939 resultados para hearing aid implants
Resumo:
CONCLUSIONS: Speech understanding is better with the Baha Divino than with the Baha Compact in competing noise from the rear. No difference was found for speech understanding in quiet. Subjectively, overall sound quality and speech understanding were rated better for the Baha Divino. OBJECTIVES: To compare speech understanding in quiet and in noise and subjective ratings for two different bone-anchored hearing aids: the recently developed Baha Divino and the Baha Compact. PATIENTS AND METHODS: Seven adults with bilateral conductive or mixed hearing losses who were users of a bone-anchored hearing aid were tested with the Baha Compact in quiet and in noise. Tests were repeated after 3 months of use with the Baha Divino. RESULTS: There was no significant difference between the two types of Baha for speech understanding in quiet when tested with German numbers and monosyllabic words at presentation levels between 50 and 80 dB. For speech understanding in noise, an advantage of 2.3 dB for the Baha Divino vs the Baha Compact was found, if noise was emitted from a loudspeaker to the rear of the listener and the directional microphone noise reduction system was activated. Subjectively, the Baha Divino was rated statistically significantly better in terms of overall sound quality.
Resumo:
Abstract Conclusions: Specific requests for cochlear implantations by persons with psychogenic hearing loss are a relatively new phenomenon. A number of features seems to be over-represented in this group of patients. The existence of these requests stresses the importance of auditory brainstem response (ABR) measurements before cochlear implantation. Objective: To describe the phenomenon of patients with psychogenic hearing losses specifically requesting cochlear implantation, and to gain first insights into the characteristics of this group. Methods: Analysis of all cases seen between 2004 and 2013 at the University Hospital of Bern, Switzerland. Results: Four cochlear implant candidates with psychogenic hearing loss were identified. All were female, aged 23-51 years. Hearing thresholds ranged from 86 dB to 112 dB HL (pure-tone average 500-4000 Hz). ABRs and otoacoustic emissions (OAEs) showed bilaterally normal hearing in two subjects, and hearing thresholds between 30 and 50 dB in the other two subjects. Three subjects suffered from depression and one from a pathologic fear of cancer. Three had a history of five or more previous surgeries. Three were smokers and three reported other close family members with hearing losses. All four were hearing aid users at the time of presentation.
Resumo:
Introdução: O implante coclear (IC) amplamente aceito como forma de intervenção e (re) habilitação nas perdas auditivas severas e profundas nas diversas faixas etárias. Contudo observa-se no usuário do IC unilateral queixas como localização e compreensão sonora em meio ao ruído, gerado pelo padrão anormal de estimulação sensorial. A fim de fornecer os benefícios da audição binaural, é preconizado a estimulação bilateral, seja por meio do IC bilateral ou com a adaptação de um aparelho de amplificação sonora individual (AASI) contralateralmente ao IC. Esta última condição é referida como estimulação bimodal, quando temos, concomitantemente dois modos de estimulação: Elétrica (IC) e acústica (AASI). Não há dados suficientes na literatura voltados à população infantil que esclareça ou demonstre o desenvolvimento do córtex auditivo na audição bimodal. Ressalta-se que não foram encontrados estudos em crianças. Objetivo: Caracterizar o PEAC complexo P1, N1 P2 em usuários da estimulação bimodal e verificar se há correlação com testes de percepção de fala. Metodologia: Estudo descritivo de séries de casos, com a realização do PEAC em cinco crianças usuárias da estimulação bimodal, a partir da metodologia proposta por Ventura (2008) utilizando o sistema Smart EP USB Jr da Intelligent Hearing Systems. Foi utilizado o som de fala /da/, apresentado em campo livre. O exame será realizado em três situações: Somente IC, IC e AASI e somente AASI. A análise dos dados dos potenciais corticais foi realizada após a marcação da presença ou ausência dos componentes do complexo P1-N1-P2 por dois juízes com experiência em potenciais evocados. Resultados: Foi obtida a captação do PEAC em todas as crianças em todas as situações de teste, além do que foi possível observar a correlação destes com os testes de percepção auditiva da fala. Foi possível verificar que o registro dos PEAC é um procedimento viável para a avaliação da criança com estimulação bimodal, porém, ainda não há dados suficientes quanto a utilização deste para a avaliação e indicação do IC bilateral.
Resumo:
The main objective of this study was to describe the outcomes of a communication education program for older people with hearing impairment using the International Outcome Inventory - Alternative Interventions (IOI-AI) and the version for significant others (IOI-AI-SO). Ninety-six people aged 58 to 94 years participated in an interactive group education program for two hours per week for five weeks. The IOI-AI was administered at one to two weeks after the last educational session and 29 significant others also completed the IOI-Al-SO at this time. Overall, positive results were obtained using both questionnaires, and satisfaction with the program was particularly high. Findings also compared favourably to reports of outcomes for other audiological interventions (i.e., another communication training program and hearing aid fitting). Principal components analysis of the IOI-AI revealed a somewhat different factor structure than the original IOI-HA. The two versions of the 101 applied in this study are recommended as simple and effective measures of the outcomes of alternative interventions.
Resumo:
Globally, more than 1000 tonnes of titanium (Ti) is implanted into patients in the form of biomedical devices on an annual basis. Ti is perceived to be ‘biocompatible’ owing to the presence of a robust passive oxide film (approx. 4 nm thick) at the metal surface. However, surface deterioration can lead to the release of Ti ions, and particles can arise as the result of wear and/or corrosion processes. This surface deterioration can result in peri-implant inflammation, leading to the premature loss of the implanted device or the requirement for surgical revision. Soft tissues surrounding commercially pure cranial anchorage devices (bone-anchored hearing aid) were investigated using synchrotron X-ray micro-fluorescence spectroscopy and X-ray absorption near edge structure. Here, we present the first experimental evidence that minimal load-bearing Ti implants, which are not subjected to macroscopic wear processes, can release Ti debris into the surrounding soft tissue. As such debris has been shown to be pro-inflammatory, we propose that such distributions of Ti are likely to effect to the service life of the device.
Resumo:
Aim - This pilot study uses qualitative methods to learn about the psycho-social needs of people who seek help with hearing loss. Background - There has been some emphasis in health policy to reduce the number of appointments required between assessment of hearing loss and fitting of hearing aids. This may respond to audiological needs but may not address the psycho-social needs. This study piloted a phenomenological approach to identify the patient's perspective. Methods - A phenomenological approach was taken to provide description of patient perspectives. Findings - Six patients reported that help-seeking was primarily influenced by the need to appease social partners and to improve hearing performance. Hearing aids were not regarded as acceptable treatments. Conclusions - Service providers need to consider the psycho-social consequences of hearing-aid issue alongside audiological needs.
Resumo:
The project consisted of two long-term follow-up studies of preterm children addressing the question whether intrauterine growth restriction affects the outcome. Assessment at 5 years of age of 203 children with a birth weight less than 1000 g born in Finland in 1996-1997 showed that 9% of the children had cognitive impairment, 14% cerebral palsy, and 4% needed a hearing aid. The intelligence quotient was lower (p<0.05) than the reference value. Thus, 20% exhibited major, 19% minor disabilities, and 61% had no functional abnormalities. Being small for gestational age (SGA) was associated with sub-optimal growth later. In children born before 27 gestational weeks, the SGA had more neuropsychological disabilities than those appropriate for gestational age (AGA). In another cohort with birth weight less than 1500 g assessed at 5 years of age, echocardiography showed a thickened interventricular septum and a decreased left ventricular end-diastolic diameter in both SGA and AGA born children. They also had a higher systolic blood pressure than the reference. Laser-Doppler flowmetry showed different endothelium-dependent and -independent vasodilation responses in the AGA children compared to those of the controls. SGA was not associated with cardio-vascular abnormalities. Auditory event-related potentials (AERPs) were recorded using an oddball paradigm with frequency deviants (standard tone 500 Hz and deviant 750-Hz with 10% probability). At term, the P350 was smaller in SGA and AGA infants than in controls. At 12 months, the automatic change detection peak (mismatch negativity, MMN) was observed in the controls. However, the pre-term infants had a difference positivity that correlated with their neurodevelopment scores. At 5 years of age, the P1-deflection, which reflects primary auditory processing, was smaller, and the MMN larger in the preterm than in the control children. Even with a challenging paradigm or a distraction paradigm, P1 was smaller in the preterm than in the control children. The SGA and AGA children showed similar AERP responses. Prematurity is a major risk factor for abnormal brain development. Preterm children showed signs of cardiovascular abnormality suggesting that prematurity per se may carry a risk for later morbidity. The small positive amplitudes in AERPs suggest persisting altered auditory processing in the preterm in-fants.
Resumo:
Debido a la latente preocupación ambiental, la nueva y futura legislación sobre el tema y la forma en que estos factores afectan a las empresas, en este trabajo realizado en la Universidad del Rosario en el primer semestre del 2011, se realizó un estudio de la factibilidad de realizar un plan post consumo para las pilas zinc-aire, referencias R10, R13, R312 y R675 que son utilizadas para los aparatos auditivos. Existe una gran cantidad de pilas zinc-aire que alcanzan el final de su vida útil semanalmente en el país y estas son potencialmente tóxicas y no-biodegradables, por lo que decidimos investigar qué tan factible podía ser hacer una recuperación eficiente de las mismas y qué beneficios podría reportar a las empresas del sector. En la investigación se descartaron opciones como la desmaterialización para venta de sus materiales y la recarga de las pilas para su re-uso, ambas debido a que aún no se cuenta con la tecnología necesaria en el continente para estas opciones. Se consideró entonces el planteamiento de un plan Post-consumo para la correcta disposición de estas pilas, para lo cual es necesario exportarla al continente Europeo. A partir del planteamiento del Plan Post-consumo se hizo un estudio de la factibilidad del mismo, logrando determinar los aspectos principales del plan, como son: Información del producto, del mercado, transporte, almacenamiento, procedimiento del reciclaje, beneficios ambientales, y los costos de llevarlo a cabo.
Resumo:
These three videos show how a Spirit hearing aid is fitted and calibrated.
Resumo:
This study examined hearing impaired listeners’ subjective perceptions of listening environments through a listening questionnaire and compared these results to objective measures mimicked by the questionnaire in the datalogging device SAM (Sound Activity Meter). Results indicate audiologists should not rely on patient reports of “typical” listening environments for hearing aid selection as significant discrepancies were present between several of the subjective and objective measures.
Resumo:
This paper reviews a study to determine optimum hearing aid settings based on loudness.
Resumo:
The purpose of the present study was to evaluate the effects of bimodal (implant plus hearing aid) listening on speech recognition in four different environment conditions. Results indicate that there was little difference in the cochlear implant only and bimodal conditions.
Resumo:
Frequentemente, os indivíduos com perda auditiva têm dificuldade de entender a fala no ambiente ruidoso. OBJETIVO: O objetivo deste estudo foi avaliar clinicamente o desempenho dos indivíduos adultos com deficiência auditiva neurossensorial, com relação à percepção da fala, utilizando o aparelho de amplificação sonora individual digital com o algoritmo de redução de ruído denominado Speech Sensitive Processing, ativado e desativado na presença de um ruído. MATERIAL E MÉTODO: Este estudo de casos foi realizado em 32 indivíduos com deficiência auditiva neurossensorial de graus leve, moderado ou leve a moderado. Foi realizada a avaliação por meio de um teste de percepção de fala, onde se pesquisou o reconhecimento de sentenças na presença de um ruído, para obter a relação sinal/ruído, utilizando o aparelho auditivo digital. RESULTADOS: O algoritmo pôde proporcionar benefício para a maioria dos indivíduos deficientes auditivos, na pesquisa da relação sinal/ruído e os resultados apontaram diferença estatisticamente significante na condição em que o algoritmo encontrava-se ativado, comparado quando o algoritmo não se encontrava ativado. CONCLUSÃO: O uso do algoritmo de redução de ruído deve ser pensado como alternativa clínica, pois observamos a eficácia desse sistema na redução do ruído, melhorando a percepção da fala.
Resumo:
A deficiência auditiva é um dos achados clínicos mais comuns em sujeitos com malformações de orelha. O tratamento consiste em realizar a cirurgia e/ou adaptar o aparelho de amplificação sonora por via óssea (AASI VO). A intervenção precoce é fundamental para favorecer a estimulação auditiva e desenvolvimento da fala e linguagem. OBJETIVO: Caracterizar o perfil audiológico de sujeitos com malformação congênita de orelha externa e/ou média e avaliar o benefício e a satisfação destes com o uso de AASI VO. MÉTODO: Estudo descritivo, sujeitos com malformações congênitas bilaterais de orelha externa e/ou média, deficiência auditiva condutiva ou mista, moderada ou grave e usuários de AASI VO. Avaliação do benefício utilizando teste de reconhecimento de sentenças com ruído competitivo e medidas de ganho funcional e avaliação da satisfação utilizando questionário internacional QI - AASI. RESULTADOS: Foram avaliados 13 sujeitos, sendo 61% do sexo masculino e 80% com deficiência auditiva condutiva moderada ou grave. Houve melhor desempenho na avaliação proposta na condição com AASI, quando comparada à condição sem AASI. CONCLUSÃO: Os AASI VO retroauriculares apresentaram vantagens para a população estudada e devem ser considerados como uma opção para intervenção. A satisfação foi confirmada pelos escores elevados obtidos no QI - AASI.
Resumo:
A low-voltage low-power 2nd-order CMOS pseudo-differential bump-equalizer is presented. Its topology comprises a bandpass section with adjustable center frequency and quality factor, together with a programmable current amplifier. The basic building blocks are triode-operating transconductors, tunable by means of either a DC voltage or a digitally controlled current divider. The bump-equalizer as part of a battery-operated hearing aid device is designed for a 1.4V-supply and a 0.35μm CMOS fabrication process. The circuit performance is supported by a set of simulation results, which indicates a center frequency from 600Hz to 2.4kHz, 1≤Q≤5, and an adjustable gain within ±6dB at center frequency. The filter dynamic range lies around 40dB. Quiescent consumption is kept below 12μW for any configuration of the filter.