464 resultados para interferometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shot noise through a closed Aharonov-Bohm interferometer carrying a quantum dot in one of its two current paths is investigated. It is found that the shot noise can be modulated by the magnetic flux Phi, the dot level, and the direct tunneling. Due to the interference between the two transmission channels, the Kondo correlation manifests itself in the flux dependence of the shot noise, which exhibits oscillation behavior with a period of Phi(0)/2 (Phi(0) is the flux quantum) for small voltages below the Kondo temperature T-K. At voltages well above T-K or outside the Kondo regime, the shot noise is determined by high-energy Coulomb and hybridization processes, and its Aharonov-Bohm oscillations restore the fundamental period of Phi(0). As a result of its two-particle nature, the shot noise contains higher-order harmonics absent in the current, demonstrating the fact that the noise is more sensitive to the effects of quantum interference than the current.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissipative optomechanics studies the coupling of the motion of an optical element to the decay rate of a cavity. We propose and theoretically explore a realization of this system in the optical domain, using a combined Michelson-Sagnac interferometer, which enables a strong and tunable dissipative coupling. Quantum interference in such a setup results in the suppression of the lower motional sideband, leading to strongly enhanced cooling in the non-sideband-resolved regime. With state-of-the-art parameters, ground-state cooling and low-power quantum-limited position transduction are both possible. The possibility of a strong, tunable dissipative coupling opens up a new route towards observation of such fundamental optomechanical effects as nonlinear dynamics. Beyond optomechanics, the suggested method can be readily transferred to other setups involving nonlinear media, atomic ensembles, or single atoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe and analyse the operation and stabilization of a Mach--Zehnder interferometer, which separates the carrier and the first-order sidebands of a phase-modulated laser field, and which is locked using the H\"ansch--Couillaud method. In addition to the necessary attenuation, our interferometer introduces, via total internal reflection, a significant polarization-dependent phase delay. We employ a general treatment to describe an interferometer with an object which affects the field along one path, and we examine how this phase delay affects the error signal. We discuss the requirements necessary to ensure the lock point remains unchanged when phase modulation is introduced, and we demonstrate and characterize this locking experimentally. Finally, we suggest an extension to this locking strategy using heterodyne detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the dynamics of two interacting bosons repeatedly scattering off a beam-splitter in a free oscillation atom interferometer. Using the interparticle scattering length and the beam-splitter probabilites as our control parameters, we show that even in a simple setup like this a wide range of strongly correlated quantum states can be created. This in particular includes the NOON state, which maximizes the quantum Fisher information and is a foremost state in quantum metrology. DOI: 10.1103/PhysRevA.87.043630

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A correlation interferometer working with a cooperation target operating at 2.2GHz center frequency is presented. This simplified interferometer presented here uses a
lock-in amplifier to significantly increase system sensitivity when used in conjunction with a co-operating target signaling using amplitude modulation. The system is verified by detecting the angular velocity of passing tagged target. Experimental results show detectable range up over 110 meters in a multipath environment using a 10dBm EIRP tag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyse a proposal that we have recently put forward for an interface between matter-wave and optomechanical technologies from the perspective of macroscopic quantumness. In particular, by making use of a measure of macroscopicity in quantum superpositions that is particularly well suited for continuous variables systems, we demonstrate the existence of working points for our interface at which a quantum mechanical superposition of genuinely mesoscopic states is achieved. Our proposal thus holds the potential to affirm itself as a viable atom-to-mechanics transducer of quantum coherences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical add-drop multiplexer (OADM) based on the Mach-Zelauler interferometer (MZI) and the fiber Bragg grating (FBG) is proposed for the first tittle to the authors ' knowledge. In the structure, the Mach-Zehnder interferometer acts as an optical switch. The principle of the OADM is analyzed in this paper. The OADM can add/drop one of the multi-input channels or pass the channel directly by adjusting the difference of the two arms of the interferometer. The channel isolation is more than 20 dB