67 resultados para electroretinogram


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In industrialised countries age-related macular disease (ARMD) is the leading cause of visual loss in older people. Because oxidative stress is purported to be associated with an increased risk of disease development the role of antioxidant supplementation is of interest. Lutein is a carotenoid antioxidant that accumulates within the retina and is thought to filter blue light. Increased levels of lutein have been associated with reduced risk of developing ARMD and improvements in visual and retinal function in eyes with ARMD. The aim of this randomised controlled trial (RCT) was to investigate the effect of a lutein-based nutritional supplement on subjective and objective measures of visual function in healthy eyes and in eyes with age-related maculopathy (ARM) – an early form of ARMD. Supplement withdrawal effects were also investigated. A sample size of 66 healthy older (HO), healthy younger (HY), and ARM eyes were randomly allocated to receive a lutein-based supplement or no treatment for 40 weeks. The supplemented group then stopped supplementation to look at the effects of withdrawal over a further 20 weeks. The primary outcome measure was multifocal electroretinogram (mfERG) N1P1 amplitude. Secondary outcome measures were mfERG N1, P1 and N2 latency, contrast sensitivity (CS), Visual acuity (VA) and macular pigment optical density (MPOD). Sample sizes were sufficient for the RCT to have an 80% power to detect a significant clinical effect at the 5% significance level for all outcome measures when the healthy eye groups were combined, and CS, VA and mfERG in the ARM group. This RCT demonstrates significant improvements in MPOD in HY and HO supplemented eyes. When HY and HO supplemented groups were combined, MPOD improvements were maintained, and mfERG ring 2 P1 latency became shorter. On withdrawal of the supplement mfERG ring 1 N1P1 amplitude reduced in HO eyes. When HO and HY groups were combined, mfERG ring 1 and ring 2 N1P1 amplitudes were reduced. In ARM eyes, ring 3 N2 latency and ring 4 P1 latency became longer. These statistically significant changes may not be clinically significant. The finding that a lutein-based supplement increases MPOD in healthy eyes, but does not increase mfERG amplitudes contrasts with the CARMIS study and contributes to the debate on the use of nutritional supplementation in ARM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocular dimensions are widely recognised as key variants of refractive error. Previously, accurate depiction of eye shape in vivo was largely restricted by limitations in the imaging techniques available. This thesis describes unique applications of the recently introduced 3-dimensional magnetic resonance imaging (MRI) approach to evaluate human eye shape in a group of young adult subjects (n=76) with a range of ametropia (MSE= -19.76 to +4.38D). Specific MRI derived parameters of ocular shape are then correlated with measures of visual function. Key findings include the significant homogeneity of ocular volume in the anterior eye for a range of refractive errors, whilst significant volume changes occur in the posterior eye as a function of ametropia. Anterior vs. posterior eye differences have also been shown through evaluations of equivalent spherical radius; the posterior 25% cap of the eye was shown to be relatively steeper in myopes compared to emmetropes. Further analyses showed differences in retinal quadrant profiles; assessments of the maximum distance from the retinal surface to the presumed visual axes showed exaggerated growth of the temporal quadrant in myopic eyes. Comparisons of retinal contour values derived from transformation of peripheral refraction data were made with MRI; flatter retinal curvature values were noted when using the MRI technique. A distinctive feature of this work is the evaluation of the relationship between ocular structure and visual function. Multiple aspects of visual function were evaluated through several vehicles: multifocal electroretinogram testing, visual field sensitivity testing, and the use of psychophysical methods to determine ganglion cell density. The results show that many quadrantic structural and functional variations exist. In general, the data could not demonstrate a significant correlation between visual function and associated measures of ocular conformation either within or between myopic and emmetropic groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Visually Evoked Subcortical Potential, a far-field signal, was originally defined to flash stimulation as a triphasic positive-negative-positive complex with mean latencies of P21 N26.2 P33.6 (Harding and Rubinstein 1980). Inconsistent with its subcortical source however, the signal was found to be tightly localised to the mastoid. This thesis re-examines the earlier protocols using flash stimulation and with auditory masking establishes by topographic studies that the VESP has a widespread scalp distribution, consistent with a far-field source of the signal, and is not a volume-conducted electroretinogram (ERG). Furthermore, mastoid localisation indicates auditory contamination from the click, on discharge of the photostimulator. The use of flash stimulation could not precisely identify the origin of the response. Possible sources of the VESP are the lateral geniculate body (LGB) and the superior colliculus. The LGB received 80% of the nerve fibres from the retina, and responds to high contrast achromatic stimulation in the form of drifting gratings of high spatial frequencies. At low spatial frequencies, it is more sensitive to colour. The superior colliculus is insensitive to colour and suppressed by contrast and responds to transitory rapid movements, and receives about 20% of the optic nerve fibres. A pattern VESP was obtained to black and white checks as a P23.5 N29.2 P34 complex in 93% of normal subjects at an optimal check size of 12'. It was also present as a P23.0 N28.29 P32.23 complex to red and green luminance balanced checks at 2o check size in 73% of subjects. These results were not volume-conducted pattern electroretinogram responses. These findings are consistent with the spatial frequency properties of the lateral geniculate body which is the considered source of the signal. With further work, the VESP may supplement electrodiagnosis of post-chiasmal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The topographical distribution of the early components of the flash visual evoked response (VER) were investigated using a twenty channel brain mapping system. Thirty subjects, ranging in age from 21 to 84 years, had flash VERs recorded using the standard 10-20 electrode system to a balanced non-cephalic reference. The subjects were divided into three age groups: a young group, a middle group and an older group. The P2 component (positive component around 100-120 msec) of the flash VER was recorded consistently over the occipital region throughout the age range, as was a frontal negative component (N120) of about the same latency. Only the young age group had this single negative component on the frontage channels, whilst the middle age group showed an additional negative component at around 75 msec (N75). Neither group had a recordable P1 component (positive component around 60-75 msec) over the occipital region. The older age group showed both P1 and P2 components over the occipital region with the distribution of the P1 component being more widespread anteriorly. The frontal channels showed both the negative N75 and the later N120 components. The frontal negative components were shown not to be related to the electroretinogram or the balanced non-cephalic reference, but were affected by the type of stimulation. Responses recorded to both pattern reversal and onset/offset stimulation did not show the frontal negative potentials seen with flash stimulation. It was shown that the P1 component is more readily recordable in the elderly and is preceded during middle age by the development of a frontal negative component at around the same latency. The changing morphology of the negative activity in the frontal region across the age range suggests that the use of an Fz reference would produce an artificial P1 component in the middle age group and an enhancement of this component in the elderly, as well as enhance the P2 component in all ages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Parkinson’s disease (PD) is a common disorder of middle-aged and elderly people in which degeneration of the extrapyramidal motor system causes significant movement problems. In some patients, however, there are additional disturbances in sensory systems including loss of the sense of smell and auditory and/or visual problems. This article is a general overview of the visual problems likely to be encountered in PD. Changes in vision in PD may result from alterations in visual acuity, contrast sensitivity, colour discrimination, pupil reactivity, eye movements, motion perception, visual field sensitivity and visual processing speeds. Slower visual processing speeds can also lead to a decline in visual perception especially for rapidly changing visual stimuli. In addition, there may be disturbances of visuo-spatial orientation, facial recognition problems, and chronic visual hallucinations. Some of the treatments used in PD may also have adverse ocular reactions. The pattern electroretinogram (PERG) is useful in evaluating retinal dopamine mechanisms and in monitoring dopamine therapies in PD. If visual problems are present, they can have an important effect on the quality of life of the patient, which can be improved by accurate diagnosis and where possible, correction of such defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multiple system atrophy (MSA) is a rare movement disorder and a member of the 'parkinsonian syndromes', which also include Parkinson's disease (PD), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB) and corticobasal degeneration (CBD). Multiple system atrophy is a complex syndrome, in which patients exhibit a variety of signs and symptoms, including parkinsonism, ataxia and autonomic dysfunction. It can be difficult to separate MSA from the other parkinsonian syndromes but if ocular signs and symptoms are present, they may aid differential diagnosis. Typical ocular features of MSA include blepharospasm, excessive square-wave jerks, mild to moderate hypometria of saccades, impaired vestibular-ocular reflex (VOR), nystagmus and impaired event-related evoked potentials. Less typical features include slowing of saccadic eye movements, the presence of vertical gaze palsy, visual hallucinations and an impaired electroretinogram (ERG). Aspects of primary vision such as visual acuity, colour vision or visual fields are usually unaffected. Management of the disease to deal with problems of walking, movement, daily tasks and speech problems is important in MSA. Optometrists can work in collaboration with the patient and health-care providers to identify and manage the patient's visual deficits. A more specific role for the optometrist is to correct vision to prevent falls and to monitor the anterior eye to prevent dry eye and control blepharospasm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Corticobasal degeneration is a rare, progressive neurodegenerative disease and a member of the 'parkinsonian' group of disorders, which also includes Parkinson's disease, progressive supranuclear palsy, dementia with Lewy bodies and multiple system atrophy. The most common initial symptom is limb clumsiness, usually affecting one side of the body, with or without accompanying rigidity or tremor. Subsequently, the disease affects gait and there is a slow progression to influence ipsilateral arms and legs. Apraxia and dementia are the most common cortical signs. Corticobasal degeneration can be difficult to distinguish from other parkinsonian syndromes but if ocular signs and symptoms are present, they may aid clinical diagnosis. Typical ocular features include increased latency of saccadic eye movements ipsilateral to the side exhibiting apraxia, impaired smooth pursuit movements and visuo-spatial dysfunction, especially involving spatial rather than object-based tasks. Less typical features include reduction in saccadic velocity, vertical gaze palsy, visual hallucinations, sleep disturbance and an impaired electroretinogram. Aspects of primary vision such as visual acuity and colour vision are usually unaffected. Management of the condition to deal with problems of walking, movement, daily tasks and speech problems is an important aspect of the disease.