994 resultados para external flow


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work is concerned with the use of the cross correlation technique to measure delay time between two simulated signals displaced with respect to time, in order to develop a cross correlator system that will be used to measure the water and oil pipes flowrate in which the detection system is composed by two external low intensity radiation sources located along the tube and two NaI(Tl) gamma-ray detectors. The final purpose of the correlator system is to use the natural disturbances, as the turbulence in the own flow rather than to inject radioactive tracers to the fluid flow as usually is carried out. In the design of this correlator is evaluated the point-by-point calculation method for the cross correlation function in order to produce a system accurate and fast. This method is divided at the same time in three modes of operation: direct, relay and polarity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow experience, a holistic sensation of total involvement in an activity, seems to have positive influences on musical performance activities. Although its main requirements (balance between challenges and skills, clear goals and unequivocal feedback) are inherent elements of musical practice, there is a lack of research about flow occurrences in the context of musical practice and on how specific practice behaviours affect the experience of flow and its particular dimensions. The aims of this thesis were to investigate advanced performersʼ dispositions to flow in musical practice, and to investigate whether the frequency of these experiences of holistic engagement with practice are associated with self-regulatory practice behaviours. 168 advanced classicallytrained performers (male = 50.0%; female = 50.0%), ranging in age from 18 to 74 years (m = 34.41, SD = 12.39), answered a survey that included two measures: the Dispositional Short Flow Scale, assessing performersʼ flow dispositions, and the Self-Regulated Practice Behaviours Questionnaire, developed specifically for the present research. The overall results of the survey suggested that advanced musicians have high dispositions to flow in musical practice, but not associated with the participantsʼ demographic characteristics. Three of the individual flow indicators were less experienced, suggesting that the most intense flow experiences are rare in musical practice. However, the results point to the existence of another relevant experience, named optimal practice experience. Practice engagement levels were positively associated with knowledge of oneʼs own personal resources and a capacity for practice organization, but not with inclusion/use of external resources. A capacity for setting optimal practice goals was related to self-regulation and to immersion aspects of flow. Current findings offer new clues about the assessment of flow dispositions in performers, helping to clarify how daily practice can heighten positive affective responses in musicians who are vulnerable to the requirements and difficulties of deliberate practice, as well as to other negative practice outcomes. The current research questions issues pertaining to the optimization and sustaining of flow in daily practice, suggesting future directions in the study of the affective subjective functioning of engagement with deliberate practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider laminar high-Reynolds-number flow through a finite-length planar channel, where a portion of one wall is replaced by a thin massless elastic membrane that is held under longitudinal tension T and subject to an external pressure distribution. The flow is driven by a fixed pressure drop along the full length of the channel. We investigate the global stability of two-dimensional Poiseuille flow using a method of matched local eigenfunction expansions, which is compared to direct numerical simulations. We trace the neutral stability curve of the primary oscillatory instability of the system, illustrating a transition from high-frequency ‘sloshing’ oscillations at high T to vigorous ‘slamming’ motion at low T . Small-amplitude sloshing at high T can be captured using a low-order eigenmode truncation involving four surface-based modes in the compliant segment of the channel coupled to Womersley flow in the rigid segments. At lower tensions, we show that hydrodynamic modes contribute increasingly to the global instability and we demonstrate a change in the mechanism of energy transfer from the mean flow, with viscous effects being destabilising. Simulations of finite-amplitude oscillations at low T reveal a generic slamming motion, in which the the flexible membrane is drawn close to the opposite rigid wall before rapidly recovering. A simple model is used to demonstrate how fluid inertia in the downstream rigid channel segment, coupled to membrane curvature downstream of the moving constriction, together control slamming dynamics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Title of dissertation: MAGNETIC AND ACOUSTIC INVESTIGATIONS OF TURBULENT SPHERICAL COUETTE FLOW Matthew M. Adams, Doctor of Philosophy, 2016 Dissertation directed by: Professor Daniel Lathrop Department of Physics This dissertation describes experiments in spherical Couette devices, using both gas and liquid sodium. The experimental geometry is motivated by the Earth's outer core, the seat of the geodynamo, and consists of an outer spherical shell and an inner sphere, both of which can be rotated independently to drive a shear flow in the fluid lying between them. In the case of experiments with liquid sodium, we apply DC axial magnetic fields, with a dominant dipole or quadrupole component, to the system. We measure the magnetic field induced by the flow of liquid sodium using an external array of Hall effect magnetic field probes, as well as two probes inserted into the fluid volume. This gives information about possible velocity patterns present, and we extend previous work categorizing flow states, noting further information that can be extracted from the induced field measurements. The limitations due to a lack of direct velocity measurements prompted us to work on developing the technique of using acoustic modes to measure zonal flows. Using gas as the working fluid in our 60~cm diameter spherical Couette experiment, we identified acoustic modes of the container, and obtained excellent agreement with theoretical predictions. For the case of uniform rotation of the system, we compared the acoustic mode frequency splittings with theoretical predictions for solid body flow, and obtained excellent agreement. This gave us confidence in extending this work to the case of differential rotation, with a turbulent flow state. Using the measured splittings for this case, our colleagues performed an inversion to infer the pattern of zonal velocities within the flow, the first such inversion in a rotating laboratory experiment. This technique holds promise for use in liquid sodium experiments, for which zonal flow measurements have historically been challenging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, the interest of the automotive market for hybrid vehicles has increased due to the more restrictive pollutants emissions legislation and to the necessity of decreasing the fossil fuel consumption, since such solution allows a consistent improvement of the vehicle global efficiency. The term hybridization regards the energy flow in the powertrain of a vehicle: a standard vehicle has, usually, only one energy source and one energy tank; instead, a hybrid vehicle has at least two energy sources. In most cases, the prime mover is an internal combustion engine (ICE) while the auxiliary energy source can be mechanical, electrical, pneumatic or hydraulic. It is expected from the control unit of a hybrid vehicle the use of the ICE in high efficiency working zones and to shut it down when it is more convenient, while using the EMG at partial loads and as a fast torque response during transients. However, the battery state of charge may represent a limitation for such a strategy. That’s the reason why, in most cases, energy management strategies are based on the State Of Charge, or SOC, control. Several studies have been conducted on this topic and many different approaches have been illustrated. The purpose of this dissertation is to develop an online (usable on-board) control strategy in which the operating modes are defined using an instantaneous optimization method that minimizes the equivalent fuel consumption of a hybrid electric vehicle. The equivalent fuel consumption is calculated by taking into account the total energy used by the hybrid powertrain during the propulsion phases. The first section presents the hybrid vehicles characteristics. The second chapter describes the global model, with a particular focus on the energy management strategies usable for the supervisory control of such a powertrain. The third chapter shows the performance of the implemented controller on a NEDC cycle compared with the one obtained with the original control strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical conditioning has been shown to promote tissue formation in a wide variety of tissue engineering efforts. However the underlying mechanisms by which external mechanical stimuli regulate cells and tissues are not known. This is particularly relevant in the area of heart valve tissue engineering (HVTE) owing to the intense hemodynamic environments that surround native valves. Some studies suggest that oscillatory shear stress (OSS) caused by steady flow and scaffold flexure play a critical role in engineered tissue formation derived from bone marrow derived stem cells (BMSCs). In addition, scaffold flexure may enhance nutrient (e.g. oxygen, glucose) transport. In this study, we computationally quantified the i) magnitude of fluid-induced shear stresses; ii) the extent of temporal fluid oscillations in the flow field using the oscillatory shear index (OSI) parameter, and iii) glucose and oxygen mass transport profiles. Noting that sample cyclic flexure induces a high degree of oscillatory shear stress (OSS), we incorporated moving boundary computational fluid dynamic simulations of samples housed within a bioreactor to consider the effects of: 1) no flow, no flexure (control group), 2) steady flow-alone, 3) cyclic flexure-alone and 4) combined steady flow and cyclic flexure environments. We also coupled a diffusion and convention mass transport equation to the simulated system. We found that the coexistence of both OSS and appreciable shear stress magnitudes, described by the newly introduced parameter OSI-:τ: explained the high levels of engineered collagen previously observed from combining cyclic flexure and steady flow states. On the other hand, each of these metrics on its own showed no association. This finding suggests that cyclic flexure and steady flow synergistically promote engineered heart valve tissue production via OSS, so long as the oscillations are accompanied by a critical magnitude of shear stress. In addition, our simulations showed that mass transport of glucose and oxygen is enhanced by sample movement at low sample porosities, but did not play a role in highly porous scaffolds. Preliminary in-house in vitro experiments showed that cell proliferation and phenotype is enhanced in OSI-:τ: environments.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Response surface methodology based on Box-Behnken (BBD) design was successfully applied to the optimization in the operating conditions of the electrochemical oxidation of sanitary landfill leachate aimed for making this method feasible for scale up. Landfill leachate was treated in continuous batch-recirculation system, where a dimensional stable anode (DSA(©)) coated with Ti/TiO2 and RuO2 film oxide were used. The effects of three variables, current density (milliampere per square centimeter), time of treatment (minutes), and supporting electrolyte dosage (moles per liter) upon the total organic carbon removal were evaluated. Optimized conditions were obtained for the highest desirability at 244.11 mA/cm(2), 41.78 min, and 0.07 mol/L of NaCl and 242.84 mA/cm(2), 37.07 min, and 0.07 mol/L of Na2SO4. Under the optimal conditions, 54.99 % of chemical oxygen demand (COD) and 71.07 ammonia nitrogen (NH3-N) removal was achieved with NaCl and 45.50 of COD and 62.13 NH3-N with Na2SO4. A new kinetic model predicted obtained from the relation between BBD and the kinetic model was suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context. The possibility of cephalic venous hypertension with the resultant facial edema and elevated cerebrospinal fluid pressure continues to challenge head and neck surgeons who perform bilateral radical neck dissections during simultaneous or staged procedures. Case Report. The staged procedure in patients who require bilateral neck dissections allows collateral venous drainage to develop, mainly through the internal and external vertebral plexuses, thereby minimizing the risks of deleterious consequences. Nevertheless, this procedure has disadvantages, such as a delay in definitive therapy, the need for a second hospitalization and anesthesia, and the risk of cutting lymphatic vessels and spreading viable cancer cells. In this paper, we discuss the rationale and feasibility of preserving the external jugular vein. Considering the limited number of similar reports in the literature, two cases in which this procedure was accomplished are described. The relevant anatomy and technique are reviewed and the patients' outcomes are discussed. Conclusion. Preservation of the EJV during bilateral neck dissections is technically feasible, fast, and safe, with clinically and radiologically demonstrated patency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this present study was to investigate on the effects of concurrent training with blood flow restriction (BFR-CT) and concurrent training (CT) on the aerobic fitness, muscle mass and muscle strength in a cohort of older individuals. 25 healthy older adults (64.7±4.1 years; 69.33±10.8 kg; 1.6±0.1 m) were randomly assigned to experimental groups: CT (n=8, endurance training (ET), 2 days/week for 30-40 min, 50-80% VO2peak and RT, 2 days/week, leg press with 4 sets of 10 reps at 70-80% of 1-RM with 60 s rest), BFR-CT (n=10, ET, similar to CT, but resistance training with blood flow restriction: 2 days/week, leg press with 1 set of 30 and 3 sets of 15 reps at 20-30% 1-RM with 60 s rest) or control group (n=7). Quadriceps cross-sectional area (CSAq), 1-RM and VO2peak were assessed pre- and post-examination (12 wk). The CT and BFR-CT showed similar increases in CSAq post-test (7.3%, P<0.001; 7.6%, P<0.0001, respectively), 1-RM (38.1%, P<0.001; 35.4%, P=0.001, respectively) and VO2peak (9.5%, P=0.04; 10.3%, P=0.02, respectively). The BFR-CT promotes similar neuromuscular and cardiorespiratory adaptations as CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nitric oxide (NO)-mediated vasodilation plays a key role in gastric mucosal defense, and NO-donor drugs may protect against diseases associated with gastric mucosal blood flow (GMBF) deficiencies. In this study, we used the ex vivo gastric chamber method and Laser Doppler Flowmetry to characterize the effects of luminal aqueous NO-donor drug S-nitroso-N-acetylcysteine (SNAC) solution administration compared to aqueous NaNO2 and NaNO3 solutions (pH 7.4) on GMBF in Sprague-Dawley rats. SNAC solutions (600 μM and 12 mM) led to a rapid threefold increase in GMBF, which was maintained during the incubation of the solutions with the gastric mucosa, while NaNO2 or NaNO3 solutions (12 mM) did not affect GMBF. SNAC solutions (600 μM and 12 mM) spontaneously released NO at 37 °C at a constant rate of 0.3 or 14 nmol·mL-1·min-1, respectively, while NaNO2 (12 mM) released NO at a rate of 0.06 nmol·mL-1·min-1 and NaNO3 (12 mM) did not release NO. These results suggest that the SNAC-induced GMBF increase is due to their higher rates of spontaneous NO release compared to equimolar NaNO2 solutions. Taken together, our data indicate that oral SNAC administration is a potential approach for gastric acid-peptic disorder prevention and treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a combined study of external pressure and Cu-substitution on BaFe2As2 single crystals grown by the in-flux technique. At ambient pressure, the Cu-substitution is known to suppress the spin density wave (SDW) phase in pure BaFe2As2(TSDW ≈ 140 K) and to induce a superconducting (SC) dome with a maximum transition temperature [Formula: see text]. This [Formula: see text] is much lower than the Tc ∼ 15-28 K achieved in the case of Ru, Ni and Co substitutions. Such a lower Tc is attributed to a Cu(2+) magnetic pair-breaking effect. The latter is strongly suppressed by applied pressure, as shown herein, Tc can be significantly enhanced by applying high pressures. In this work, we investigated the pressure effects on Cu(2+) magnetic pair-breaking in the BaFe2-xCuxAs2 series. Around the optimal concentration (xopd = 0.11), all samples showed a substantial increase of Tc as a function of pressure. Yet for those samples with a slightly higher doping level (over-doped regime), Tc presented a dome-like shape with maximum Tc ≃ 8 K. Remarkably interesting, the under-doped samples, e.g. x = 0.02 display a maximum pressure induced Tc ≃ 30 K which is comparable to the maximum Tc's found for the pure compound under external pressures. Furthermore, the magnetoresistance effect as a function of pressure in the normal state of the x = 0.02 sample also presented an evolution consistent with the screening of the Cu(2+) local moments. These findings demonstrate that the Cu(2+) magnetic pair-breaking effect is completely suppressed by applying pressure in the low concentration regime of Cu(2+) substituted BaFe2As2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cases of giant intracavernous aneurysms treated by high flow bypass with saphenous vein graft between the external carotid artery (ECA) and branches of the middle cerebral artery (MCA) are presented. Very often these aneurysms are unclippable because they are fusiform or have a large neck. Occlusion of the internal carotid artery (ICA) is the treatment of choice in many cases. This procedure has however a high risk of brain infarction. Revascularization of the brain by extra-intracranial anastomosis between the superficial temporal artery (STA) and branches of the MCA is frequently performed. This procedure provides however a low flow bypass and brain infarction may occur. We report two cases of giant cavernous sinus aneurysms treated by high flow bypass and endovascular balloon occlusion of the ICA. Immediate high flow revascularization of MCA branches was achieved and the patients showed no ischemic events. Follow-up of 8 and 14 months after operation shows patency of the venous graft and no neurological deficits. Angiographic control examination showed complete aneurysm occlusion in both cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.