864 resultados para high velocity power training


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a new dual-gas multi-jet HHG source which can be perfectly controlled via phasematching of the long and short trajectory contributions and is applicable for high average power driver laser systems. © 2011 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas fired generation currently plays an integral support role ensuring security of supply in power systems with high wind power penetrations due to its technical and economic attributes. However, the increase in variable wind power has affected the gas generation output profile and is pushing the boundaries of the design and operating envelope of gas infrastructure. This paper investigates the mutual dependence and interaction between electricity generation and gas systems through the first comprehensive joined-up, multi-vector energy system analysis for Ireland. Key findings reveal the high vulnerability of the Irish power system to outages on the Irish gas system. It has been shown that the economic operation of the power system can be severely impacted by gas infrastructure outages, resulting in an average system marginal price of up to €167/MWh from €67/MWh in the base case. It has also been shown that gas infrastructure outages pose problems for the location of power system reserve provision, with a 150% increase in provision across a power system transmission bottleneck. Wind forecast error was shown to be a significant cause for concern, resulting in large swings in gas demand requiring key gas infrastructure to operate at close to 100% capacity. These findings are thought to increase in prominence as the installation of wind capacity increases towards 2020, placing further stress on both power and gas systems to maintain security of supply.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing installed capacities of wind power in an effort to achieve sustainable power systems for future generations pose problems for system operators. Volatility in generation volumes due to the adoption of stochastic wind power is increasing. Storage has been shown to act as a buffer for these stochastic energy sources, facilitating the integration of renewable energy into a historically inflexible power system. This paper examines peak and off peak benefits realised by installing a short term discharge storage unit in a system with a high penetration of wind power in 2020. A fully representative unit commitment and economic dispatch model is used to analyse two scenarios, one ‘with storage’ and one ‘without storage’. Key findings of this preliminary study show that wind curtailment can be reduced in the storage scenario, with a larger reduction in peak time ramping of gas generators is realised.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We employ Ca II K and Na I D interstellar absorption-line spectroscopy of early-type stars in the Large and Small Magellanic Clouds (LMC, SMC) to investigate the large- and small-scale structure in foreground intermediate- and high-velocity clouds (I/HVCs). Data include FLAMES-GIRAFFE Ca II K observations of 403 stars in four open clusters, plus FEROS or UVES spectra of 156 stars in the LMC and SMC. The FLAMES observations are amongst the most extensive probes to date of Ca II structures on ∼20 arcsec scales in Magellanic I/HVCs. From the FLAMES data within a 0 ∘.∘.∘.5 field of view, the Ca II K equivalent width in the I/HVC components towards three clusters varies by factors of ≥10. There are no detections of molecular gas in absorption at intermediate or high velocities, although molecular absorption is present at LMC and Galactic velocities towards some sightlines. The FEROS/UVES data show Ca II K I/HVC absorption in ∼60 per cent of sightlines. The range in the Ca II/Na I ratio in I/HVCs is from –0.45 to +1.5 dex, similar to previous measurements for I/HVCs. In 10 sightlines we find Ca II/O I ratios in I/HVC gas ranging from 0.2 to 1.5 dex below the solar value, indicating either dust or ionization effects. In nine sightlines I/HVC gas is detected in both H I and Ca II at similar velocities, implying that the two elements form part of the same structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hypothesis: As the anterior and posterior semicircular canals are vital to the regulation of gaze stability, particularly during locomotion or vehicular travel, we tested whether the high velocity vestibulo‐ocular reflex (VOR) of the three ipsilesional semicircular canals elicited by the modified Head Impulse Test would correlate with subjective dizziness or vertigo scores after vestibular neuritis (VN). Background: Recovery following acute VN varies with around half reporting persistent symptoms long after the acute episode. However, an unanswered question is whether chronic symptoms are associated with impairment of the high velocity VOR of the anterior or posterior canals. Methods: Twenty patients who had experienced an acute episode of VN at least three months earlier were included in this study. Participants were assessed with the video head impulse test (vHIT) of all six canals, bithermal caloric irrigation, the Dizziness Handicap Inventory (DHI) and the Vertigo Symptoms Scale short‐form (VSS). Results: Of these 20 patients, 12 felt that they had recovered from the initial episode whereas 8 did not and reported elevated DHI and VSS scores. However, we found no correlation between DHI or VSS scores and the ipsilesional single or combined vHIT gain, vHIT gain asymmetry or caloric paresis. The high velocity VOR was not different between patients who felt they had recovered and patients who felt they had not. Conclusions: Our findings suggest that chronic symptoms of dizziness following VN are not associated with the high velocity VOR of the single or combined ipsilesional horizontal, anterior or posterior semicircular canals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal generation is a vital component of mature and reliable electricity markets. As the share of renewable electricity in such markets grows, so too do the challenges associated with its variability. Proposed solutions to these challenges typically focus on alternatives to primary generation, such as energy storage, demand side management, or increased interconnection. Less attention is given to the demands placed on conventional thermal generation or its potential for increased flexibility. However, for the foreseeable future, conventional plants will have to operate alongside new renewables and have an essential role in accommodating increasing supply-side variability. This paper explores the role that conventional generation has to play in managing variability through the sub-system case study of Northern Ireland, identifying the significance of specific plant characteristics for reliable system operation. Particular attention is given to the challenges of wind ramping and the need to avoid excessive wind curtailment. Potential for conflict is identified with the role for conventional plant in addressing these two challenges. Market specific strategies for using the existing fleet of generation to reduce the impact of renewable resource variability are proposed, and wider lessons from the approach taken are identified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phototherapy improves cellular activation which is an important factor for the treatment of cellulite. The objective of this research was to develop and evaluate the effects of a new (noninvasive and nonpharmacological) clinical procedure to improve body aesthetics: infrared-LED (850 nm) plus treadmill training. Twenty women (25-55 years old) participated in this study. They were separated in two groups: the control group, which carried out only the treadmill training (n = 10), and the LED group, with phototherapy during the treadmill training (n - 10). The training was performed for 45 minutes twice a week over 3 months at intensities between 85% and 90% maximal heart rate (HR(max)). The irradiation parameters were 39 mW/cm(2) and a fluence of 106 J/cm(2). The treatment was evaluated by interpreting body composition parameters, photographs and thermography. This was primarily a treatment for cellulite with a reduction of saddlebag and thigh circumference. At the same time, the treadmill training prevented an increase of body fat, as well as the loss of lean mass. Moreover, thermal images of the temperature modification of the thighs are presented. These positive effects can result in a further improvement of body aesthetics using infrared-LED together with treadmill training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The capacitor test process at ABB Capacitors in Ludvika must be improved to meet future demands for high voltage products. To find a solution to how to improve the test process, an investigation was performed to establish which parts of the process are used and how they operate. Several parts which can improves the process were identified. One of them was selected to be improved in correlation with the subject, mechanical engineering. Four concepts were generated and decision matrixes were used to systematically select the best concept. By improving the process several benefits has been added to the process. More units are able to be tested and lead time is reduced. As the lead time is reduced the cost for each unit is reduced, workers will work less hours for the same amount of tested units, future work to further improve the process is also identified. The selected concept was concept 1, the sway stop concept. This concept is used to reduce the sway of the capacitors as they have entered the test facility, the box. By improving this part of the test process a time saving of 20 seconds per unit can be achieved, equivalent to 7% time reduction. This can be compared to an additional 1400 units each year.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comparative wear and corrosion properties of Cr3C2-NiCr (CC-TS) (a high-velocity oxyfuel [HVOF]) and hard chromium (HC) coating's obtained on a steel substrate have been studied. The structural characterization was done before and after measurements by optical microscopy, scanning electron microscopy, and scanning white light interferometry. Wear and corrosion properties were evaluated by ball on disk (ASTM G99-90), rubber wheel (ASTM G65-91), and electrochemical measurements of open circuit and polarization curves. The best corrosion and wear resistance was for the CC-TS obtained by HVOF. The open-circuit potential values measured for both samples after 18 h of immersion we're: -0.240 and -0.550 V, respectively, for CC-TS and HC, versus Ag/AgCl,KClsat. Three orders of magnitude lower volume loss were found for CC-TS (HVOF) after friction tests compared with HC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)