986 resultados para lead mines
Resumo:
Project: Serum samples may not be appropriate to assess lead (Pb) concentrations because they may contain artificially higher Pb concentrations compared with those measured in plasma samples. Here, we compared Pb concentrations in serum versus heparin plasma separated from blood collected with or without vacuum. We have also examined the effects of sample standing time on Pb concentrations measured in serum, heparin plasma, and EDTA plasma. Procedure: We studied plasma and serum samples from twelve healthy subjects. Blood samples were collected via venous drainage phlebotomy with and without vacuum into trace metal free tubes containing no anticoagulants (serum), or lithium heparin, or EDTA (to obtain plasma). Variable sample standing times (0, 5, and 30 min) prior to centrifugation were allowed. Plasma and serum Pb and iron concentrations were determined by inductively coupled plasma mass spectrometry. Plasma and serum cell-free hemoglobin concentrations were measured. Results: Pb concentrations in serum and in heparin plasma from blood samples collected with or without vacuum were similar and not associated with significant changes in iron or hemoglobin concentrations. The sample standing time (up to 30 min) did not affect Pb concentrations in serum or in heparin plasma, which were approximately 50% lower than those found in EDTA plasma. Conclusions: Serum or heparin plasma separated from blood samples collected via venous phlebotomy with or without vacuum are appropriate medium to assess Pb concentrations, independently of the sample standing time. (C) 2010 Elsevier GmbH. All rights reserved.
Resumo:
Aim: Our aim was to test: the hypothesis that co-exposure to lead and fluoride alter the severity of enamel fluorosis. Materials and methods: Wistar rats were allocated in four groups: control, and 3 groups that received water containing 100 ppm of fluoride (F), 30 ppm of lead (Pb), or 100 ppm of F and 30 ppm of Pb (F + Pb) from the beginning of gestation. Enamel analysis and F and Pb determinations in enamel, dentine, and bone were performed in 81-day-old animals. Fluorosis was quantified using a new fluorosis index based on the identification of incisor enamel defects (white bands and white islets, representing hypomineralization, and cavities) weighted according to their severity and quantity. Hypomineralization was validated histopathologically by polarizing microscopy and microradiography. Scores were given by two blinded calibrated examiners (intra and interexaminer kappa values were 0.8 and 0.86, respectively). Results: The control and the Pb groups presented normal enamel. The F + Pb group presented more severe enamel defects compared with the F group (P < 0.0001). Conclusions: This study shows that lead exacerbates dental fluorosis in rodents, suggesting that co-exposure to lead may affect the degree of fluorosis. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The adverse effects of environmental lead exposure on the mental development of young children are well established. There is no safe level of blood lead below which children are not affected. Recent research expands our understanding of the impact of lead exposure continuing into later childhood, as well as its effects on children's behaviour. However, social and other environmental factors also contribute to variance in measures of developmental and behavioural outcomes. Lead is associated with only modest effects on children's development, but is a potentially modifiable risk factor. As environmental exposure to lead declines for the whole population, continued specific attention is needed for children living in industrial areas.
Resumo:
Cigarette smoke is a significant source of cadmium, lead, and toxic elements, which are absorbed into the human organism. In this context, the aim of this study was to investigate in vitro the presence of toxic elements, cadmium, and lead deriving from cigarette smoke in the resin composite, dentine, and dental enamel. Eight cylindrical specimens were fabricated from resin composite, bovine enamel, and root dentin fragments that were wet ground and polished with abrasive paper to obtain sections with 6-mm diameter and 2-mm thickness. All specimens were exposed to the smoke of 10 cigarettes/day during 8 days. After the simulation of the cigarette smoke, the specimens were examined with scanning electron microscopy (SEM) and the energy-dispersive X-ray analysis. In the photomicrographic analysis in SEM, no morphological alterations were found; however, the microanalysis identified the presence of cadmium, arsenic, and lead in the different specimens. These findings suggest that the deposition of these elements derived from cigarette smoke could be favored by dental structures and resin composite. Microsc. Res. Tech. 74:287-291, 2011. (C) 2010 Wiley-Liss, Inc.
Resumo:
A quartz crystal microbalance modified by the attachment of silica particles derivatized with the aminopolycarboxylate ligand N-[(3-trimethoxysilyl)propyl]ethylenediamine-N,N',N'-triacetic acid has been employed to assess conditions under which mercury (II), lead (II), and silver (I) nitrates may be separated in aqueous solution. The separation protocol, which involved removal of Hg(II), as [HgI4](2-), and Pb(II) with H+ was successfully applied to a batchwise separation of the 3 metal ions.
Resumo:
The present research investigated attentional blink startle modulation at lead intervals of 60, 240 and 3500 ms. Letters printed in Gothic or standard fonts, which differed in rated interest, but not valence, served as lead stimuli. Experiment I established that identifying letters as vowels/consonants took longer than reading the letters and that performance in both tasks was slower if letters were printed in Gothic font. In Experiment 2, acoustic blink eliciting stimuli were presented 60, 240 and 3500 ms after onset of the letters in Gothic and in standard font and during intertrial intervals. Half the participants (Group Task) were asked to identify the letters as vowels/consonants whereas the others (Group No-Task) did not perform a task. Relative to control responses, blinks during letters were facilitated at 60 and 3500 ms lead intervals and inhibited at the 240 ms lead interval for both conditions in Group Task. Differences in blink modulation across lead intervals were found in Group No-Task only during Gothic letters with blinks at the 3500 ms lead interval facilitated relative to control blinks. The present results confirm previous findings indicating that attentional processes can modulate startle at very short lead intervals. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The ventilation and cooling of deep, hot mines present particular problems in Australia as a consequence of the surface climate, the size of the underground voids, the degree of mechanization and the cost of power in remote areas. A preliminary investigation of the effects of controlled partial recirculation of air was conducted in Mount Isa Mines' Deep Copper section. Gas and dust concentrations were measured in the exhaust air of the major working section to assess the potential for recirculating exhaust air to the intake airways to reduce the cost of providing an acceptable working environment in the deep parts of the mine. Studies were undertaken of airborne dust deposition in vertical airways and the efficiency of usage of the ventilation air in diluting contaminants. It was established that 45% of the respirable dust was deposited in a 130-m vertical raise and 60% of the air supplied to the section could be reused or recirculated. The first major field trial of a controlled partial recirculation system in Australia was undertaken in the light of these results and demonstrated excellent potential for significant reduction in ventilation costs. Gas and dust contaminant levels were well below the threshold limit values during the trial. It is concluded that controlled partial recirculation can be a practical, effective and safe aid to normal ventilation practice in Australian deep, hot mines.
Resumo:
A numerical modelling strategy has been developed in order to quantify the magnitude of induced stresses at the boundaries of production level and undercut level drifts for various in situ stress environments and undercut scenarios. The results of the stress modelling were in line with qualitative experiential guidelines and a limited number of induced stress measurements documented from caving sites. A number of stress charts were developed which quantify the maximum boundary stresses in drift roofs for varying in situ stress regimes, depths and undercut scenarios. This enabled many of the experiential guidelines to be quantified and bounded. A limited number of case histories of support and support performance in cave mine drifts were compared to support recommendations using the NGI classification system, The stress charts were used to estimate the Stress Reduction Factor for this system. The back-analyses suggested that the NGI classification system might be able to give preliminary estimates of support requirements in caving mines with modifications relating to rock bolt length and the support of production level intersections. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Two experiments investigated the effects of the sensory modality of the lead and of the blink-eliciting stimulus during lead stimulus modality change on blink modulation at lead intervals of 2500 and 3500 ins. Participants were presented with acoustic, visual, or tactile change stimuli after habituation training with lead stimuli from the same or a different sensory modality. In Experiment 1, latency and magnitude of the acoustic blink were facilitated during a change to acoustic or visual lead stimuli, but not during a change to tactile lead stimuli. After habituation to acoustic lead stimuli, blink magnitude was smaller during tactile change stimuli than during habituation stimuli. The latter finding was replicated in Experiment 2 in which blink was elicited by electrical stimulation of the trigeminal nerve. The consistency of the findings across different combinations of lead stimulus and blink-eliciting stimulus modalities does not support a modality-specific account of attentional blink modulation. Rather, blink modulation during generalized orienting reflects modality non-specific processes, although modulation may not always be found during tactile lead stimuli. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
This paper presents an analysis of personal respirable coal dust measurements recorded by the Joint Coal Board in the underground longwall mines of New South Wales from 1985 to 1999. A description of the longwall mining process is given. In the study, 11 829 measurements from 33 mines were analysed and the results given for each occupation, for seven occupational groups, for individual de-identified mines and for each year of study. The mean respirable coal dust concentration for all jobs was 1.51 mg/m(3) (SD 1.08 mg/m(3)). Only 6.9% of the measurements exceeded the Australian exposure standard of 3 mg/m(3). Published exposure-response relationships were used to predict the prevalence of progressive massive fibrosis and the mean loss of FEV1, after a working lifetime (40 years) of exposure to the mean observed concentration of 1.5 mg/m(3). Prevalences of 1.3 and 2.9% were predicted, based on data from the UK and the USA, respectively. The mean loss of FEV1 was estimated to be 73.7 ml.
Resumo:
Experimental studies on phase equilibria and liquidus in the multicomponent system PbO-ZnO-CaO-SiO2-FeO-Fe2O3 in air have been conducted over the temperature range between 1323 K (1050 degreesC) and 1623 K (1350 degreesC) to characterize the phase relations of the complex slag systems encountered in lead and zinc blast furnace sinters. The liquidus in two pseudoternary sections ZnO-Fe2O3-(PbO + CaO + SiO2) with the CaO/SiO2 weight ratio of 0.933 and PbO/(CaO + SiO2) weight ratios of 2.0 and 3.2 have been constructed.
Resumo:
Chronic lead exposure induces hypertension in humans and animals, affecting endothelial function. However, studies concerning acute cardiovascular effects are lacking. We investigated the effects of acute administration of a high concentration of lead acetate (100 µΜ) on the pressor response to phenylephrine (PHE) in the tail vascular bed of male Wistar rats. Animals were anesthetized with sodium pentobarbital and heparinized. The tail artery was dissected and cannulated for drug infusion and mean perfusion pressure measurements. Endothelium and vascular smooth muscle relaxation were tested with acetylcholine (5 µg/100 µL) and sodium nitroprusside (0.1 µg/100 µL), respectively, in arteries precontracted with 0.1 µM PHE. Concentration-response curves to PHE (0.001-300 µg/100 µL) were constructed before and after perfusion for 1 h with 100 µΜ lead acetate. In the presence of endothelium (E+), lead acetate increased maximal response (Emax) (control: 364.4 ± 36, Pb2+: 480.0 ± 27 mmHg; P < 0.05) and the sensitivity (pD2; control: 1.98 ± 0.07, 2.38 ± 0.14 log mM) to PHE. In the absence of endothelium (E-) lead had no effect but increased baseline perfusion pressure (E+: 79.5 ± 2.4, E-: 118 ± 2.2 mmHg; P < 0.05). To investigate the underlying mechanisms, this protocol was repeated after treatment with 100 µM L-NAME, 10 µM indomethacin and 1 µM tempol in the presence of lead. Lead actions on Emax and pD2 were abolished in the presence of indomethacin, and partially abolished with L-NAME and tempol. Results suggest that acute lead administration affects the endothelium, releasing cyclooxygenase-derived vasoconstrictors and involving reactive oxygen species.
Resumo:
Lead (Pb2+) poisoning causes hypertension, but little is known regarding its acute effects on cardiac contractility. To evaluate these effects, force was measured in right ventricular strips that were contracting isometrically in 45 male Wistar rats (250-300 g) before and after the addition of increasing concentrations of lead acetate (3, 7, 10, 30, 70, 100, and 300 µM) to the bath. Changes in rate of stimulation (0.1-1.5 Hz), relative potentiation after pauses of 15, 30, and 60 s, effect of Ca2+ concentration (0.62, 1.25, and 2.5 mM), and the effect of isoproterenol (20 ng/mL) were determined before and after the addition of 100 µM Pb2+. Effects on contractile proteins were evaluated after caffeine treatment using tetanic stimulation (10 Hz) and measuring the activity of the myosin ATPase. Pb2+ produced concentration-dependent force reduction, significant at concentrations greater than 30 µM. The force developed in response to increasing rates of stimulation became smaller at 0.5 and 0.8 Hz. Relative potentiation increased after 100 µM Pb2+ treatment. Extracellular Ca2+ increment and isoproterenol administration increased force development but after 100 µM Pb2+ treatment the force was significantly reduced suggesting an effect of the metal on the sarcolemmal Ca2+ influx. Concentration of 100 µM Pb2+ also reduced the peak and plateau force of tetanic contractions and reduced the activity of the myosin ATPase. Results showed that acute Pb2+ administration, although not affecting the sarcoplasmic reticulum activity, produces a concentration-dependent negative inotropic effect and reduces myosin ATPase activity. Results suggest that acute lead administration reduced myocardial contractility by reducing sarcolemmal calcium influx and the myosin ATPase activity. These results also suggest that lead exposure is hazardous and has toxicological consequences affecting cardiac muscle.
Resumo:
Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.