960 resultados para filter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cocktail parties, busy streets, and other noisy environments pose a difficult challenge to the auditory system: how to focus attention on selected sounds while ignoring others? Neurons of primary auditory cortex, many of which are sharply tuned to sound frequency, could help solve this problem by filtering selected sound information based on frequency-content. To investigate whether this occurs, we used high-resolution fMRI at 7 tesla to map the fine-scale frequency-tuning (1.5 mm isotropic resolution) of primary auditory areas A1 and R in six human participants. Then, in a selective attention experiment, participants heard low (250 Hz)- and high (4000 Hz)-frequency streams of tones presented at the same time (dual-stream) and were instructed to focus attention onto one stream versus the other, switching back and forth every 30 s. Attention to low-frequency tones enhanced neural responses within low-frequency-tuned voxels relative to high, and when attention switched the pattern quickly reversed. Thus, like a radio, human primary auditory cortex is able to tune into attended frequency channels and can switch channels on demand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methylene blue (MB) and light are used for virus inactivation of plasma for transfusion. However, the presence of MB has been the subject of concern, and efforts have been made to efficiently remove the dye after photo-treatment. For this study, plasma was collected by apheresis from 10 donors (group A), then treated using the MacoPharma THERAFLEX procedure (MB; 1 microM, and light exposure; 180 J/cm(2)) (group B), and finally filtered in order to remove the dye (group C). Proteins were analyzed by two-dimensional electrophoresis, and peptides showing modifications were characterized by mass spectrometry. Clottable and antigenic fibrinogen levels, as well as fibrin polymerization time were measured. Analyses of the gels focused on a region corresponding to pI between 4.5 and 6.5, and M(r) from 7000 to 58 000. In this area, 387 +/- 47 spots matched, and four of these spots presented significant modifications. They corresponded to changes of the gamma-chain of fibrinogen, of transthyretin, and of apolipoprotein A-I, respectively. A decrease of clottable fibrinogen and a prolongation of fibrin polymerization time were observed in groups B and C. Removal of MB by filtration was not responsible for additional protein alterations. The effect of over-treatment of plasma by very high concentrations of MB (50 microM) in association with prolonged light exposure (3 h) was also analyzed, and showed complex alterations of most of the plasma proteins, including fibrinogen gamma-chain, transthyretin, and apolipoprotein A-I. Our data indicates that MB treatment at high concentration and prolonged illumination severely injure plasma proteins. By contrast, at the MB concentration used to inactivate viruses, damages are apparently very restricted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tavoitteena oli testata ja optimoida erään alipainerumpusuodattimen toimivuutta, ja lisäksi maksimoida tuottavuus ja vertailla erilaisten pesumenetelmientehokkuutta. Testilietteiden ¿ rautarikasteen ja täyteainepastan ¿ karakterisointi oli myös tärkeää. Kirjallisuusosassa tarkasteltiin lyhyesti neste-kiintoaine-erotuksen teoriaa, erityisesti alipainesuodatusta ja alipainerumpusuodattimia. Lisäksi käsiteltiin kapillaarisuodatuksen toimintaperiaatteita sekä selvitettiin kaivosteollisuuden veden talteenottokeinoja, kiintoainejäämien käsittelymenetelmiä ja Chilen kaivosteollisuuden nykytilaa. Työn kokeellinen osa suoritettiin käyttämällä raskaita ja kiintoainepitoisuuksiltaan korkeita lietteitä, eli rautarikastetta ja täyteainepastaa. Kokeet suoritettiin erityisellä alipainerumpusuodattimella, joka oli muokattu perinteisestäpäältä syötettävästä alipainerumpusuodattimesta. Kokeissa tutkittiin pyörimisnopeuden ja erilaisten pesumenetelmien vaikutusta kakun kosteuteen ja suodatuskapasiteettiin. Koelietteiden karakterisointi suoritettiin analysoimalla partikkelikokojakauma, kiintoainepitoisuus, metallipitoisuus ja koostumus. Kokeiden perusteella havaittiin, että rummun pyörimisnopeudella ja lietteen kiintoainepitoisuudella on merkittävä vaikutus suodatuskapasiteettiin ja kakun kosteuspitoisuuteen. Havaittiin myös, että kakun kosteuspitoisuuksissa ja rummun suodatuskapasiteeteissa oli eroja, kun verrattiin eri suodatinväliaineen pesumenetelmiä. Täten oikean pesumenetelmän valinta on tärkeää, ja sillä pystytään lisäämään suodatinväliaineen käyttöikää.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, cleaning of ceramic filter media was studied. Mechanisms of fouling and dissolution of iron compounds, as well as methods for cleaning ceramic membranes fouled by iron deposits were studied in the literature part. Cleaning agents and different methods were closer examined in the experimental part of the thesis. Pyrite is found in the geologic strata. It is oxidized to form ferrous ions Fe(II) and ferric ions Fe(III). Fe(III) is further oxidized in the hydrolysis to form ferric hydroxide. Hematite and goethite, for instance, are naturally occurring iron oxidesand hydroxides. In contact with filter media, they can cause severe fouling, which common cleaning techniques competent enough to remove. Mechanisms for the dissolution of iron oxides include the ligand-promoted pathway and the proton-promoted pathway. The dissolution can also be reductive or non-reductive. The most efficient mechanism is the ligand-promoted reductive mechanism that comprises two stages: the induction period and the autocatalytic dissolution.Reducing agents(such as hydroquinone and hydroxylamine hydrochloride), chelating agents (such as EDTA) and organic acids are used for the removal of iron compounds. Oxalic acid is the most effective known cleaning agent for iron deposits. Since formulations are often more effective than organic acids, reducing agents or chelating agents alone, the citrate¿bicarbonate¿dithionite system among others is well studied in the literature. The cleaning is also enhanced with ultrasound and backpulsing.In the experimental part, oxalic acid and nitric acid were studied alone andin combinations. Also citric acid and ascorbic acid among other chemicals were tested. Soaking experiments, experiments with ultrasound and experiments for alternative methods to apply the cleaning solution on the filter samples were carried out. Permeability and ISO Brightness measurements were performed to examine the influence of the cleaning methods on the samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis of the solutions was carried out to determine the dissolved metals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Air pollution has become an important issue worldwide due to its adverse health effects. Among the different air contaminants, volatile organic compounds (VOCs) are liquids or solids with a high vapor pressure at room temperature that are extremely dangerous for human health. Removal of these compounds can be achieved using nanomaterials with tailored properties such as carbon nanotubes. Methods: Vertically-aligned multiwall carbon nanotubes (CNTs) were successfully grown on quartz filters by means of plasma enhanced chemical vapor deposition (PECVD). Furthermore, a plasma treatment was performed in order to modify the surface properties of the CNTs. The adsorption/desorption processes of three chlorinated compounds (trichloroethylene, 1,2-dichlorobenzene and chloroform) on the CNTs were studied using mass spectrometry measurements with a residual gas analyzer. Results: The adsorption capability of the CNTs increased after functionalization of their surface with a water plasma treatment. In addition, it was found that the presence of aromatic rings, water solubility and polarity of the VOCs play an important role on the adsorption/desorption kinetics at the CNTs surface. Conclusions: This study demonstrates the applicability of CNTs deposited on quartz filters for the removal or selective detection of volatile organic compounds (VOCs). The presence of aromatic rings in VOCs results in π -stacking interactions with a significant increase of their adsorption. On the other hand, it was found that CNTs surface interactions increase with water solubility and polarity of the VOC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of selecting anappropriate wavelet filter is always present in signal compression based on thewavelet transform. In this report, we propose a method to select a wavelet filter from a predefined set of filters for the compression of spectra from a multispectral image. The wavelet filter selection is based on the Learning Vector Quantization (LVQ). In the training phase for the test images, the best wavelet filter for each spectrum has been found by a careful compression-decompression evaluation. Certain spectral features are used in characterizing the pixel spectra. The LVQ is used to form the best wavelet filter class for different types of spectra from multispectral images. When a new image is to be compressed, a set of spectra from that image is selected, the spectra are classified by the trained LVQand the filter associated to the largest class is selected for the compression of every spectrum from the multispectral image. The results show, that almost inevery case our method finds the most suitable wavelet filter from the pre-defined set for the compression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Woven monofilament, multifilament, and spun yarn filter media have long been the standard media in liquid filtration equipment. While the energy for a solid-liquid separation process is determined by the engineering work, it is the interface between the slurry and the equipment - the filter media - that greatly affects the performance characteristics of the unit operation. Those skilled in the art are well aware that a poorly designed filter medium may endanger the whole operation, whereas well-performing filter media can make the operation smooth and economical. As the mineral and pulp producers seek to produce ever finer and more refined fractions of their products, it is becoming increasingly important to be able to dewater slurries with average particle sizes around 1 ¿m using conventional, high-capacity filtration equipment. Furthermore, the surface properties of the media must not allow sticky and adhesive particles to adhere to the media. The aim of this thesis was to test how the dirt-repellency, electrical resistance and highpressure filtration performance of selected woven filter media can be improved by modifying the fabric or yarn with coating, chemical treatment and calendering. The results achieved by chemical surface treatments clearly show that the woven media surface properties can be modified to achieve lower electrical resistance and improved dirt-repellency. The main challenge with the chemical treatments is the abrasion resistance and, while the experimental results indicate that the treatment is sufficiently permanent to resist standard weathering conditions, they may still prove to be inadequately strong in terms of actual use.From the pressure filtration studies in this work, it seems obvious that the conventional woven multifilament fabrics still perform surprisingly well against the coated media in terms of filtrate clarity and cake build-up. Especially in cases where the feed slurry concentration was low and the pressures moderate, the conventional media seemed to outperform the coated media. In the cases where thefeed slurry concentration was high, the tightly woven media performed well against the monofilament reference fabrics, but seemed to do worse than some of the coated media. This result is somewhat surprising in that the high initial specific resistance of the coated media would suggest that the media will blind more easily than the plain woven media. The results indicate, however, that it is actually the woven media that gradually clogs during the coarse of filtration. In conclusion, it seems obvious that there is a pressure limit above which the woven media looses its capacity to keep the solid particles from penetrating the structure. This finding suggests that for extreme pressures the only foreseeable solution is the coated fabrics supported by a strong enough woven fabric to hold thestructure together. Having said that, the high pressure filtration process seems to follow somewhat different laws than the more conventional processes. Based on the results, it may well be that the role of the cloth is most of all to support the cake, and the main performance-determining factor is a long life time. Measuring the pore size distribution with a commercially available porometer gives a fairly accurate picture of the pore size distribution of a fabric, but failsto give insight into which of the pore sizes is the most important in determining the flow through the fabric. Historically air, and sometimes water, permeability measures have been the standard in evaluating media filtration performance including particle retention. Permeability, however, is a function of a multitudeof variables and does not directly allow the estimation of the effective pore size. In this study a new method for estimating the effective pore size and open pore area in a densely woven multifilament fabric was developed. The method combines a simplified equation of the electrical resistance of fabric with the Hagen-Poiseuille flow equation to estimate the effective pore size of a fabric and the total open area of pores. The results are validated by comparison to the measured values of the largest pore size (Bubble point) and the average pore size. The results show good correlation with measured values. However, the measured and estimated values tend to diverge in high weft density fabrics. This phenomenon is thought to be a result of a more tortuous flow path of denser fabrics, and could most probably be cured by using another value for the tortuosity factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkittiin kiekkosuodattimeen liittyviä ulkoisia simulointimalleja integroidussa simulointiympäristössä. Työn tarkoituksena oli parantaa olemassa olevaa mekanistista kiekkosuodatinmallia. Malli laadittiin dynaamiseen paperiteollisuuden tarpeisiin tehtyyn simulaattoriin (APMS), jossa olevaan alkuperäiseen mekanistiseen malliin tehtiin ulkoinen lisämalli, joka käyttää hyväkseen kiekkosuodatinvalmistajan mittaustuloksia. Laitetiedon saatavuutta suodattimien käyttäjille parannettiin luomalla Internetissä sijaitsevalle palvelimelle kiekkosuodattimen laitetietomäärittelyt. Suodatinvalmistaja voi palvella asiakkaitaan viemällä laitetiedot palvelimelle ja yhdistämällä laitetiedon simulointimalliin. Tämä on mahdollista Internetin ylitse käytettävän integroidun simulointiympäristön avulla, jonka on tarkoitus kokonaisvaltaisesti yhdistää simulointi ja prosessisuunnittelu. Suunnittelijalle tarjotaan työkalut, joilla dynaaminen simulointi, tasesimulointi ja kaavioiden piirtäminen onnistuu prosessilaitetiedon ollessa saatavilla. Nämä työkalut on tarkoitus toteuttaa projektissa nimeltä Galleria, jossa luodaan prosessimalli- ja laitetietopalvelin Internetiin. Gallerian käyttöliittymän avulla prosessisuunnittelija voi käyttää erilaisia simulointiohjelmistoja ja niihin luotuja valmiita malleja, sekä saada käsiinsä ajan tasalla olevaa laitetietoa. Ulkoinen kiekkosuodatinmalli laskee suodosvirtaamat ja suodosten pitoisuudet likaiselle, kirkkaalle ja superkirkkaalle suodokselle. Mallin syöttöparametrit ovat kiekkojen pyörimisnopeus, sisään tulevan syötön pitoisuus, suotautuvuus (freeness) ja säätöparametri, jolla säädetään likaisen ja kirkkaan suodoksen keskinäinen suhde. Suotautuvuus kertoo mistä massasta on kyse. Mitä suurempi suotautuvuus on, sitä paremmin massa suodattuu ja sitä puhtaampia suodokset yleensä ovat. Mallin parametrit viritettiin regressioanalyysillä ja valmistajan palautetta apuna käyttäen. Käyttäjä voi valita haluaako hän käyttää ulkoista vai alkuperäistä mallia. Alkuperäinen malli täytyy ensin alustaa antamalla sille nominaaliset toimintapisteet virtaamille ja pitoisuuksille tietyllä pyörimisnopeudella. Ulkoisen mallin yhtälöitä voi käyttää alkuperäisen mallin alustamiseen, jos alkuperäinen malli toimii ulkoista paremmin. Ulkoista mallia voi käyttää myös ilman simulointiohjelmaa Galleria-palvelimelta käsin. Käyttäjälle avautuu näin mahdollisuus tarkastella kiekkosuodattimien parametreja ja nähdä suotautumistulokset oman työasemansa ääreltä mistä tahansa, kunhan Internetyhteys on olemassa. Työn tuloksena kiekkosuodattimien laitetiedon saatavuus käyttäjille parani ja alkuperäisen simulointimallin rajoituksia ja puutteita vähennettiin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vaatimus kuvatiedon tiivistämisestä on tullut entistä ilmeisemmäksi viimeisen kymmenen vuoden aikana kuvatietoon perustuvien sovellutusten myötä. Nykyisin kiinnitetään erityistä huomiota spektrikuviin, joiden tallettaminen ja siirto vaativat runsaasti levytilaa ja kaistaa. Aallokemuunnos on osoittautunut hyväksi ratkaisuksi häviöllisessä tiedontiivistämisessä. Sen toteutus alikaistakoodauksessa perustuu aallokesuodattimiin ja ongelmana on sopivan aallokesuodattimen valinta erilaisille tiivistettäville kuville. Tässä työssä esitetään katsaus tiivistysmenetelmiin, jotka perustuvat aallokemuunnokseen. Ortogonaalisten suodattimien määritys parametrisoimalla on työn painopisteenä. Työssä todetaan myös kahden erilaisen lähestymistavan samanlaisuus algebrallisten yhtälöiden avulla. Kokeellinen osa sisältää joukon testejä, joilla perustellaan parametrisoinnin tarvetta. Erilaisille kuville tarvitaan erilaisia suodattimia sekä erilaiset tiivistyskertoimet saavutetaan eri suodattimilla. Lopuksi toteutetaan spektrikuvien tiivistys aallokemuunnoksen avulla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important problems in optical pattern recognition by correlation is the appearance of sidelobes in the correlation plane, which causes false alarms. We present a method that eliminate sidelobes of up to a given height if certain conditions are satisfied. The method can be applied to any generalized synthetic discriminant function filter and is capable of rejecting lateral peaks that are even higher than the central correlation. Satisfactory results were obtained in both computer simulations and optical implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is often assumed that total head losses in a sand filter are solely due to the filtration media and that there are analytical solutions, such as the Ergun equation, to compute them. However, total head losses are also due to auxiliary elements (inlet and outlet pipes and filter nozzles), which produce undesirable head losses because they increase energy requirements without contributing to the filtration process. In this study, ANSYS Fluent version 6.3, a commercial computational fluid dynamics (CFD) software program, was used to compute head losses in different parts of a sand filter. Six different numerical filter models of varying complexities were used to understand the hydraulic behavior of the several filter elements and their importance in total head losses. The simulation results show that 84.6% of these were caused by the sand bed and 15.4% were due to auxiliary elements (4.4% in the outlet and inlet pipes, and 11.0% in the perforated plate and nozzles). Simulation results with different models show the important role of the nozzles in the hydraulic behavior of the sand filter. The relationship between the passing area through the nozzles and the passing area through the perforated plate is an important design parameter for the reduction of total head losses. A reduced relationship caused by nozzle clogging would disproportionately increase the total head losses in the sand filter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work was to study the characteristics of the most commonly used filter aid materials and their influences on the design of proportioning, mixing, and feeding system for polishing filter family. Based on the literature survey and hands-on experience a system was designed with defined equipment and capital and operating costs. The system was designed to serve precoating and bodyfeeding applications and is easily extended to be used in multiple filter processes. Also a test procedure was carried out where influences of flux and filter cloths to accumulated cake were studied. Filter aid is needed in challenging conditions to improve filtration efficiency and cleaning, and thus extend the operating life of the filter media. Filter aid preparation and feeding system was designed for the use of two different filter aids; precoat and bodyfeed. Precoating is used before the filtration step initiates. If the solids in the filterable solution have a tendency to clog the filter bag easily, precoat is used on the filter bag to obtain better filtration efficiency and quality. Diatomite or perlite is usually used as a precoating substance. The intention is to create a uniform cake to the overall surface of the filter cloth, with predetermined thickness, 2 – 5 mm. This ensures that the clogging of the filter cloth is reduced and the filtration efficiency is increased. Bodyfeed is used if the solids in the filterable solution have a tendency to form a sticky impermeable filter cake. The cake properties are enhanced by maintaining the permeability of the accumulating cake by using the filter aid substance as bodyfeed during the filtration process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, cleaning of ceramic filter plates clogged by iron oxides was studied. Oxalic acid is considered as the most effective cleaning agent for the plates fouled by iron oxides, but when using oxalic acid, sparingly soluble calcium oxalate may be formed and it can blind the filter media. Suitability of another chemical for cleaning the plates clogged by iron oxides was studied in this thesis. The literature part was mostly about the properties of the chemical, about its reactions, industrial uses, safety issues etc. In the experimental part, the efficiency of the chemical for cleaning of the ceramic plates clogged by iron oxides was studied. Two kinds of plates were used in the experiments; the others were clogged by hematite and the others by magnetite. Both soaking and flow-through experiments were done. A suitable concentration, pH and temperature were tried to find in the experiments. Also the effect of ultrasound was studied. The efficiency of the cleaning was examined by measuring the permeability of the plates during the experiments. ICP-OES analysis was performed for determining the amount of dissolved iron in the washing solution. Some experiments were also done with oxalic acid. The results from the oxalic acid experiments were compared to the results from the experiments with the other chemical. In the experiments with the other chemical, the permeability increased more and the amounts of dissolved iron were larger. According to the results from the experiments, the method of application of the washing solutions had an impact on the washing results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Streaming potential measurements for the surface charge characterisation of different filter media types and materials were used. The equipment was developed further so that measurements could be taken along the surfaces, and so that tubular membranes could also be measured. The streaming potential proved to be a very useful tool in the charge analysis of both clean and fouled filter media. Adsorption and fouling could be studied, as could flux, as functions of time. A module to determine the membrane potential was also constructed. The results collected from the experiments conducted with these devices were used in the study of the theory of streaming potential as an electrokinetic phenomenon. Several correction factors, which are derived to take into account the surface conductance and the electrokinetic flow in very narrow capillaries, were tested in practice. The surface materials were studied using FTIR and the results compared with those from the streaming potentials. FTIR analysis was also found to be a useful tool in the characterisation of filters, as well as in the fouling studies. Upon examination of the recorded spectra from different depths in a sample it was possible to determine the adsorption sites. The influence of an external electric field on the cross flow microflltration of a binary protein system was investigated using a membrane electroflltration apparatus. The results showed that a significant improvement could be achieved in membrane filtration by using the measured electrochemical properties to help adjust the process conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this thesis was to compare the efficiency of counter-current and co-current filter cake washing techniques. Filter cake washing is a common unit operation which is used in the chemical process industry for improving the recovery of the liquid phase or for purifying the solid phase of the filter cake. Counter-current displacement washing is more difficult to arrange and it requires additional process equipment but the advantage of counter-current method is that the consumption of wash water that is required for achieving certain filter cake purity may be considerably decreased when compared to the co-current washing method. This is true especially for materials that are difficult to wash. The literature part of this thesis consists of a review of filter cake washing in general, including the basic principles of co-current and counter-current techniques, and a description of the structure and operation of a horizontal vacuum belt filter, which is the equipment considered in the experimental part of this thesis. Also the most common cake washing models are introduced. The experiments were performed by washing wheat apatite filter cakes in a laboratory scale vacuum filter by using both co-current and counter-current washing methods. The main results of these tests were the washing curves that relate the purity of the filter cake to the amount of wash liquid used. Comparison between the obtained washing curves showed that both washing methods could be efficiently applied for achieving good washing results. The differences between the wash liquid consumptions in the co-current and counter-current washing methods were found to be surprisingly small but this is most probably explained by the relatively good washing characteristics of the apatite cakes. The washing models introduced in the literature part were compared with the results obtained from the experiments and it was found out that the studied cake washing processes could be described