902 resultados para load curve
Resumo:
In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.
Resumo:
Aim: To trace a reference curve for motor development from birth up to 12 months of corrected chronological age in infants born preterm and low birth weight. Methods: This is a cross-sectional study with a sample of 308 preterm infants (53% boys) weighing < 2500 g at birth. The Alberta Infant Motor Scale (AIMS) was used for motor development assessment. Results: Comparing the motor performance of preterm infants with infants from a standardized sample on the AIMS, it was found that, except for the age group of the newborn, preterm infants showed lower motor development scores in comparison with the AIMS normative sample in all age groups between 1 and 12 months. The curve of motor development showed a continuous increase in the number of motor skills of preterm infants during their first 12 months of age. However, the average of motor acquisitions of preterm infants showed a nonlinear pattern with a standard indicator of stabilization between 8 and 10 months of age. Conclusion: Preterm infants, 1-12 months of age, showed motor development AIMS scores lower than the standards established in the normative sample. The findings may contribute as norm-reference for assessing the motor development of preterm infants in follow-up programmes in developing countries.
Resumo:
The objective of this study was to evaluate the effect of the ion exchange treatment on the R-curve behavior of a leucite-reinforced dental porcelain, testing the hypothesis that the ion exchange is able to improve the R-curve behavior of the porcelain studied. Porcelain disks were sintered, finely polished, and submitted to an ion exchange treatment with a KNO(3) paste. The R-curve behavior was assessed by fracturing the specimens in a biaxial flexure design after making Vickers indentations in the center of the polished surface with loads of 1.8, 3.1, 4.9, 9.8, 31.4, and 49.0 N. The results showed that the ion exchange process resulted in significant improvements in terms of fracture toughness and flexural strength as compared to the untreated material. Nevertheless, the rising R-curve behavior previously observed in the control group disappeared after the ion exchange treatment, i.e., fracture toughness did not increase with the increase in crack size for the treated group.
Resumo:
Objectives. To assess the elastic modulus (EM), volumetric shrinkage (VS), and polymerization shrinkage stress (PSS) of experimental highly filled nanohybrid composites as a function of matrix composition, filler distribution, and density. Methods. One regular viscosity nanohybrid composite (Grandio, VOCO, Germany) and one flowable nanohybrid composite (Grandio Flow, VOCO) were tested as references along with six highly filled experimental nanohybrid composites (four Bis-GMA-based, one UDMA-based, and one Ormocer (R) -based). The experimental composites varied in filler size and density. EM values were obtained from the ""three-point bending"" load-displacement curve. VS was calculated with Archimedes` buoyancy principle. PSS was determined in 1-mm thick specimens placed between two (poly) methyl methacrylate rods (empty set = 6 mm) attached to an universal testing machine. Data were analyzed using oneway ANOVA, Tukey`s test (alpha = 0.05), and linear regression analyses. Results. The flowable composite exhibited the highest VS and PSS but lowest EM. The PSS was significantly lower with Ormocer. The EM was significantly higher among experimental composites with highest filler levels. No significant differences were found between all other experimental composites regarding VS and PSS. Filler density and size did not influence EM, VS, or PSS. Significance. Neither the filler configuration nor matrix composition in the investigated materials significantly influenced composite shrinkage and mechanical properties. The highest filled experimental composite seemed to increase EM by keeping VS and PSS low; however, matrix composition seemed to be the determinant factor for shrinkage and stress development. The Ormocer, with reduced PSS, deserves further investigation. Filler size and density did not influence the tested parameters. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after ther-mal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm(2)) and resin blocks (Filtek 2250) were built incrementally: Half of the sample was stored in distilled water (37 C, 24 hours) and submitted to thermal (1,000; 5 degrees-55 degrees C) and mechanical cycles (500,000; 10kgf) [TML]. The other half was stored in distilled water (72 hours). The teeth were then sectioned to obtain sticks (0.8 mm(2)) to be tested under tensile mode (1.0 mm/minute). The fracture mode was analyzed at 400x. The BS from all sticks from the same tooth was averaged for statistical purposes. The data was analyzed by three-way ANOVA. The x(2) test was used (p<0.05) to compare the frequency of pre-testing failure specimens. Higher BS values were observed for SBMP regardless of the ADL. The TML reduced the BS values irrespective of the adhesive employed and the ADL. A higher frequency of pre-testing failure specimens was observed for the cycled groups. A thicker adhesive layer, acting as an intermediate flexible layer, did not min-imize the damage caused by thermal/mechanical load cycling for a three-step etch-and-rinse and two-step self-etch system.
Resumo:
Introduction: In this study, we evaluated the influence of intrusion mechanics with accentuated and reversed curve of Spee on root resorption of the maxillary and mandibular incisors. Methods: A sample of 60 patients with Class I and Class II Division 1 malocclusions having nonextraction treatment was divided into 2 groups with the following characteristics: group 1 comprised 30 deepbite patients, treated with accentuated and reversed curve of Spee intrusion mechanics, with an initial mean age of 12.8 +/- 1.23 years (range, 10.01-15.32 years), and group 2 comprised 30 patients with normal overbite treated without intrusion mechanics, with an initial mean age of 12.87 +/- 1.43 years ( range, 10.02-15.36 years). Pretreatment and posttreatment periapical radiographs were used to evaluate root resorption. The groups were compared by using the Mann-Whitney U test. Correlation between root resorption and tooth movement was investigated with the Spearman correlation coefficient. Results: The deepbite group treated with accentuated and reversed curve of Spee had statistically greater root resorption ( 1.87) than the normal overbite group ( 1.54), at P=.017. Changes in overbite and vertical displacements of the maxillary central incisor apices had significant correlations to root resorption ( r = 0.30, P =.019; r = 0.27, P =.037, respectively). Conclusions: Accentuating and reversing the curve of Spee in the archwires to correct deep overbite causes more root resorption than nonintrusive mechanics.
Resumo:
In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.
Resumo:
Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved
Resumo:
Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.
Resumo:
This paper proposed a novel model for short term load forecast in the competitive electricity market. The prior electricity demand data are treated as time series. The forecast model is based on wavelet multi-resolution decomposition by autocorrelation shell representation and neural networks (multilayer perceptrons, or MLPs) modeling of wavelet coefficients. To minimize the influence of noisy low level coefficients, we applied the practical Bayesian method Automatic Relevance Determination (ARD) model to choose the size of MLPs, which are then trained to provide forecasts. The individual wavelet domain forecasts are recombined to form the accurate overall forecast. The proposed method is tested using Queensland electricity demand data from the Australian National Electricity Market. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Primary infection with the human herpesvirus, Epstein-Barr virus (EBV), may result in subclinical seroconversion or may appear as infectious mononucleosis (IM), a lymphoproliferative disease of variable severity. Why primary infection manifests differently between patients is unknown, and, given the difficulties in identifying donors undergoing silent seroconversion, little information has been reported. However, a longstanding assumption has been held that IM represents an exaggerated form of the virologic and immunologic events of asymptomatic infection. T-cell receptor (TCR) repertoires of a unique cohort of subclinically infected patients undergoing silent infection were studied, and the results highlight a fundamental difference between the 2 forms of infection. In contrast to the massive T-cell expansions mobilized during the acute symptomatic phase of IM, asymptomatic donors largely maintain homeostatic T-cell control and peripheral blood repertoire diversity. This disparity cannot simply be linked to severity or spread of the infection because high levels of EBV DNA were found in the blood from both types of acute infection. The results suggest that large expansions of T cells within the blood during IM may not always be associated with the control of primary EBV infection and that they may represent an overreaction that exacerbates disease. (C) 2001 by The American Society of Hematology.
Resumo:
Economic globalisation is seen by many as a driving force for global economic growth. Yet opinion is divided about the benefits of this process, as highlighted by the WTO meeting in Seattle in late 1999. Proponents of economic globalisation view it as a positive force for environmental improvement and as a major factor increasing the likelihood of sustainable development through its likely boost to global investment. These proponents mostly appeal to analysis based on the environmental Kuznets curve (EKC) to support their views about environmental improvement. But EKC-analysis has significant deficiencies. Furthermore, it is impossible to be confident that the process of economic globalisation will result in sustainable development, if 'weak conditions' only are satisfied. 'Strong conditions' probably need to be satisfied to achieve sustainable development, and given current global institutional arrangements, these are likely to be violated by the economic globalisation process. Global political action seems to be needed-to avert a deterioration in the global environment and to prevent unsustainability of development. This exposition demonstrates the limitations of EKC-analysis, identifies positive and negative effects of economic globalisation on pollution levels, and highlights connections between globalisation and the debate about whether strong or weak conditions are required for sustainable development. The article concludes with a short discussion of the position of WTO in relation to trade and the environment and the seemingly de facto endorsement of WTO of weak conditions for sustainable development. It suggests that WTO's relative neglect of environmental concerns is no longer politically tenable and needs to be reassessed in the light of recent developments in economic analysis. The skew of economic growth, e.g. in favour of developing countries, is shown to be extremely important from a global environmental perspective. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
This paper discusses the design and characterisation of a short, and hence portable impact load cell for in-situ quantification of ore breakage properties under impact loading conditions. Much literature has been published in the past two decades about impact load cells for ore breakage testing. It has been conclusively shown that such machines yield significant quantitative energy-fragmentation information about industrial ores. However, documented load cells are all laboratory systems that are not adapted for in-situ testing due to their dimensions and operating requirements. The authors report on a new portable impact load cell designed specifically for in-situ testing. The load cell is 1.5 m in height and weighs 30 kg. Its physical and operating characteristics are detailed in the paper. This includes physical dimensions, calibration and signal deconvolution. Emphasis is placed on the deconvolution issue, which is significant for such a short load cell. Finally, it is conclusively shown that the short load cell is quantitatively as accurate as its larger laboratory analogues. (C) 2062 Elsevier Science B.V. All rights reserved.