956 resultados para electro magnetic noise nuclear detector coaxial cable twisted pair multi wire chamber pixel anode
Resumo:
The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].
Resumo:
This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.
Resumo:
This paper proposes to use a state-space technique to represent a frequency dependent line for simulating electromagnetic transients directly in time domain. The distributed nature of the line is represented by a multiple 1t section network made up of the lumped parameters and the frequency dependence of the per unit longitudinal parameters is matched by using a rational function. The rational function is represented by its equivalent circuit with passive elements. This passive circuit is then inserted in each 1t circuit of the cascade that represents the line. Because the system is very sparse, it is possible to use a sparsity technique to store only nonzero elements of this matrix for saving space and running time. The model was used to simulate the energization process of a 10 km length single-phase line. ©2008 IEEE.
Resumo:
The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
This article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.
Resumo:
This paper presents a method for analyzing electromagnetic transients using real transformation matrices in three-phase systems considering the presence of ground wires. So, for the Z and Y matrices that represent the transmission line, the characteristics of ground wires are not implied in the values related to the phases. A first approach uses a real transformation matrix for the entire frequency range considered in this case. This transformation matrix is an approximation to the exact transformation matrix. For those elements related to the phases of the considered system, the transformation matrix is composed of the elements of Clarke's matrix. In part related to the ground wires, the elements of the transformation matrix must establish a relationship with the elements of the phases considering the establishment of a single homopolar reference in the mode domain. In the case of three-phase lines with the presence of two ground wires, it is unable to get the full diagonalization of the matrices Z and Y in the mode domain. This leads to the second proposal for the composition of real transformation matrix: obtain such transformation matrix from the multiplication of two real and constant matrices. In this case, the inclusion of a second matrix had the objective to minimize errors from the first proposal for the composition of the transformation matrix mentioned. © 2012 IEEE.
Digital filtering of oscillations intrinsic to transmission line modeling based on lumped parameters
Resumo:
A correction procedure based on digital signal processing theory is proposed to smooth the numeric oscillations in electromagnetic transient simulation results from transmission line modeling based on an equivalent representation by lumped parameters. The proposed improvement to this well-known line representation is carried out with an Finite Impulse Response (FIR) digital filter used to exclude the high-frequency components associated with the spurious numeric oscillations. To prove the efficacy of this correction method, a well-established frequency-dependent line representation using state equations is modeled with an FIR filter included in the model. The results obtained from the state-space model with and without the FIR filtering are compared with the results simulated by a line model based on distributed parameters and inverse transforms. Finally, the line model integrated with the FIR filtering is also tested and validated based on simulations that include nonlinear and time-variable elements. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Molecules containing the guanidinic nuclei possess several pharmacological applications, and knowing the preferred isomers of a potential drug is important to understand the way it operates pharmacologically. Benzoylguanidines were synthesized in satisfactory to good yields and characterized by NMR, Electrospray Ionization Mass Spectrometry (ESI-MS) and Fourrier Transform InfraRed Spectroscopy techniques (FTIR). E/Z isomerism of the guanidines was studied and confirmed by NMR analysis in solution (1H-13C Heteronuclear Single Quantum Coherence (HSQC) and Heteronuclear Multiple-Bond Correlation (HMBC), 1H-15N HMBC, 1H- 1H Correlation Spectroscopy (COSY) and Nuclear Overhauser Effect Spectroscopy (NOESY) experiments) at low temperatures. Compounds with p-Cl and p-Br aniline moiety exist mainly as Z isomer with a small proportion of E isomer, whereas compounds with p-NO2 moiety showed a decrease in proportion of isomer Z. The results are important for the application of these molecules as enzymatic inhibitors. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
Esta tese apresenta uma metodologia para avaliação de desempenho de redes de acesso banda larga. A avaliação de desempenho de redes é uma forma de identificar e analisar como determinadas características tais como diferentes tipos de tráfego ou formas de utilização, por exemplo, podem influenciar no comportamento da rede em foco, podendo assim prever como tal rede se comportará frente a situações futuras. A metodologia apresentada é composta de duas abordagens: uma abordagem baseada em medições e outra baseada em modelagem via processos Markovianos. As redes analisadas englobam os dois tipos básicos de arquitetura de acesso: redes ADSL2+ (linha digital do assinante assimétrica 2+ – Asymmetric Digital Subscriber Line 2+), as quais são redes cabeadas que utilizam cabos metálicos de pares trançados; redes FBWN (rede sem fio banda larga fixa – Fixed Broadband Wireless Network), as quais são redes sem fio (wireless) baseadas no padrão IEEE 802.16. A abordagem de medições é focada na forma como a rede analisada se comporta frente a três situações: transmissão de um tráfego genérico; impacto de ruídos não-estacionários no sistema; e uso da rede como meio de transmissão de tráfego multimídia em tempo real. A abordagem de modelagem, por sua vez, ´e baseada em prever o comportamento das redes analisadas utilizando uma formulação matemática fundamentada em processos Markovianos. Os resultados apresentados indicam a viabilidade de aplicação desta metodologia como forma de avaliação de desempenho. Os resultados ainda tornam possível a extensão desta metodologia a outros tipos de redes de acesso banda larga, tais como: redes de fibras ópticas, redes de enlaces de microondas, redes VDSL/VDSL2 (linha digital do assinante de alta taxa de dados – Very-high-data-rate DSL), etc.
Resumo:
Este trabalho tem como objetivo geral analisar experimentalmente técnicas para medição de descargas parciais nos enrolamentos estatóricos de hidrogeradores. Para atingir o objetivo proposto, primeiramente foi realizado um estudo bibliográfico sobre como é a estrutura dos enrolamentos do estator, com ênfase na isolação elétrica, assim como os conceitos de descargas parciais e técnicas empregadas para medição em hidrogeradores. Em seguida, foi montado em laboratório um arranjo experimental para o estudo das técnicas de medição de descargas parciais nos enrolamentos do estator utilizando seis acopladores diferentes, sendo quatro acopladores capacitivos convencionais de 80, 220, 500 e 1000 pF, e dois sistemas experimentais, uma antena SSC fabricada com microfita e um cabo coaxial RG 58, desencapado, utilizado como antena. A avaliação da sensibilidade destes seis sistemas foi divida em duas etapas: primeiro foi analisada a resposta dos acopladores à aplicação de um sinal conhecido de calibração e, em seguida, foi analisada a resposta dos mesmos durante ensaios com alta tensão. Para aplicação de um sinal conhecido de calibração os acopladores capacitivos apresentaram maior sensibilidade em relação à antena e ao cabo coaxial. Já a resposta durante os ensaios com alta tensão mostrou que a sensibilidade da antena é maior que a do método convencional de medição de descargas parciais em hidrogeradores, baseado em acopladores capacitivos de 80 e 220 pF. Os resultados obtidos em laboratório mostraram que a medição de descargas parciais através da antena pode ser realizada de forma satisfatória na avaliação da condição operacional dos enrolamentos do estator de hidrogeradores, sem perda significativa de informação e com aumento significativo de sensibilidade na quantificação do fenômeno, cerca de duas vezes maior que a sensibilidade do acoplador de 220 pF e quatro vezes a do acoplador de 80 pF.
Resumo:
Magnetic resonance imaging (MRI), which is studied since 1938, is a technique used in medicine to produce high quality images from inside the human body. These images are produced non-invasively and without ionizing radiation. In addition, MRI is an extremely flexible technique, with which it is possible to produce images with different contrasts that provide different information about the anatomy, structure and function of the human body, and it is therefore one of the techniques preferred by radiologists. The phenomenon of MRI is based on the interaction of magnetic fields with the nuclear spins of the scanned sample. In this work a detailed study of the technique of magnetic resonance imaging is presented, with a description of the main features of the images produced by the technique and an analysis of its application to the fields of applications Neurology and Neuroscience
Resumo:
A transmission line is characterized by the fact that its parameters are distributed along its length. This fact makes the voltages and currents along the line to behave like waves and these are described by differential equations. In general, the differential equations mentioned are difficult to solve in the time domain, due to the convolution integral, but in the frequency domain these equations become simpler and their solutions are known. The transmission line can be represented by a cascade of π circuits. This model has the advantage of being developed directly in the time domain, but there is a need to apply numerical integration methods. In this work a comparison of the model that considers the fact that the parameters are distributed (Universal Line Model) and the fact that the parameters considered concentrated along the line (π circuit model) using the trapezoidal integration method, and Simpson's rule Runge-Kutta in a single-phase transmission line length of 100 km subjected to an operation power. © 2003-2012 IEEE.
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
Computer and telecommunication networks are changing the world dramatically and will continue to do so in the foreseeable future. The Internet, primarily based on packet switches, provides very flexible data services such as e-mail and access to the World Wide Web. The Internet is a variable-delay, variable- bandwidth network that provides no guarantee on quality of service (QoS) in its initial phase. New services are being added to the pure data delivery framework of yesterday. Such high demands on capacity could lead to a “bandwidth crunch” at the core wide-area network, resulting in degradation of service quality. Fortunately, technological innovations have emerged which can provide relief to the end user to overcome the Internet’s well-known delay and bandwidth limitations. At the physical layer, a major overhaul of existing networks has been envisaged from electronic media (e.g., twisted pair and cable) to optical fibers - in wide-area, metropolitan-area, and even local-area settings. In order to exploit the immense bandwidth potential of optical fiber, interesting multiplexing techniques have been developed over the years.
Resumo:
The Er3+-Yb3+ co-doped MgAl2O4 phosphor powders have been prepared by the combustion method. The phosphor powders are well characterized by X-ray diffraction (XRD) and energy dispersive (EDX) techniques. The absorption spectrum of Er3+/Er3+-Yb3+ doped/co-doped phosphor powder has been recorded in the UV-Vis-NIR region of the electro-magnetic spectrum. The evidence for indirect pumping under 980 nm excitation of Er3+ from Yb3+ was observed in the MgAl2O4 matrix material. Electron spin resonance (ESR) studies were carried out to identify the defect centres responsible for the thermally stimulated luminescence (TSL) process in MgAl2O4:Er3+ phosphor. Three defect centres were identified in irradiated phosphor by ESR measurements which were carried out at room temperature and these were assigned to an O- ion and F+ centres. O- ion (hole centre) appears to correlate with the low temperature TSL peak at 210 A degrees C and one of the F+ centres (electron centre) is related to the high temperature peak at 460 A degrees C.