748 resultados para femur condyle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mandibular condyle from 20-day-old rats was examined in the electron microscope with particular attention to intracellular secretory granules and extracellular matrix. Moreover, type II collagen was localized by an immunoperoxidase method. The condyle has been divided into five layers: (1) the most superficial, articular layer, (2) polymorphic cell layer, (3) flattened cell layer, (4) upper hypertrophic, and (5) lower hypertrophic cell layers. In the articular layer, the cells seldom divide, but in the polymorphic layer and upper part of the flattened cell layer, mitosis gives rise to new cells. In these layers, cells produce two types of secretory granules, usually in distinct stacks of the Golgi apparatus; type a, cylindrical granules, in which 300-nm-long threads are packed in bundles which appear lucent after formaldehyde fixation; and type b, spherical granules loaded with short, dotted filaments. The matrix is composed of thick banded lucent fibrils in a loose feltwork of short, dotted filaments. The cells arising from mitosis undergo endochondral differentiation, which begins in the lower part of the flattened cell layer and is completed in the upper hypertrophic cell layer; it is followed by gradual cell degeneration in the lower hypertrophic cell layer. The cells produce two main types of secretory granules: type b as above; and type c, ovoid granules containing 300-nm-long threads associated with short, dotted filaments. A possibly different secretory granule, type d, dense and cigar-shaped, is also produced. The matrix is composed of thin banded fibrils in a dense feltwork. In the matrix of the superficial layers, the lucency of the fibrils indicated that they were composed of collagen I, whereas the lucency of the cylindrical secretory granules suggested that they transported collagen I precursors to the matrix. Moreover, the use of ruthenium red indicated that the feltwork was composed of proteoglycan; the dotted filaments packed in spherical granules were similar to, and presumably the source of, the matrix feltwork. The superficial layers did not contain collagen II and were collectively referred to as perichondrium. In the deep layers, the ovoid secretory granules displayed collagen II antigenicity and were likely to transport precursors of this collagen to the matrix, where it appeared in the thin banded fibrils. That these granules also carried proteoglycan to the matrix was suggested by their content of short dotted filaments. Thus the deep layers contained collagen II and proteoglycan as in cartilage; they were collectively referred to as the hyaline cartilage region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess whether serum vitamin D concentration is associated with gait status and mortality among patients with fractures of the proximal femur, six months after suffering the fracture. Consecutive patients aged ≥65 years with fractures of the proximal femur, who were admitted to the orthopedics and traumatology ward of our service between January and December 2011, were prospectively evaluated. Clinical, radiological, epidemiological and laboratory analyses were performed, including vitamin D. The patients underwent surgery and were followed up as outpatients, with return visits 15, 30, 60 and 180 days after discharge, at which the outcomes of gait and mortality were evaluated. Eighty-eight patients were evaluated. Two of them were excluded because they presented oncological fractures. Thus, 86 patients of mean age 80.2 ± 7.3 years were studied. In relation to serum vitamin D, the mean was 27.8 ± 14.5 ng/mL, and 33.7% of the patients presented deficiency of this vitamin. In relation to gait, univariate and multivariate logistic regression showed that vitamin D deficiency was not associated with gait recovery, even after adjustment for gender, age and type of fracture (OR: 1.463; 95% CI: 0.524-4.088; p = 0.469). Regarding mortality, Cox regression analysis showed that vitamin D deficiency was not related to its occurrence within six months, even in multivariate analysis (HR: 0.627; 95% CI: 0.180-2.191; p = 0.465). Serum vitamin D concentration was not related to gait status and/or mortality among patients with fractures of the proximal femur, six months after suffering the fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intense selection among broilers, especially for performance and carcass traits, currently favors locomotion problems and bone resistance. Conducting studies relating to development and growth of bone tissue in broilers is necessary to minimize losses. Thus, genetic parameters were estimated for a broiler population's phenotypic traits such as BW at 42 d of age (BW42), chilled femur weight (CFW) and its yield (CFY), and femur measurements: calcium, DM, magnesium, phosphorus, and zinc content; breaking strength; rigidity; length; and thickness. Variance components were estimated through multitrait analyses using the restricted maximum likelihood method. The model included a fixed group effect (sex and hatch) and additive and residual genetic random effects. The heritability estimates we obtained ranged from 0.10 ± 0.05 to 0.50 ± 0.08 for chilled femur yield and BW42, respectively, and indicated that the traits can respond to the selection process, except for CFY, which presented low-magnitude heritability coefficients. Genetic correlation estimates between breaking strength, rigidity, and traits related to mineral content indicated that selection that aims to improve the breaking strength resistance of the femur is highly correlated with mineral content. Given the genetic correlation estimates between BW42 and minerals, it is suggested that in this population, selection for BW42 can be performed with greater intensity without affecting femoral integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Femtosecond lasers have been widely used in laser surgery as an instrument for contact-free tissue removal of hard dental, restorative materials, and osseous tissues, complementing conventional drilling or cutting tools. In order to obtain a laser system that provides an ablation efficiency comparable to mechanical instruments, the laser pulse rate must be maximal without causing thermal damage. The aim of this study was to compare the different morphological characteristics of the hard tissue after exposure to lasers operating in the femtosecond pulse regime. Two different kinds of samples were irradiated: dentin from human extracted teeth and bovine femur samples. Different procedures were applied, while paying special care to preserving the structures. The incubation factor S was calculated to be 0.788 +/- 0.004 for the bovine femur bone. These results indicate that the incubation effect is still substantial during the femtosecond laser ablation of hard tissues. The plasma-induced ablation has reduced side effects, i.e., we observe less thermal and mechanical damage when using a superficial femtosecond laser irradiation close to the threshold conditions. In the femtosecond regime, the morphology characteristics of the cavity were strongly influenced by the change of the effective number of pulses. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.4.048001]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Unstable distal femoral fractures in children are challenging lesions with restricted surgical options for adequate stabilization. Elastic nails have become popular for treating femoral shaft fractures, yet they are still challenging for using in distal fractures. The aim of this study was to test whether end caps (CAP) inserted into the nail extremity improved the mechanical stabilization of a segmental defect at the distal femoral metaphyseal-diaphyseal junction created in an artificial pediatric bone model. Methods: Two 3.5-mm titanium elastic nails (TEN) were introduced intramedullary into pediatric femur models, and a 7.0-mm-thick segmental defect was created at the distal diaphyseal-metaphyseal junction. Nondestructive 4-point bending, axial-bending, and torsion tests were conducted. After this, the end caps were inserted into the external tips of the nails and then screwed into the bone cortex. The mechanical tests were repeated. Stiffness, displacement, and torque were analyzed using the Wilcoxon nonparametric test for paired samples. Results: In the combined axial-bending tests, the TEN + CAP combination was 8.75% stiffer than nails alone (P < 0.01); in torsion tests, the TEN + CAP was 14% stiffer than nails alone (P < 0.01). In contrast, the 4-point bending test did not show differences between the methods (P = 0.91, stiffness; P = 0.51, displacement). Thus, the end caps contributed to an increase in the construct stability for torsion and axial-bending forces but not for 4-point bending forces. Conclusions: These findings indicate that end caps fitted to elastic nails may contribute to the stabilization of fractures that our model mimics (small distal fragment, bone comminution, and distal bone fragment loss).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is a global public health that affects postmenopausal women due to the deficiency of estrogen, a hormone that plays an important role in the microarchitecture of bone tissue. Osteoporosis predisposes to pathological bone fracture that can be repaired by conventional methods. However, depending on the severity and quantity of bone loss, the use of autogenous grafts or biomaterials such as hydroxyapatite might be necessary. The latter has received increasing attention in the medical field because of its good biological properties such as osteoconductivity and biocompatibility with bone tissue. The objective of this study was to evaluate using histologic and radiographic analyses, the osteogenic capacity of hydroxyapatite implanted into the femur of rats with ovariectomy-induced osteoporosis. Eighteen rats were divided into three groups with six animals in each: group nonovariectomized, bilaterally ovariectomized not receiving estrogen replacement therapy, and bilaterally ovariectomized submitted to estrogen replacement therapy. Defects were created experimentally in the distal epiphysis of the femur with a surgical drill and filled with porous hydroxyapatite granules. The animals were sacrificed 8 weeks after surgery. The volume of newly formed bone in the implant area was quantified by morphometrical methods. The results were analyzed by ANOVA followed by the Tukey test (P < 0.05). The hydroxyapatite granules showed good radiopacity. Histological analysis revealed less quantity of newly formed bone in the ovariectomized group not submitted to hormone replacement therapy. In conclusion, bone neoformation can be expected even in bones compromised by estrogen deficiency, but the quantity and velocity of bone formation are lower. Microsc. Res. Tech., 2011. (c) 2011 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proximal femur is a high-diversity region of the human skeleton, especially at the anterior junction between head and neck, where various bony morphologies have been recognized since mid nineteenth century. Classical literature on this topic is chaotic and contradictory, making almost impossible the comparison of data from different researches. Starting from an extensive bibliographic review, the first standardized method to score these traits has been created. This method allows representing both the anatomical diversity of the region already described in literature and a part of variability not considered before, giving few and univocal definitions and allowing to collect comparable data. The method has been applied to three identified and five archaeological European skeletal collections, with the aim of investigating the distribution of these features by sex, age and side, in different places and time periods. It has also been applied to 3D digital reconstructions of femurs from CT scan files of coxo-femoral joints from fresh cadavers. In addition to the osseous traits described in the standardized method, the presence and frequency of some features known as herniation pits have been scored both on bones and on CT scans. The various osseous traits of the proximal femur are present at similar frequencies in skeletal samples from different countries and different historical periods, even if with clear local differentiation. Some of the features examined show significant trends related to their distribution by gender and age. Some hypotheses are proposed about the etiology of these morphologies and their possible implication with the acquisition of bipedalism in Humans. It is therefore highlighted the possible relation of some of these traits with the development of disorders of the hip joint. Moreover, it is not recommended the use of any of these features as a specific activity-related marker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seventeen bones (sixteen cadaveric bones and one plastic bone) were used to validate a method for reconstructing a surface model of the proximal femur from 2D X-ray radiographs and a statistical shape model that was constructed from thirty training surface models. Unlike previously introduced validation studies, where surface-based distance errors were used to evaluate the reconstruction accuracy, here we propose to use errors measured based on clinically relevant morphometric parameters. For this purpose, a program was developed to robustly extract those morphometric parameters from the thirty training surface models (training population), from the seventeen surface models reconstructed from X-ray radiographs, and from the seventeen ground truth surface models obtained either by a CT-scan reconstruction method or by a laser-scan reconstruction method. A statistical analysis was then performed to classify the seventeen test bones into two categories: normal cases and outliers. This classification step depends on the measured parameters of the particular test bone. In case all parameters of a test bone were covered by the training population's parameter ranges, this bone is classified as normal bone, otherwise as outlier bone. Our experimental results showed that statistically there was no significant difference between the morphometric parameters extracted from the reconstructed surface models of the normal cases and those extracted from the reconstructed surface models of the outliers. Therefore, our statistical shape model based reconstruction technique can be used to reconstruct not only the surface model of a normal bone but also that of an outlier bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistical models have been recently introduced in computational orthopaedics to investigate the bone mechanical properties across several populations. A fundamental aspect for the construction of statistical models concerns the establishment of accurate anatomical correspondences among the objects of the training dataset. Various methods have been proposed to solve this problem such as mesh morphing or image registration algorithms. The objective of this study is to compare a mesh-based and an image-based statistical appearance model approaches for the creation of nite element(FE) meshes. A computer tomography (CT) dataset of 157 human left femurs was used for the comparison. For each approach, 30 finite element meshes were generated with the models. The quality of the obtained FE meshes was evaluated in terms of volume, size and shape of the elements. Results showed that the quality of the meshes obtained with the image-based approach was higher than the quality of the mesh-based approach. Future studies are required to evaluate the impact of this finding on the final mechanical simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoarticular allograft transplantation is a popular treatment method in wide surgical resections with large defects. For this reason hospitals are building bone data banks. Performing the optimal allograft selection on bone banks is crucial to the surgical outcome and patient recovery. However, current approaches are very time consuming hindering an efficient selection. We present an automatic method based on registration of femur bones to overcome this limitation. We introduce a new regularization term for the log-domain demons algorithm. This term replaces the standard Gaussian smoothing with a femur specific polyaffine model. The polyaffine femur model is constructed with two affine (femoral head and condyles) and one rigid (shaft) transformation. Our main contribution in this paper is to show that the demons algorithm can be improved in specific cases with an appropriate model. We are not trying to find the most optimal polyaffine model of the femur, but the simplest model with a minimal number of parameters. There is no need to optimize for different number of regions, boundaries and choice of weights, since this fine tuning will be done automatically by a final demons relaxation step with Gaussian smoothing. The newly developed synthesis approach provides a clear anatomically motivated modeling contribution through the specific three component transformation model, and clearly shows a performance improvement (in terms of anatomical meaningful correspondences) on 146 CT images of femurs compared to a standard multiresolution demons. In addition, this simple model improves the robustness of the demons while preserving its accuracy. The ground truth are manual measurements performed by medical experts.