265 resultados para meridian
Resumo:
This study concerned development and validation of a simple and inexpensive method involving partial coherence interferometry for measuring retinal shape, and its use in exploring association between retinal shape and myopia. Retinal shapes estimates using partial coherence interferometry were validated against estimates obtained from magnetic resonance imaging. Steeper retinas were found along the horizontal than along the vertical meridian, in myopes than in emmetropes, and in East Asian myopes than in Caucasian myopes. The racial differences, combined with the high prevalence of myopia in East Asia, suggest that retinal shape may play a role in myopia development.
Resumo:
Purpose To evaluate the influence of cone location and corneal cylinder on RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Methods In this prospective study, 156 eyes from 134 patients were enrolled. Complete ophthalmologic examination including manifest refraction, Best spectacle visual acuity (BSCVA), slit-lamp biomicroscopy was performed and corneal topography analysis was done. According to the cone location on the topographic map, the patients were divided into central and paracentral cone groups. Trial RGP lenses were selected based on the flat Sim K readings and a ‘three-point touch’ fitting approach was used. Over contact lens refraction was performed, residual astigmatism (RA) was measured and best-corrected RGP visual acuities (RGPVA) were recorded. Results The mean age (±SD) was 22.1 ± 5.3 years. 76 eyes (48.6%) had central and 80 eyes (51.4%) had paracentral cone. Prior to RGP lenses fitting mean (±SD) subjective refraction spherical equivalent (SRSE), subjective refraction astigmatism (SRAST) and BSCVA (logMAR) were −5.04 ± 2.27 D, −3.51 ± 1.68 D and 0.34 ± 0.14, respectively. There were statistically significant differences between central and paracentral cone groups in mean values of SRSE, SRAST, flat meridian (Sim K1), steep meridian (Sim K2), mean K and corneal cylinder (p-values < 0.05). Comparison of BSCVA to RGPVA shows that vision has improved 0.3 logMAR by RGP lenses (p < 0.0001). Mean (±SD) RA was −0.72 ± 0.39 D. There were no statistically significant differences between RGPVAs and RAs of central and paracentral cone groups (p = 0.22) and (p = 0.42), respectively. Pearson's correlation analysis shows that there is a statistically significant relationship between corneal cylinder and BSCVA and RGPVA, However, the relationship between corneal cylinder and residual astigmatism was not significant. Conclusions Cone location has no effect on the RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Corneal cylinder and Sim K values influence RGP-corrected visual acuities but do not influence residual astigmatism.
Resumo:
Purpose. To characterize the changes occurring in choroidal thickness (ChT) across the posterior pole during accommodation using enhanced-depth imaging optical coherence tomography (OCT). Methods. Forty participants (mean age 21 ± 2 years) had measures of ChT and ocular biometry taken during accommodation to 0, 3, and 6 diopter (D) stimuli, with the Spectralis OCT and Lenstar biometer. A Badal optometer and cold mirror system was mounted on both instruments, allowing measurement collection while subjects viewed an external fixation target at varying accommodative demands. Results. The choroid exhibited significant thinning during accommodation to the 6 D stimulus in both subfoveal (mean change, −5 ± 7 μm) and parafoveal regions (P < 0.001). The magnitude of these changes varied by parafoveal meridian, with the largest changes seen in the temporal (−9 ± 12 μm) and inferotemporal (−8 ± 8 μm) meridians (P < 0.001). Axial length increased with accommodation (mean change, +5 ± 11 μm at 3 D, +14 ± 13 μm at 6 D), and these changes were weakly negatively associated with the choroidal changes (r2 = 0.114, P < 0.05). Conclusions. A small, but significant thinning of the choroid was observed at the 6 D accommodation demand, which was greatest in the temporal and inferotemporal parafoveal choroid, and increased with increasing eccentricity from the fovea. The regional variation in the parafoveal thinning corresponds to the distribution of the nonvascular smooth muscle within the uvea, which may implicate these cells as the potential mechanism by which the choroid thins during accommodation.
Resumo:
Objective To examine the association between glaucoma and motor vehicle collision (MVC) involvement among older drivers, including the role of visual field impairment that may underlie any association found. Design A retrospective population-based study Participants A sample of 2,000 licensed drivers aged 70 years and older who reside in north central Alabama. Methods At-fault MVC involvement for five years prior to enrollment was obtained from state records. Three aspects of visual function were measured: habitual binocular distance visual acuity, binocular contrast sensitivity and the binocular driving visual field constructed from combining the monocular visual fields of each eye. Poisson regression was used to calculate crude and adjusted rate ratios (RR) and 95% confidence intervals (CI). Main Outcomes Measures At-fault MVC involvement for five years prior to enrollment. Results Drivers with glaucoma (n = 206) had a 1.65 (95% confidence interval [CI] 1.20-2.28, p = 0.002) times higher MVC rate compared to those without glaucoma after adjusting for age, gender and mental status. Among those with glaucoma, drivers with severe visual field loss had higher MVC rates (RR = 2.11, 95% CI 1.09-4.09, p = 0.027), whereas no significant association was found among those with impaired visual acuity and contrast sensitivity. When the visual field was sub-divided into six regions (upper, lower, left, and right visual fields; horizontal and vertical meridians), we found that impairment in the left, upper or lower visual field was associated with higher MVC rates, and an impaired left visual field showed the highest RR (RR = 3.16, p = 0.001) compared to other regions. However, no significant association was found in deficits in the right side or along the horizontal or vertical meridian. Conclusions A population-based study suggests that older drivers with glaucoma are more likely to have a history of at-fault MVC involvement than those without glaucoma. Impairment in the driving visual field in drivers with glaucoma appears to have an independent association with at-fault MVC involvement, whereas visual acuity and contrast sensitivity impairments do not.
Resumo:
Titled "An Essay on Antimetaphoric Resistance", the dissertation investigates what is here being called "Counter-figures": a term which has in this context a certain variety of applications. Any other-than-image or other-than-figure, anything that cannot be exhausted by figuration (and that is, more or less, anything at all, except perhaps the reproducible images and figures themselves) can be considered "counter-figurative" with regard to the formation of images and figures, ideas and schemas, "any graven image, or any likeness of any thing". Singularity and radical alterity, as well as temporality and its peculiar mode of uniqueness are key issues here, and an ethical dimension is implied by, or intertwined with, the aesthetic. In terms borrowed from Paul Celan's "Meridian" speech, poetry may "allow the most idiosyncratic quality of the Other, its time, to participate in the dialogue". This connection between singularity, alterity and temporality is one of the reasons why Celan so strongly objects to the application of the traditional concept of metaphor to poetry. As Celan says, "carrying over [übertragen]" by metaphor may imply an unwillingness to "bear with [mittragen]" and to "endure [ertragen]" the poem. The thesis is divided into two main parts. The first consists of five distinct prolegomena which all address the mentioned variety of applications of the term "counter-figures", and especially the rejection or critique of either metaphor (by Aristotle, for instance) or the concept of metaphor (defined by Aristotle, and sometimes deemed "anti-poetic" by both theorists and poets). Even if we restrict ourselves to the traditional rhetorico-poetical terms, we may see how, for instance, metonymy can be a counter-figure for metaphor, allegory for symbol, and irony for any single trope or for any piece of discourse at all. The limits of figurality may indeed be located at these points of intersection between different types of tropes or figures, and even between figures or tropes and the "non-figurative trope" or "pseudo-figure" called catachresis. The second part, following on from the open-ended prolegomena, concentrates on Paul Celan's poetry and poetics. According to Celan, true poetry is "essentially anti-metaphoric". I argue that inasmuch as we are willing to pay attention to the "will" of the poetic images themselves (the tropes and metaphors in a poem) to be "carried ad absurdum", as Celan invites us to do, we may find alternative ways of reading poetry and approaching its "secret of the encounter", precisely when the traditional rhetorical instruments, and especially the notion of metaphor, become inapplicable or suspicious — and even where they still seem to impose themselves.
Resumo:
The effect of fungal endophyte (Neotyphodium lolii) infection on the performance of perennial ryegrass (Lolium perenne) growing under irrigation in a subtropical environment was investigated. Seed of 4 cultivars, infected with standard (common toxic or wild-type) endophyte or the novel endophyte AR1, or free of endophyte (Nil), was sown in pure swards, which were fertilised with 50 kg N/ha.month. Seasonal and total yield, persistence, and rust susceptibility were assessed over 3 years, along with details of the presence of endophyte and alkaloids in plant shoots. Endophyte occurrence in tillers in both the standard and AR1 treatments was above 95% for Bronsyn and Impact throughout and rose to that level in Samson by the end of the second year. Meridian AR1 only reached 93% while, in the standard treatment, the endophyte had mostly died before sowing. Nil Zendophyte treatments carried an average of ?0.6% infection throughout. Infection of the standard endophyte was associated with increased dry matter (DM) yields in all 3 years compared with no endophyte. AR1 also significantly increased yields in the second and third years. Over the full 3 years, standard and AR1 increased yields by 18% and 11%, respectively. Infection with both endophytes was associated with increased yields in all 4 seasons, the effects increasing in intensity over time. There was 27% better persistence in standard infected plants compared with Nil at the end of the first year, increasing to 198% by the end of the experiment, while for AR1 the improvements were 20 and 134%, respectively. The effect of endophyte on crown rust (Puccinia coronata) infection was inconsistent, with endophyte increasing rust damage on one occasion and reducing it on another. Cultivar differences in rust infection were greater than endophyte effects. Plants infected with the AR1 endophyte had no detectable ergovaline or lolitrem B in leaf, pseudostem, or dead tissue. In standard infected plants, ergovaline and lolitrem B were highest in pseudostem and considerably lower in leaf. Dead tissue had very low or no detectable ergovaline but high lolitrem B concentrations. Peramine concentration was high and at similar levels in leaf and pseudostem, but not detectable in dead material. Concentration was similar in both AR1 and standard infected plants. Endophyte presence appeared to have a similar effect in the subtropics as has been demonstrated in temperate areas, in terms of improving yields and persistence and increasing tolerance of plants to stress factors.
Resumo:
A thorough investigation of salt concentration dependence of lithium DNA fibres is made using X-ray diffraction. While for low salt the C-form pattern is obtained, crystalline B-type diffraction patterns result on increasing the salt concentration. The salt content in the gel (from which fibres are drawn) is estimated by equilibrium dialysis using the Donnan equilibrium principle. The salt range giving the best crystalline B pattern is determined. It is found that in this range meridional reflections occur on the fourth and sixth layer lines. In addition, the tenth layer meridian is absent at a particular salt concentration. These results strongly suggest the presence of non-helical features in the DNA molecule. Preliminary analysis of the diffraction patterns indicates a structural variability within the B-form itself. Further, the possibility of the structural parameters of DNA being similar in solid state and in solution is discussed.
Resumo:
A-DNA pattern, obtained using a flat plat camera, was indexed by Fuller Image on the basis of a c-face centred monoclinic cell with A = 22.24 Å, B = 40.62 Å, C = 28.15 Å and β = 97.0°. A precession photograph of A-DNA which gives an undistorted picture of the lattice, showed that the unit cell parameters as given by Fuller Image were not quite correct. The precession photograph showed a strong meridional reflection (R = 0.00 Å−1) on the 11th layer line. But the occurrence of the meridional reflection on the 11th layer line could not be explained on the basis of the cell parameters given by Fuller Image ; using those cell parameters the reflection which comes closest to the meridian on 11th layer line is at R = 0.025 Å−1. However, a simple interchange of a and b values accounted for the meridional reflection on 11th layer line. The corrected cell parameter refined against 28 strong spots are A = 40.75 Å, B = 22.07 Å, C = 28.16 Å and β = 97.5°. In the new unit cell of A-DNA, the packing arrangement of the two molecules is different from that in the old one. Nonetheless, our earlier contention is again reaffirmed that both right and left-handed A-DNA are stereochemically allowed and consistent with the observed fibre pattern.
Resumo:
Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.
Resumo:
VHF nighttime scintillations, recorded during a high solar activity period at a meridian chain of stations covering a magnetic latitude belt of 3°–21°N (420 km subionospheric points) are analyzed to investigate the influence of equatorial spread F irregularities on the occurrence of scintillation at latitudes away from the equator. Observations show that saturated amplitude scintillations start abruptly about one and a half hours after ground sunset and their onset is almost simultaneous at stations whose subionospheric points are within 12°N latitude of the magnetic equator, but is delayed at a station whose subionospheric point is at 21°N magnetic latitude by 15 min to 4 hours. In addition, the occurrence of postsunset scintillations at all the stations is found to be conditional on their prior occurrence at the equatorial station. If no postsunset scintillation activity is seen at the equatorial station, no scintillations are seen at other stations also. The occurrence of scintillations is explained as caused by rising plasma bubbles and associated irregularities over the magnetic equator and the subsequent mapping of these irregularities down the magnetic field lines to the F region of higher latitudes through some instantaneous mechanism; and hence an equatorial control is established on the generation of postsunset scintillation-producing irregularities in the entire low-latitude belt.
Resumo:
Bhatnagar and Rathna (Quar. Journ. Mech. Appl. Maths., 1963,16, 329) investigated the flows of Newtonian, Reiner-Rivlin and Rivlin-Ericksen fluids between two rotating coaxial cones. In case of the last two types of fluids, they predicted the breaking of secondary flow field in any meridian plane. We find that such breaking is avoided by the application of a sufficiently strong azimuthal magnetic field arising from a line current along the axis of the cones.
Resumo:
We consider the secondary flows arising in the motion of a Maxwell fluid between two rotating coaxial cones having the same vertex. We find that in any meridian plane passing through the common axis of the cones, the flow field is divided into two regions. Such a division of flow field was first reported by Bhatnagar and Rathna.
Resumo:
A lower-bound limit analysis formulation, by using two-dimensional finite elements, the three-dimensional Mohr-Coulomb yield criterion, and nonlinear optimization, has been given to deal with an axisymmetric geomechanics stability problem. The optimization was performed using an interior point method based on the logarithmic barrier function. The yield surface was smoothened (1) by removing the tip singularity at the apex of the pyramid in the meridian plane and (2) by eliminating the stress discontinuities at the corners of the yield hexagon in the pi-plane. The circumferential stress (sigma(theta)) need not be assumed. With the proposed methodology, for a circular footing, the bearing-capacity factors N-c, N-q, and N-gamma for different values of phi have been computed. For phi = 0, the variation of N-c with changes in the factor m, which accounts for a linear increase of cohesion with depth, has been evaluated. Failure patterns for a few cases have also been drawn. The results from the formulation provide a good match with the solutions available from the literature. (C) 2014 American Society of Civil Engineers.
Resumo:
The ultimate bearing capacity of a circular footing, placed over rock mass, is evaluated by using the lower bound theorem of the limit analysis in conjunction with finite elements and nonlinear optimization. The generalized Hoek-Brown (HB) failure criterion, but by keeping a constant value of the exponent, alpha = 0.5, was used. The failure criterion was smoothened both in the meridian and pi planes. The nonlinear optimization was carried out by employing an interior point method based on the logarithmic barrier function. The results for the obtained bearing capacity were presented in a non-dimensional form for different values of GSI, m(i), sigma(ci)/(gamma b) and q/sigma(ci). Failure patterns were also examined for a few cases. For validating the results, computations were also performed for a strip footing as well. The results obtained from the analysis compare well with the data reported in literature. Since the equilibrium conditions are precisely satisfied only at the centroids of the elements, not everywhere in the domain, the obtained lower bound solution will be approximate not true. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
The suppression method of vortex shedding from a circular cylinder has been studied experimentally in the Reynolds number range from 300 to 1600. The test is performed in a water channel. The model cylinder is 1 cm in diameter and 38 cm in length. A row of small rods of 0.18 cm in diameter and 1.5 cm in length are perpendicularly connected to the surface of the model cylinder and distributed along the meridian, The distance between the neighboring rods and the angle of attack of the rods can be changed so that the suppression effect on vortex shedding can be adjusted. The results show that vortex shedding can be suppressed effectively if the distance between the neighboring rods is smaller than 3 times and the cylinder diameter and the angle of attack is in the range of 30degreesless than or equal tobeta<90&DEG;.