975 resultados para false aneurysm
Resumo:
Ductus arteriosus aneurysm, a rare and potentially fatal condition, has been reported as a complication after surgical ductus arteriosus closure. Its spontaneous appearance as a septic complication, which was common in the presurgical and preantibiotic era, has been rarely reported in the contemporary literature. Persistence of silent ductus arteriosus in healthy children and adults is a frequent condition that currently has an increasing diagnostic possibility due to the availability of more accurate investigative methods, especially echocardiography. We report the case of a 1-year-old child, in whom no previous heart disease was known, who developed a giant aneurysm of the ductus arteriosus during a staphylococcal infection. This complication appeared after craniotomy for emptying an accidental subdural hematoma. This report associates the persistence of ductus arteriosus with a complication considered rare, which has a rapidly fatal evolution.
Resumo:
We present a case of aneurysmal dilation of the aortic residual segment, involving abdominal vessels in corrective surgeries for thoracoabdominal aortic aneurysm, through the identification of risk groups for recurrent dilation, aiming at using a specific operative technique with a branched graft, to prevent aneurysm relapse.
Resumo:
v.44:no.15(1962)
Resumo:
The unresolved issue of false-positive D-dimer results in the diagnostic workup of pulmonary embolism Pulmonary embolism (PE) remains a difficult diagnosis as it lacks specific symptoms and clinical signs. After the determination of the pretest PE probability by a validated clinical score, D-dimers (DD) is the initial blood test in the majority of patients whose probability is low or intermediate. The low specificity of DD results in a high number of false-positives that then require thoracic angio-CT. A new clinical decision rule, called the Pulmonary Embolism Rule-out criteria (PERC), identifies patients at such low risk that PE can be safely ruled-out without a DD test. Its safety has been confirmed in US emergency departments, but retrospective European studies showed that it would lead to 5-7% of undiagnosed PE. Alternative strategies are needed to reduce the proportion of false-positive DD results.
Resumo:
Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32?33 (97%) cancerous biopsies and rejected 17?20 (85%) noncancerous lesions.
Resumo:
OBJECTIVE: : Intravascular ultrasound (IVUS) generates high definition circumferential cross-sectional images and provides real-time readout of vascular dimensions, including visualization of vessel branches. We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up. METHODS: : Out of consecutive 203 patients with descending thoracic aortic aneurysm, 89 (43.8%) received endovascular treatment [mean age, 68 ± 8 years; range, 29-82; male, 79 (88.7%); female, 10 (11.3%)] without using angiography during the endovascular procedure. IVUS (6 F, 12.5 MHz probe or 10 F 9 MHz) coupled with fluoroscopy for the placement of radiopaque markers was used for target site identification, landing zone measurement, device positioning, and assessment of endovascular repair. RESULTS: : Hospital mortality was 4/89 (4.5%). Number of devices implanted in each patient was 1.2 (range, 1-3). X-ray exposure time was 12 ± 8 minutes. Median procedure time was 63 ± 20 minutes. Conversion to open surgery was necessary in one patient (1.1%) because of aortic dissection. In nine patients (10.1%) left subclavian artery was covered because of a short neck. Two patients (2.2%) had vascular access lesions and required surgical repair. One patient developed paraplegia (1.1%). Early endoleak was observed in eight patients (8.9%) and 4 (4.5%) required additional procedures (proximal or distal extensions). Late conversion was necessary in one patient (1.1%). CONCLUSIONS: : IVUS provides all information necessary for device selection, target site identification as well as safe and correct deployment of thoracic endoprostheses and makes periprocedural angiography unnecessary, thus avoiding the risk of renal failure because of contrast medium.
Resumo:
BACKGROUND: To evaluate the effect of statins on the annual expansion rate (ER) of small infrarenal abdominal aortic aneurysms (AAA). PATIENTS AND METHODS: All patients under regular surveillance for small AAA between January 2000 and September 2007, in the Department of Angiology, Lausanne University Hospital, were included. Inclusion criteria were baseline abdominal aortic diameter between 25 and 55 mm, at least two measurements of AAA diameter and a minimum follow up of 6 months. Patients with Marfan disease, infectious or inflammatory AAA, and patients with prior AAA repair were excluded. The influence of statin use and other factors on ER were examined by bivariate and multivariate analysis. RESULTS: Among 589 patients who underwent an abdominal aorta evaluation, 94 patients (89 % men, mean age 69.1 years) were finally included in the analysis. Baseline AAA size was 39.9 ± 7.7 mm (mean±SE) and 48.7 ± 8.4 mm at end of follow-up. Patients had a regular aneurysm size assessment during 38.5 ± 27.7 months. Mean ER was 3.59 mm/y (± 2.81). The 50 patients who were treated with statin during the study period had a lower ER compared to the 44 controls (2.91 vs 4.37 mm/year, p = 0.01). CONCLUSIONS: This study confirms the considerable individual variations in the AAA expansion rate, and emphasizes the need for regular aortic diameter assessments. In this study, patients treated with statin demonstrate a significant decrease in the ER compared to controls. This finding need to be evaluated in prospective interventional studies powered to demonstrate the potential benefit of statin treatment.
Resumo:
We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.
Resumo:
A 35-year-old drug addict was found dead in a public toilet with a ruptured groin, which was later diagnosed to be a leaking pseudo-aneurysm. Investigation at the scene revealed impressive external hemorrhage related to a groin wound. Post-mortem computed tomography angiography demonstrated an aneurysm of the right femoral artery with leak of contrast liquid. Signs of blood loss were evident at autopsy, and histological examination revealed necrosis and rupture of the pseudo-aneurysm. Toxicological analyses were positive for methadone, cocaine, citalopram, and benzodiazepines. This is the first case report in the literature of a ruptured femoral pseudo-aneurysm with a post-mortem radiological diagnosis.
Resumo:
The prevalence of abdominal aortic aneurysm (AAA) and its risk factors are well known in Western countries but few data are available from low- and middle- income countries. We are not aware of systematically collected population- based data on AAA in the African region. We evaluated the prevalence of AAA in a population- based cardiovascular survey conducted in the Republic of Seychelles in 2004 (Indian Ocean, African region). Among the 353 participants aged 50 to 64 years and screened with ultrasound, the prevalence of AAA was 0.3% (95% CI: 0- 0.9) and the prevalence of ectatic dilatations of the abdominal aorta was 1.5% (95% CI: 0.2- 2.8). The prevalence of AAA in the general population seemed lower in Seychelles than in Western countries, despite a high prevalence in Seychelles of risk factors of AAA, such as smoking (in men), high blood pressure and hypercholesterolaemia.
Resumo:
Stenurus globicephalae Baylis et Daubney, 1925 (Nematoda: Pseudaliidae) was found in the cranial air sinuses of a false killer whale, Pseudorca crassidens (Owen), stranded on the coast of Uruguay in 1999. Although this species has been reported once in P. crassidens from the North Atlantic, this is the first record for South America. A total of 920 specimens were obtained, of which 663 were females (body length: 4.34 ± 0.45 cm) and 257 were males (2.99 ± 0.18 cm). Morphometric details are presented for S. globicephalae in this host, which do not show significant differences from those parasitizing Globicephala melas (Traill), but are distinct from those parasitizing Peponocephala electra (Gray). The host's skull revealed loss of osseous mass with the disappearance of the left zygomatic arch, and the left jaw had three osseous fenestrations in the region related to the organ of acoustic reception. These lesions support the hypothesis that this infection, known as stenurosis, was related to the stranding.