984 resultados para foreign body reaction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prosthetic meshes are commonly used to correct abdominal wall defects. However, the inflammatory reaction induced by these devices in the peritoneum is not completely understood. We hypothesized that nitric oxide (NO), produced by nitric oxide synthase 2 (NOS2) may modulate the response induced by mesh implants in the abdominal wall and, consequently, affect the outcome of the surgical procedure. Polypropylene meshes were implanted in the peritoneal side of the abdominal wall in wild-type and NOS2-deficient (NOS2(-/-)) mice. After 15 days tissues around the mesh implant were collected, and inflammatory markers (the cytokine interleukin 1 beta (IL-1 beta) and NO) and tissue remodeling (collagen and metalloproteinases (MMP) 2 and 9) were analyzed. The lack of NOS2-derived NO induced a higher incidence of visceral adhesions at the mesh implantation site compared with wild-type mice that underwent the same procedure (P < 0.05). Additionally, higher levels of IL-1 beta were present in the mesh-implanted NOS2(-/-) animals compared with control and wild-type mice. Mesh implantation induced collagen I and III deposition, but in smaller amounts in NOS2(-/-) mice. MMP-9 activity after the surgical procedure was similarly increased in both groups. Conversely, MMP-2 activity was unchanged in mesh-implanted wild-type mice, but was significantly increased in NOS2(-/-) mice (P < 0.01), due to decreased S-nitrosylation of the enzyme in these animals. We conclude that NOS2-derived NO is crucial for an adequate response to and integration of polypropylene mesh implants in the peritoneum. NO deficiency results in a prolonged inflammatory reaction to the mesh implant, and reduced collagen deposition may contribute to an increased incidence of visceral adhesions. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteal macrophages (OsteoMacs) are a special subtype of macrophage residing in bony tissues. Interesting findings from basic research have pointed to their vast and substantial roles in bone biology by demonstrating their key function in bone formation and remodeling. Despite these essential findings, much less information is available concerning their response to a variety of biomaterials used for bone regeneration with the majority of investigation primarily focused on their role during the foreign body reaction. With respect to biomaterials, it is well known that cells derived from the monocyte/macrophage lineage are one of the first cell types in contact with implanted biomaterials. Here they demonstrate extremely plastic phenotypes with the ability to differentiate towards classical M1 or M2 macrophages, or subsequently fuse into osteoclasts or multinucleated giant cells (MNGCs). These MNGCs have previously been characterized as foreign body giant cells and associated with biomaterial rejection, however more recently their phenotypes have been implicated with wound healing and tissue regeneration by studies demonstrating their expression of key M2 markers around biomaterials. With such contrasting hypotheses, it becomes essential to better understand their roles to improve the development of osteo-compatible and osteo-promotive biomaterials. This review article expresses the necessity to further study OsteoMacs and MNGCs to understand their function in bone biomaterial tissue integration including dental/orthopedic implants and bone grafting materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) has been used to describe the histological lesion associated with metal-on-metal (M-M) bearings. We tested the hypothesis that the lymphoid aggregates, associated with ALVAL lesions resemble tertiary lymphoid organs (TLOs). Histopathological changes were examined in the periprosthetic tissue of 62 M-M hip replacements requiring revision surgery, with particular emphasis on the characteristics and pattern of the lymphocytic infiltrate. Immunofluorescence and immunohistochemistry were used to study the classical features of TLOs in cases where large organized lymphoid follicles were present. Synchrotron X-ray fluorescence (XRF) measurements were undertaken to detect localisation of implant derived ions/particles within the samples. Based on type of lymphocytic infiltrates, three different categories were recognised; diffuse aggregates (51%), T cell aggregates (20%), and organised lymphoid aggregates (29%). Further investigation of tissues with organised lymphoid aggregates showed that these tissues recapitulate many of the features of TLOs with T cells and B cells organised into discrete areas, the presence of follicular dendritic cells, acquisition of high endothelial venule like phenotype by blood vessels, expression of lymphoid chemokines and the presence of plasma cells. Co-localisation of implant-derived metals with lymphoid aggregates was observed. These findings suggest that in addition to the well described general foreign body reaction mediated by macrophages and a T cell mediated type IV hypersensitivity response, an under-recognized immunological reaction to metal wear debris involving B cells and the formation of tertiary lymphoid organs occurs in a distinct subset of patients with M-M implants. © 2013 Mittal et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biomaterials have been used for more than a century in the human body to improve body functions and replace damaged tissues. Currently approved and commonly used metallic biomaterials such as, stainless steel, titanium, cobalt chromium and other alloys have been found to have adverse effects leading in some cases, to mechanical failure and rejection of the implant. The physical or chemical nature of the degradation products of some implants initiates an adverse foreign body reaction in the tissue. Some metallic implants remain as permanent fixtures, whereas others such as plates, screws and pins used to secure serious fractures are removed by a second surgical procedure after the tissue has healed sufficiently. However, repeat surgical procedures increase the cost of health care and the possibility of patient morbidity. This study focuses on the development of magnesium based biodegradable alloys/metal matrix composites (MMCs) for orthopedic and cardiovascular applications. The Mg alloys/MMCs possessed good mechanical properties and biocompatible properties. Nine different compositions of Mg alloys/MMCs were manufactured and surface treated. Their degradation behavior, ion leaching, wettability, morphology, cytotoxicity and mechanical properties were determined. Alloying with Zn, Ca, HA and Gd and surface treatment resulted in improved mechanical properties, corrosion resistance, reduced cytotoxicity, lower pH and hydrogen evolution. Anodization resulted in the formation of a distinct oxide layer (thickness 5-10 μm) as compared with that produced on mechanically polished samples (~20-50 nm) under ambient conditions. It is envisaged that the findings of this research will introduce a new class of Mg based biodegradable alloys/MMCs and the emergence of innovative cardiovascular and orthopedic implant devices.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: During the past 15 years, polymethylmethacrylate has been used as a synthetic permanent filler for soft-tissue augmentation. Methods: This. article reports 32 cases of complications seen at Hospital das Clinicas, Faculty of Medicine, University of Sao Paulo, for procedures performed elsewhere. Results: The average age of the patients was 43.6 years (range, 22 to 70 years). Twenty-five patients were women. Sixteen injection procedures were performed by certified plastic surgeons, nine by dermatologists, two by urologists, and one by a nonphysician. Complications were classified into five groups according to main presentation as follows: tissue necrosis (five cases), an acute complication that can be related to technical mistakes but that can also be dependent on patient factors or caused by local infection; granuloma (10 cases), which usually presents as a subacute complication 6 to 12 months after the procedure; chronic inflammatory reactions (10 cases), which usually occur years later and can be related to a triggering event, Such as another operation or infection in the area that was injected (these reactions are immunogenic in origin and may have cyclic periods of activation and remission); chronic inflammatory reaction in the lips (six cases), which may be present with severe symptoms, especially with lymphedema, because of mobility of the lip; and infections (one case), which are rare but possible complications after filling procedures. Conclusions: Polymethylmethacrylate filler complications, despite being rare, are often permanent and difficult or even impossible to treat. Safety guidelines should be observed when considering use of polymethylmethacrylate for augmentation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Treatment of retinal detachment frequently uses biocompatible materials to obtain scleral buckling. These materials are not devoid of consequences on surrounding tissues. In 3 eyes enucleated for failure of surgical treatment using scleral buckling materials, the changes prompted by episcleral implants could be observed. The sclera underwent both an inversion of its curvature and a reduction of its thickness under the material, as well as an encapsulation of the material was observed. While a silicone sponge was used in part to encircle one of these eyes, its capsular inner surface was regular and smooth. In contrast, hydrogel implants used in the three eyes showed a peripheral fragmentation prompting in two of them a typical foreign body giant cell granulomatous reaction. Changes in scleral curvature and scleral thinning were observed reflecting the consequences of the buckling procedure. The capsule formation occurred as it does for any nonabsorbable matérial implanted in tissues. Degradation and fragmentation of the hydrogel material suscitated a granuloma in response to fragments. These hydrogel specific changes should be recognized on microscopic examination of slides of either capsule or eyes previously in contact with this implanted material. They attested of the instability of hydrogel after implantation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective The present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and /or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results Preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion Although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Lesões do tecido ósseo podem ser causadas por fatores congênitos e adquiridos e resultar em deformidade nasal com repercussão estética e funcional. O tratamento cirúrgico desses casos requer reconstruções complexas e frequentemente o uso de biomateriais. O poliuretano derivado do óleo da mamona apresenta uma fórmula com aspectos favoráveis de processabilidade, flexibilidade de formulação, ausência de emissão de vapores tóxicos e baixo custo. Entretanto, a despeito dos resultados favoráveis, estudos referentes ao uso do polímero de mamona, avaliando a reação tecidual no dorso nasal, ainda não foram realizados. OBJETIVO: O objetivo deste estudo consiste em avaliar histologicamente a biocompatibilidade do implante do polímero de mamona no dorso nasal. FORMA DE ESTUDO: Experimental. MATERIAL E MÉTODO: Foram utilizados quatro macacos-pregos da espécie Cebus apella. Um defeito ósseo foi realizado no osso nasal em todos os animais e colocado um implante de polímero de mamona. A eutanásia foi realizada com 270 dias de pós-operatório, e as amostras foram submetidas a estudo histológico. RESULTADOS: Na análise histológica não foi observada a presença de granuloma de corpo estranho ou células fagocitárias. Progressiva formação óssea e maturação foram observadas. CONCLUSÃO: Os resultados macroscópicos e microscópicos mostraram que o implante de polímero de mamona foi biocompatível.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the study was to evaluate the biocompatibility of an adhesive system and a resin component when implanted into connective tissue of rats. Forty sponges embedded in both materials: Scotchbond MP (SBMP/3M - Group A) and 2 - hydroxyethyl-methacrylate (HEMA - Group B), were implanted into dorsal connective tissue of 20 animals. After 7, 15, 30, or 60 days of the implantation, the animals were sacrificed; implant sites were excised and immersed for 24 hours in Kamovisky's fixative. The samples were processed under routine histologic technique, being stained with H & E. Histological evaluation showed that both materials promoted at 7 days intense inflammatory response with predominance of neutrophils and macrophages. The intense connective reaction was replaced for fibroblastic proliferation associated with macrophages and foreign body giant cells over time. The persistent moderate inflammatory reaction adjacent to scattered fragments of materials was greater to HEMA than to the SBMP. Both experimental materials did not show acceptable biocompatibility with connective tissue of rats in spite of allowing an evident connective tissue healing.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

47 end-stage TMJ patients with high occlusal plane angulation, treated with TMJ custom-fitted total joint prostheses and simultaneous maxillo-mandibular counter-clockwise rotation were evaluated for pain and dysfunction presurgery (T1) and at the longest follow-up (T2). Patients subjectively rated their facial pain/headache, TMJ pain, jaw function, diet and disability. Objective functional changes were determined by measuring maximum interincisal opening (MIO) and laterotrusive movements. Patients were divided according to the number of previous failed TMJ surgeries: Group 1 (0-1), Group 2 (2 or more). Significant subjective pain and dysfunction improvements (37-52%) were observed (<0.001). MIO increased 14% but lateral excursion decreased 60%. The groups presented similar absolute changes, but Group 2 showed more dysfunction at T1 and T2. For patients who did not receive fat grafts around the prostheses and had previous failure of proplast/teflon and or silastic TMJ implants, more than half required surgery for TMJ debridement and removal of foreign body giant cell reaction and heterotopic bone formation. End-stage TMJ patients can be treated in one operation with TMJ custom-made total joint prostheses and maxillo-mandibular counter-clockwise rotation, for correction of dentofacial deformity and improvement in pain and TMJ dysfunction; Group 1 patients had better results than Group 2 patients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The authors studied the possible inductive effect of exogenous gangliosides administrated intra-peritoneal and intra-muscular, in 33 rats, after compression and sutures of sciatic nerve. In the animals suffering compression of the sciatic nerve only, the myelin sheath was preserved with good regeneration of the nerve. There was no statistics difference between the two groups with or without the administration of gangliosides. In the group of rats where section of the sciatic nerve and suture were performed, neuroma of amputation as well as dense cicatricial tissue with inflammatory reaction of foreign body type was noted around the sutures. In conclusion, the formation of neuroma of amputation associated with severe inflammatory reaction had an important role in determining the regeneration of the nerve.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Breast implants are medical devices that are used to augment breast size or to reconstruct the breast following mastectomy or to correct a congenital abnormality. Breast implants consist of a silicone outer shell and a filler (most commonly silicone gel or saline). Approximately 5 to 10 million women worldwide have breast implants. Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery and the adverse effects and risks of this material. Thirty Wistar white rats received subcutaneous implants and the revestiment of silicone gel Silimed ®®, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Despite frequent local complications and adverse outcomes, this research showed that the silicone and top layer presented an acceptable chronic inflammatory reaction, which did not significantly differ from the control group. In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism. © AVICENA 2013.