945 resultados para exposure risk


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nowadays, aerosol processes are widely used for the manufacture of nanoparticles (NPs), creating an increased occupational exposure risk of workers, laboratory personnel and scientists to airborne particles. There is evidence that possible adverse effects are linked with the accumulation of NPs in target cells, pointing out the importance of understanding the kinetics of particle internalization. In this context, the uptake kinetics of representative airborne NPs over 30 min and their internalization after 24 h post-exposure were investigated by the use of a recently established exposure system. This system combines the production of aerosolized cerium oxide (CeO(2)) NPs by flame spray synthesis with its simultaneous particle deposition from the gas-phase onto A549 lung cells, cultivated at the air-liquid interface. Particle uptake was quantified by mass spectrometry after several exposure times (0, 5, 10, 20 and 30 min). Over 35% of the deposited mass was found internalized after 10 min exposure, a value that increased to 60% after 30 min exposure. Following an additional 24 h post-incubation, a time span, after which adverse biological effects were observed in previous experiments, over 80% of total CeO(2) could be detected intracellularly. On the ultrastructural level, focal cerium aggregates were present on the apical surface of A549 cells and could also be localized intracellularly in vesicular structures. The uptake behaviour of aerosolized CeO(2) is in line with observations on cerium suspensions, where particle mass transport was identified as the rate-limiting factor for NP internalization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tick-borne encephalitis (TBE), a viral infection of the central nervous system, is endemic in many Eurasian countries. In Switzerland, TBE risk areas have been characterized by geographic mapping of clinical cases. Since mass vaccination should significantly decrease the number of TBE cases, alternative methods for exposure risk assessment are required. We established a new PCR-based test for the detection of TBE virus (TBEV) in ticks. The protocol involves an automated, high-throughput nucleic acid extraction method (QIAsymphony SP system) and a one-step duplex real-time reverse transcription-PCR (RT-PCR) assay for the detection of European subtype TBEV, including an internal process control. High usability, reproducibility, and equivalent performance for virus concentrations down to 5 x 10(3) viral genome equivalents/microl favor the automated protocol compared to the modified guanidinium thiocyanate-phenol-chloroform extraction procedure. The real-time RT-PCR allows fast, sensitive (limit of detection, 10 RNA copies/microl), and specific (no false-positive test results for other TBEV subtypes, other flaviviruses, or other tick-transmitted pathogens) detection of European subtype TBEV. The new detection method was applied in a national surveillance study, in which 62,343 Ixodes ricinus ticks were screened for the presence of TBE virus. A total of 38 foci of endemicity could be identified, with a mean virus prevalence of 0.46%. The foci do not fully agree with those defined by disease mapping. Therefore, the proposed molecular test procedure constitutes a prerequisite for an appropriate TBE surveillance. Our data are a unique complement of human TBE disease case mapping in Switzerland.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper evaluates whether the Swiss monitoring programme for foreign substances in animal products fulfils basic epidemiological quality requirements, and identifies possible sources of bias in the selection of samples. The sampling was analysed over a 4-year period (2002-05). The sampling frame in 37 participating abattoirs covered 51% of all slaughtered pigs, 73% of calves, 68% of beef and 36% of cows. The analysis revealed that some sub-populations as defined by the region of origin were statistically over-represented while others were under-represented. The programme that is in accordance with European Union requirements contained some relevant bias. Patterns of under-sampled regions characterized by management type differences were identified. This could lead to an underestimate of the number of contaminated animals within the programme. Although the current sampling was stratified and partially risk-based, its efficiency could be improved by adopting a more targeted approach.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A radioatividade natural presente em solos, rochas e materiais de construção, devida ao 40K e às séries radioativas do 232Th e 238U é a principal contribuição à exposição externa aos seres humanos. Neste trabalho, determinou-se as concentrações de atividade de 226Ra (da série do 238U), 232Th e 40K presentes em 50 amostras de tintas látex de cor branca comercializadas no Brasil, especificamente, 15 do tipo econômico, 15 do tipo standard, 20 do tipo premium e em uma amostra de dióxido de titânio. As amostras foram seladas e armazenadas por um período mínimo de 30 dias para se alcançar o equilíbrio radioativo secular nas séries do 238U e do 232Th e medidas pela técnica analítica de espectrometria gama de alta resolução. As concentrações de atividade foram calculadas utilizando-se as médias ponderadas pelas incertezas do 214Pb e 214Bi para o 226Ra e médias ponderadas pelas incertezas do 228Ac, 212Pb e 212Bi para o 232Th. A concentração de atividade do 40K foi determinada pela sua transição única de 1460,8 keV. Fatores de autoatenuação gama foram calculados e utilizados para correção da concentração de atividade das amostras com densidade maior que 1,0 g.cm-3. Os índices radiológicos equivalente em rádio (Raeq), índice de concentração de atividade (Iγ), índice de risco à exposição gama interna (Hin), o índice de risco à exposição gama externa (Hex) e a taxa de dose (D) e dose efetiva anual (Def) foram calculados a partir das concentrações de atividade do 226Ra, 232Th e 40K. As concentrações de atividade de 226Ra das tintas variaram entre valores abaixo da atividade mínima detectável e 38,7 Bq.kg-1, as de 232Th variaram entre valores abaixo da atividade mínima detectável e 101,2 Bq.kg-1 e as de 40K variaram entre valores abaixo da atividade mínima detectável e 256 Bq.kg-1. O Raeq variou entre 1,41 Bq.kg-1 e 203 Bq.kg-1, o Iγ variou entre 0,0047 e 0,720, o Hin variou entre 0,0076 e 0,653 e o Hex variou entre 0,0038 e 0,549. A taxa de dose variou de 0,170 nGy.h-1 a 21,3 nGy.h-1 e a dose efetiva anual variou entre 0,83 μSv.a-1 e 104,2 μSv.a-1. Estes resultados mostram que as concentrações de atividades das tintas utilizadas neste estudo estão abaixo dos limites recomendados por Hassan et al. para Raeq (370 Bq.kg-1), pela Comissão Européia para o Iγ (limite de 2 para materiais superficiais) e pela Organização para Cooperação Econômica e Desenvolvimento para Hin e para Hex (ambos com limite de 1), para todas as 50 amostras estudadas, mostrando assim a segurança destas tintas com relação a proteção radiológica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.