953 resultados para fractures, spontaneous - treatment
Resumo:
The aim of this study was to evaluate the difference between a 5-day and a 1-day postoperative course of antibiotic on the incidence of infection after mandibular fractures involving the alveolus. Sixty-two patients with fractures of the mandible involving the dentoalveolar region were randomly assigned to 2 groups, both of which were given amoxicillin/clavulanic acid 1.2 g intravenously every 8 h from admission until 24 h postoperatively. The 5-day group were then given amoxicillin/clavulanic acid 625 mg orally every 8 h for another 4 days. The 1-day group was given an oral placebo at the same intervals. Follow-up appointments were 1, 2, 4, 6, 12 weeks and 6 months postoperatively. Development of an infection was the primary end point. Fifty-nine of the 62 patients completed this study. Six of the 30 patients in the 5-day group (20%) and 6 out of the 29 in the 1-day group (21%) developed local wound infections. Three of the 6 in the 1-day group developed purulent discharge and swelling. One patient in the 5-day group developed a rash on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. In fractures of the mandible involving the alveolus, a 1-day postoperative course of antibiotic is as effective in preventing infective complications as a 5-day regimen.
Resumo:
PURPOSE Fixation of periprosthetic hip fractures with intracortical anchorage might not be feasible in cases with bulky implants and/or poor bone stock. METHODS Rotational stability of new plate inserts with extracortical anchorage for cerclage fixation was measured and compared to the stability found using a standard technique in a biomechanical setup using a torsion testing machine. In a synthetic PUR bone model, transverse fractures were fixed distally using screws and proximally by wire cerclages attached to the plates using "new" (extracortical anchorage) or "standard" (intracortical anchorage) plate inserts. Time to fracture consolidation and complications were assessed in a consecutive series of 18 patients (18 female; mean age 81 years, range 55-92) with periprosthetic hip fractures (ten type B1, eight type C-Vancouver) treated with the new device between July 2003 and July 2010. RESULTS The "new" device showed a higher rotational stability than the "standard" technique (p < 0.001). Fractures showed radiographic consolidation after 14 ± 5 weeks (mean ± SD) postoperatively in patients. Revision surgery was necessary in four patients, unrelated to the new technique. CONCLUSION In periprosthetic hip fractures in which fixation with intracortical anchorage using conventional means might be difficult due to bulky revision stems and/or poor bone stock, the new device may be an addition to the range of existing implants.
Resumo:
The aim of this study was to evaluate the difference between the effect of a 5-day and a 1-day postoperative course of antibiotics on the incidence of infection after midfacial fractures. A total of 98 patients with displaced Le Fort or zygomatic fractures that required operation were randomly assigned into 2 groups, both of which were given amoxicillin/clavulanic acid 1.2g intravenously every 8h from the time of admission until 24h postoperatively. The 5-day group was then given amoxicillin/clavulanic acid 625mg orally 8-hourly for another 4 days. The 1-day group was given placebo orally at the same time points. Patients were followed up 1, 2, 4, 6, and 12 weeks, and 6 months, postoperatively. The development of an infection of the wound was the primary end point. Ninety-four of the 98 patients completed the study. Two of the 45 patients in the 5-day group (4%) and 2/49 in the 1-day group (4%) developed postoperative wound infections. One in each group had a purulent infection, while the others had only wound breakdown. Two patients of the 5-day group and one in the 1-day group developed rashes on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. In midfacial fractures a 1-day course of antibiotics postoperatively is as effective in preventing infective complications as a 5-day regimen.
Resumo:
Primary spontaneous pneumothorax (PSP) affects young healthy people with a significant recurrence rate. Recent advances in treatment have been variably implemented in clinical practice. This statement reviews the latest developments and concepts to improve clinical management and stimulate further research.The European Respiratory Society's Scientific Committee established a multidisciplinary team of pulmonologists and surgeons to produce a comprehensive review of available scientific evidence.Smoking remains the main risk factor of PSP. Routine smoking cessation is advised. More prospective data are required to better define the PSP population and incidence of recurrence. In first episodes of PSP, treatment approach is driven by symptoms rather than PSP size. The role of bullae rupture as the cause of air leakage remains unclear, implying that any treatment of PSP recurrence includes pleurodesis. Talc poudrage pleurodesis by thoracoscopy is safe, provided calibrated talc is available. Video-assisted thoracic surgery is preferred to thoracotomy as a surgical approach.In first episodes of PSP, aspiration is required only in symptomatic patients. After a persistent or recurrent PSP, definitive treatment including pleurodesis is undertaken. Future randomised controlled trials comparing different strategies are required.
Resumo:
Fractures of the pelvic ring are comparatively rare with an incidence of 2-8 % of all fractures depending on the study in question. The severity of pelvic ring fractures can be very different ranging from simple and mostly "harmless" type A fractures up to life-threatening complex type C fractures. Although it was previously postulated that high-energy trauma was necessary to induce a pelvic ring fracture, over the past decades it became more and more evident, not least from data in the pelvic trauma registry of the German Society for Trauma Surgery (DGU), that low-energy minor trauma can also cause pelvic ring fractures of osteoporotic bone and in a rapidly increasing population of geriatric patients insufficiency fractures of the pelvic ring are nowadays observed with no preceding trauma.Even in large trauma centers the number of patients with pelvic ring fractures is mostly insufficient to perform valid and sufficiently powerful monocentric studies on epidemiological, diagnostic or therapeutic issues. For this reason, in 1991 the first and still the only registry worldwide for the documentation and evaluation of pelvic ring fractures was introduced by the Working Group Pelvis (AG Becken) of the DGU. Originally, the main objectives of the documentation were epidemiological and diagnostic issues; however, in the course of time it developed into an increasingly expanding dataset with comprehensive parameters on injury patterns, operative and conservative therapy regimens and short-term and long-term outcome of patients. Originally starting with 10 institutions, in the meantime more than 30 hospitals in Germany and other European countries participate in the documentation of data. In the third phase of the registry alone, which was started in 2004, data from approximately 15,000 patients with pelvic ring and acetabular fractures were documented. In addition to the scientific impact of the pelvic trauma registry, which is reflected in the numerous national and international publications, the dramatically changing epidemiology of pelvic ring fractures, further developments in diagnostics and the changes in operative procedures over time could be demonstrated. Last but not least the now well-established diagnostic and therapeutic algorithms for pelvic ring fractures, which could be derived from the information collated in registry studies, reflect the clinical impact of the registry.
Resumo:
Magnetoencephalography (MEG) allows the real-time recording of neural activity and oscillatory activity in distributed neural networks. We applied a non-linear complexity analysis to resting-state neural activity as measured using whole-head MEG. Recordings were obtained from 20 unmedicated patients with major depressive disorder and 19 matched healthy controls. Subsequently, after 6 months of pharmacological treatment with the antidepressant mirtazapine 30 mg/day, patients received a second MEG scan. A measure of the complexity of neural signals, the Lempel–Ziv Complexity (LZC), was derived from the MEG time series. We found that depressed patients showed higher pre-treatment complexity values compared with controls, and that complexity values decreased after 6 months of effective pharmacological treatment, although this effect was statistically significant only in younger patients. The main treatment effect was to recover the tendency observed in controls of a positive correlation between age and complexity values. Importantly, the reduction of complexity with treatment correlated with the degree of clinical symptom remission. We suggest that LZC, a formal measure of neural activity complexity, is sensitive to the dynamic physiological changes observed in depression and may potentially offer an objective marker of depression and its remission after treatment.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Hemangioma is the most common benign tumor of the liver and it is often asymptomatic. Spontaneous rupture of liver hemangiomas is a rare but potentially lethal complication. Emergent hepatic resection has been the treatment of choice but carries high operative morbidity and mortality. Recently, preoperative transcatheter arterial embolization (TAE) has been used successfully for the management of bleeding ruptured liver tumors and non-operative treatment of symptomatic giant liver hemangiomas. We report a case of spontaneous rupture of a giant hepatic hemangioma that presented with thoracic and abdominal pain and shock due to hemoperitoneum. Once proper diagnosis was made the patient was successfully managed by TAE, followed by conservative hepatic resection.
Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur
Resumo:
Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.
Resumo:
Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.
Resumo:
Osteoporosis is the most common bone disease. Low levels of oestrogens or testosterone are risk factors for primary osteoporosis. The most common cause of secondary osteoporosis is glucocorticoid treatment, but there are many other secondary causes of osteoporosis. Osteoporosis can be secondary to anti-oestrogen treatment for hormone-sensitive breast cancer and to androgen-deprivation therapy for prostate cancer. Zoledronic is the most potent bisphosphonate at inhibiting bone resorption. In osteoporosis, zoledronic acid increases bone mineral density for at least a year after a single intravenous administration. The efficacy and safety of extended release (once-yearly) zoledronic acid in the treatment of osteoporosis is reviewed.
Resumo:
and non-union of bony fractures has been proposed since 1966, little has been known about the effect of HBOT on bone marrow stem cells (BMSC). The aim of this study is to investigate the effect of HBO treatment on osteogenetic differentiation of BMSC and potential application in bone tissue engineering. Adhesive stromal cells harvested from bone marrow were characterized by mesenchymal differentiation potential, cell surface markers and their proliferation capacity. Mesenchymal stem cells, which demonstrated osteogenic, chondrogenic and adipogenic differentiation potential and expressed positively for CD 29, CD 44, CD 73, CD 90, CD 105, CD 166 and negatively for CD34 and CD 45, were selected and treated in a laboratory-scale HBO chamber using different oxygen pressures and exposure times. No obvious effect of HBO treatment on BMSC proliferation was noticed. However, cytotoxic effects of HBO were considerably less pronounced when cells were cultured in medium supplemented with 10% FBS in comparison to medium supplemented with 2% FCS, as was evaluated by WST-1 assay. Under HBO treatment, bone nodules were formed in three days, which was clearly revealed by Von Kossa staining. In contrasts, without HBO treatment, bone nodules were not detected until 9-12 days using the same inducing culture media. Calcium deposition was also significantly increased after three days of HBO treatments compared to no HBO treatment. In addition it was also found that oxygen played a direct role in the enhancement of BMSC osteogenic differentiation, which was independent of the effect of air pressure.
Resumo:
BACKGROUND: Treatment of proximal humerus fractures in elderly patients is challenging because of reduced bone quality. We determined the in vitro characteristics of a new implant developed to target the remaining bone stock, and compared it with an implant in clinical use. METHODS: Following osteotomy, left and right humeral pairs from cadavers were treated with either the Button-Fix or the Humerusblock fixation system. Implant stiffness was determined for three clinically relevant cases of load: axial compression, torsion, and varus bending. In addition, a cyclic varus-bending test was performed. RESULTS: We found higher stiffness values for the humeri treated with the ButtonFix system--with almost a doubling of the compression, torsion, and bending stiffness values. Under dynamic loading, the ButtonFix system had superior stiffness and less K-wire migration compared to the Humerusblock system. INTERPRETATION: When compared to the Humerusblock design, the ButtonFix system showed superior biomechanical properties, both static and dynamic. It offers a minimally invasive alternative for the treatment of proximal humerus fractures.