996 resultados para laser model


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a double colour laser scanned photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the colour detection process are analysed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a Double Color Laser Scanned Photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the color detection process are analyzed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present work was to investigate the wetting behaviour of biomedical grade Ti-6Al-4V alloy surfaces textured by a femtosecond laser treatment. The material was treated in ambient atmosphere using an Yb: KYW chirped-pulse-regenerative amplification laser with a wavelength of 1030 nm and a pulse duration of 500 fs. Four main types of surface textures were obtained depending on the processing parameters and laser treatment method. These textures consist of: (1) nanoscale laser-induced periodic surface structures (LIPSS); (2) nanopillars; (3) a bimodal roughness distribution texture formed of LIPSS overlapping microcolumns; (4) a complex texture formed of LIPSS overlapping microcolumns with a periodic variation of the columns size in the laser scanning direction. The wettability of the surfaces was evaluated by the sessile drop method using distilled-deionized (DD) water and Hank's balanced salt solution (HBSS) as testing liquids. The laser treated surfaces present a hydrophilic behaviour as well as a high affinity for the saline solution, with equilibrium contact angles in the ranges 24.1-76.2. for DD water and 8.4-61.8. for HBSS. The wetting behaviour is anisotropic, reflecting the anisotropy of the surface textures. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To determine self-consistently the time evolution of particle size and their number density in situ multi-angle polarization-sensitive laser light scattering was used. Cross-polarization intensities (incident and scattered light intensities with opposite polarization) measured at 135 degrees and ex situ transmission electronic microscopy analysis demonstrate the existence of nonspherical agglomerates during the early phase of agglomeration. Later in the particle time development both techniques reveal spherical particles again. The presence of strong cross-polarization intensities is accompanied by low-frequency instabilities detected on the scattered light intensities and plasma emission. It is found that the particle radius and particle number density during the agglomeration phase can be well described by the Brownian free molecule coagulation model. Application of this neutral particle coagulation model is justified by calculation of the particle charge whereby it is shown that particles of a few tens of nanometer can be considered as neutral under our experimental conditions. The measured particle dispersion can be well described by a Brownian free molecule coagulation model including a log-normal particle size distribution. (C) 1996 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Retinal imaging with a confocal scaning laser Ophthalmoscope (cSLO) involves scanning a small laser beam over the retina and constructing an image from the reflected light. By applying the confocal principle, tomographic images can be produced by measuring a sequence of slices at different depths. However, the thickness of such slices, when compared with the retinal thickness, is too large to give useful 3D retinal images, if no processing is done. In this work, a prototype cSLO was modified in terms hardware and software to give the ability of doing the tomographic measurements with the maximum theoretical axial resolution possible. A model eye was built to test the performance of the system. A novel algorithm has been developed which fits a double Gaussian curve to the axial intensity profiles generated from a stack of images slices. The underlying assumption is that the laser light has mainly been reflected by two structures in the retina, the internal limiting membrane and the retinal pigment epithelium. From the fitted curve topographic images and novel thickness images of the retina can be generated. Deconvolution algorithms have also been developed to improve the axial resolution of the system, using a theoretically predicted cSLO point spread function. The technique was evaluated using measurements made on a model eye, four normal eyes and seven eyes containing retinal pathology. The reproducibility, accuracy and physiological measurements obtained, were compared with available published data, and showed good agreement. The difference in the measurements when using a double rather than a single Gaussian model was also analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, Ag:SiC nanocermets were prepared via rapid thermal annealing (RTA) of pulsed laser-deposited SiC/Ag/SiC trilayers grown on Si substrate. Atomic force microscope images show that silver nanoparticles (Ag NPs) are formed after RTA, and the size of NPs increases with increasing Ag deposition time (t Ag). Sharp dip observed in the reflectance spectra confirmed the existence of Ag surface plasmons (SPs). The infrared transmission spectra showed an intense and broad absorption band around 780–800 cm−1 that can be assigned to Si-C stretching vibration mode. Influence of t Ag on the spectral characteristics of SP-enhanced photoluminescence (PL) and electrical properties of silicon carbide (SiC) films has been investigated. The maximum PL enhancement by 5.5 times for Ag:SiC nanocermets is achieved when t Ag ≈ 50 s. This enhancement is due to the strong resonant coupling between SiC and the SP oscillations of the Ag NPs. Presence of Ag NPs in SiC also induces a forming-free resistive switching with switching ratio of 2 × 10−2. The analysis of I–V curves demonstrates that the trap-controlled space-charge-limited conduction with filamentary model is the governing mechanism for the resistive switching in nanocerment thin films.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Curcumin and caffeine (used as lipophilic and hydrophilic model compounds, respectively) were successfully encapsulated in lactoferrin-glycomacropeptide (Lf-GMP) nanohydrogels by thermal gelation showing high encapsulation efficiencies (>90 %). FTIR spectroscopy confirmed the encapsulation of bioactive compounds in Lf-GMP nanohydrogels and revealed that according to the encapsulated compound different interactions occur with the nanohydrogel matrix. The successful encapsulation of bioactive compounds in Lf-GMP nanohydrogels was also confirmed by fluorescence measurements and confocal laser scanning microscopy. TEM images showed that loaded nanohydrogels maintain their spherical shape with sizes of 112 and 126 nm for curcumin and caffeine encapsulated in Lf-GMP nanohydrogels, respectively; in both cases a polydispersity of 0.2 was obtained. The release mechanisms of bioactive compounds through Lf-GMP nanohydrogels were evaluated at pH 2 and pH 7, by fitting the Linear Superimposition Model to the experimental data. The bioactive compounds release was found to be pH-dependent: at pH 2, relaxation is the governing phenomenon for curcumin and caffeine compounds and at pH 7 Ficks diffusion is the main mechanism of caffeine release while curcumin was not released through Lf-GMP nanohydrogels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El láser de baja y media energía y la magnetoterapia son utilizados en desórdenes osteomioarticulares por sus efectos analgésico, antiinflamatorio y trófico, entre los más destacados. Sin embargo, son insuficientes las investigaciones sobre su mecanismo de acción y antecedentes científicos que avalen sus efectos. Es por ello, que la determinación de acontecimientos celulares y moleculares que ocurren durante la interacción de estos tipos de energía con el sistema muscular, sería relevante para el conocimiento y optimización de tales terapias en las ciencias biomédicas. En las miopatías inflamatorias idiopáticas, se encuentra afectada la estructura, morfología y bioquímica del tejido muscular. La energía que éste requiere para el normal funcionamiento es generada en la mitocondria. Esta organela también es la responsable de la generación de especies oxidantes provocando estrés oxidativo y el inicio de los procesos de apoptosis. Por lo antes dicho, consideramos que la determinación de los biomarcadores inflamatorios asociados a estrés oxidativo, realizando el análisis histomorfométrico ultraestructural y valorando la actividad de los complejos enzimáticos mitocondriales, permitiría una evaluación de la acción terapéutica del láser y la magnetoterapia en un modelo experimental de miopatía. Para ello se propone evaluar el efecto de la magnetoterapia y del láser de baja energía (He-Ne y As.Ga) en miopatía experimental determinando indicadores inflamatorios asociados a estrés oxidativo, análisis histomorfométrico y valoración de la actividad enzimática mitocondrial. Específicamente: -Determinar indicadores inflamatorios y de estrés oxidativo: Oxido Nítrico, Grupos carbonilos, L-citrulina, Fibrinógeno, Superóxido dismutasa, Glutation peroxidasa y Catalasa por espectrofotometría. -Identificar los cambios anatomopatológicos del músculo esquelético por microscopía óptica (MO): cuantificación del infiltrado inflamatorio; MO de alta resolución (MOAR) y por microscopía electrónica: histomorfometría de la ultraestructura miofibrilar y mitocondrial. -Valorar las actividades enzimáticas de la citrato sintasa y de los complejos: I (NADH-ubiquinona reductasa), II (succinato-ubiquinona-reductasa) III (ubiquinona-citocromo c-reductasa) y IV (citocromo c-oxidasa); en mitocondrias de tejido muscular por espectrofotometría. -Evaluar la actividad apoptótica en las fibras musculares de los diferentes grupos por ténica de T.U.N.E.L. Las mediciones mitocondriales (por ME) y de infiltrado inflamatorio (por MO) se realizarán en un total de 5 fotos de aumentos similares en forma aleatoria por grupo estudiado (n=10). Los cambios estructurales observados se analizarán en el programa Axiovision 4.8, para cuantificar el área total ocupada, número total y grado de alteración de las mitocondrias y el porcentaje de infiltrado inflamatorio determinando el grado de inflamación. Los resultados de los datos cuantitativos se analizarán aplicando ANAVA (test de Fisher para comparaciones múltiples); y para los datos categóricos se utilizará Chi cuadrado (test de Pearson), estableciéndose un nivel de significación de p < 0.05 para todos los casos. Importancia del Proyecto: La salud y el bienestar del hombre son los logros perseguidos por las ciencias de la salud. La obtención de terapias curativas o paliativas con un mínimo de efectos colaterales para el enfermo se incluye en estos logros. Por esto y todo lo anteriormente expuesto es que consideramos de gran importancia poder esclarecer desde las ciencias básicas los efectos celulares y moleculares en modelos experimentales la acción de la terapia con láser y magnetoterapia para una aplicación clínica con base científica en todas las áreas de las Ciencias Médicas. In the idiopathic inflammatory myopathies, is affected the structure, morphology and biochemistry of muscle tissue. The mitochondria is responsible for the generation of oxidizing species leading to oxidative stress and the beginning of the process of apoptosis. As said before, we consider the determination of inflammatory biomarkers related to oxidative stress, by ultrastructural morphometric analysis and assessing the activity of mitochondrial enzyme complexes, permit an evaluation of the therapeutic action of laser and magnetic therapy in an experimental model myopathy. We propose to evaluate the effect of the treatment identifying indicators in experimental inflammatory myopathy associated with oxidative stress, histomorphometric analysis and assessment of mitochondrial enzyme activity. Specifically -determining: Nitric oxide, carbonyl groups, L-citrulline, fibrinogen, superoxide dismutase, glutathione peroxidase and catalase by spectrophotometry. -Identify the pathological changes in skeletal muscle by optical microscopy (OM): quantification of the inflammatory infiltrate, OM high resolution (MOAR) and electron microscopy, histomorphometry of myofibrillar and mitochondrial ultrastructure. -Evaluate the enzymatic activity of citrate synthase and complexes: I, II, III and IV in mitochondria muscle tissue by spectrophotometry. -Evaluate apoptotic activity in muscle fibers by TUNEL technique of Mitochondrial measurements and inflammatory infiltration (by OM) was performed in a total of 5 photos of similar increases in random by the study group (n = 10). The structural changes observed are discussed in the program Axiovision 4.8, to quantify number, degree of alteration of mitochondria and the percentage of inflammatory infiltrate determining the degree of inflammation. The results of the quantitative data were analyzed using ANOVA (Fisher test), and categorical data with Chi-square (Pearson test), establishing a significance level of p <0.05.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this project was to develop an arterial aneurysm using either enzymatic or laser degradation of the arterial wall without affecting the viability of the tissue and to cultivate the arteries under pulsatile flow conditions in a vascular bioreactor with a view to investigate the progress of the disease. Characteristics of aneurysms are the degradation of smooth muscle cells, collagen and elastin. Detached smooth muscle cells and degradation of the collagen matrix and elastin fibres were observed in arteries degraded with enzymes elastase and collagenase. Only remnants of the arterial wall were detected after cultivation. This might be a suitable model for late stage aneurysms. Arteries treated with the laser system showed no charring or heat damage of the not dissected area. Collagen matrix, smooth muscle cells and elastin fibres were intact. A clear defined cut was made in a depth of 200 μm and tissue was removed. Following cultivation of these arteries a dilation of the laser-eroded area was observed. This model can mimic atherosclerotic aneurysms, when plaques weaken the tunica media of the blood vessel wall and rupture. Limitations of this study were contamination of the bioreactor system and a low number of cultivations. The aim to generate a living arterial aneurysm in vitro was not achieved. Tissue viability decreased to the level of negative controls after cultivation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Solid tumors are known to have an abnormal vasculature that limits the distribution of chemotherapy. We have recently shown that tumor vessel modulation by low-dose photodynamic therapy (L-PDT) could improve the uptake of macromolecular chemotherapeutic agents such as liposomal doxorubicin (Liporubicin) administered subsequently. However, how this occurs is unknown. Convection, the main mechanism for drug transport between the intravascular and extravascular spaces, is mostly related to interstitial fluid pressure (IFP) and tumor blood flow (TBF). Here, we determined the changes of tumor and surrounding lung IFP and TBF before, during, and after vascular L-PDT. We also evaluated the effect of these changes on the distribution of Liporubicin administered intravenously (IV) in a lung sarcoma metastasis model. MATERIALS AND METHODS: A syngeneic methylcholanthrene-induced sarcoma cell line was implanted subpleurally in the lung of Fischer rats. Tumor/surrounding lung IFP and TBF changes induced by L-PDT were determined using the wick-in-needle technique and laser Doppler flowmetry, respectively. The spatial distribution of Liporubicin in tumor and lung tissues following IV drug administration was then assessed in L-PDT-pretreated animals and controls (no L-PDT) by epifluorescence microscopy. RESULTS: L-PDT significantly decreased tumor but not lung IFP compared to controls (no L-PDT) without affecting TBF. These conditions were associated with a significant improvement in Liporubicin distribution in tumor tissues compared to controls (P < .05). DISCUSSION: L-PDT specifically enhanced convection in blood vessels of tumor but not of normal lung tissue, which was associated with a significant improvement of Liporubicin distribution in tumors compared to controls.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. METHODS: Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. RESULTS: Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. SIGNIFICANCE: Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human schistosomiasis develops extensive and dense fibrosis in portal space, together with congested new blood vessels. This study demonstrates that Calomys callosus infected with Schistosoma mansoni also develops fibrovascular lesions, which are found in intestinal subserosa. Animals were percutaneously infected with 70 cercariae and necropsied at 42, 45, 55, 80, 90 and 160 days after infection. Intestinal sections were stained for brightfield, polarization microscopy, confocal laser scanning, transmission and scanning electron microscopies. Immunohistological analysis was also performed and some nodules were aseptically collected for cell culture. Numerous intestinal nodules, appearing from 55 up to 160 days after infection, were localized at the interface between external muscular layer and intestinal serosa, consisting of fibrovascular tissue forming a shell about central granuloma(s). Intranodular new vessels were derived from the vasculature of the external vascular layer and were positive for laminin, chondroitin-sulfate, smooth muscle alpha-actin and FVIII-RA. Fibroblastic cells and extracellular matrix components (collagens I, III and VI, fibronectin and tenascin) comprised the stroma. Intermixed with the fibroblasts and vessels there were variable number of eosinophils, macrophages and haemorrhagic foci. In conclusion, the nodules constitute an excellent and accessible model to study fibrogenesis and angiogenesis, dependent on S. mansoni eggs. The fibrogenic activity is fibroblastic and not myofibroblastic-dependent. The angiogenesis is so prominent that causes haemorrhagic ascites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Terrestrial laser scanning (TLS) provides high-resolution point clouds of the topography and new TLS instruments with ranges exceeding 300 m or even 1000 m are powerful tools for characterizing and monitoring slope movements. This study focuses on the 35 million m3 Åknes rockslide in Western Norway, which is one of the most investigated and monitored rockslides in the world. The TLS point clouds are used for the structural analysis of the steep, inaccessible main scarp of the rockslide, including an assessment of the discontinuity sets and fold axes. TLS acquisitions in 2006, 2007 and 2008 provide information on 3-D displacements for the entire scanned area and are not restricted like conventional survey instruments to single measurement points. The affine transformation matrix between two TLS acquisitions precisely describes the rockslide displacements and enables their separation into translational components, such as the displacement velocity and direction, and rotational components, like toppling. This study shows the ability of TLS to obtain reliable 3-D displacement information over a large, unstable area. Finally, a possible instability model for the upper part of Åknes rockslide explains the measured translational and rotational displacements by a combination of southward planar sliding along the gneiss foliation, gravitational vertical settlement along the complex, stepped basal sliding surface and northward toppling toward the opened graben structure.