843 resultados para evaluation of the degree performance
Resumo:
Purpose: The aim of this study was to assess the 6-year performance of the ART (atraumatic restorative treatment) approach in Class III restorations in permanent teeth. Materials and Methods: A total of 127 ART Class III restorations, using Ketac-Molar (3M ESPE) ionomer cement, was performed in 58 adult patients by one experienced operator in 1998. After a 6 years, 34 patients and 65 restorations were evaluated according to ART criteria. Two calibrated examiners carried out the evaluation. Data were analyzed by exact 95% Confidence Interval and Survival Analysis using the Jackknife method for standard error determination. Results: Among assessed restorations, 73.8% (95% CI = 61.5% to 86.2%) were in good condition and classified as successful, with a 67.6% (95% CI = 54.4% to 80.7%) cumulative survival rate. Failed restorations included 13.9% completely or partially missing restorations, 9.2% restorations that had been replaced by other treatment, 1.5% restorations with a large defect at the margin, and 1.5% restorations that presented high wear on the surface. No caries was observed even in those teeth in which restorations were absent. Conclusion: The 6-year success rate of the ART approach in anterior permanent teeth (Class III) was considered high.
Resumo:
Aim To compare a new root canal sealer based on Copaifera multijuga oil-resin (Biosealer) using three other established sealers (Sealer 26 (R), Endofill (R) and AH plus (R)) in terms of their physicochemical properties. Methodology The study was carried out according to the requirements of Specification Number 57 of the American Dental Association (ADA) and consisted of the following tests: setting time, flow, film thickness, dimensional stability, radiopacity and solubility/disintegration. Data were analysed statistically using anova and Tukey`s test for multiple comparisons. The significance level was set at 5% for all analyses. Results Sealer 26 (R) and AH Plus (R) had the longest setting time (P < 0.05). All materials presented flow in with the ADA`s guidelines. Regarding film thick-ness, Sealer 26 (R) did not have a satisfactory performance, as it had a higher mean value than the maximum allowed by the ADA (0.05 mm), being significantly different from the other materials (P < 0.05), which had mean values for film thickness in accordance with the ADA`s recommendations. Regarding the solubility and disintegration, only Endofill (R) did not meet the ADA`s specifications and presented the worst results of all materials (P < 0.05). Sealer 26 (R) presented the greatest dimensional changes and differed significantly from all other sealers (P < 0.05). Biosealer had the lowest radiopacity values and was significantly different from the other sealers (P < 0.05). Conclusion The experimental sealer based on Copaifera multijuga oil-resin presented satisfactory results in the physicochemical tests required by the ADA.
Resumo:
This paper examines the psychometric quality of the Early/Late Preferences Scale (PS) relative to that of the Composite Morningness Scale (CS). Questionnaires were completed by 670 undergraduate students aged 16-37 years (mean 22.5), of whom 64% were female. Both scales displayed satisfactory inter-item correlations and similar total mean scores to those reported previously, although the CS had higher variability. Principal axis factor analysis produced single-factor solutions for both scales, although loadings for Items 7 and 9 on the PS were low. Internal consistencies for both scales were good (PS=0.86, CS=0.90) with only a small improvement achieved by deleting Items 7 and 9 from the PS. Test-retest reliability over 11 weeks was good for both scales (PS=0.92, CS=0.89). Differences between morning, evening and intermediate groups in self-rated alertness at different times of day, and significant correlations with other indices of morning-evening orientation, provided evidence of validity for both scales. These results indicate that PS is psychometrically comparable with CS. In view of its simpler format and lower cultural specificity, PS may be considered a preferable measure for most applications.
Resumo:
The IEEE 802.15.4 protocol has the ability to support time-sensitive Wireless Sensor Network (WSN) applications due to the Guaranteed Time Slot (GTS) Medium Access Control mechanism. Recently, several analytical and simulation models of the IEEE 802.15.4 protocol have been proposed. Nevertheless, currently available simulation models for this protocol are both inaccurate and incomplete, and in particular they do not support the GTS mechanism. In this paper, we propose an accurate OPNET simulation model, with focus on the implementation of the GTS mechanism. The motivation that has driven this work is the validation of the Network Calculus based analytical model of the GTS mechanism that has been previously proposed and to compare the performance evaluation of the protocol as given by the two alternative approaches. Therefore, in this paper we contribute an accurate OPNET model for the IEEE 802.15.4 protocol. Additionally, and probably more importantly, based on the simulation model we propose a novel methodology to tune the protocol parameters such that a better performance of the protocol can be guaranteed, both concerning maximizing the throughput of the allocated GTS as well as concerning minimizing frame delay.
Resumo:
Thesis submitted to the Faculdade de Ciências e Tecnologia to obtain the Master’s degree in Environmental Engineering, profile in Ecological Engineering
Resumo:
Human Immunodeficiency Vírus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and imunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS - Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 ºC, -20 ºC and -70 ºC, while the second was composed of two negative and three positive samples stored at 37 ºC (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Abstract:INTRODUCTION:The Montenegro skin test (MST) has good clinical applicability and low cost for the diagnosis of American tegumentary leishmaniasis (ATL). However, no studies have validated the reference value (5mm) typically used to discriminate positive and negative results. We investigated MST results and evaluated its performance using different cut-off points.METHODS:The results of laboratory tests for 4,256 patients with suspected ATL were analyzed, and 1,182 individuals were found to fulfill the established criteria. Two groups were formed. The positive cutaneous leishmaniasis (PCL) group included patients with skin lesions and positive direct search for parasites (DS) results. The negative cutaneous leishmaniasis (NCL) group included patients with skin lesions with evolution up to 2 months, negative DS results, and negative indirect immunofluorescence assay results who were residents of urban areas that were reported to be probable sites of infection at domiciles and peridomiciles.RESULTS:The PCL and NCL groups included 769 and 413 individuals, respectively. The mean ± standard deviation MST in the PCL group was 12.62 ± 5.91mm [95% confidence interval (CI): 12.20-13.04], and that in the NCL group was 1.43 ± 2.17mm (95% CI: 1.23-1.63). Receiver-operating characteristic curve analysis indicated 97.4% sensitivity and 93.9% specificity for a cut-off of 5mm and 95.8% sensitivity and 97.1% specificity for a cut-off of 6mm.CONCLUSIONS:Either 5mm or 6mm could be used as the cut-off value for diagnosing ATL, as both values had high sensitivity and specificity.
Resumo:
During recent decades it has been possible to identify several problems in construction industry project management, related with to systematic failures in terms of fulfilling its schedule, cost and quality targets, which highlight a need for an evaluation of the factors that may cause these failures. Therefore, it is important to understand how project managers plan the projects, so that the performance and the results can be improved. However, it is important to understand if other areas beyond cost and time management that are mentioned on several studies as the most critical areas, receive the necessary attention from construction project managers. Despite the cost and time are the most sensitive areas/fields, there are several other factors that may lead to project failure. This study aims at understand the reasons that may cause the deviation in terms of cost, time and quality, from the project management point of view, looking at the knowledge areas mentioned by PMI (Project Management Institute).
Resumo:
[Extrat] Multiphase flows are relevant in several industrial processes, thus the availability of accurate numerical modeling tools, able to support the design of products and processes, is of much significance. OpenFOAM version 2.3.x comprises a multiphase flow solver able to couple Eulerian and Lagrangian phases using the discrete particles method (DPM), the DPMFoam. In this work the DPMFoam solver is assessed by comparing its predictions with analytical results and experimental and simulated data available in the literature. They are results from Goldschmidt’s [1] and Hoomans’s [2] theses and the analytical Ergun equation. The goal was to define accuracy and performance of DPMFoam in general scientific or commercial applications. Obtained results demonstrate a good agreement with the reference simulation data and is within reasonable deviations from the experimental values. (...)
Resumo:
PURPOSE: To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS: Seventeen patients with a mean age of 51.7±12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG) - Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS: The mean heart rate during Holter monitoring was 82±8bpm; the maximal heart rate was 126 ± 23bpm and the minimal heart rate 57±7bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3±5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8±0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION: After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.
Resumo:
El láser de baja y media energía y la magnetoterapia son utilizados en desórdenes osteomioarticulares por sus efectos analgésico, antiinflamatorio y trófico, entre los más destacados. Sin embargo, son insuficientes las investigaciones sobre su mecanismo de acción y antecedentes científicos que avalen sus efectos. Es por ello, que la determinación de acontecimientos celulares y moleculares que ocurren durante la interacción de estos tipos de energía con el sistema muscular, sería relevante para el conocimiento y optimización de tales terapias en las ciencias biomédicas. En las miopatías inflamatorias idiopáticas, se encuentra afectada la estructura, morfología y bioquímica del tejido muscular. La energía que éste requiere para el normal funcionamiento es generada en la mitocondria. Esta organela también es la responsable de la generación de especies oxidantes provocando estrés oxidativo y el inicio de los procesos de apoptosis. Por lo antes dicho, consideramos que la determinación de los biomarcadores inflamatorios asociados a estrés oxidativo, realizando el análisis histomorfométrico ultraestructural y valorando la actividad de los complejos enzimáticos mitocondriales, permitiría una evaluación de la acción terapéutica del láser y la magnetoterapia en un modelo experimental de miopatía. Para ello se propone evaluar el efecto de la magnetoterapia y del láser de baja energía (He-Ne y As.Ga) en miopatía experimental determinando indicadores inflamatorios asociados a estrés oxidativo, análisis histomorfométrico y valoración de la actividad enzimática mitocondrial. Específicamente: -Determinar indicadores inflamatorios y de estrés oxidativo: Oxido Nítrico, Grupos carbonilos, L-citrulina, Fibrinógeno, Superóxido dismutasa, Glutation peroxidasa y Catalasa por espectrofotometría. -Identificar los cambios anatomopatológicos del músculo esquelético por microscopía óptica (MO): cuantificación del infiltrado inflamatorio; MO de alta resolución (MOAR) y por microscopía electrónica: histomorfometría de la ultraestructura miofibrilar y mitocondrial. -Valorar las actividades enzimáticas de la citrato sintasa y de los complejos: I (NADH-ubiquinona reductasa), II (succinato-ubiquinona-reductasa) III (ubiquinona-citocromo c-reductasa) y IV (citocromo c-oxidasa); en mitocondrias de tejido muscular por espectrofotometría. -Evaluar la actividad apoptótica en las fibras musculares de los diferentes grupos por ténica de T.U.N.E.L. Las mediciones mitocondriales (por ME) y de infiltrado inflamatorio (por MO) se realizarán en un total de 5 fotos de aumentos similares en forma aleatoria por grupo estudiado (n=10). Los cambios estructurales observados se analizarán en el programa Axiovision 4.8, para cuantificar el área total ocupada, número total y grado de alteración de las mitocondrias y el porcentaje de infiltrado inflamatorio determinando el grado de inflamación. Los resultados de los datos cuantitativos se analizarán aplicando ANAVA (test de Fisher para comparaciones múltiples); y para los datos categóricos se utilizará Chi cuadrado (test de Pearson), estableciéndose un nivel de significación de p < 0.05 para todos los casos. Importancia del Proyecto: La salud y el bienestar del hombre son los logros perseguidos por las ciencias de la salud. La obtención de terapias curativas o paliativas con un mínimo de efectos colaterales para el enfermo se incluye en estos logros. Por esto y todo lo anteriormente expuesto es que consideramos de gran importancia poder esclarecer desde las ciencias básicas los efectos celulares y moleculares en modelos experimentales la acción de la terapia con láser y magnetoterapia para una aplicación clínica con base científica en todas las áreas de las Ciencias Médicas. In the idiopathic inflammatory myopathies, is affected the structure, morphology and biochemistry of muscle tissue. The mitochondria is responsible for the generation of oxidizing species leading to oxidative stress and the beginning of the process of apoptosis. As said before, we consider the determination of inflammatory biomarkers related to oxidative stress, by ultrastructural morphometric analysis and assessing the activity of mitochondrial enzyme complexes, permit an evaluation of the therapeutic action of laser and magnetic therapy in an experimental model myopathy. We propose to evaluate the effect of the treatment identifying indicators in experimental inflammatory myopathy associated with oxidative stress, histomorphometric analysis and assessment of mitochondrial enzyme activity. Specifically -determining: Nitric oxide, carbonyl groups, L-citrulline, fibrinogen, superoxide dismutase, glutathione peroxidase and catalase by spectrophotometry. -Identify the pathological changes in skeletal muscle by optical microscopy (OM): quantification of the inflammatory infiltrate, OM high resolution (MOAR) and electron microscopy, histomorphometry of myofibrillar and mitochondrial ultrastructure. -Evaluate the enzymatic activity of citrate synthase and complexes: I, II, III and IV in mitochondria muscle tissue by spectrophotometry. -Evaluate apoptotic activity in muscle fibers by TUNEL technique of Mitochondrial measurements and inflammatory infiltration (by OM) was performed in a total of 5 photos of similar increases in random by the study group (n = 10). The structural changes observed are discussed in the program Axiovision 4.8, to quantify number, degree of alteration of mitochondria and the percentage of inflammatory infiltrate determining the degree of inflammation. The results of the quantitative data were analyzed using ANOVA (Fisher test), and categorical data with Chi-square (Pearson test), establishing a significance level of p <0.05.
Resumo:
To evaluate the results of xenodiagnosis in chronic Chagas patients infected for ten years or over in an area where transmission has been stemmed as well as the performance of these tests applied one or more times to determine the presence of the paraiste in serum-positive patients for Trypanosoma cruzi infection, 570 xenodiagnosis were performed in 246 patients by exoposing each pacient to 40 Triatoma infestans nymphs of 3 rd/4th stage once, twice or three times, at 30 days intervals. The 570 xenodiagnosis showed overall positive results in 50.7% with a peak 78% in patients under 20 years of age, and 60.5% in those over 60. Of the l58 patients who underwent three xenodiagnosis, 51 (32.3%) had three positive tests, 48 (30.3%) had all negative results, and the remainder had alternating positve and negative findings. There was no difference in number of positive results between the 1st, 2nd and 2rd tests; however, the 1st and 2nd trials added up to 53.2% and the sum total of all three trials was 57.7%.
Resumo:
In 2009, the World Health Organization (WHO) issued a new guideline that stratifies dengue-affected patients into severe (SD) and non-severe dengue (NSD) (with or without warning signs). To evaluate the new recommendations, we completed a retrospective cross-sectional study of the dengue haemorrhagic fever (DHF) cases reported during an outbreak in 2011 in northeastern Brazil. We investigated 84 suspected DHF patients, including 45 (53.6%) males and 39 (46.4%) females. The ages of the patients ranged from five-83 years and the median age was 29. According to the DHF/dengue shock syndrome classification, 53 (63.1%) patients were classified as having dengue fever and 31 (36.9%) as having DHF. According to the 2009 WHO classification, 32 (38.1%) patients were grouped as having NSD [4 (4.8%) without warning signs and 28 (33.3%) with warning signs] and 52 (61.9%) as having SD. A better performance of the revised classification in the detection of severe clinical manifestations allows for an improved detection of patients with SD and may reduce deaths. The revised classification will not only facilitate effective screening and patient management, but will also enable the collection of standardised surveillance data for future epidemiological and clinical studies.
Resumo:
Routine screening of patients at risk of hepatitis C virus (HCV) infection has become a priority given recent improvements in therapeutic options and the asymptomatic nature of most chronic infections. The aim of this study was to evaluate the performance of the Elecsys® Anti-HCV II assay, a new qualitative antibody immunoassay, compared with currently available assays, and assess its suitability for routine diagnostic testing. The sensitivity of the Elecsys® Anti-HCV II, ARCHITECT® Anti-HCV, AxSYM® HCV 3.0, PRISM® HCV, Vitros® ECi Anti-HCV, Elecsys® Anti-HCV, and ADVIA Centaur® HCV assays was compared using commercially available seroconversion panels and samples from patients known to be HCV positive and infected with HCV genotypes 1-6. Specificity was investigated using samples from blood donors, unselected hospitalized patients, and patients with potential cross-reacting factors or from high-risk groups. The Elecsys® Anti-HCV II assay detected more positive bleeds than the comparator assays, was more sensitive in recognizing early HCV infection, and correctly identified all 765 samples known to be HCV positive, regardless of genotype. The overall specificity of the Elecsys(®) Anti-HCV II assay was 99.84% (n = 6,850) using blood donor samples, 99.66% (n = 3,922) using samples from unselected hospitalized patients, and 99.66% (n = 2,397) using samples from patients with potentially cross-reacting factors or from high-risk groups. The specificity of the Elecsys® Anti-HCV II assay was superior or equal to the comparator assays. In conclusion, the Elecsys® Anti-HCV II assay is a sensitive and specific assay suitable for routine use in the reliable detection of anti-HCV antibodies. J. Med. Virol. 85:1362-1368, 2013. © 2013 Wiley Periodicals, Inc.