ultrasonography in those with proximal deep vein thrombosis (DVT) of the lower limbs. D-dimer was measured after 1 month. Patients with normal D-dimer did not resume anticoagulation while patients with abnormal D-dimer were randomised to resume anticoagulation or not. The primary outcome measure was recurrent VTE over an 18-month follow-up. RESULTS: A total of 490 DVT patients were analysed (after excluding 19 for different reasons and 118 for isolated pulmonary embolism (PE)). Recurrent DVT occurred in 19% (19/99) of patients with abnormal D-dimer who did not resume anticoagulation and 10% (31/310) in subjects with normal D-dimer (adjusted hazard ratio: 2.1; p = 0.02). Recurrences were similar in subjects either with (11%, 17/151) or without RVO (13%, 32/246). Recurrent DVT rates were also similar for normal D-dimer, with or without RVO, and for abnormal D-dimer, with or without RVO. CONCLUSIONS: Elevated D-dimer at 1 month after anticoagulation withdrawal is a risk factor for recurrence, while RVO at the time of anticoagulation withdrawal is not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The benefit of surgery on renal function in unilateral ureteropelvic junction stenosis (UPJS) is still debated. We evaluated renal function outcome after unilateral pyeloplasty in 53 children. MATERIALS AND METHODS: We retrospectively reviewed 123I-hippuran renography performed at diagnosis and 5 to 15 years (mean +/- SD 7 +/- 3 years) after successful pyeloplasty. UPJS was prenatally detected in 26 children because of urinary tract infection in 17 and miscellaneous reasons in 10. Relative function (RF) and absolute function were measured on background corrected renograms. Absolute function of the affected and contralateral kidneys was determined by an accumulation index (AI), representing the percent injected dose extracted by each kidney 30 to 90 seconds after the heart peak. RESULTS: Preoperatively 33 of the 53 UPJS kidneys had a decreased AI but only 8 had a RF of less than 40%, which was improved in 7 at followup. In addition, the AI improved in 29 kidneys, of which 19 (36%) normalized. Of the UPJS kidneys 14 had an initially decreased AI that remained abnormal at followup. In these kidneys preoperative RF was less than 40% in all. At followup RF was greater than 40% in 4 children, in whom the AI of the UPJS kidney did not improve but the AI of the contralateral one decreased from supranormal to normal. Seven contralateral kidneys had a supranormal AI, whereas the AI remained normal in 3, of which the RF in the UPJS kidney remained at less than 40%. The AI and RF were normal in 20 UPJS kidneys and remained normal. CONCLUSIONS: When normal, the AI and RF reflected renal function outcome similarly. The AI added relevant information in UPJS kidneys with impaired function, showing compensation of the contralateral kidney.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical computation of a viscid heat-conducting transonic flow over a generic commercial rocket profile with symmetric oversized nose part was carried out. It has been shown that at zero angle of attack for some free-streamvelocity value flow pattern loses its symmetry. This results in non-uniform pressure distribution on rocket surface in angle direction which may yield in additional oscillating stress on the rocket. Also it has been found that obtained non-symmetric flow patterns are stable for small velocity perturbations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of our study was to see whether an artificial olfactory system can be used as a nondestructive instrument to measure fruit maturity. In order to make an objective comparison, samples measured with our electronic nose prototype were later characterized using fruit quality techniques. The cultivars chosen for the study were peaches, nectarines, apples, and pears. With peaches and nectarines, a PCA analysis on the electronic nose measurements helped to guess optimal harvest dates that were in good agreement with the ones obtained with fruit quality techniques. A good correlation between sensor signals and some fruit quality indicators was also found. With pears, the study addressed the possibility of classifying samples regarding their ripeness state after different cold storage and shelf-life periods. A PCA analysis showed good separation between samples measured after a shelf-life period of seven days and samples with four or less days. Finally, the electronic nose monitored the shelf-life ripening of apples. A good correlation between electronic nose signals and firmness, starch index, and acidity parameters was found. These results prove that electronic noses have the potential of becoming a reliable instrument to assess fruit ripeness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous cannula orifice obstruction is an underestimated problem during augmented cardiopulmonary bypass (CPB), which can potentially be reduced with redesigned, virtually wall-less cannula designs versus traditional percutaneous control venous cannulas. A bench model, allowing for simulation of the vena cava with various affluent orifices, venous collapse and a worst case scenario with regard to cannula position, was developed. Flow (Q) was measured sequentially for right atrial + hepatic + renal + iliac drainage scenarios, using a centrifugal pump and an experimental bench set-up (afterload 60 mmHg). At 1500, 2000 and 2500 RPM and atrial position, the Q values were 3.4, 6.03 and 8.01 versus 0.77*, 0.43* and 0.58* l/min: p<0.05* for wall-less and the Biomedicus(®) cannula, respectively. The corresponding pressure values were -15.18, -31.62 and -74.53 versus -46.0*, -119.94* and -228.13* mmHg. At the hepatic position, the Q values were 3.34, 6.67 and 9.26 versus 2.3*, 0.42* and 0.18* l/min; and the pressure values were -10.32, -20.25 and -42.83 versus -23.35*, -119.09* and -239.38* mmHg. At the renal position, the Q values were 3.43, 6.56 and 8.64 versus 2.48*, 0.41* and 0.22* l/min and the pressure values were -9.64, -20.98 and -63.41 versus -20.87 -127.68* and -239* mmHg, respectively. At the iliac position, the Q values were 3.43, 6.01 and 9.25 versus 1.62*, 0.55* and 0.58* l/min; the pressure values were -9.36, -33.57 and -44.18 versus -30.6*, -120.27* and -228* mmHg, respectivly. Our experimental evaluation demonstrates that the redesigned, virtually wall-less cannulas, allowing for direct venous drainage at practically all intra-venous orifices, outperform the commercially available control cannula, with superior flow at reduced suction levels for all scenarios tested.