955 resultados para non-destructive sampling
Resumo:
Increasing attention is being paid to the possible development of non-invasive tests for the assessment of the quality of Fruits. We propose a novel non-destructive method for the measurement of the internal optical properties of fruits and vegetables by means of lime-resolved reflectance spectroscopy in the visible and NIR range. A Fully automated instrumentation for time-resolved reflectance measurements was developed. It is based on mode-locked laser sources and electronics for time-correlated single photon counting, and provides a time-resolution of 120-160 ps. The system was used to probe the optical properties of several species and varieties of Fruits and vegetables in the red and NIR range (650-1000 nm). In most Fruits, the absorption line shape is dominated by the absorption peak of water, centred around 970 nm. Generally, the absorption spectra also show the spectral features typical of chlorophyll, with maximum at 675 nm. In particular, for what concerns apples, variations in peak intensity are observed depending on the variety, the degree of ripeness as well as the position on the apple. For all the species and varieties considered, the transport scattering coefficient decreases progressively upon increasing the wavelength.
Resumo:
Woolliness (mealiness in other fruits) is a negative attribute of peach sensory texture that is a physiological disorder associated with inadequate cold storage. It is characterised by lack of crispness and juiciness without variation in the tissue water content (Harker and Hallet, 1992). Many attempts have been made to develop destructive instrumental procedures to detect mealiness and woolliness. Non-destructive procedures attempted include using nuclear magnetic resonance (Sonego et al., 1995). However, this technique has economical limitations and is not practical at present. Non-destructive impact tests and NIR are non-destructive techniques which have been used to assess internal characteristics of fruits (Chen and Sun, 1991). The objective of this study was to develop a novel non-destructive procedure to identify woolly peaches by combining impact and NIR approaches.
Resumo:
The increasing of quality fruit demanded by the consumers is originating an advance in the development and application of sensors capable of measuring parameters of quality (sugar, acids, firmness, etc) on a non destructive way. Some of these sensors are already operative for their use in laboratory and even in lines. The Physical Properties laboratory of the Polytechnic University of Madrid, is developing different sensors for their implementation in lines. One of them is a non destructive impact sensor to measure fruit firmness.
Resumo:
In recent years, the technology for measuring the diameter and height of standing trees has improved significantly. These enhancements allow estimation of the volume of standing trees using stem taper equations, which traditionally have been constructed with data from felled trees, in an accurate and economically feasible way. A nondestructive method was evaluated with data from 38 pines and was validated with data from another 38 pines, both in the Northern Iberian Range (Spain). The electronic dendrometer Criterion RD1000 (Laser Technology Inc.) and the laser hypsometer TruPulse (Laser Technology Inc.) were used due to their accuracy and interoperability. The methodology was valid (unbiased and precise) measuring from a distance similar to the height of the tree. In this distance, statistical criteria and plots based on the residuals showed no clear advantage in volume estimation with models fitted with data from destructive methods against models fitted with data from the proposed non-destructive technique. This methodology can be considered useful for individual volume estimation and for developing taper equations.
Resumo:
Assessment of laser peening induced effects on Ti6Al4V by destructive and non-destructive techniques
Resumo:
NMR can be considered a multi-scale multidimensional technology in the sense that it provides both spatial insight at macroscopic (MRI) or microscopic level (relaxometry), together with chemical characterization (HR-MAS). In this study 296 apples (from 4 cultivars) were MRI screened (20 slices per fruit) among which 7 fruits were used for metabolomic study by 1H HR MAS in order to assess various chemical shifts: malic acid, sucrose, glucose, fructose and ethanol. On the first season, tissue samples were taken from the sound and affected apples (near the core, centre and outer part of the mesocarp) belonging to sound and affected locations, while on the second season, tissue samples were focused on the comparison between sound and affected tissue. Beside, MRI and 2D non-destructive relaxometry (on whole fruits, and localized tissue) where performed on 72 and 12 apples respectively in order to compare features at macroscopic (tissue) and microscopic (subcellular) level. HR MAS shows higher content of ?-glucose, ?-glucose, malic acid and aromatic compounds in watercore affected tissues from both seasons, while sound tissue reflects higher sucrose. Microscopic (subcellular) degradation of tissue varies according to disorder development and is in good accordance with macroscopic characterization with MRI.
Resumo:
Apples can be considered as having a complex system formed by several structures at different organization levels: macroscale (mayor que100 ?m) and microscale (menor que100 ?m). This work implements 2D T1/T2 global and localized relaxometry sequences on whole apples to be able to perform an intensive non-destructive and non-invasive microstructure study. The 2D T1/T2 cross-correlation spectroscopy allows the extraction of quantitative information about the water compartmentation in different subcellular organelles. A clear difference is found as sound apples show neat peaks for water in different subcellular compartments, such as vacuolar, cytoplasmatic and extracellular water, while in watercore-affected tissues such compartments appear merged. Localized relaxometry allows for the predefinition of slices in order to understand the microstructure of a particular region of the fruit, providing information that cannot be derived from global 2D T1/T2 relaxometry.
Resumo:
Los pernos conectores aportan múltiples ventajas de uso, entre las que se encuentra el elevado margen de seguridad que ofrecen sus soldaduras ejecutadas mediante arco eléctrico. Estas soldaduras, aunque ampliamente fiables, son difícilmente comprobadas mediante ensayos no destructivos. Aparte de la inspección visual, que aporta gran información sobre la calidad de ejecución de la soldadura, el resto de ensayos no destructivos (líquidos penetrantes, partículas magnéticas, ultrasonidos, radiografías, etc.) resultan inviables en estos elementos. Por otro lado, los ensayos acústicos de piezas metálicas han existido siempre. Su comprobación se basaba en el análisis por medio de ¿un oído fino¿ del sonido resultante tras ser golpeado el elemento a evaluar. Con estas premisas se plantea el presente estudio de inspección de las soldaduras en pernos conectores mediante su espectro acústico. Analíticamente, la investigación se ha centrado en el cálculo informático de los primeros modos propios de vibración mediante elementos finitos. Se han modelizado diferentes grados de penetración de la soldadura mediante la modificación de las condiciones de contorno. Se ha observado que variando el número de movimientos coaccionados en los nodos pertenecientes a la soldadura se produce una reducción en su frecuencia de vibración.
Resumo:
Apples can be considered as having a complex system formed by several structures at different organization levels: macroscale (>100 μm) and microscale (<100 μm). This work implements 2D T1/T2 global and localized relaxometry sequences on whole apples to be able to perform an intensive non-destructive and non-invasive microstructure study. The 2D T1/T2 cross-correlation spectroscopy allows the extraction of quantitative information about the water compartmentation in different subcellular organelles. A clear difference is found as sound apples show neat peaks for water in different subcellular compartments, such as vacuolar, cytoplasmatic and extracellular water, while in watercore-affected tissues such compartments appear merged. Localized relaxometry allows for the predefinition of slices in order to understand the microstructure of a particular region of the fruit, providing information that cannot be derived from global 2D T1/T2 relaxometry.
Resumo:
This paper shows the results of an experimental analysis on the bell tower of “Chiesa della Maddalena” (Mola di Bari, Italy), to better understand the structural behavior of slender masonry structures. The research aims to calibrate a numerical model by means of the Operational Modal Analysis (OMA) method. In this way realistic conclusions about the dynamic behavior of the structure are obtained. The choice of using an OMA derives from the necessity to know the modal parameters of a structure with a non-destructive testing, especially in case of cultural-historical value structures. Therefore by means of an easy and accurate process, it is possible to acquire in-situ environmental vibrations. The data collected are very important to estimate the mode shapes, the natural frequencies and the damping ratios of the structure. To analyze the data obtained from the monitoring, the Peak Picking method has been applied to the Fast Fourier Transforms (FFT) of the signals in order to identify the values of the effective natural frequencies and damping factors of the structure. The main frequencies and the damping ratios have been determined from measurements at some relevant locations. The responses have been then extrapolated and extended to the entire tower through a 3-D Finite Element Model. In this way, knowing the modes of vibration, it has been possible to understand the overall dynamic behavior of the structure.
Resumo:
"November 1957."
Resumo:
National Highway Traffic Safety Administration, Office of Research and Development, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
"April 15, 1964."
Resumo:
The object of this work was to further develop the idea introduced by Muaddi et al (1981) which enables some of the disadvantages of earlier destructive adhesion test methods to be overcome. The test is non-destructive in nature but it does need to be calibrated against a destructive method. Adhesion is determined by measuring the effect of plating on internal friction. This is achieved by determining the damping of vibrations of a resonating specimen before and after plating. The level of adhesion was considered by the above authors to influence the degree of damping. In the major portion of the research work the electrodeposited metal was Watt's nickel, which is ductile in nature and is therefore suitable for peel adhesion testing. The base metals chosen were aluminium alloys S1C and HE9 as it is relatively easy to produce varying levels of adhesion between the substrate and electrodeposited coating by choosing the appropriate process sequence. S1C alloy is the commercially pure aluminium and was used to produce good adhesion. HE9 aluminium alloy is a more difficult to plate alloy and was chosen to produce poorer adhesion. The "Modal Testing" method used for studying vibrations was investigated as a possible means of evaluating adhesion but was not successful and so research was concentrated on the "Q" meter. The method based on the use of a "Q" meter involves the principle of exciting vibrations in a sample, interrupting the driving signal and counting the number of oscillations of the freely decaying vibrations between two known preselected amplitudes of oscillations. It was not possible to reconstruct a working instrument using Muaddi's thesis (1982) as it had either a serious error or the information was incomplete. Hence a modified "Q" meter had to be designed and constructed but it was then difficult to resonate non-magnetic materials, such as aluminium, therefore, a comparison before and after plating could not be made. A new "Q" meter was then developed based on an Impulse Technique. A regulated miniature hammer was used to excite the test piece at the fundamental mode instead of an electronic hammer and test pieces were supported at the two predetermined nodal points using nylon threads. This instrument developed was not very successful at detecting changes due to good and poor pretreatments given before plating, however, it was more sensitive to changes at the surface such as room temperature oxidation. Statistical analysis of test results from untreated aluminium alloys show that the instrument is not always consistent, the variation was even bigger when readings were taken on different days. Although aluminium is said to form protective oxides at room temperature there was evidence that the aluminium surface changes continuously due to film formation, growth and breakdown. Nickel plated and zinc alloy immersion coated samples also showed variation in Q with time. In order to prove that the variations in Q were mainly due to surface oxidation, aluminium samples were lacquered and anodised Such treatments enveloped the active surfaces reacting with the environment and the Q variation with time was almost eliminated especially after hard anodising. This instrument detected major differences between different untreated aluminium substrates.Also Q values decreased progressively as coating thicknesses were increased. This instrument was also able to detect changes in Q due to heat-treatment of aluminium alloys.