961 resultados para medical applications


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Personalized nanomedicine has been shown to provide advantages over traditional clinical imaging, diagnosis, and conventional medical treatment. Using nanoparticles can enhance and clarify the clinical targeting and imaging, and lead them exactly to the place in the body that is the goal of treatment. At the same time, one can reduce the side effects that usually occur in the parts of the body that are not targets for treatment. Nanoparticles are of a size that can penetrate into cells. Their surface functionalization offers a way to increase their sensitivity when detecting target molecules. In addition, it increases the potential for flexibility in particle design, their therapeutic function, and variation possibilities in diagnostics. Mesoporous nanoparticles of amorphous silica have attractive physical and chemical characteristics such as particle morphology, controllable pore size, and high surface area and pore volume. Additionally, the surface functionalization of silica nanoparticles is relatively straightforward, which enables optimization of the interaction between the particles and the biological system. The main goal of this study was to prepare traceable and targetable silica nanoparticles for medical applications with a special focus on particle dispersion stability, biocompatibility, and targeting capabilities. Nanoparticle properties are highly particle-size dependent and a good dispersion stability is a prerequisite for active therapeutic and diagnostic agents. In the study it was shown that traceable streptavidin-conjugated silica nanoparticles which exhibit a good dispersibility could be obtained by the suitable choice of a proper surface functionalization route. Theranostic nanoparticles should exhibit sufficient hydrolytic stability to effectively carry the medicine to the target cells after which they should disintegrate and dissolve. Furthermore, the surface groups should stay at the particle surface until the particle has been internalized by the cell in order to optimize cell specificity. Model particles with fluorescently-labeled regions were tested in vitro using light microscopy and image processing technology, which allowed a detailed study of the disintegration and dissolution process. The study showed that nanoparticles degrade more slowly outside, as compared to inside the cell. The main advantage of theranostic agents is their successful targeting in vitro and in vivo. Non-porous nanoparticles using monoclonal antibodies as guiding ligands were tested in vitro in order to follow their targeting ability and internalization. In addition to the targeting that was found successful, a specific internalization route for the particles could be detected. In the last part of the study, the objective was to clarify the feasibility of traceable mesoporous silica nanoparticles, loaded with a hydrophobic cancer drug, being applied for targeted drug delivery in vitro and in vivo. Particles were provided with a small molecular targeting ligand. In the study a significantly higher therapeutic effect could be achieved with nanoparticles compared to free drug. The nanoparticles were biocompatible and stayed in the tumor for a longer time than a free medicine did, before being eliminated by renal excretion. Overall, the results showed that mesoporous silica nanoparticles are biocompatible, biodegradable drug carriers and that cell specificity can be achieved both in vitro and in vivo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Suurelle yleisölle lisäävä valmistustekniikka eli ns. 3D-tulostustekniikka näyttäytyy lehtien otsikoissa ja artikkeleissa esiin pulpahtavana ”muotiaiheena”, mutta sekä muovien 3D-tulostustekniikka että metallienkin vastaava valmistustekniikka on ollut olemassa maailmalla ja Suomessa 80-luvun puolivälistä alkaen. Yhdysvalloissa ja Saksassa tekniikkaa käytetään valmistavassa teollisuudessa toiminnallisten osien tuotannossa. Esimerkiksi lentokoneen suihkumoottorien osia ja lääketieteellisiä välineitä tehdään metallijauheesta lisäävän valmistuksen avulla. Itse asiassa eräs menetelmä metalliesineiden valmistamiseksi lasersäteen avulla keksittiin Suomessa ja sitä myös kehiteltiin täällä, mutta teollisuudenala lähti aikanaan nousuun Saksassa. Lisäävä valmistus on tällä hetkellä maailmanlaajuisesti eräs kiinnostavista tuotantotekniikoista, jonka uskotaan muuttavan monia asioita tuotteiden suunnittelussa, toiminnoissa ja valmistuksessa. Tämä tekniikka ei kiinnosta pelkästään valmistavaa teollisuutta, vaan tietotekniikan, lääketieteen, koruvalmistuksen ja muotoilun osaajat sekä uusien liiketoimintamallien kehittäjät ja logistiikka operaattorit ovat teknologiasta kiinnostuneita. Suomelle 3D-tulostustekniikka on suuri mahdollisuus, sillä maassamme on vahva teollinen tieto- ja viestintätekniikkaosaaminen sekä lisäksi olemme maassamme erikoistuneet varsin vaativien teollisiin laitteiden valmistukseen. Eräät suurimmista mahdollisuuksista tällä tekniikalla ovat toimitusketjuihin liittyvät muutokset. Uutta on, että pienetkin yritykset ja organisaatiot voivat soveltaa tätä tekniikkaa valmistuksessa ja jopa kehitellä täysin uusia tuotteita. On myös arvioitu, että lisäävän valmistuksen merkitys valmistustapoihin ja toimitusketjuihin voi olla suurempi kuin koskaan aikaisemmin minkään teknologisen uudistuksen kohdalla. Lisäävästä valmistuksesta usein puhutaankin kolmantena teollisena vallankumouksena juuri tämän takia. 3D-tulostuksen kustannuksia tarkasteltaessa on tärkeätä huomata että vain sulatetun jauheen määrä ratkaisee, ei käytettävän geometrian monimutkaisuus. Tämä erottaa perinteisen ja lisäävän valmistuksen toisistaan. Perinteisesti kappaleen keventäminen on maksanut ”ylimääräistä”, kun taas lisäävässä valmistuksessa kappaleen keveys on jopa kustannusta alentava tekijä. Valmistettavan kappaleen korkeus on yksi kriittisimpiä kustannuksiin vaikuttavia tekijöitä. Tämän vuoksi useamman kappaleen valmistus yhdellä kertaa parantaa kannattavuutta huomattavasti. Samalla kertaa voi ja itse asiassa kannattaakin valmistaa keskenään erilaisia kappaleita. Perinteiset valmistustavat sen sijaan ovat nykyajan vaatimuksille liian hitaita; ne joustavat huonosti, kun kyseessä on pienet, asiakaslähtöiset erät. Trendi on globaalisti kohden yksilöllisiä asiakaslähtöisiä tuotteita, jolloin myös valmistustekniikoiden on oltava joustavia pysyäkseen näiden vaatimusten perässä. Lisäävä valmistus sopii erityisesti hyvin piensarjatuotantoon. Suuremmissa valmistuserissä kuitenkin perinteiset tekniikat ovat kustannustehokkaampia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The role of chloride in the stabilization of the deoxy conformation of hemoglobin (Hb), the low oxygen affinity state, has been studied in order to identify the nature of this binding. Previous studies have shown that arginines 141α could be involved in the binding of this ion to the protein. Thus, des-Arg Hb, human hemoglobin modified by removal of the α-chain C-terminal residue Arg141α, is a possible model for studies of these interactions. The loss of Arg141α and all the salt bridges in which it participates is associated with subtle structural perturbations of the α-chains, which include an increase in the conformational flexibility and further shift to the oxy state, increasing oxygen affinity. Thus, this Hb has been the target of many studies of structural and functional behavior along with medical applications. In the present study, we describe the biochemical characterization of des-Arg Hb by electrophoresis, high-performance liquid chromatography and mass spectroscopy. The effects of chloride binding on the oxygen affinity and on the cooperativity to des-Arg Hb and to native human hemoglobin, HbA, were measured and compared. We confirm that des-Arg Hb presents high oxygen affinity and low cooperativity in the presence of bound chloride and show that the binding of chloride to des-Arg does not change its functional characteristics as observed with HbA. These results indicate that Arg141α may be involved in the chloride effect on Hb oxygenation. Moreover, they show that these residues contribute to lower Hb oxygen affinity to a level compatible with its biological function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Affiliation: Faculté de Médecine Vétérinaire, Université de Montréal

Relevância:

60.00% 60.00%

Publicador:

Resumo:

"Thèse présentée à la Faculté des études supérieures de l'Université de Montréal en vue de l'obtention du grade de Docteur en droit (LL.D.)"

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microwave properties of conductive polymers is crucial because of their wide areas of applications such as coating in reflector antennas, coating in electronic equipments, firequenry selective .surfaces, EMI materials, satellite communication links, microchip antennas, and medical applications. This work involves a comparative study of dielectric properties of selected conducting polymers such as polyaniline. poly(3,4-eth),lenedio.syt2iophene), polvthiophene, polvpvrrole. and pohparaphenylene diazomethine (PPDA) in microwave and DC,fields. The inicrowave properties such as dielectric constant, dielectric loss. absorption coefficient, heating coefficient, skin depth, and conductivity in the microwave frequency (S hand), and DC fields were compared. PEDOT and polccuiiline were found to exhibit excellent properties in DC field and microwave frequencies, which make thein potential materials in many of the alorenientioned applications

Relevância:

60.00% 60.00%

Publicador:

Resumo:

While the seriousness of the problem of antibiotic resistance is now recognized, the complex web of resistance linking humans, animals, and the environment is getting realized. More often, antibiotics are used as a preventive measure against diseases. Antibiotic use for agriculture leads to the increased resistance in the environment since antibiotics are inevitable element during agriculture/aquaculture and antibiotic residues are excreted as waste that is frequently spread onto farmland as organic fertilizer. Fecal bacteria survive long periods in the environment and spread through runoff into groundwater, rivers, and marine ecosystems.However, horizontal gene transfer occurs in the animals and guts of humans and in a variety of ecosystems, creating a pool of resistance in the rice fields and open waters. Even if people are not in direct contact with resistant disease through food animals, there are chances of contact with resistant fecal pathogens from the environment. Additionally, pathogens that are autochthonous to the environment can acquire resistance genes from the environment. Our study revealed that autochthonous , bacteria Vibrio spp gained antibiotic resistance in the environment. Further, it was evident that horizontal gene transfer occurs in Vibrio by means of plasmids, which further augments the gravity of the problem. Non-pathogenic bacteria may also acquire resistance genes and serve as a continuing source of resistance for other bacteria, both in the environment, and in the human gut. As the effectiveness of antibiotics for medical applications decline, the indiscriminate use of in aquaculture and in humans can have disastrous conditions in future due to horizontal gene transfer and the spread of resistant organisms: We must recognize and deal with the threat posed by overuse of antibiotics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The 20th century witnessed the extensive use of microwaves in industrial, scientific and medical fields. The major hindrance to many developments in the ISM field is the lack of knowledge about the effect of microwaves on materials used in various applications. The study of the interaction of microwaves with materials demanded the knowledge of the dielectric properties of these materials. However, the dielectric properties of many of these materials are still unknown or less studied. This thesis is an effort to shed light into the dielectric properties of some materials which are used in medical, scientific and industrial fields. Microwave phantoms are those materials used in microwave simulation applications. Effort has been taken to develop and characterize low cost, eco-friendly phantoms from Biomaterials and Bioceramics. The interaction of microwaves with living tissues paved way to the development of materials for electromagnetic shielding. Materials with good conductivity/absorption properties could be used for EMI shielding applications. Conducting polymer materials are developed and characterized in this context. The materials which are developed and analyzed in this thesis are Biomaterials, Bioceramics and Conducting polymers. The use of materials of biological origin in scientific and medical applications provides an eco-friendly pathway. The microwave characterization of the materials were done using cavity material perturbation method. Low cost and ecofriendly biomaterial films were developed from Arrowroot and Chitosan. The developed films could be used in applications such as microwave phantom material, capsule material in pharmaceutical applications, trans-dermal patch material and eco-friendly Band-Aids. Bioceramics with better bioresorption and biocompatibility were synthesized. Bioceramics such as Hydroxyapatite, Beta tricalcium phosphate and Biphasic Calcium Phosphate were studied. The prepared bioceramics could be used as phantom material representing Collagen, Bone marrow, Human abdominal wall fat and Human chest fat. Conducting polymers- based on Polyaniline, are developed and characterized. The developed materials can be used in electromagnetic shielding applications such as in anechoic chambers, transmission cables etc

Relevância:

60.00% 60.00%

Publicador:

Resumo:

14th Biennial International Symposium on Antennas and propagation Department of Electronics, Cochin University of Science & Technology, Cochin 682022, INDIA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work focuses on the analysis of the influence of environment on the relative biological effectiveness (RBE) of carbon ions on molecular level. Due to the high relevance of RBE for medical applications, such as tumor therapy, and radiation protection in space, DNA damages have been investigated in order to understand the biological efficiency of heavy ion radiation. The contribution of this study to the radiobiology research consists in the analysis of plasmid DNA damages induced by carbon ion radiation in biochemical buffer environments, as well as in the calculation of the RBE of carbon ions on DNA level by mean of scanning force microscopy (SFM). In order to study the DNA damages, besides the common electrophoresis method, a new approach has been developed by using SFM. The latter method allows direct visualisation and measurement of individual DNA fragments with an accuracy of several nanometres. In addition, comparison of the results obtained by SFM and agarose gel electrophoresis methods has been performed in the present study. Sparsely ionising radiation, such as X-rays, and densely ionising radiation, such as carbon ions, have been used to irradiate plasmid DNA in trishydroxymethylaminomethane (Tris buffer) and 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES buffer) environments. These buffer environments exhibit different scavenging capacities for hydroxyl radical (HO0), which is produced by ionisation of water and plays the major role in the indirect DNA damage processes. Fragment distributions have been measured by SFM over a large length range, and as expected, a significantly higher degree of DNA damages was observed for increasing dose. Also a higher amount of double-strand breaks (DSBs) was observed after irradiation with carbon ions compared to X-ray irradiation. The results obtained from SFM measurements show that both types of radiation induce multiple fragmentation of the plasmid DNA in the dose range from D = 250 Gy to D = 1500 Gy. Using Tris environments at two different concentrations, a decrease of the relative biological effectiveness with the rise of Tris concentration was observed. This demonstrates the radioprotective behavior of the Tris buffer solution. In contrast, a lower scavenging capacity for all other free radicals and ions, produced by the ionisation of water, was registered in the case of HEPES buffer compared to Tris solution. This is reflected in the higher RBE values deduced from SFM and gel electrophoresis measurements after irradiation of the plasmid DNA in 20 mM HEPES environment compared to 92 mM Tris solution. These results show that HEPES and Tris environments play a major role on preventing the indirect DNA damages induced by ionising radiation and on the relative biological effectiveness of heavy ion radiation. In general, the RBE calculated from the SFM measurements presents higher values compared to gel electrophoresis data, for plasmids irradiated in all environments. Using a large set of data, obtained from the SFM measurements, it was possible to calculate the survive rate over a larger range, from 88% to 98%, while for gel electrophoresis measurements the survive rates have been calculated only for values between 96% and 99%. While the gel electrophoresis measurements provide information only about the percentage of plasmids DNA that suffered a single DSB, SFM can count the small plasmid fragments produced by multiple DSBs induced in a single plasmid. Consequently, SFM generates more detailed information regarding the amount of the induced DSBs compared to gel electrophoresis, and therefore, RBE can be calculated with more accuracy. Thus, SFM has been proven to be a more precise method to characterize on molecular level the DNA damage induced by ionizing radiations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis concerns with the main aspects of medical trace molecules detection by means of intracavity laser absorption spectroscopy (ICLAS), namely with the equirements for highly sensitive, highly selective, low price, and compact size sensor. A novel two modes semiconductor laser sensor is demonstrated. Its operation principle is based on the competition between these two modes. The sensor sensitivity is improved when the sample is placed inside the two modes laser cavity, and the competition between the two modes exists. The effects of the mode competition in ICLAS are discussed theoretically and experimentally. The sensor selectivity is enhanced using external cavity diode laser (ECDL) configuration, where the tuning range only depends on the external cavity configuration. In order to considerably reduce the sensor cost, relative intensity noise (RIN) is chosen for monitoring the intensity ratio of the two modes. RIN is found to be an excellent indicator for the two modes intensity ratio variations which strongly supports the sensor methodology. On the other hand, it has been found that, wavelength tuning has no effect on the RIN spectrum which is very beneficial for the proposed detection principle. In order to use the sensor for medical applications, the absorption line of an anesthetic sample, propofol, is measured. Propofol has been dissolved in various solvents. RIN has been chosen to monitor the sensor response. From the measured spectra, the sensor sensitivity enhancement factor is found to be of the order of 10^(3) times of the conventional laser spectroscopy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to develop applications for z;isual interpretation of medical images, the early detection and evaluation of microcalcifications in digital mammograms is verg important since their presence is often associated with a high incidence of breast cancers. Accurate classification into benign and malignant groups would help improve diagnostic sensitivity as well as reduce the number of unnecessa y biopsies. The challenge here is the selection of the useful features to distinguish benign from malignant micro calcifications. Our purpose in this work is to analyse a microcalcification evaluation method based on a set of shapebased features extracted from the digitised mammography. The segmentation of the microcalcifications is performed using a fixed-tolerance region growing method to extract boundaries of calcifications with manually selected seed pixels. Taking into account that shapes and sizes of clustered microcalcifications have been associated with a high risk of carcinoma based on digerent subjective measures, such as whether or not the calcifications are irregular, linear, vermiform, branched, rounded or ring like, our efforts were addressed to obtain a feature set related to the shape. The identification of the pammeters concerning the malignant character of the microcalcifications was performed on a set of 146 mammograms with their real diagnosis known in advance from biopsies. This allowed identifying the following shape-based parameters as the relevant ones: Number of clusters, Number of holes, Area, Feret elongation, Roughness, and Elongation. Further experiments on a set of 70 new mammogmms showed that the performance of the classification scheme is close to the mean performance of three expert radiologists, which allows to consider the proposed method for assisting the diagnosis and encourages to continue the investigation in the sense of adding new features not only related to the shape

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: Los resultados de la remoción de tatuajes con láser de sesión a sesión según los parámetros utilizados son limitados en la literatura. Objetivo: Evaluar los cambios en el aclaramiento de tatuajes y factores asociados posterior a una sesión con láser y los efectos adversos. Materiales y Métodos: Estudio longitudinal retrospectivo de antes y después de 1 sesión de con láser para remoción de tatuajes, donde se determinaron parámetros del tratamiento, aclaramiento y efectos adversos. Resultados: Se evaluaron 35 pacientes para un total de 98 sesiones, fototipo de piel II y IV. Equipos utilizados laser Q-Switch Nd Yag 1064 (83.3%), láser Q-Switch Nd YAG 532(11.3%) y laser Q-Switch Rubí (4.1%). El aclaramiento posterior a la sesión de láser fue evaluado por dos evaluadores independientes, mostrando concordancia significativa (Kappa de 0.615, p<0.001), con aclaración en un 96% de los tatuajes después de la sesión de láser. (p< 0.001). Se encontraron cambios significativos entre la densidad de energía aplicada y las categorías de aclaramiento de la escala de 0 a 3, siendo a mayor densidad mayor el nivel de aclaramiento (p= 0.05). No se encontró asociación significativa entre el número de pases y el aclaramiento del tatuaje. Los efectos adversos fueron del 5.4%. Cicatriz 2%, hiperpigmentación 2% y hipopigmentación 1%. Conclusión: Posterior a una sesión de remoción de tatuajes con láser Q-Switch hay un aclaramiento significativo en un 96% asociado con la densidad de energía, a mayor densidad de energía mayor el nivel de aclaramiento y no al número de pases realizados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foams are cellular structures, produced by gas bubbles formed during the polyurethane polymerization mixture. Flexible PU foams meet the following two criteria: have a limited resistance to an applied load, being both permeable to air and reversibly deformable. There are two main types of flexible foams, hot and cold cure foams differing in composition and processing temperatures. The hot cure foams are widely applied and represent the main composition of actual foams, while cold cure foams present several processing and property advantages, e.g, faster demoulding time, better humid aging properties and more versatility, as hardness variation with index changes are greater than with hot cure foams. The processing of cold cure foams also is attractive due to the low energy consumption (mould temperature from 30 degrees to 65 degrees C) comparatively to hot cure foams (mould temperature from 30 degrees to 250 degrees C). Another advantage is the high variety of soft materials for low temperature processing moulds. Cold cure foams are diphenylmethane diisocyanate (MDI) based while hot cure foams are toluene diisocyanate (TDI) based. This study is concerned with Viscoelastic flexible foams MDI based for medical applications. Differential Scanning Calorimetry (DSC) was used to characterize the cure kinetics and Dynamical Mechanical Analisys to collect mechanical data. The data obtained from these two experimental procedures were analyzed and associated to establish processing/properties/operation conditions relationships. These maps for the selection of optimized processing/properties/operation conditions are important to achieve better final part properties at lower costs and lead times.