988 resultados para in situ trapping in graphite furnace


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciência dos Materiais - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for the direct determination of As in sugar by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (end-capped THGA) and longitudinal Zeeman-effect background correction. The thermal behavior of As during the pyrolysis and atomization steps was investigated in sugar solutions containing 0.2% (v/v) HNO3 using Pd, Ni, and a mixture of Pd + Mg as the chemical modifiers. For a 60-muL sugar solution, an aliquot of 8% (m/v) in 0.2% (v/v)HNO3 was dispensed into a pre-heated graphite tube at 70 degreesC. Linear analytical curves were obtained in the 0.25 - 1.50-mug L-1 As range. Using 5 mug Pd and a first pyrolysis step at 600 degreesC assisted by air during 40 s, the formation of a large amount of carbonaceous residue inside the atomizer was avoided. The characteristic mass was calculated as 24 pg As and the lifetime of the graphite tube was around 280 firings. The limit of detection (L.O.D.) based on integrated absorbance was 0.08 mug L-1 (4.8 pg As) and the typical relative standard deviation (n = 12) was 7% for a sugar solution containing 0.5 mug L-1. Recoveries of As added to sugar samples varied from 86 to 98%. The accuracy was checked in the direct analysis of eight sugar samples. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained for acid-digested sugar samples by GFAAS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent reports associating aluminium with several skeletal (osteomalacia) and neurological disorders (encephalopathy and Alzheimer’s disease) in humans suggest that exposure to aluminium may pose a hazard to health. This requires the examination of aluminiumcontent in different foodstuffs. Therefore, an analytical method for the determination of aluminium in fish and fishery products, especially in fishery products packaged in aluminium cans, was developed using graphite furnace atomic absorption spectrometry. Fillets of lean and fatty fish showed aluminium levels lower than 1mg/kg wet weight, muscle of crustacean, molluscan and shellfish had apparently higher aluminium levels (up to 20 mg/kg wet weight). The aluminium content in some aluminum-canned herring was much higher than the content found in herring caught in the North Sea. These results indicate that aluminium is taken up by the herring fillets in aluminium cans, presumably through the slight and slow dissolution of aluminium from the can wall, due to some defects in the protective lacquer layer. A comparison of the aluminium levels measured in canned herring with the average aluminium-intake (normally between 3 and 5 mg/day) or with the provisional tolerable daily intake of 1mg/kg body weight per day (WHO 1989) indicated, that the aluminium content of the edible part of aquatic food does not play a significant role. High consumption of fish fillets does not pose any health risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biological studies and heavy metal (Ni, v, Fe, Pb,Cd) determination in liver, gonad and muscle of Scomberomorus commerson were carried out from Oct 2006 to Sept 2007 in Hormozgan coastal waters. 599 Samples were gutted for reproduction and nutrition studies, fork length and weight were measured to nearest cm and g respectively. Meanwhile 40 samples were also investigated for heavy metal studies. All specimens were collected from two major landing sites (Bandar Lengeh & Bandar Abbas). Minimums & maximum fork length & weight were 29, 128 cm & 235 and 15350 g respectively.Isometric growth was shown according to our study and b was estimated 2.9 (overall), 2.91(male) & 2.89 (female). The average relative gut length was 0.52± 0.007 and it was determined that S. commerson is a carnivorous. More than 99 percent of gut content was different teleost fishes. Gastro somatic index had two peaks in Nov & Jan (before spawning) and with a decreased trend in July, the spawning period. Occurrence of empty stomach was estimated % 65.77. Maximum amount of condition factor was in Dec. Spawning season was started from June. The average of Absolute & relative fecundity (to weight unit) was 1217149±179315 and 178.2±15.58 respectively. Lm50% was estimated 75 cm for females. Sex ratio was 0.97: 1 (male: female). Chi- Square test showed no significant difference (p>0.05). Maximum amount of hepatosomatic index was estimated in March.Metal concentrations were determined using either Flame Atomic Absorption Spectroscopy (for Fe) or Graphite Furnace Atomic Absorption Spectroscopy (for Pb,Cd,Ni and V). The mean concentration (μg/g dry weight)of Pb,Cd,Ni,V and Fe in the liver were 0.0309, 0.0268, 0.0672, 0.0077, 2.5159 in the gonad 0.0440 ,0.0295, 0.1096, 0.0000, 1.4449 and in the muscle 0.0244, 0.0324, 0.0656, 0.0128, 1.6138 respectively. The maximum metal concentrations were below the maximum permissible limits for human consumption recommended by the USEPA, WHO and the UK. The results of Kendall's Tau-b correlation coefficient were as follows: The Liver tissue: There were significant positive linear relationships between accumulation of V, Fe, and Pb with Fork length, Pb and Fe with weight, GSI with Pb, Cd, V and 109 Fe, and a negative linear relationships between HSI with accumulation of V and Fe, Fork length, weight and GSI. The Gonad tissue: There were significant positive linear relationships between GSI with accumulation of Pb, Cd, Fe, Fork length and weight, a negative linear relationship between HSI with Fork length, weight and GSI. The Muscle tissue: There were significant positive linear relationships between accumulations of V, Fe with Fork length and weight factors and as well as GSI with Cd, V, Fe, Pb, Fork length and weight,a negative linear relationship between HSI with Fork length, weight, Cd, Fe and GSI. The results of Mann-Whitney U tests (P≤0.05) show that there were significant differences between summer and autumn from heavy metal contents in the studied tissues point of view. The only exceptions were for Ni in the liver, gonads and muscle and as well as there were significant differences between male and female from heavy metal contents in the studied tissues. The only exceptions were for Pb in muscle, Ni in liver, gonad and muscle, V in muscle, and Cd and Fe in gonads.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aluminium is omnipresent in everyday life and increased exposure is resulting in a burgeoning body burden of this non-essential metal. Personal care products are potential contributors to the body burden of aluminium and recent evidence has linked breast cancer with aluminium-based antiperspirants. We have used graphite furnace atomic absorption spectrometry (GFAAS) to measure the aluminium content in breast biopsies obtained following mastectomies. The aluminium content of breast tissue and breast tissue fat were in the range 4-437 nmol/g dry wt. and 3-192 nmol/g oil, respectively. The aluminium content of breast tissue in the outer regions (axilla and lateral) was significantly higher (P = 0.033) than the inner regions (middle and medial) of the breast. Whether differences in the regional distribution of aluminium in the breast are related to the known higher incidence of tumours in the outer upper quadrant of the breast remains to be ascertained. (c) 2007 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An approach was developed to estimate molecular weight distribution of water-soluble Cu, Fe, Mn and Zn species in Brazil nut, cupuassu seed and coconut pulp by size exclusion chromatography (SEC) coupled on-line to ultra-violet (UV) and off-line to graphite furnace atomic absorption spectrometry (GF-AAS) detectors and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS). SEC-UV analytical signals showed the prevalence of high molecular weight (HMW) species (79-1.7 kDa for Brazil nut, 50-1.7 kDa for coconut pulp, and 34-1.7 kDa for cupuassu seeds). The Brazil nut SEC-UV, GF-AAS and MALDI-TOF mass spectra gave confirmation of the association of the elements with water-soluble compounds. The elemental profiles were associated with fractions of compounds of molecular weight 1.2-16 kDa for Brazil nut, 1.7-13 kDa for coconut pulp, and 1.2-7.6 kDa for cupuassu seeds. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel approach of using a gold disc microelectrode to analyze sweat samples for copper ions by anodic square wave stripping voltammetry (SW stripping voltammetry) is described Sweat was collected from the lower back of four subjects after physical exercise and the sample volume required for the determinations was 100 mu L. Under the optimized conditions the calibration plot was linear over the range 1-100 mu mol L(-1) Cu(II) with a limit of detection of 0 25 mu mol L(-1) The precision was evaluated by carrying out five replicate measurements in a 1 mu mol L(-1) Cu(II) solution and the standard deviation was found to be 1 5% Measurements were performed by inserting the microelectrode into sweat drops and Cu(II) concentrations in the analyzed samples ranged from 09 to 28 mu mol L(-1) Values obtained by the proposed voltammetric method agreed well with those found using graphite furnace atomic absorption spectroscopy (GFAAS) (C) 2010 Elsevier B V All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, cadmium and lead in the muscle, lung, liver and kidney of dolphins (Sotalia guianensis and Stenella clymene) of the Bahia coast in the northwest of Brazil were determined by graphite furnace atomic absorption spectrometry. Samples were digested using a diluted oxidant mixture (HNO(3) + H(2)O(2)) with a microwave heating program performed in five steps. The optimized temperatures and chemical modifier for the pyrolysis and atomization were 700 degrees C, 1400 degrees C and Pd plus Mg for Cd, and 900 degrees C, 1800 degrees C and NH(4)H(2)PO(4) for Pb, respectively. Characteristic masses and limits of detections (n = 20, 3 sigma) for Cd and Pb were 1.6 and 9.0 pg and 0.82 ng g(-1) and 0.50 ng g(-1), respectively. Repeatability ranged from 0.87 to 8.22% for Cd and 4.31 to 8.09% for Pb. The found concentrations presented no statistical differences at the 95% confidence level when compared with the ICP OES methods. Addition and recovery tests were also performed and the results ranged between 87 and 112% for both elements. Samples of cetacean Dolphinidae (S. guianensis and S. clymene) were analyzed, and the higher concentrations ranged from 0.09 to 46.2 mu g g(-1) for Cd and 0.04 to 0.47 mu g g(-1) for Pb in liver, and from 0.133 to 277 mu g g(-1) for Cd in the kidney. (C) 2010 Elsevier By. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The physical and chemical characteristics of peat were assessed through measurement of pH, percentage of organic matter, cationic exchange capacity (CEC), elemental analysis, infrared spectroscopy and quantitative analysis of metals by ICP OES. Despite the material showed to be very acid in view of the percentage of organic matter, its CEC was significant, showing potential for retention of metal ions. This characteristic was exploited by coupling a peat mini-column to a flow system based on the multicommutation approach for the in-line copper concentration prior to flame atomic absorption spectrometric determination. Cu(II) ions were adsorbed at pH 4.5 and eluted with 0.50 mol L(-1) HNO(3). The influence of chemical and hydrodynamic parameters, such as sample pH, buffer concentration, eluent type and concentration, sample flow-rate and preconcentration time were investigated. Under the optimized conditions, a linear response was observed between 16 and 100 mu g L(-1), with a detection limit estimated as 3 mu g L(-1) at the 99.7% confidence level and an enrichment factor of 16. The relative standard deviation was estimated as 3.3% (n = 20). The mini-column was used for at least 100 sampling cycles without significant variation in the analytical response. Recoveries from copper spiked to lake water or groundwater as well as concentrates used in hemodialysis were in the 97.3-111 % range. The results obtained for copper determination in these samples agreed with those achieved by graphite furnace atomic absorption spectrometry (GFAAS) at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-resolution positron annihilation lifetime (PAL) and two-detector coincidence Doppler broadening of annihilation radiation (2D-DBAR) measurements on graphite and its oxide derivatives for defect information, differing in oxidization agents, are reported. Positron measurements were found to be very effective in the investigation of defects in graphite and its derivatives. Positrons are mainly annihilated in vacancy-like defects on the particle surface and in large open-volume holes associated with the interface of graphite and graphite oxide. Different types of defects have been detected for unexfoliated graphite oxide and exfoliated graphene oxide based on 2D-DBAR measurements, namely the vacancy cluster and vacancy-oxygen complexes. It is also interesting to observe that the calculated large open-volume diameter of graphene oxide coincides with the distance between the layers from the XRD investigation, which indicates that the annihilation of the long-lived lifetime component τ3 might take place in the area between the graphene layers; no large open-volume hole has been detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine selenium in samples of feces and of fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The limits of detection (LOD) and quantification (LOQ calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of selenium) were 0.31 mu g 1(-1) and 1.03 mu g 1(-1), respectively, for the standard feces slurries and 0.35 mu g 1(-1) and 1.16 mu g 1(-1), respectively, for the standard feed slurries. The proposed method was applied in studies of bioavailability of selenium in different fish feeds and the results proved consistent with that obtained from samples mineralized by acid digestion using the microwave oven. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)