132 resultados para electrokinetic
Resumo:
The interaction of guar gum with the hydrophobic solids namely talc, mica and graphite has been investigated through adsorption, electrokinetic and flotation experiments. The adsorption densities of guar gum onto the above hydrophobic minerals show that they are more or less independent of pH. The adsorption isotherms of guar gum onto talc, mica and graphite indicate that the adsorption densities increase with increase in guar gum concentration and all the isotherms follow the as L1 type according to Giles classification. The magnitude of the adsorption density of guar gum onto the above minerals may be arranged in the following sequence: talc > graphite > mica The effect of particle size on the adsorption density of guar gum onto these minerals has indicated that higher adsorption takes place in the coarser size fraction, consequent to an increase in the surface face-to-edge ratio. In the case of the talc and mica samples pretreated with EDTA and the leached graphite sample, a decrease in the adsorption density of guar gum is observed, due to a reduction in the metallic adsorption sites. The adsorption densities of guar gum increase with decrease in sample weight for all the three minerals. Electrokinetic measurements have indicated that the isoelectric points (iep) of these minerals lie between pH 2-3, Addition of guar gum decreases the negative electrophoretic mobility values in proportion to the guar gum concentration without any observable shift in the iep values, resembling the influence of an indifferent electrolyte. The flotation recovery is diminished in the presence of guar gum for all the three minerals, The magnitude of depression follows the same sequence as observed in the adsorption studies. The floatability of EDTA treated talc and mica samples as well as the leached graphite sample is enhanced, complementing the adsorption data, Possible mechanisms of interaction between the hydrophobic minerals and guar gum are discussed.
Resumo:
The utility of a soil microbe, namely Bacillus polymyxa, in the removal of organic reagents such as dodecylamine, ether diamine, isopropyl xanthate and sodium oleate from aqueous solutions is demonstrated. Time-bound removal of the above organic reagents from an alkaline solution was investigated under different experimental conditions during bacterial growth and in the presence of metabolites by frequent monitoring of residual concentrations as a function of time, reagent concentration and cell density. The stages and mechanisms in the biodegradation process were monitored through UV-visible and FTIR spectroscopy. Surface chemistry of the bacterial cells as well as the biosorption tendency for various organics were also established through electrokinetic and adsorption density measurements. Both the cationic amines were found to be biosorbed followed by their degradation through bacterial metabolism. The presence of the organic reagents promoted bacterial growth through effective bacterial utilization of nitrogen and carbon from the organics. Under optimal conditions, complete degradation and bioremoval of all the organics could be achieved.
Resumo:
Adhesion of Thiobacillus ferrooxidans to pyrite and chalcopyrite in relation to its importance in bioleaching and bioflotation has been studied. Electrokinetic studies as well as FT-IR spectra suggest that the surface chemistry of Thiobacillus ferrooxidans depends on bacterial growth conditions. Sulfur-,Pyrite- and chalcopyrite-grown Thiobacillus ferrooxidans were found to be relatively more hydrophobic. The altered surface chemistry of Thiobacillus ferrooxidans was due to secretion of newer and specific proteinaceous compounds. The adsorption density corresponds to a monolayer coverage in a horizontal orientation of the cells. The xanthate flotation of pyrite in presence of Thiobacillus ferrooxidans is strongly depressed where as the cells have insignificant effect on chalcopyrite flotation. This study demonstrate that: (a)Thiobacillus ferrooxidans cells can be used for selective flotation of chalcopyrite from pyrite and importantly at natural pH values. (b)Sulfur-grown cells exhibits higher leaching kinetics than ferrous ion-grown cells.
Resumo:
The objective of the present work is to understand the vertical electric field stimulation of the bacterial cells, when grown on amorphous carbon substrates in vitro. In particular, the antibacterial activity against Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli are studied using MTTassay, live/dead assay and inner membrane permeabilization assays. In our experiments, the carbon substrate acts as one electrode and the counter electrode is positioned outside the culture medium, thus suppressing the current, electrokinetic motions and chemical reactions. Guided by similar experiments conducted in our group on neuroblastoma cells, the present experimental results further establish the interdependence of field strength and exposure duration towards bacterial growth inactivation in vitro. Importantly, significant reduction in bacterial viability was recorded at the 2.5 V/cm electric field stimulation conditions, which does not reduce the neural cell viability to any significant extent on an identical substrate. Following electrical stimulation, the bacterial growth is significantly inhibited for S. aureus bacterial strain in an exposure time dependent manner. In summary, our experiments establish the effectiveness of the vertical electric field towards bacterial growth inactivation on amorphous carbon substrates, which is a cell type dependent phenomenon (Gram-positive vs. Gram-negative). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
In the present study, the heat transfer characteristics of thermally developing magnetohydroclynamic flow of nanofluid through microchannel are delineated by following a semi analytical approach. The combined influences of pressure driven flow, electroosmotic transport and magnetic field is taken into account for the analysis of the complex microscale thermal transport processes. Solutions for the normalized temperature distributions and the Nusselt number variations, considering the simultaneous interplay of electrokinetic effects (electroosmosis), magnetic effects, Joule heating and viscous dissipation are obtained, for constant wall temperature condition. Particular attention is paid to assess the role of nanolluids in altering the transport phenomena, through variations in the effective nanoparticle volume fractions, as well as the aggregate structure of the particulate phases. It is observed that magnetohydrodynamic effect reduces advective transport of the liquid resulting in gradual reduction of heat transfer. Increase in nanoparticle volume fraction shows decrease in heat transfer. Similar effects are observed with increase in aggregate sizes of the nanoparticles. The effect of the nanofluids on system irreversibility is also studied through entropy generation analysis due to flow and heat transfer in the microchannel. Total entropy generation is found to be dominant at the thermally developing region of the microchannel, whereas it drops sharply at the thermally developed region. Presence of nanoparticles in the base fluid reduces the total entropy generation in the microchannel, thereby indicating decrease in thermodynamic irreversibility with increasing nanoparticle volume fraction. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Focusing particles into a tight stream is usually a necessary step prior to separating and sorting them. We present herein a proof-of-concept experiment of a novel particle focusing technique in DC electrokinetic flow through a planar serpentine microchannel. This focusing stems from the cross-stream dielectrophoretic motion induced within the channel turns. The observed particle focusing behavior is consistent with the predicted particle trajectories from a numerical modeling.
Resumo:
In this paper, we demonstrate for the first time that insulative dielectrophoresis can induce size-dependent trajectories of DNA macromolecules. We experimentally use lambda (48.5 kbp) and T4GT7 (165.6 kbp) DNA molecules flowing continuously around a sharp corner inside fluidic channels with a depth of 0.4 mum. Numerical simulation of the electrokinetic force distribution inside the channels is in qualitative agreement with our experimentally observed trajectories. We discuss a possible physical mechanism for the DNA polarization and dielectrophoresis inside confining channels, based on the observed dielectrophoresis responses due to different DNA sizes and various electric fields applied between the inlet and the outlet. The proposed physical mechanism indicates that further extensive investigations, both theoretically and experimentally, would be very useful to better elucidate the forces involved at DNA dielectrophoresis. When applied for size-based sorting of DNA molecules, our sorting method offers two major advantages compared to earlier attempts with insulative dielectrophoresis: Its continuous operation allows for high-throughput analysis, and it only requires electric field strengths as low as approximately 10 Vcm.
Resumo:
This paper describes a new way to perform hydrodynamic chromatography (HDC) for the size separation of particles based on a unique recirculating flow pattern. Pressure-driven (PF) and electro-osmotic flows (EOF) are opposed in narrow glass microchannels that expand at both ends. The resulting bidirectional flow turns into recirculating flow because of nonuniform microchannel dimensions. This hydrodynamic effect, combined with the electrokinetic migration of the particles themselves, results in a trapping phenomenon, which we have termed flow-induced electrokinetic trapping (FIET). In this paper, we exploit recirculating flow and FIET to perform a size-based separation of samples of microparticles trapped in a short separation channel using a HDC approach. Because these particles have the same charge (same zeta potential), they exhibit the same electrophoretic mobility, but they can be separated according to size in the recirculating flow. While trapped, particles have a net drift velocity toward the low-pressure end of the channel. When, because of a change in the externally applied PF or electric field, the sign of the net drift velocity reverses, particles can escape the separation channel in the direction of EOF. Larger particles exhibit a larger net drift velocity opposing EOF, so that the smaller particles escape the separation channel first. In the example presented here, a sample plug containing 2.33 and 2.82 microm polymer particles was introduced from the inlet into a 3-mm-long separation channel and trapped. Through tuning of the electric field with respect to the applied PF, the particles could be separated, with the advantage that larger particles remained trapped. The separation of particles with less than 500 nm differences in diameter was performed with an analytical resolution comparable to that of baseline separation in chromatography. When the sample was not trapped in the separation channel but located further downstream, separations could be carried out continuously rather than in batch. Smaller particles could successfully pass through the separation channel, and particles were separated by size. One of the main advantages of exploiting FIET for HDC is that this method can be applied in quite short (a few millimeters) channel geometries. This is in great contrast to examples published to date for the separation of nanoparticles in much longer micro- and nanochannels.
Resumo:
In this paper, we described a simple and rapid method, capillary electrophoresis with electrochemiluminescence (CE-ECL) detection using tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)), to simultaneously detect pethidine and methadone. Analytes were injected to separation capillary of 67.5 cm length (25 mu m i.d., 360 mu m o.d.) by electrokinetic injection for 10 s at 10 kV.
Resumo:
A simultaneous electrochemiluminescence (ECL) and electrochemical (EC) detection scheme for NACE was presented for fast analysis of tertiary amines. Both ECL and EC signals were generated at the same Pt electrode. Triethylamine (TEA), tripropylamine (TPrA), chlorpromazine, promethazine, and dioxopromethazine (DPZ) were selected to validate NACE-ECL/EC dual detection strategy. The linear ranges for TEA and TPrA were 0.01-500 and 0.01-10 mu M with the detection limits of 8.0 and 5.0 nM (S/N=3), respectively. The RSDs (n = 6) of the migration time and the ECL intensity for 1 mu M TEA and 0.5 mu M TPrA were 0.1 and 2.8%, and 0.2 and 1.8% with theoretical plate numbers of 180 000 and 700 000 per meter, respectively. These two analytes could be separated within 92 s and the Pt electrode did not need reactivation during the experiments.
Resumo:
This review, covering reports published from 2001 to December 2008, shows how ionic liquids (ILs) have made significant contributions in the improvement of capillary and microchip electrophoresis (CE and mu CE) for the separation and detection of analytes such as phenols and aromatic acids, metal ions, medicines, enantiomers. biological materials, etc. Furthermore, CE methods applied in the sensitive and accurate determination of physico-chemical properties of ILs have been summarized. Accordingly, research vacancies and future development trends in these areas are discussed.
Resumo:
Herein, one water-soluble functionalized ionic liquid, 1-butyl-3-methylimidazolium dodecyl sulfate ([BMIm(+)][C12H25SO4-]), was designed and its superiorities either used as supporting electrolytes or as additives for successful establishment of MEKC with electrochemiluminescence (ECL) detection (MEKC-ECL) method were investigated. Compared with the common supporting electrolytes such as phosphate solution, 1-butyl-3-methylimidazolium dodecyl sulfate solution used as running buffers led to greatly enhanced ECL intensities and column efficiencies for negative targets, a little increase for neutral-charge ones while maintained nearly unchanged for positive ones due to the electrostatic forces between the large cation BMIm(+) and the solutes and the hydrophobic interactions resulting from the large anion C12H25SO4.
Resumo:
A reversed-phase high-performance liquid chromatography-diode array detector-electrospray ionization multiple-stage tandem mass spectrometry (RP-HPLC-DAD-ESl-MSn) method has been developed for the detection and analysis of lignan constituents in the methanol extract from the fruits of Schisandra chinensis (Turcz.) Baill. RP-HPLC-DAD-ESI-MSn and electrospray ionization Fourier transform ion cyclotron resonance multiple-stage tandem mass spectrometry (ESI-FT-TCR-MSn) have been applied to investigate the characteristic product ions of four lignan reference compounds. Then, the logical fragmentation pathways of the lignans have been proposed. By comparing the retention time (t(R)) of HPLC, the ESI-MSn data and the structures of analyzed compounds with the data of reference compounds and in the literature, 11 peaks in HPLC have been unambiguously identified and another 5 peaks have been tentatively identified or deduced. Also, in the present paper, the extracted ion chromatograms (EIC) have been used to analyze the lignan isomers. The experimental results demonstrate that RP-HPLC-DAD-ESI-MSn is a specific and useful method for the identification of the lignan constituents and their isomers.
Resumo:
Capillary electrophoresis (CE) coupling with a tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of two 8-blockers, atenolol (AT) and metoprolol (ME). The parameters that influence the separation and detection, including the buffer pH and concentration, the separation voltage, the detection potential and Ru(bpy)(3)(2+) concentration, were optimized in detail. The calibration curve was linear over a concentration range of two or three orders of magnitude for the two beta-blockers. The detection limits for AT and ME were 0.075 and 0.005 mu M (S/N = 3). The relative standard deviations (n = 8) of the ECL intensity and the migration time were 2.65 and 0.22% for AT, 2.82 and 0.34% for ME, respectively. The proposed method was applied to determine AT and ME in spiked urine samples; satisfactory results were obtained.