955 resultados para field method
Resumo:
The role of sunscreens in preventing skin cancer and melanoma is the focus of ongoing research. Currently, there is no objective measure which can be used in field studies to determine whether a person has applied sunscreen to their skin, and researchers must use indirect assessments such as questionnaires. We sought to develop a rapid, non-invasive method for identifying sunscreen on the skin for use in epidemiological studies. Our basic method is to swab the skin, elute any residues which have been adsorbed onto the swab by rinsing in ethanol, and submit the eluted washings for spectrophotometric analysis. In a controlled study, we applied 0.1 ml of sunscreen to a 50 cm(2) grid on both forearms of 21 volunteers. Each forearm was allocated one of 10 different sunscreen brands. The skin was swabbed after intervals of 20 min, 1 h, 2 h and 4 h. In a field study conducted among 12 children aged 2-4 years attending a child care centre, sunscreen was applied to the faces of half the children. Swabs were then taken from the face and back of all children without knowledge of sunscreen status. In the controlled study, sunscreen was clearly detectable up to 2 h after application for all brands containing organic sunscreen, and marginally detectable at 4 h. In the field study, this method correctly identified all children with and without sunscreen. We conclude that spectrophotometric analysis of skin swabs can reliably detect the presence of sunscreen on the skin for up to 2 It after application. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
We describe a simple method for detection of Plasmodium vivaxand Plasmodium falciparum infection in anophelines using a triplex TaqMan real-time polymerase chain reaction (PCR) assay (18S rRNA). We tested the assay on Anopheles darlingi and Anopheles stephensi colony mosquitoes fed withPlasmodium-infected blood meals and in duplicate on field collected An. darlingi. We compared the real-time PCR results of colony-infected and field collected An. darlingi, separately, to a conventional PCR method. We determined that a cytochromeb-PCR method was only 3.33% as sensitive and 93.38% as specific as our real-time PCR assay with field-collected samples. We demonstrate that this assay is sensitive, specific and reproducible.
Resumo:
A simple extended finite field nuclear relaxation procedure for calculating vibrational contributions to degenerate four-wave mixing (also known as the intensity-dependent refractive index) is presented. As a by-product one also obtains the static vibrationally averaged linear polarizability, as well as the first and second hyperpolarizability. The methodology is validated by illustrative calculations on the water molecule. Further possible extensions are suggested
Resumo:
A large variety of techniques have been used to measure soil CO2 released from the soil surface, and much of the variability observed between locations must be attributed to the different methods used by the investigators. Therefore, a minimum protocol of measurement procedures should be established. The objectives of this study were (a) to compare different absorption areas, concentrations and volumes of the alkali trapping solution used in closed static chambers (CSC), and (b) to compare both, the optimized alkali trapping solution and the soda-lime trapping using CSC to measure soil respiration in sugarcane areas. Three CO2 absorption areas were evaluated (7; 15 and 20 % of the soil emission area or chamber); two volumes of NaOH (40 and 80 mL) at three concentrations (0.1, 0.25 and 0.5 mol L-1). Three different types of alkaline traps were tested: (a), 80 mL of 0.5 mol L-1 NaOH in glass containers, absorption area 15 % (V0.5); (b) 40 mL of 2 mol L-1 NaOH retained in a sponge, absorption area 80 % (S2) and (c) 40 g soda lime, absorption area 15 % (SL). NaOH concentrations of 0.5 mol L-1 or lower underestimated the soil CO2-C flux or CO2 flux. The lower limit of the alkali trap absorption area should be a minimum of 20 % of the area covered by the chamber. The 2 mol L-1 NaOH solution trap (S2) was the most efficient (highest accuracy and highest CO2 fluxes) in measuring soil respiration.
Resumo:
A comprehensive field detection method is proposed that is aimed at developing advanced capability for reliable monitoring, inspection and life estimation of bridge infrastructure. The goal is to utilize Motion-Sensing Radio Transponders (RFIDS) on fully adaptive bridge monitoring to minimize the problems inherent in human inspections of bridges. We developed a novel integrated condition-based maintenance (CBM) framework integrating transformative research in RFID sensors and sensing architecture, for in-situ scour monitoring, state-of-the-art computationally efficient multiscale modeling for scour assessment.
Resumo:
This paper proposes a calibration method which can be utilized for the analysis of SEM images. The field of application of the developed method is a calculation of surface potential distribution of biased silicon edgeless detector. The suggested processing of the data collected by SEM consists of several stages and takes into account different aspects affecting the SEM image. The calibration method doesn’t pretend to be precise but at the same time it gives the basics of potential distribution when the different biasing voltages applied to the detector.
Resumo:
Lähikenttä- ja kaukokenttämikroskopian yhdistäminen: Uusi korkearesoluutioinen menetelmä nanokuvantamiseen. Osteoporoosi on sairaus, jossa luun uudistumisprosessi ei ole enää tasapainossa. Uuden luun muodostuminen on hitaampaa johtuen osteoblastien laskeneesta aktiivisuudesta. Yksi keino estää osteoporoosin syntyä on estää osteoklastien sitoutuminen luun pinnalle, jolloin ne eivät aloita luun syömisprosessia. Tämän Pro gradu -tutkielman tarkoituksena on luoda uusi työkalu osteoklastien sitoutumisen tutkimiseen samanaikaisesti fluoresenssi- ja atomivoimamikroskoopilla. Tätä tarkoitusta varten yhdistettiin atomivoimamikroskooppi sekä STED mikroskooppi. Kirjallisuuskatsauksessa käydään läpi yksityiskohtaisesti molempien mikroskooppitekniikoiden teoriat. Kokeellisessa osiossa esitetään käytetyt metodit ja alustavat tulokset uudella systeemillä. Lisäksi keskustellaan lyhyesti kuvan analysoinnista ImageJohjelmalla. Konfokaalisen fluoresenssimikroskoopin ja atomivoimamikroskoopin yhdistelmä on keksitty jo aikaisemmin, mutta tavallisen konfokaalimikroskoopin erottelukyvyn raja on noin 200 nanometriä johtuen valon diffraktioluonteesta. Yksityiskohdat eivät erotu, jos ne ovat pienempiä kuin puolet käytettävästä aallonpituudesta. STED mikroskooppi mahdollistaa fluoresenssikuvien taltioimisen solunsisäisistä prosesseista 50 nanometrin lateraalisella erotuskyvyllä ja atomivoimamikroskooppi antaa topografista tietoa näytteestä nanometrien erotuskyvyllä. Biologisia näytteitä kuvannettaessa atomivoimamikroskoopin erotuskyky kuitenkin huononee ja yleensä saavutetaan 30-50 nanometrin erotuskyky. Kuvien kerrostaminen vaatii vertauspisteitä ja tätä varten käytettiin atomivoimamikroskoopin kärjen tunnistamista ja referenssipartikkeleita. Kuva-analysointi suoritettiin ImageJ-kuvankäsittelyohjelmalla. Tuloksista nähdään, että referenssipartikkelit ovat hyviä, mutta niiden sijoittaminen tarkasti tietylle kohdealueelle on hankalaa nanoskaalassa. Tästä johtuen kärjen havaitseminen fluoresenssikuvassa on parempi metodi. Atomivoimamikroskoopin kärki voidaan päällystää fluoresoivalla aineella, mutta tämä lisää kärjen aiheuttamaa konvoluutiota mittausdataan. Myös valon takaisinsirontaa kärjestä voidaan tutkia, jolloin konvoluutio ei lisäänny. Ensimmäisten kuvien kerrostamisessa käytettiin hyväksi fluoresoivalla aineella päällystettyä kärkeä ja lopputuloksessa oli vain 50 nanometrin yhteensopimattomuus fluoresenssi- ja topografiakuvan kanssa. STED mikroskoopin avulla nähdään leimattujen proteiinien tarkat sijainnit tiettynä ajankohtana elävän solun sisällä. Samaan aikaan pystytään kuvantamaan solun fyysisiä muotoja tai mitata adheesiovoimia atomivoimamikroskoopilla. Lisäksi voidaan käyttää funktinalisoitua kärkeä, jolla voidaan laukaista signalointitapahtumia solun ja soluväliaineen välillä. Sitoutuminen soluväliaineeseen voidaan rekisteröidä samoin kuin adheesiomediaattorien sijainnit sitoutumisalueella. Nämä dynaamiset havainnot tuottavat uutta informaatiota solun signaloinnista, kun osteoklasti kiinnittyy luun pintaan. Tämä teknologia tarjoaa uuden näkökulman monimutkaisiin signalointiprosesseihin nanoskaalassa ja tulee ratkaisemaan lukemattoman määrän biologisia ongelmia.
Resumo:
The objective of this thesis was to study the effect of pulsed electric field on the preparation of TiO2 nanoparticles via sol-gel method under the visible light irradiation. The literature part introduces properties of different TiO2 crystal forms and principle of photocatalysis. It was expected that pulsed electric field would have an influence on degradation for oxalic acid and formic acid. TiO2 samples were prepared by using three frequencies (50Hz, 294Hz, and 963Hz) and two treatment times (12 minutes and 24 minutes) of pulsed electric field. The photocatalytic activities of TiO2 samples produced with sol-gel method were also compared with the TiO2 particles made by previous study and with the commercial TiO2 powder Aeroxide® (Evonic Degussa GmbH) at the same condition. Results show that pulsed electric field does have an effect on degradation for oxalic acid and formic acid. Generally, higher photocatalytic activities for oxalic acid and formic acid were obtained with lower frequency and longer treatment time of pulsed electric field.
Resumo:
A simple extended finite field nuclear relaxation procedure for calculating vibrational contributions to degenerate four-wave mixing (also known as the intensity-dependent refractive index) is presented. As a by-product one also obtains the static vibrationally averaged linear polarizability, as well as the first and second hyperpolarizability. The methodology is validated by illustrative calculations on the water molecule. Further possible extensions are suggested
Resumo:
The time-of-detection method for aural avian point counts is a new method of estimating abundance, allowing for uncertain probability of detection. The method has been specifically designed to allow for variation in singing rates of birds. It involves dividing the time interval of the point count into several subintervals and recording the detection history of the subintervals when each bird sings. The method can be viewed as generating data equivalent to closed capture–recapture information. The method is different from the distance and multiple-observer methods in that it is not required that all the birds sing during the point count. As this method is new and there is some concern as to how well individual birds can be followed, we carried out a field test of the method using simulated known populations of singing birds, using a laptop computer to send signals to audio stations distributed around a point. The system mimics actual aural avian point counts, but also allows us to know the size and spatial distribution of the populations we are sampling. Fifty 8-min point counts (broken into four 2-min intervals) using eight species of birds were simulated. Singing rate of an individual bird of a species was simulated following a Markovian process (singing bouts followed by periods of silence), which we felt was more realistic than a truly random process. The main emphasis of our paper is to compare results from species singing at (high and low) homogenous rates per interval with those singing at (high and low) heterogeneous rates. Population size was estimated accurately for the species simulated, with a high homogeneous probability of singing. Populations of simulated species with lower but homogeneous singing probabilities were somewhat underestimated. Populations of species simulated with heterogeneous singing probabilities were substantially underestimated. Underestimation was caused by both the very low detection probabilities of all distant individuals and by individuals with low singing rates also having very low detection probabilities.
Resumo:
We describe a remote sensing method for measuring the internal interface height field in a rotating, two-layer annulus laboratory experiment. The method is non-invasive, avoiding the possibility of an interaction between the flow and the measurement device. The height fields retrieved are accurate and highly resolved in both space and time. The technique is based on a flow visualization method developed by previous workers, and relies upon the optical rotation properties of the working liquids. The previous methods returned only qualitative interface maps, however. In the present study, a technique is developed for deriving quantitative maps by calibrating height against the colour fields registered by a camera which views the flow from above. We use a layer-wise torque balance analysis to determine the equilibrium interface height field analytically, in order to derive the calibration curves. With the current system, viewing an annulus of outer radius 125 mm and depth 250 mm from a distance of 2 m, the inferred height fields have horizontal, vertical and temporal resolutions of up to 0.2 mm, 1 mm and 0.04 s, respectively.
Resumo:
Liquid clouds play a profound role in the global radiation budget but it is difficult to remotely retrieve their vertical profile. Ordinary narrow field-of-view (FOV) lidars receive a strong return from such clouds but the information is limited to the first few optical depths. Wideangle multiple-FOV lidars can isolate radiation scattered multiple times before returning to the instrument, often penetrating much deeper into the cloud than the singly-scattered signal. These returns potentially contain information on the vertical profile of extinction coefficient, but are challenging to interpret due to the lack of a fast radiative transfer model for simulating them. This paper describes a variational algorithm that incorporates a fast forward model based on the time-dependent two-stream approximation, and its adjoint. Application of the algorithm to simulated data from a hypothetical airborne three-FOV lidar with a maximum footprint width of 600m suggests that this approach should be able to retrieve the extinction structure down to an optical depth of around 6, and total opticaldepth up to at least 35, depending on the maximum lidar FOV. The convergence behavior of Gauss-Newton and quasi-Newton optimization schemes are compared. We then present results from an application of the algorithm to observations of stratocumulus by the 8-FOV airborne “THOR” lidar. It is demonstrated how the averaging kernel can be used to diagnose the effective vertical resolution of the retrieved profile, and therefore the depth to which information on the vertical structure can be recovered. This work enables exploitation of returns from spaceborne lidar and radar subject to multiple scattering more rigorously than previously possible.
Resumo:
A finite difference technique, based on a projection method, is developed for solving the dynamic three-dimensional Ericksen-Leslie equations for nematic liquid crystals subject to a strong magnetic field. The governing equations in this situation are derived using primitive variables and are solved using the ideas behind the GENSMAC methodology (Tome and McKee [32]; Tome et al. [34]). The resulting numerical technique is then validated by comparing the numerical solution against an analytic solution for steady three-dimensional flow between two-parallel plates subject to a strong magnetic field. The validated code is then employed to solve channel flow for which there is no analytic solution. (C) 2009 Elsevier B.V. All rights reserved.