919 resultados para epoc® blood analysis system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To demonstrate the potential of McCoy cells for the isolation of rabies virus from the cerebrospinal (CSF) fluid of a patient with a diagnosis of rabies, McCoy cells were inoculated with CSF from a patient with a clinical diagnosis of rabies and investigated in terms of morphometric aspect using the JAVA analysis system for the quantification of the increased size of infected cells compared to noninfected cells. The cells were also examined in terms of specific staining for the diagnosis of rabies by the method of Sellers for the observation of intracytoplasmic inclusions and by specific immunofluorescence staining for rabies virus. Infected cells showed changes in cell permeability and morphologic modifications which differed significantly compared to normal cells (P<0.001) when analyzed by the Mann-Whitney and Kruskal-Wallis tests. Intense activity of the endoplasmic reticulum was also observed, as indicated by the presence of intracytoplasmic inclusions visualized by specific staining. The present study demonstrated the isolation of rabies virus from the CSF of a patient with rabies, showing that McCoy cells can be used for the laboratory diagnosis of patients suspected to have rabies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Iron overload (IO) has been associated with increased cardiovascular risk (CVR) and metabolic syndrome (MS) in the general population; both elevated CVR and MS are frequent in HIV- patients. Our aim was to analyze the prevalence of IO in a cohort of asymptomatic patients with HIV infection, and related factors. Methods: Cross-sectional study of a cohort of HIV outpatients in regular follow-up. Demographic, epidemiological, clinical, analytical and therapeutic data were collected. Patients completed a questionnaire about CVR factors and 10-year CV disease risk estimation (Framingham score), underwent a physical exam, and a fasting blood analysis. IO was defined as a plasma ferritin level higher than 200 m/L in women and 300 m/L in men. Results: 571 patients (446 men, 125 women), with a mean age of 43.2 years, sexual transmission of HIV in 68.5%, median CD4 count 474 cell/μL (IQR: 308-666), and 36.3% Aids cases 86.2% were on antiretroviral therapy (ART), and 74.8% of them had undetectable HIV viral load 14.6% met MS criteria, and mean CVR at 10 years was 6.67%. IO was detected in 11% of cases. Patients with IO were more immunosuppressed (CD4 count 369 vs 483/μL, p<0.0001), presented a higher prevalence of detectable HIV viral load (17.6% vs 8.9%; p<0.005), and of Aids cases (14.9% vs 8.7%; p<0.023), and lower plasma levels of cholesterol, HDLc and LDLc (154 vs 183, 34 vs 43, 93 vs 110 mg/dL, respectively; p<0.0001. In the multivariate analysis, the only related factor was CD4 count <350 cell/μL (OR 2.86, 95% CI 1.6-4.9; p<0.0001). IO was not associated with CVR nor with MS. Conclusions: IO is not uncommon in HIV patients, and it is only related with immunosuppression defined as CD4 count <350 cell/ mL, and in contrast to general population, it is not related with increased CVR nor with MS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El proyecto ha consistido en la implantación de una web para DBSS, con doble finalidad: una pública de información general sobre la misma y otra privada para la automatización de la entrada de datos de análisis de sangre y su posterior consulta por parte del paciente. Se han seleccionado las tecnologías adecuadas tanto para el diseño de la web como de las bases de datos asociadas. Se han programado la web y las bases de datos con éxito y se ha realizado la implementación del sistema, realizándose pruebas de funcionamiento internas y externas con éxito, comprobándose la bondad de la aplicación.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary objectives of the Electronic Bulletin Board System (BBS) project were to: (1) Provide an electronic communication tool which would link city and county engineering offices to each other and to other governmental agencies for messaging and data sharing; (2) Provide a dial-up site for reference information or files accessible on-demand; and (3) Provide a "stepping stone" to the world of electronic data transfer, recognizing that most local government employees face a huge complex of technology with limited knowledge of computers and communications tools. The system was designed to be as simple as possible, and to require minimal equipment and software cost to the users. The original system was an Apex 386/25 computer with MS-DOS 5.0 software and the final configuration was an HP Vectra XM Pentium 90 with MS-NT 3.51 and Mustang - Wildcat 5.0 software. The users of the BBS were county engineers and their staff, offices in the central office of the Iowa Department of Transportation (DOT) and Resident Construction Engineers at the Iowa DOT. Much of the activity was between the county engineers, and their staffs, and the Iowa DOT offices with which they have ongoing business activities. The BBS contained files for mapping, Internet e-mail service, Accident Location Analysis System (ALAS) data, Iowa DOT bid lettings, and Autocad and Intergraph maps and standards. The 800 line calls were recorded and gave the best indication of the usage and the trends that were being followed. The usage tended to be higher in the winter months when design activities are occurring and lower in the summer months when the construction is in progress. The project was judged a success. The BBS did provide a "stepping stone" to the world of electronic data transfer.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Commercially available instruments for road-side data collection take highly limited measurements, require extensive manual input, or are too expensive for widespread use. However, inexpensive computer vision techniques for digital video analysis can be applied to automate the monitoring of driver, vehicle, and pedestrian behaviors. These techniques can measure safety-related variables that cannot be easily measured using existing sensors. The use of these techniques will lead to an improved understanding of the decisions made by drivers at intersections. These automated techniques allow the collection of large amounts of safety-related data in a relatively short amount of time. There is a need to develop an easily deployable system to utilize these new techniques. This project implemented and tested a digital video analysis system for use at intersections. A prototype video recording system was developed for field deployment. A computer interface was implemented and served to simplify and automate the data analysis and the data review process. Driver behavior was measured at urban and rural non-signalized intersections. Recorded digital video was analyzed and used to test the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le but de ce travail doctoral était le développement de méthodes analytiques pour la détermination dethyl glucuronide et dethyl sulfate. Ces deux substances sont des métabolites directs de lethanol qui peuvent être détectées pendant des heures jusqu'à des jours dans des fluides corporels, après que léthanol ait été complètement éliminé du corps humain. Ce sont donc des marqueurs de consommation récente d'alcool.La majorité des expériences ont été effectuées en utilisant l'électrophorèse capillaire. Il était envisagé de fournir des méthodes utilisables dans des laboratoires de routine. Des méthodes électrophorétiques ont été développées et optimisées pour la détermination dethyl sulfate dans le sérum et l'urine ainsi que pour lethyl glucuronide dans le sérum. Lethyl glucuronide urinaire a pu être déterminé par un immunoassay commerciale qui a en plus été adapté avec succès pour des échantillons de sérum. Avec toutes ces méthodes d'analyse il était possible d'observer les deux marqueurs de consommation d'alcool récente, même une consommation aussi basse qu'un verre de boissons alcooliques.Finalement, une étude englobant plus de 100 échantillons aété effectuée avec l'ambition de déterminer les valeurs de référence pour lethyl glucuronide dans le sérum et l'urine. De plus, la nécessité de normaliser les échantillons d'urine par rapport à la dilution a été investiguée. Grâce à cette étude des valeurs de cut-off et une base statistique pour l'interprétation probabiliste ont pu être proposées.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carcinoembryonic antigen (CEA) was purified from primary tumour or from hepatic metastases obtained from ten cases of carcinoma of the colon. In nine cases the blood group antigens A, B, Lea or Leb were detected in CEA preparations by the binding of 125I-labelled CEA by blood group antibodies. The extent of binding appeared to preclude simple contamination of CEA preparations by blood group glycoprotein. In all cases the blood group antigens detected were consistent with the patients' known blood groups. Blood group I and i activities were not detected. It is concluded that the determinants of A, B and Lewis antigens and of CEA share the same glycoprotein carrier molecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we develop a new linear approach to identify the parameters of a moving average (MA) model from the statistics of the output. First, we show that, under some constraints, the impulse response of the system can be expressed as a linear combination of cumulant slices. Then, thisresult is used to obtain a new well-conditioned linear methodto estimate the MA parameters of a non-Gaussian process. Theproposed method presents several important differences withexisting linear approaches. The linear combination of slices usedto compute the MA parameters can be constructed from dif-ferent sets of cumulants of different orders, providing a generalframework where all the statistics can be combined. Further-more, it is not necessary to use second-order statistics (the autocorrelation slice), and therefore the proposed algorithm stillprovides consistent estimates in the presence of colored Gaussian noise. Another advantage of the method is that while mostlinear methods developed so far give totally erroneous estimates if the order is overestimated, the proposed approach doesnot require a previous estimation of the filter order. The simulation results confirm the good numerical conditioning of thealgorithm and the improvement in performance with respect to existing methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The construction and evaluation of an inexpensive flow photometer for clinical analysis, using a bicolour LED and a phototransistor adapted for tubular flow cell, are described. The instrument presents some new features such as: automatic zero, electronic calibration and peak-hold signal. When compared with a classical photometer, it is simpler and has the advantages of a flow analysis system: lower volumes of reagents and samples, lower levels of contamination, shorter time for analysis and lower analysis costs. The instrument was used in the determination of the constituents in blood samples. The results obtained agree with those obtained by a classical photometer and the precision was better.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of the present study were 1) to compare results obtained by the traditional manual method of measuring heart rate (HR) and heart rate response (HRR) to the Valsalva maneuver, standing and deep breathing, with those obtained using a computerized data analysis system attached to a standard electrocardiograph machine; 2) to standardize the responses of healthy subjects to cardiovascular tests, and 3) to evaluate the response to these tests in a group of patients with diabetes mellitus (DM). In all subjects (97 healthy and 143 with DM) we evaluated HRR to deep breathing, HRR to standing, HRR to the Valsalva maneuver, and blood pressure response (BPR) to standing up and to a sustained handgrip. Since there was a strong positive correlation between the results obtained with the computerized method and the traditional method, we conclude that the new method can replace the traditional manual method for evaluating cardiovascular responses with the advantages of speed and objectivity. HRR and BPR of men and women did not differ. A correlation between age and HRR was observed for standing (r = -0.48, P<0.001) and deep breathing (r = -0.41, P<0.002). Abnormal BPR to standing was usually observed only in diabetic patients with definite and severe degrees of autonomic neuropathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The carotid bodies from adult spontaneous insulin-dependent diabetic rats (strain BB/S) were perfusion-fixed at normal arterial blood pressure with 3% phosphate-buffered glutaraldehyde and compared with the organs from control rats (strain BB/Sc) prepared in the same way. Serial 5-µm sections were cut, stained, and using an interactive image analysis system, were analysed to determine the volumes of the carotid body and its vascular and extravascular compartments. There was no evidence of systemic arterial disease in the carotid stem arteries in either group of animals, and the microvasculature of the organs appeared normal by light microscopy. The volume of the carotid body was unchanged 3 months after the onset of diabetes but was increased at 6 months. The total vascular volume of the organ was unchanged, but the volume of the small vessels (5-12 µm) was increased. In the control group the small vessels comprised 5% of the total volume of the carotid body, or about 44% of the vascular compartment. The percentage of small vessels increased at 3 months in the diabetic group, but had returned to normal at 6 months. The extravascular volume followed the same pattern as the total carotid body volume and so did not change appreciably when expressed as a percentage of the total volume of the organ. The increase in size of the carotid body in diabetic rats is due, therefore, to an augmented extravascular volume. In one diabetic specimen the carotid sinus nerve showed signs of diabetic neuropathy, axonal swelling and intramyelinic oedema. The clinical implications of these results are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the presence of two new forms of a thrombin-like enzyme, both with apparent molecular masses of 38 kDa, in Bothrops atrox venom. Both share the ability to cleave fibrinogen into fibrin and to digest casein. Both present identical Km on the substrate BApNA. Their N-terminal amino acid sequences are identical for 26 residues, sharing 80% homology with batroxobin and flavoxobin. Two groups of monoclonal antibodies (mAbs) raised against the purified enzyme forms recognized different epitopes of the putative corresponding enzymes present in B. atrox crude venom. On Western blotting analysis of B. atrox crude venom, mAbs 5DB2C8, 5AA10 and 5CF11, but not mAbs 6CC5 and 6AD2-G5, revealed two or more protein bands ranging from 25 to 38 kDa. By immunoprecipitation assays, the 6AD2-G5 mAb was able to precipitate protein bands of 36-38 kDa from B. atrox, B. leucurus, B. pradoi, B. moojeni, B. jararaca and B. neuwiedii crude venoms. Fibrinogen-clotting activity was inhibited when the same venom specimens were pre-incubated with mAb 6AD2-G5, except for B. jararaca and B. neuwiedii.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of a 6-month exercise program on cognitive function and blood viscosity in sedentary elderly men. Forty-six healthy inactive men, aged 60–75 years were randomly distributed into a control group (n=23) and an experimental group (n=23). Participants underwent blood analysis and physical and memory evaluation, before and after the 6-month program of physical exercise. The control group was instructed not to alter its everyday activities; the experimental group took part in the fitness program. The program was conducted using a cycle ergometer, 3 times per week on alternate days, with intensity and volume individualized at ventilatory threshold 1. Sessions were continuous and maximum duration was 60 min each. There was significant improvement in memory (21%; P<0.05), decreased blood viscosity (−19%; P<0.05), and higher aerobic capacity (48%; P<0.05) among participants in the experimental group compared with the control group. These data suggest that taking part in an aerobic physical fitness program at an intensity corresponding to ventilatory threshold-1 may be considered a nonmedication alternative to improve physical and cognitive function.